Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC PURATULI MALDA 732101 | MALDA | MALDA | WEST BENGAL | 732101 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹6.4 L+₹17,810 (2.86%)Rejected-AOC 39 MAHESHMATI BANK COLONI MALDA WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | L2 | Rejected-AOC Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹6.7 L+₹46,350 (7.46%)Rejected-AOC NETAJI MARKET MAHESHMATI ENGLISH BAZAR MALDA 732101 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732101 | L3 | Rejected-AOC Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹6.9 L+₹70,790 (11.4%)Rejected-Finance CHAKDAH NADIA WEST BENGAL | CHAKDAH | NADIA | WEST BENGAL | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). | |
| 5 | L5₹7.0 L+₹76,740 (12.3%)Rejected-Finance GROUND FLOOR 109 186 114 LAHIRI VILLA NEW BANSBARI MALDA WEST BENGAL 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L5 | Rejected-Finance Quoted rate found 5th Lowest (L5). |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
28 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
SITC of Split AC machines at office of the District Education officer, Samagra Shiksha Mission, Malda.
2022_WBPWD_423557_1
WBPWD/EE/MED/e-NIQ-24/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹14,000
6 Jan 2023
18 Nov 2022
30 Nov 2022
18 Nov 2022
28 Nov 2022
22 Nov 2022
Amount
S & F 415V, 100A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make: L&T)
S & F 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection with 01 nos 415 V, 100A Four Pole MCB Isolator as incomer and 12 nos 240V, 16A-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of DBs and necessary connection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to G.S. (Make: L&T / Legrand / Seimens).
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20/25mm size PVC rigid conduit 'FR' Precision make) incl. necy. fittings as required. (Make: Polycab / KEI / RR Kabel / Gloster).
(i) 2 x 4 sq. mm. + 1 x 2.5 sq. mm.
(ii) 3 x 16sq. mm. + 2 x 10 sq. mm. (Wire must be drawn through 2 Nos 25mm dia Conduit Pipe).
S & F 240 V 25A/27A stater OLP-3+ on 175mm x 100mm x 65mm sheet metal Switch Board flushed in wall and mending good the damages to original finish (For AC machine). (Make: Electron)
Supply and delivery of 1.0 / 1.1 Ton Split Type room air conditioner machine having the following specification:- (a) Star rating- 3 to 5 star. (b) Rated voltage—230v +/-5%, Frequency-50Hz. (c) Compressor type-Rotary, Condenser- Copper Coil (d) Refrigerant : R32/R410A (f) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years. [Make: O'GENERAL (ASGA12BMWA) / Daikin / Mithsubishi Heavy Duty (SRK13CRS-S6)].
Supply and delivery of 1.5 / 1.6 Ton Split Type room air conditioner machine having the following specification: (a) Star rating- 3 to 5 star. (b) Rated voltage—230v +/-5%, Frequency-50Hz. (c) Compressor type-Rotary, Condenser- Copper Coil (d) Refrigerant : R32/R410A (e) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years. [Make: O'GENERAL (ASGA18FTTC) / Daikin / Mithsubishi Heavy Duty (SRK20CSS-S6/A)].
Supply and delivery of 2.0 / 2.2 Ton Split Type room air conditioner machine having the following specification: (a) Star rating- 3 to 5 star. (b) Rated voltage—230v +/-5%, Frequency-50Hz. (c) Compressor type-Rotary, Condenser- Copper Coil (d) Refrigerant : R32/R410A (e) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years. [Make: O'GENERAL (ASGA24FUTC) / Daikin / Mithsubishi Heavy Duty (SRK25CSS-S6/A)].
Installation, Testing & commissioning of Split AC m/c with appropriate mounting kit (Air Conditioner Outdoor Unit Heavy duty mounting Bracket )& Testing of whole Refrigerant system with all joints valve etc. Including leak testing, flushing at different time by dry N2 incl. Supply & filling of refrigerant gas.
Supply and installation of Extra Copper pipe of following dimension for connection between IDU & ODU of Split / Tower AC machines.
(i) 5/8" Copper Pipe.
(ii) 1/4" Copper Pipe.
S & F of nitrile rubber tube Insulation on suction/liquid line copper pipe of Split/ Tower AC machines.
(i) Liquid Line.
(ii) Suction line.
S & F of 3 Core 4 sq.mm. PVC 'FRLS' Cu cable for connection between indoor & outdoor units. (Make: Polycab / Finolex / Havells).
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate for AC machine will have to be submitted during delivery of the material.
GITANJALI ELECTRONICS AND ELECTRICALS
INDIAN SERVICE
ROY REFRIGERATION
M/S EASTERN ENGINEERING
M/S. M. R. ENTERPRISE
technical_836941.pdf
PDF • 0.09 MB
techsummary_836941.pdf
PDF • 0.40 MB
finance_836941.pdf
PDF • 0.09 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_836941.pdf
PDF • 0.64 MB
AOC.pdf
PDF • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .