Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC KILA ROAD 00 00 00 NARNAUL HARYANA 123001 | MAHENDRAGARH | HARYANA | 123001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.6 L+₹3.7 L (17.5%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
10 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura Cantt
REPAIR / MAINT OF HT UG CABLES AND OH LINES AND MISC CONNECTED WORKS IN ZONE A AND C AT HISAR MIL STN UNDER GE HISAR
2021_MES_411832_1
CWE/MTR/HSR/72 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class D cat b (ii)
7 documents required · 7 mandatory
₹500
GE Hisar
₹60,000
Yes
8 Mar 2021
12 Jan 2021
12 Feb 2021
12 Jan 2021
10 Feb 2021
29 Jan 2021
60 days
Amount
M&L for cleaning of GOD male & female contact by removing dust particles & tightening the jumpers, nuts, bolts after applying white petroleum jelly for smooth functioning complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cable etc, and for foundation of poles, stays etc. not exc 10sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for laying of cable etc. and for foundation of poles, stays etc. not exc 10sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m and not exc 3.0m in depth for laying of cable etc. and for foundation of poles, stays etc, not exc 10sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches / ducts in layers of 8cm deep before laying the cable and 15cm deep after laying and stretching the cable complete all as specified and directed. Note : Punned thickness shall be measured.
Taking out existing serviceable / unserviceable bricks / PCC cover over UG cables from trenches and stacking at site for re-use complete all as specified & directed.
Laying only old serviceable PCC cover retreived from Srl item No 06 above complete all as specified and directed.
Supplying and laying un-reinfoced precast concrete cable cover of class HV type 1 with flat size 300 x 180 x 40mm compete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in mass concrete and filling complete for foundation complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in mass concrete and filling including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M&L for returning filling in approved excavated soil including spreading levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade (Earthed) of the following sizes cable comfirming to IS-7098 Pt-II cable laid in trenches / walls / ducts / poles including taking out the old one complete all as specified and directed :-
3 Core 95 Sqmm
3 Core 120 Sqmm
3 Core 150 Sqmm
Disconnecting and taking down HT UG cable from HT pole / Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, out door type fixed with and including suitable size of heat shrinkable new jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for the following size of HT XLPE cable :-
95 Sqmm to 120 Sqmm 3 Core
150 Sqmm to 185 Sqmm 3 Core
240 Sqmm 3 Core
Disconnecting and taking down HT UG cable from HT pole / Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, indoor type fixed with and including suitable size of heat shrinkable new jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for the following size of HT XLPE cable :-
95 Sqmm to 120 Sqmm 3 Core
150 Sqmm to 185 Sqmm 3 Core
M&Lfor cable jointing Kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes all as specified and directed:-
120 Sqmm to 185 Sqmm
Testing and fault locating of HT underground cable with the help of cable fault locating machine at site including removal of moisture content from cable complete all as specified and directed. Note :- (i) The machine for locating of fault shall be arranged by the contractor and quoted rate deemed to be included it. (ii) Necessary excavation, earthwork joint etc measured and paid separately under respective item of Sch 'A' / BOQ.
Taking down faulty / damaged HT U/G cables, cutting / dressing end portion and making good end termination with and including suitable size of aluminium lugs duly crimped with crimping tool and refixing its own position including Jumpers, Insulation tape, nut, bolts etc as reqd for the following sizes complete all as specified and directed :-
95 Sqmm to 120 Sqmm 3 Core
150 Sqmm to 185 Sqmm 3 Core
Dismantling unserviceable concrete pole / struts of any size complete all as specified and directed.
Supply, errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete as specified and directed. Note : (i) The conductors / earth wires on existing pole to be shifted on new pole after errection of new pole. The rate shall be include in above quoted rate. (ii) Earth work & PCC shall be measured and paid separately.
Dismantling unserviceable stay assembly complete and removing from site complete all as specified and directed.
M&L for galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
M&L for GI Stay assembly set comprising of 14mm dia 400mm iron stay bow, 2150mm long stay rod 20mm dia, stay plate 300 x 300 x 6mm thick complete with all aceessories as shown in electric plate no 1 of MES schedule Part I complete all as specified and directed. Note :- Earth work, PCC, loop type insulator, galvanized stay stranded wire will be measured and paid separately.
M&L for GI Stay assembly set comprising of 14mm dia 400mm iron stay bow, 2150mm long stay rod 16mm dia, stay plate 300 x 300 x 6mm thick complete with all aceessories as shown in electric plate no 1 of MES schedule Part I complete all as specified and directed. Note :- Earth work, PCC, loop type insulator, galvanized stay stranded wire will be measured and paid separately.
S&F loop type insulator, vitreous porcelain, white brown or green with over all dimensions 90mm x 140mm, clearance of hole 25.5 mm suitable for 11000 volts complete all as specified and directed.
Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and directed.
M&L for Cross Arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps, nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling unserviceable galvanized earth steel wire 3.15 or 4 mm dia and existing hexagonal cradle guard HT / LT poles and removing binding wire and removal of the same from site complete all as specified and directed.
M&L earth galvanized steel wire 4 mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed.
Taking down unserviceable / old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
S&F aluminium conductor steel reinforced (ACSR) of any size for HT / LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed.
Dismantling of air break gang operated switches / DO assembly vertical / horizontal mounted including insulators and operating mechanism and removing the same from site complete all as specified and directed.
Supply installation, connecting and testing gang operated air break switch, mounted on insulators HT 11KV 200 Amps rating, triple pole, nine insulator suitable for horizontal / vertical mounting fixed and spring loaded revolving tinned brass / copper contacts, galvanized steel base frame, 32 mm bore medium grade pipe Galvanized operating rod (Medium Grade), operating handle, locking arrangement MS clamps, bolts, nuts & washers etc including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. NOTE :- (i) Cross arms of 2 pole/4 pole structure reqd for installation of GO switch, if reqd additional, shall be measured and paid seperately. (ii) Scope of work also includes ACSR conductors PVC sleeves, PG clamps and thimbles reqd for jumpers / connections to OH lines of 2 poles / 4 poles structures and outgoings feeders.
Supply and installation in replacement of drop out fuse assambly triple pole 11 KV, 25 Amps rating complete expulsion fuse element mounted on four / two pole structures complete all as specified and directed. Note : Cost of necessary nut, bolt & washers deemed to be included in quoted rate.
M&L for lightning arresters expulsion type complete with all fittings, transmission class discharge capacity 65 Kilo Amps 11000 volts complete including taking down the existing lightening arrestor complete all as specified and directed.
S&F in replacement steel water tubing medium grade of size 32mm dia conforming to IS 1239 for fixing as operating rod of switch air brake gang operated triple pole, fixed with ms galvanized steel frame including necessery welding, nuts, bolts or washers etc all as directed.
Supply and fixing in replacement steel tube of light grade galvanised with all fittings fixed to walls / floors / poles or under road etc of following sizes complete all as specified and directed. Note : (i) The GI pipe should be fixed with pole by MS clamps. (ii) The MS work should be measured and paid separately.
100mm bore
80mm bore
Dismantling insulator any type / any size from LT / HT poles GI complete all as specified and directed.
S&F insulators pin type HT porcelain, vitreous white or brown or green of size 150mm height, 150mm dia ISI marked suitable for 11 KV grade including one galvanized mild steel spindle, two GI washers and one nut complete all as specified and directed.
S&F Disc type insulator 'single disc' assembly ISI marked for tension with tension clamps for conductors, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green with tension clamps for conductors (ACSR), working pressure 11KV complete all as specified and as directed.
S&F post top insulator 11 KV suitable for air break switch / drop out fuse with necessary nuts, bolts, washers complete all as specified and directed.
M&L Preparation of existing steel surface of bracing mounted on PCC HT pole by scratching and complete removing of existing paint and painting the existing surface both side with approved shade with and including two coat of synthetic enamel paint complete all as specified and directed.
-ditto- all as per srl item '43' above but on PCC 2 pole structures including painting of bracings.
-ditto- all as per srl item '43' above but on PCC 4 pole structures including painting of bracings.
M&L painting of steel tubular HT pole including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat with aluminum paint after cleaning / preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Feeder No also complete all as specified and directed.
-ditto- all as per srl item '46' above but on 2 pole steel structures including painting of bracings.
-ditto- all as per srl item '46' above but on 4 pole steel structures including painting of bracings.
Stringing / stretching incl jointing in situ of each span not more than 55 Mtrs of two electric poles having 3 nos of ACSR of any size including GI earth continuity wire, with / without guarding wires on electric poles of any size at different locations to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and directed. Note : Each span unit includes 3 wire of HT over head line and 2 nos of earth wire.
M&L for prunning / trimming the branches of trees if any along HT / LT overhead line, 3 mtr on all side below / above / sides of HT / LT overhead line and removing the same upto 150 mtr away complete all as specified and directed. Note : The above is to be ensured for the entire contract period by cutting / trimming of branches of trees any number of times as required and to be measured and paid once.
Surface excavation n.exc 30cm depth and averaging 15cm depth and getting out in soft / loose soil including clearing away all grass and vegitation saplings, shrubs, bushes, undergrowth roots and removing rubbish upto a distance n.exc 50mtrs outside the perifery of the transformer / 2 pole / 4 pole structure / feeder pillar box / sub Stn incl Water supply and Elect supply area complete all as specified and directed. Note : The contractor will ensure that no vegitation grows during the contract period on the area so excavated.
M&L for Replacement of old jumper ACSR (conductor size not less than weasel) upto length 1.5 mtr for LT / HT OH line complete all as specified and directed.
M&L for Replacement of old jumper ACSR with PVC sleeves (conductor size not less than weasel) upto length 3.5mtr for HT with Aluminium thimble (If necessary) complete all as specified and directed.
Supply and fix DO fuse element 11/22 KV of the following Capacities complete all as specified and directed :-
5 Amps Capacity
15 Amps Capacity
40 Amps Capacity
50 Amps Capacity
Supply only for electric rubber hand gloves 11 KV rating ISI mark complete all as specified and directed.
M&L for Danger notice plate of size 25 x 20cm of 1.6mm thick mild steel sheet painted with vitreous enameled white paint, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps of flat iron of size 25 x 5mm, bolts, and nuts of approved size complete all as specified and directed.
S&F HT cable route / joint indicator made of 100mm dia cast iron top and 01 mtr long MS rod burried in ground upto 30cm and embeded in PCC (1:2:4) type B-1 block of size 15cm x 15cm x 30cm and painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways, MS handle 12mm dia for PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to and including galvanized earth lead 25 x 4.00mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 40 mm dia pipe and 20mm light grade GI pipe for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways, MS handle 12mm dia for PCC chamber pit with PCC (1:3:6) type C-1 and excavation and earth work all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI lead 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for making earth pit ,PCC chamber pit with PCC 1:3:6 type C-2 with RCC cover of concrete 1:2:4 type B-1 using 8mm reinforcement bars @ 100mm both way and incl excavation and earth work complete all as specified & directed.
M&L for laying 40mm stone aggregate in electrical installation or below 2 pole / 4 pole structure etc complete all as specified & directed.
M&L for Anti-climbing device spikes type fabricated out of MS bars (round, Square and flat ) including nuts, bolts, washers and welding into halves made to shape to suit the cross section of the pole complete all as specified and directed.
Disconnecting and taking out non functional VCB of any make of rating 11 KV, 630 Amp/ 800 Amps dismantling / opening of the VCB for servicing / overhauling taking out and removing unserviceable/ defective parts including cleaning and servicing, greasing , oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhuling / servicing and its testing complete all as specified and directed. Note :- The quoted rate of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid separately under appropriate item of Sch 'A' as supply only.
Supply only spring charging motor & gear assembly 110V AC/DC
Supply only push botton bracket assembly
Supply only Big gear assembly .
Supply only small gear assembly with motor shaft ,11 KV breaker .
Supply only Closing coil assembly 24 Volt
Supply only Tripping coil assembly, 24 volt
Supply only Closing coil assembly, 110 Volt
Supply only Tripping coil assembly, 110 volt
Supply only TNC Switch
Supply only Anti pumping device
Supply only Upper connector
Supply only Lower connector
Supply only Isolating contacts
Supply only Auxillary switch (7 NO + 7NC) model 33 PO24
Supply only Vacuum Interrupter VI (4''dia) Type WL 33379 M3+ , Make- CG
Supply only breaker operatiing mechanism of VCB Make- CG
Disconnection & repairs to vaccum circuit breaker panel incl replacement of following :-
Indicating lamps LED,24V,2 Watt with holder,any type ( Red/ Green/ White/ Amber /blue)
Phase indicating lamps 110V AC with holder (Red/ Yellow / Blue)
Push button actuator 1 No element, 22.5mm dia (TCH).
Thermostat range 30-90 deg celcius.
Bakelite HRC fuse base with carrier 32A, 415V with HRC Fuse 5amps.
Power factor meter 3 phase, 2 element dynamometer type.
Digital Ammeter 96mm x 96mm 16range 100/1600 AC, input 5A AC, Auxillary supply 110V AC, 50H2 + 1% of fs + 2 digits.
Digital AC voltmeter O-150V AC Range O-15KV, Accuracy 1.0 PTR 11KV/110V, Auxillary supply 110V AC 50H2, Make AE
Anti pumping device model APC 24C 15
Calibration of relays, 11 KV of any description through primary and secodary injection method and testing complete re-setting where required and ensuring proper functioning of earth fault and over current relays complete all as specified and directed.
Supply only Spring charging Handle for Hand opertaing complete all as specified and directed.
Disconnecting electric supply and earthed the Ring Main Unit (RMU) of cap upto 800 Amps of any make of rating 11 KV, opening of the RMU for servicing / overhauling the mechanism including cleaning and servicing, greasing, oiling of the parts etc reassembling the RMU after overhuling / servicing and its testing complete all as specified and directed.
Supply and fixing in replacement indication lamps (set of three) suitble for RMU, 11 KV complete all as specified and directed. Note for item No 63 to 68 :- The repair will be carried out from authorized agency / rep of OEM.
Material & labour for laying of insulating mat for electrical purposes, ISI marked of IS :15652 and having size 1000mm x 2000mm and 20mm thick suitable for 11 KV system, including all allied fixing materials etc complete all as specified and directed.
M/S D.N Choudhary
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .