Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
9 Jul 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TELECOM
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work of Provision or maintenance of Automatic Fire Detection & Alarm/Automatic Fire Suppression System. OR Any signalling work which includes provision of Automatic Fire Detection & Alarm/Automatic Fire Suppression System. Note1: Tenderer may be required to submit the schedule of those works, completion/ performance Certificate of which have been submitted by him/her in support of 30/40/60 % (as the case may be) criterion of similar nature of works.
22 conditions · 12 needing a document upload
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Provisioning of Automatic Fire Detection and Fire Alarm System for the safety of Telecom facilities at way side station/Location over LKO division, Northern Railway
106-Tele_Tender_07_26-27
106-Tele_Tender_07_26-27
Open
Works - General
180 Days
Lucknow, Uttar Pradesh
₹0
₹3.2 L
9 Jul 2026
18 Jun 2026
25 Jun 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,61,87,237.54 | ||
| — | 12.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Microprocessor based Networkable analog Addressable, and modular type of Fire Alarm Control Panel with display with 2 loop expandable up to four loop, power supply and battery backup as per RDSO/SPN/217/2025 ver3.1 or latest, including. GSM module-01No for sending SMS to configured mobile number and relay module- 02 Nos for connecting to data logger for remote monitoring. The panel should support sufficient devices of both detectors and modules in a single line circuit. INSPECTION: RDSO FOR SUPPLY PORTION | — | — | — | 7,25,919.84 | |
| — | 468.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Addressable heat and smoke Multi sensor. As per RDSO specification no RDSO/SPN/217/2025 Ver3.1 or latest. INSPECTION: RDSO FORSUPPLY PORTION | — | — | — | 11,53,474.92 | |
| — | 274.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point within built short circuit fault isolator.( As per RDSO specification no RDSO/SPN/217/2025 Ver 3.1 or latest.) INSPECTION: RDSO FOR SUPPLY PORTION | — | — | — | 8,84,488.44 | |
| — | 2000.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Linear Heat Sensing(LHS) cable as per RDSO Specification No. RDSO/SPN/ 217/2025 ver 3.1 or latest. INSPECTION: RDSO FOR SUPPLY PORTION | — | — | — | 13,08,940 | |
| — | 10.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/SPN/217/2025 ver. 3.1 or latest. INSPECTION: RDSO FOR SUPPLY PORTION | — | — | — | 5,19,002.8 | |
| — | 147.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/2025 ver 3.1 or latest. INSPECTION: RDSO FOR SUPPLY PORTION | — | — | — | 11,85,665.25 | |
| — | 33100.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of FRLS unarmoured/armoured cable (2Cx1.5 sq.mm) with allaccessories for connection of all FireAlarm devices as per RDSO SpecificationNo. RDSO/ SPN/ 217/2025 ver 3.1 orlatest. INSPECTION: RDSO FOR SUPPLYPORTION" | — | — | — | 32,71,935 | |
| — | 6.00 | — | — | ||
| Supply,Installation,Testing &Commissioning of Aspiration systemswith single pipe slot along with requiredmodule and power supply interfacingmodule etc as per RDSO specification noRDSO/SPN/217/2025 Ver 3.1 or latest.INSPECTION: RDSO FOR SUPPLYPORTION | — | — | — | 9,92,328.48 | |
| — | 150.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of CPVC pipe and allother associated fittings. As per RDSOspecification No.RDS0/SPN/217/2025Ver3.1 or latest. INSPECTION: RDSOFOR SUPPLY PORTION | — | — | — | 1,23,703.5 | |
| — | 20.00 | — | — | ||
| Supply,Installation,Testing &Commissioning of hooter cum strobeincluding its control module as perRDSO Specification NORDSO/SPN/217/2025 Ver 3.1 or latest.INSPECTION: RDSO FOR SUPPLYPORTION | — | — | — | 68,020.8 | |
| — | 175.00 | — | — | ||
| Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI marked, with all accessories, operating temperature (-30)° to (50)° for class 13B type of fire with 1 meter long hosepipe fitted with PVC bend horn, with carrying handle and wall mounting bracket, complete in all respect. It should conform to IS 2878:2004. Extinguisher certificate has to be supplied along with the item. INSPECTION: RITES FOR SUPPLY PORTION | — | — | — | 7,26,360.25 | |
| — | 141.00 | — | — | ||
| Supply of Steel stool, 1 ft by 1 ft size,1.5 ft height, laminated top.INSPECTION: CONSIGNEE FOR SUPPLYPORTION | — | — | — | 1,25,983.5 | |
| — | 141.00 | — | — | ||
| Supply of lateral filing cabinet of sizeminimum 900 mm x 900 mm (3 ft x 3ft) to store circuit diagrams, makeGodrej/Durian/Methodex/President or ofsimilar reputed make. INSPECTION:RITES FOR SUPPLY PORTION | — | — | — | 17,66,784.99 | |
| — | 139.00 | — | — | ||
| Supply of self supported aluminiumflatstep ladder (Confirming of ISI)10ft.height (Telescopic). Make : Skyward/Kalco/SJ Ladders/similar / superior.INSPECTION: RITES FOR SUPPLYPORTION | — | — | — | 9,84,646.81 | |
| — | 308.00 | — | — | ||
| Smoke Detector Tester Spray(200ml/117 gm) brand Aerol or Superiorwith a 3 feet throw. NONSTAINING,NON-TOXIC,NO RESIDUEINSPECTION: CONSIGNEE FOR SUPPLYPORTION | — | — | — | 2,99,720.96 | |
| — | 5600.00 | — | — | ||
| Supply of 20 Pair PIJF cable 0.63 MM armoured cable as per TEC Spec GR/CUG-01/03 (August 2003) Make: Usha Martin or Similar. INSPECTION: RITES FORSUPPLY PORTION | — | — | — | 9,64,992 | |
| — | 1680.00 | — | — | ||
| Horizontal directiondrilling(HDD)/Trenchlessdigging/machine drilling withoutdamage to surface road/trackfor laying/insertionofHDPE/GI/DWC pipe. The boreshall bedone at the depth ofminimum 1400 mmfrom theground level. The groundlevelshall be considered ignoringthebank height of the bank of the road.Note:- DWC/HDPE/GI PipeSupply is notcovered under thisitem. Contactor shallprovide allmaterial required for workandadequate nos. of labours forproperlaying of cables into thebore. Cable shallbe laidcautiously so that it should notgetdamage due to roughhandling &pressure on cable.Payment of boringshall bemade only aft erDWC/HDPE/GIpipe is laid in the bore." | — | — | — | 8,34,657.6 | |
| — | 3920.00 | — | — | ||
| Excavation of cable trench as per cableroute plan, 1.2 Mtr. deep and of 0.3 Mtr.to 0.6 Mtr. wide at bottom as per RDSOsketch No. SDO/CABLE LAYING/003 orlatest alongside the track in normal (alltype) soil/strata, conforming todistances as per cable route plan andrefilling. This work includes clearing ofroute from bushes etc, covering of cablelaid in trench by loose soil for a layer of50mm thickness approximately beforecovering by bricks. The work shall bedone as per the extant practice on NorthWestern Railway and instructions ofRailway Engineer at site. In case 1.2mdepth of trench is not achievable due tosite conditions, specific approval of JAgrade officer will be required for eachsite where trench depth of 1.2m is notpossible. Without the approval of JAGrade officer, no payment for trenchingwill be made for trench depth less than1.2m. | — | — | — | 2,21,401.6 | |
| — | 40.00 | — | — | ||
| Supply of DP Box 20Pair with KroneModules. INSPECTION: CONSIGNEE FORSUPPLY PORTION | — | — | — | 27,819.2 | |
| — | 40.00 | — | — | ||
| Installation of DP Box 20Pair. The workis toexecuted as per theinstruction ofRailwayEngineer. | — | — | — | 1,391.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
T-0726-27.pdf
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .