Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
5 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director Sports
Punjab yuwa bhawn sector 42 a chandigarh
Purchase of Sports Physiotherapy Lab Equipments
2025_DOS_153608_1
07 Dated 12.11.2025
Open Tender
Medical Equipments/Waste
Item Wise
hockey stadium mohali
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹5.2 L
Directorate of Sports and Youth services, Punjab
12 Feb 2026
14 Nov 2025
8 Dec 2025
14 Nov 2025
5 Dec 2025
14 Nov 2025
26 Nov 2025
• The Device should be suitable for Musculoskeletal use. • Should be a focused shockwave based on Piezo mechanism. Should have multi array type piezo electric hand piece. Should have accuracy of the shock wave generation cycle(frequency)0~8 ㎐± 10% • Should have software-based Operating System • The unit should have large color touch screen for ease of operation. • The Unit should have accuracy of the operating frequency 0~7000Shock ±10% • The unit should have maximum energy density 0.702 m J/㎟ (when setting at 23 levels) ± 15% • Should have shock wave penetration depth 40㎜± 20%. • Should have maximum focus size. 78㎜×1.78㎜×15.81㎜± 20% • Should have Maximum pressure 44.01 ± 0.65 Mpa • The unit should be supplied with Piezo Hand piece and elastomer Gel Padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. • The life span of hand piece should be of up to 10 million shocks. Should be supplied with trolley with castor wheels. • Dimension of the device should be approximated 500mmx700mmx 1000mm • Should have CE or USFDA certified.
• It should have class IV laser solid-state • It should have inbuilt protocol for different indications • Laser wavelength should be 808nm & 980nm for 18W • It should provide Laser Power up to 0.500mW to 18W • Pick Power 18W (808 nm wavelength for 8W & 980 nm for 10W) • The unit Should have 7’’ touch screen facility for use • The unit should Operating Mode should be CW (continuous) or Pulsed • The unit supply with attachments: Scanning Laser applicator 500-550mW (class 3B) • The unit supply with Small and large attachments 1cm and 5cm should be provided to cover different areas • The unit Supply with DILA (Deep Intratissue Laser Adapter) • Supply 2 pairs of Laser protective goggles to be Supplied • Warranty 2-year Class IV laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. The class IV Deep Intratissue Laser therapy machine is European CE approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. It is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication • CDSCEO Device registration certificate Unit Supply with original Trolley
• The Unit should be 7” Colour Display with Touch Panel • Treatment Encyclopaedia • Electrodiagnostic I/t curve • Number of Built-in Programmes 204 • Number of user programs 150 • Number of compatible 2 Ultrasound Heads Electrotherapy – Parmenter • 2 channel electrotherapies • Max constant current inpatients circuit CC mode- 10. Galvanic current – 40 mA • Diadynamic, pules, current – 60 mA • Interferential, kotz, current, unipolar sing surge -100mA • Tens and SP-TENS current – 140 mA • Tonolysis 100 mA • Microcurrents 1000 µA • Max. voltage in patients circuite (CV mode)-140 V • Treatment timer 30s—60 min. • The Unit Ultrasound Head Amplitude- max. 8W for 4cm² head working in continuous mode • The Unit Ultrasound Head Max 12W for cm² working in pules mode ULTRASOUND THERAPY PARAMETER • Operation Frequency- ULTRASOUND HEAD WITH ACOUSTIC WORKING FREQUENCY Of 1Mhz & 3.5Mhz with the effective radiation area – 4cm² • Effective radiating area- 4cm² • Max ultrasound intensity -continuous /pulse mode – 2/3W/cm² • Frequency in pules mode- 16 Hz/48 Hz/100 Hz 24. Duty factor in pulse mode 5-75%, step 5% • Thermal effect • 2-year warranty • CE European or FDA USA certified with ISO medical device certifications • CDSCEO Device registration certificate • Unit Supply with original Trolley and gel bottle stand and vacuum cup stand with electrode
• 7” Colour touchscreen • Peration mode: program/manual • A sensory indicator of the magnetic field activity- magnetic stripes • Treatments in dual Mode • Setting the frequency range of the magnetic field with an accuracy of 0,01 Hz • using the on- screen keyboard • Illustrated encyclopaedia with a description of treatment methodology • Field shape: rectangular modified, triangular, sinusoidal. Impulse, half rectangular • modified, semi-triangular, half-sine, half-pulse • Continuous and impulse emission • 46 built-in-treatment programs • 50 user -defined programs • The unit should Magnetic field frequency for plate applicator - 2- 120 Hz • Parameters of the intermittent mode- pulse 1 s/ pause 0,5-8 s • Frequency spectrum - 0-50 Hz • The unit supply with 2 applicator 100mT maximum value • The unit should have optionally Plate applicator CP on stand with trolley stand • The unit Should be supplying attachment - solenoid applicator CS 60 • The unit Should be supplies couch for magnetic field applicator and CS 60 • The unit should have built-in treatment programs for the upto 370 • Protective glasses for the patient - goggles (1pc.) • It should be US /European CE approved • 2-year warranty CDSCEO Device registration certificate
The Cervical & Lumbar Traction Machine shall meet the following • Should have Lumbar & Cervical Traction which is combination of Microwave & Traction Therapy with Couch Traction unit should perform static force, intermittent force, pulsation force & combination of these forces Couch should be available with proper frame to avoid any frictional errors. Microwave diathermy unit should be attachable to couch. Microwave diathermy unit should be mobile along with the traction bed. Spinal Traction Component: • Traction Force: Adjustabl
Wireless NMES
Digital Balance Assessment and Training Device
rmance multi directional castor wheels. • Should have USFDA /CE/ISO Certificates
• Connection capacity • 1-84” wall slide connect track. • 1-18” slide connect overhang track • 1-24” adjustable slide connects cross bar track. • Exercise station floor base unit. Accessories: • Resistance band exercises handle. • Resistance band assist straps. • Resistance band extremity straps. • Resistance band head straps. • Waist belt • All accessories should be attached. • Balance and core Training • 4 stability trainers • Educational Materials 1. Wall station posters
•As per user requirement
System should be portable and should operate through main power supply of 100-240 V/50Hz as well as Separate battery pack with minimum 3 hours of backup, System should be easily capable to adjust ice and Compression with reference to RICE regimen, System should have manual temperature control setting available for treatment in steps of 1 degree Celsius, System should have Temperature control from 1”C to 10”C.System should have automatic programs of 30 mins ON 30 mins OFF and should have a minimum of 10 different preprogrammed protocols + minimum 10 free protocols, so that user can do personalize program as per their choice, System should have built in purge mode to drain out water out of the wraps and main unit, Wraps should be using latest technology offering a comprehensive range of anatomically designed wraps. Wraps should consist of heat exchanger along with machine/hand washable sleeves, System should be useful for a variety of sports musculoskeletal injuries and for postoperative rehabilitation, System should have built in color or LCD display to monitor the water temperature going into the wraps, System should be supplied with following wraps:· Ankle Wrap, Large (fits men’s shoe sizes UK 8-9, US 9-10 and under for both the ankle) – 1 no. each· Straight Knee Wrap (one size should fit all for both the knee- Universal size) - 1 no. each· Half Boot Wrap, Large (Universal size)- 1 no. each· Hip/Groin Wrap, Right and Left - 1 no. each· LS Wrap and CT Spine Wrap - 1 no. each· Hand/Wrist Wrap, Flexed Elbow Wrap (one size should fit all)- 1 no. each· Shoulder Wrap, Medium, Right and left (fits chest sizes 84cm-114cm/33-45 inches) - 1 no. each· Shoulder Wrap, Large, Right, left (should fit chest sizes ranging 102cm-140cm/40-55 inches)- 1 no. each· Cooling Vest/ Cryo Vest - 1 no. each· Full Leg Boot Wrap, Large, Medium -1 no. each Should be provid
Vacuum therapy
Knee decompression machine
Heavy Duty Automatic Chiropractic Drop Table
Key Features • Multi-Channel Design: 12 channels for simultaneous stimulation of multiple acupuncture points • Adjustable Parameters: Adjustable parameters such as intensity, frequency, and pulse width to customize treatment • Pre-Programmed Modes: Pre-programmed modes for different treatment protocols, such as pain relief and relaxation • User-Friendly Interface: Intuitive interface for easy operation and programming Performance Specifications • Output Modes: Multiple output modes, such as continuous, pulsed, and modulated, to accommodate different treatment needs • Intensity Range: Adjustable intensity range, typically 0-100 mA, to suit individual patient needs • Frequency Range: Adjustable frequency range, typically 1-100 Hz, to target different therapeutic effects • Pulse Width: Adjustable pulse width, typically 50-400 μs, to customize treatment Safety Features • Electrical Safety: Designed to meet electrical safety standards, such as IEC 60601-1, to ensure patient safety • Output Limitation: Output limitation to prevent excessive stimulation and ensure patient comfort • Automatic Shut-Off: Automatic shut-off feature to prevent prolonged stimulation and reduce risk of adverse effect Additional Features • Data Storage: Optional data storage capabilities to record treatment parameters and patient data • Portability: Compact and portable design for convenient use in clinical settings • Battery Operation: Optional battery operation for increased flexibility and convenience Certifications: CE or FDA clearance
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.16 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_311319.xls
BOQ • 0.41 MB
SBD.pdf
Tender Documents • 1.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .