| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC CHOLADHARA JORAHAT 785001 ASSAM | JORHAT | ASSAM | 785001 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹26.3 L+₹3.4 L (14.9%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹26.7 L+₹3.8 L (16.6%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
16 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR OF LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT RANGIA AND CHANGSARI MILITARY STATION UNDER GE RANGIA
2021_MES_475005_3
8474/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RANGIA AND CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹54,000
Yes
4 Jan 2022
22 Nov 2021
18 Dec 2021
22 Nov 2021
16 Dec 2021
29 Nov 2021
60 days
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 01 above but depth exceeding 1.5 m or part thereof in depth beyond the first 1.5 m in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and as directed by Engineer-in-charge.
Removing excavated materials (soils) not exc. 50.00 m and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge. Note - Only punned thickness shall be measured and paid.
Taking out old unserviceable underground LT cable of any size from trenches, floors and walls, complete all as per specified and as directed by Engineer-in-charge.
Supply, laying and testing of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 300 sqmm 3.5 core complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 07 above but for size of cable 35 sqmm 3.5 core.
All as per serial item No. 07 above but for size of cable 95 sqmm 3.5 core.
All as per serial item No. 07 above but for size of cable 120 sqmm 3.5 core.
Laying only serviceable cable of any size complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 50 mm bore light grade for protection of UG cable, complete all as specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 40 mm bore light grade for protection of UG cable, complete all as specified and as directed by Engineer-in-charge.
Boring of holes under road, pavement, hard standing, drain etc. by conventional method not exceeding 6 mtr in length for laying of cable for protection under GI pipe complete all as per specified and as directed by Engineer-in-charge.
S&F cable jointing kit for 1100 v (earthed) grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70-150 Sqmm including taking down the old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F cable jointing kit for 1100 v (earthed) grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 240-300 Sqmm including taking down the old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Dismantling LT over head ACSR conductor of any size including separating, serviceable conductor and kept in safe custody for re-use in the work and removing unserviceable conductor from the site complete all as specified and as directed by Engineer-in-charge.
S&F aluminum conductor steel reinforced (ACSR) on over head LT electric line with stretching and tensioning the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2mm dia complete all as specified and as directed by Engineer-in-charge.
Restringing only of old serviceable ACSR conductor obtained from serial item no. 12 above including binding complete all as specified and as directed by Engineer-in-charge.
Dismantling of rusted/corroded earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed by Engineer-in-charge.
S&F galvanized wire 3.15mm dia as in continuous earth wire/guard or cradle wire made to required shape fixed on poles for LT feeder including binding the same with new GI binding wire not less than 2mm dia complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 22 above but fixing only of old serviceable conductor including binding.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 4 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 3 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F PVC line separator of 10 mm dia fixed on LT over head line of 2 span including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
M&L for jumper of two sides of ACSR conductor on over head with same conductor of length 1 mtr including taking down old unserviceable one complete all as per specified and as directed by Engineer-in-charge.
Dismantling of cross arms fixed on Steel tubular poles carefully including separating and getting aside, serviceable cross arms for re-use in the work and removing unserviceable cross arms from site complete all as specified and as directed by Engineer-in-charge.
S&F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts and washers drilled for insulator bolts welding bending cold or hot in any shape or size as directed and painted with two coats of aluminium paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable cross arms obtained from Sch `A’ serial Item No 28 here-in-before with providing new bolts, nuts and washers as required including painting with one coat of aluminium paint after preparation of old surfacecomplete all as specified and as directed by Engineer-in-charge.
Dismantling of old unserviceable bending/broken steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation of earth work as required and removing the same from site complete all as specified and as directed by Engineer-in-charge.
Supply and erection of steel tubular swaged poles 9.0 metre long, type 410 SP-31 in true verticle position complete with cast iron base plate, final taper plug, bolts, nuts and screws, pole cap, etc. confirming to IS-2713 of 1980 including painting with two coats of black bituminious paint throughout internally and externally upto the planting depth and the remaining portion of exterior surface shall be painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces and numbering to be done in black synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 (using 40mm grade crushed stone aggregate) as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-1 (using 20mm grade crushed stone aggregate) as in coping of steel tubular poles and stay with necessary form work as required complete all as specified and as directed by Engineer-in-charge.
M&L for preparing of old painted surface of steel tubular electric pole 9 mtr long (effective painted length from top of foundation concrete to top of pole) including struts cross arms clamp, etc fitted on pole and applied one coat of aluminum paint after properly cleaned with sandpaper/wire brushes and including making alternate white and black strips 30 cms height (05 Nos strips) numbering of the poles by 2" height letters complete all as specified and as directed by Engineer-in-charge.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete including excavation of earth work as required and removing the same from site complete all as specified and as directed by Engineer-in-charge.
S&F galvanized stay wire (stay strand) of size 7 / 3.15 mm with properly tightening the same complete all as specified and as directed by Engineer-in-charge.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No. 1 of SSR Part I with using stay rod of 16 mm dia., 1.8 m long and stay plate galvanised steel of size 23 cm x 23 cm x 6 mm thick complete all as specified and as directed by Engineer-in-charge.
Dismantling of LT insulators of any type and size from position and removing unserviceable insulators from site complete all as specified and as directed by Engineer-in-charge.
S&F pin type insulator porcelain vitreous, white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washer and one galvanized iron nut 100mm height 65mm dia for 1100 volts grade complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No 40 above but for fixing only old serviceable pin type insulator.
S&F shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including mild steel straps of section 31mmx3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No 42 above but for fixing only old serviceable shackle type insulator.
S&F loop type insulator vitreous porcelain white, brown or green large size with overall dimensions 90 x 140mm and clearance of hole 25.5mm complete all as specified and as directed by Engineer-in-charge.
Cutting and trimming of tree branches, bushes n.exc 3 m girth all along LT overhead lines/guard wire and removing branches out of defence land complete all as specified and as directed by Engineer-in-charge.
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as per specified and as directed by Engineer-in-charge
Taking down existing old unserviceable MCCB/Main Switch of 63 to 400 Amps from the panel, complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 400 amps, 4 pole, 415 Volt with breaking capacity 35/36 KA complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 250 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 160 amps, 4 pole, 415 Volt fixed type with breaking capacity 16 KA, complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing 4 pole MCCB 63 Amp 50 HZ 415V with rapturing capacity of 16 KA complete all as per specified and as directed by Engineer-in-charge.
M & L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including 25 x 4 mm GI strip upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15 mm dia GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mm c/c and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing and as shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F clean agent fire extinguisher (Manual) Eco friendly extinguisher zero ODP (Ozone Depletion Properties) can be used propellant gas Department FE-36 (Hexa flura propane gas) 4 Kg filled in bottle including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair power factor controller relay 1 CT IPFC CS 1001-108-90 V / 550 Vac 144 x 144 in existing APFC panel insulated including necessary connection and taking down old unserviceable one complete all as per specified and as directed by Engineer-in-charge.
S&F in repair power factor capacitor bank heavy duty of 10 kVAr in existing APFC panel insulated including necessary connection with capacitor duty contactor and making APFC Panel functional, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 55 above but for 15 kVAr capacity.
All as per serial item No. 55 above but for 25 kVAr capacity.
S&F 35 watt, 230 V AC street light fitting New generation, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 with all accessories and electrical connection complete all as specified and as directed by Engineer-in-charge.
S&F MCCB 200 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, complete all as per specified and as directed by Engineer-in-charge.
S&F street light bracket made out of GI tubing 32 mm bore medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including taking out old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F MCCB 100 amps, 4 pole, 415 Volt fixed type with breaking capacity 16 KA, complete all as per specified and as directed by Engineer-in-charge.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded 16 Sqmm aluminium conductor served with inner sheathing of PVC cape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 m apart including 4 mm dia suspension wire one twin core cable flat or circular including taking out old unserviceable cable complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
R K Enterprises
M/s SHARMA BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .