Managing Director, HPMC
HPMC HO Nigam Vihar Shimla
Design, supply, installation and commissioning of Processing plant and machinery and trial runs including construction of processing plant for Parala, District. Shimla HP
2020_HPMC_37798_1
HPHDP PIU HPMC / TURNKEY/ PARALA-20
Open Tender
Civil Works - Others
540 days
Parala, Distt. Shimla
Please refer Tender documents.
12 documents required · 12 mandatory
₹5,900
Project Director
₹1.7 Cr
HPMC Shimla through Video Conference.
17 Dec 2020
3 Jun 2020
24 Jul 2020
3 Jun 2020
24 Jul 2020
14 Jul 2020
3 Jun 2020 - 22 Jun 2020
26 Jun 2020
Amount
Schedule No.1 : Plant (including Mandatory Spare Parts) Supplied from Abroad as per ITB 17.5 PACKAGE A: PLANT AND MACHINERY *Note:- ( Qty as 1 Lot means price for complete section/plant /services/spare parts as applicable )
Process Plant: AJC Plant:- a) Apple Reception and Washing including Pipe Fittings and valves, supports Set of Instrument,
b) Grinding and Mash Conditioning including Pipe Fittings and Valves, supports Set of Instrument,
c) Pressing Area including Pipe Fittings and Valves, supports Set of Instrument,
d) Centrifuge including Pipe Fittings and Valves, supports Set of Instrument, In case of Belt Press)
e) Filtration Juice Treatment including Pipe Fittings and Valves, supports Set of Instrument, (Ultrafine Filtration)
f) Evaporation Plant with Aroma Recovery Column including Pipe Fittings and Valves, supports Set of Instrument,
g) Aseptic Sterilizer and Double Head Filler including Pipe Fittings and Valves, supports Set of Instrument,
h) Centralized CIP system including Pipe Fittings and valves, supports Set of Instrument,
i) Electricals, Control system and automation for process section. Including cable trays, power cables, control cables, conduits, etc.
Process Plant: Ready to Serve Drink with Filling Line: Ready to serve drink with filling line (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Vinegar processing Line with Filling System:- Vinegar Processing Line with Filling Line of Capacity 50,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Wine Processing Line with Filling System:- Processing Line Wine Processing Line with Filling Line of Capacity 100,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Pectin Extraction Plant:- Pectin Extraction Plant of Capacity 40 TPD (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Utilities and Miscellaneous Items:- a) Steam Boiler (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.),
b) Refrigeration Plant: Cooling tower and its piping complete with pumps (3 operative and 1 standby pump)
c) Refrigeration Plant: Chilled water system (Chiller with pumps and line- 1 operative and 1 standby
d) Air Compressor, oil free, moisture free
e) R.O. Plant with storage tank/supply system
f) Water Treatment Plant
g) Common Effluent Treatment Plant
h) Cold Storage
i) Laboratory (Lab Equipments)
j) Material Handling Equipments
k) Electricals and DG Sets
l) Integration Piping
m) Any other items which is not mentioned above
Schedule No 2 - Plant & Machinery Spare Parts Manufactured in India PACKAGE A: PLANT AND MACHINERY Process Plant: AJC Plant:- *Note:- ( Qty as 1 Lot means price for complete section/plant /services/spare parts as applicable )
a) Apple Reception and Washing including Pipe Fittings and valves, supports Set of Instrument,
b) Grinding and Mash Conditioning including Pipe Fittings and Valves, supports Set of Instrument,
c) Pressing Area including Pipe Fittings and Valves, supports Set of Instrument,
d) Centrifuge including Pipe Fittings and Valves, supports Set of Instrument, In case of Belt Press)
e) Filtration Juice Treatment including Pipe Fittings and Valves, supports Set of Instrument, (Ultrafine Filtration)
f) Evaporation Plant with Aroma Recovery Column including Pipe Fittings and Valves, supports Set of Instrument,
g) Aseptic Sterilizer and Double Head Filler including Pipe Fittings and Valves, supports Set of Instrument,
h) Centralized CIP system including Pipe Fittings and valves, supports Set of Instrument,
i) Electricals, Control system and automation for process section. Including cable trays, power cables, control cables, conduits, etc.
Process Plant: Ready to Serve Drink with Filling Line:- Ready to serve drink with filling line (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Vinegar processing Line with Filling System:- Vinegar Processing Line with Filling Line of Capacity 50,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Wine Processing Line with Filling System:- Processing Line Wine Processing Line with Filling Line of Capacity 100,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Pectin Extraction Plant:- Pectin Extraction Plant of Capacity 40 TPD (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Utilities and Miscellaneous Items:- a) Steam Boiler (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.),
b) Refrigeration Plant: Cooling tower and its piping complete with pumps (3 operative and 1 standby pump)
c) Refrigeration Plant: Chilled water system (Chiller with pumps and line- 1 operative and 1 standby
d) Air Compressor, oil free, moisture free
e) R.O. Plant with storage tank/supply system
f) Water Treatment Plant
g) Common Effluent Treatment Plant
h) Cold Storage
i) Laboratory (Lab Equipments)
j) Material Handling Equipments
k) Electricals and DG Sets
l) Integration Piping
m) Any other items which is not mentioned above
Schedule No 3 - Design Services PACKAGE A: PLANT AND MACHINERY Process Plant: AJC Plant:- *Note:- ( Qty as 1 Lot means price for complete section/plant /services/spare parts as applicable )
a) Apple Reception and Washing including Pipe Fittings and valves, supports Set of Instrument,
b) Grinding and Mash Conditioning including Pipe Fittings and Valves, supports Set of Instrument,
c) Pressing Area including Pipe Fittings and Valves, supports Set of Instrument,
d) Centrifuge including Pipe Fittings and Valves, supports Set of Instrument, In case of Belt Press)
e) Filtration Juice Treatment including Pipe Fittings and Valves, supports Set of Instrument, (Ultrafine Filtration)
f) Evaporation Plant with Aroma Recovery Column including Pipe Fittings and Valves, supports Set of Instrument,
g) Aseptic Sterilizer and Double Head Filler including Pipe Fittings and Valves, supports Set of Instrument,
h) Centralized CIP system including Pipe Fittings and valves, supports Set of Instrument,
i) Electricals, Control system and automation for process section. Including cable trays, power cables, control cables, conduits, etc.
Process Plant: Ready to Serve Drink with Filling Line: Ready to serve drink with filling line (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Vinegar processing Line with Filling System:- Vinegar Processing Line with Filling Line of Capacity 50,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Wine Processing Line with Filling System:- Processing Line Wine Processing Line with Filling Line of Capacity 100,000 Liter Per Annum (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Process Plant: Pectin Extraction Plant:- Pectin Extraction Plant of Capacity 40 TPD (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.)
Utilities and Miscellaneous Items:- a) Steam Boiler (for complete section including tanks, pumps pipes, fittings, valves, electricals, instrumentation and automation, etc.),
b) Refrigeration Plant: Cooling tower and its piping complete with pumps (3 operative and 1 standby pump)
c) Refrigeration Plant: Chilled water system (Chiller with pumps and line- 1 operative and 1 standby
d) Air Compressor, oil free, moisture free
e) R.O. Plant with storage tank/supply system
f) Water Treatment Plant
g) Common Effluent Treatment Plant
h) Cold Storage
i) Laboratory (Lab Equipments)
j) Material Handling Equipments
k) Electricals and DG Sets
l) Integration Piping
m) Any other items which is not mentioned above
PACKAGE B : CIVIL WORKS Scope of Design for up–gradation, expansion and strengthening of existing post-harvest infrastructure project at PARALA, district SHIMLA (HP)” shall conform to the detailed technical specifications and performance parameters given therein in package B *Note:- ( Qty as 1 Lot means price for complete section/plant /services/spare parts as applicable )
Schedule No.4 : Installation Services as per ITB 17.5 *Note:- ( Qty as 1 Lot means price for complete section/plant /services/spare parts as applicable )
Packing Charges, (seaworthy packing for supply items from abroad)
Supervision of Installation and Commissioning
Complete Installation and Commissioning activity covering mechanical, electrical, instrumentation, automation etc.
Local Transportation for Plant from abroad
Local Transportation for Plant from employer’s country
Schedule No.5 :Civil Work as per ITB 17.5 Construction of Food Processing unit at Parala
Clearing jungle including uprooting of rank vegetation, grass,brushwood, trees and saplings of grith upto 30 cm. measured at a height of 1 metre above ground and removal of rubbish upto a distance of 20 metres outside the periphery of the area cleared:
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
Earth work in excavation for structure as per drawing and technical specification clause 305.1 I/c setting out,construction of shoring and bracing removal of stums and other deletarious materials and disposal upto a lead of 50 metre, dressing of sides and bottom and back filling in tranches with excavated suitable material.
Loosening of the ground upto a level of 300 mm below the subgrade level,watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto a 1.5 metres. Spade Work.
Filling of available earth
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm.layers, when required in to plinths sides of foundations etc.,consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres.
P/L Cement concrete 1:6:12 ( one cement : six sand : twelve graded stone aggregate forty millimeter nominal size)for plain/ reinforced concrete work in open foundation complete as per drawing and technical specification Clauses 802,803,1202& 1203.
Providing and laying cement concrete 1:5:10 (1 cement:5 sand:10 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in:
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203. 1:3:6 ( For Sub Structure)
Providing weepholes in brick masonry/stone masonry/plain reinforced conrete abutment,wing wall, return wall with 100 mm dia. PVC pipe extending through the full width of the structures with slope of 1(v) : 20 (H) towards drawing face complete as per drawing and technical specification clauses 614,709,1204.3.7.
Back filling behind abutment,wing wall and return wall complete as per drawing and technical specification clause 1204.3.8 granular material.
Making plinth protection with flag stone flooring 40 mm thick over a bed of 15cm with rammed earth and cement pointing 1 : 3 (1 Cement : 3 Sand) in proper shape as per instructions of the Engineer Incharge.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth:
Providing and laying cement concrete 1:2:4(1 cement:2 sand :4 graded stone aggregate 40mm nominal size)and curing complete excluding cost of form work:
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement:2 sand:4 stone aggregate 12.5mm nominal size) and curing complete.
Providing mild steel / Tor steel reinforcement for RCC work including bending , binding and placing in position complete upto floor two level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work in grating, framed guards, bars, ladders raillings, brackets & similar works
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shuutering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu-reinforced concrete & plain concrete work in: Foundations,footings,bases of columns etc. and mass concrete.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters,buttresses,plinth and string courses and the like.
Square,rectangular,polygonal in plan.
Providing concrete for plain/reinforced concrete 1:4:8 complete as per drawing and tecnical specification clauses 802, 803, 1202 & 1203.
Providing and laying cement concrete 1:1:2 (1 cement : 1 Sand : 2 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work. Foundation and plinth.
Independent piers columns and pillars upto floor two level
Lintels beams, girders, brassumers and cantilevers upto floor two level etc
Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate 20mm. nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers upto floor two level.
Providing and laying cement concrete 1:1.5:3 (1cement :1.5 sand :3 graded stone aggregate 20mm. nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work
Brick work using common burnt clay building bricks in foundation and plinth in :- Cement Mortar 1:5 (1 cement : 5 sand) First Class Bricks
Brick work using common burnt clay building bricks in Superstructure above plinth level in Cement Mortar 1:3 (1 Cement : 3 Sand). First Class Bricks as per the directions of Engineer-in-Charge
Super-structure above plinth level upto floor two level (First Class Bricks)
Half brick masonry in common burnt clay building bricks in cement lime mortar 1:1:6
15mm Cement plaster in single coat on the rough side of brick/ concrete/stone walls for interior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth..(ii) Cement mortar 1:4 (1 cement:4 sand)
10mm cement plaster in single coat on fair side of brick/concrete walls for internal plastering upto floor two level including arrises, internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.(ii) Cement mortar 1:4 (1 cement:4 sand)
6mm Cement plaster to ceiling In Cement mortar 1:3(1 Cement:3 Sand)
Consolidation in layer of 300 mm with road roller including making good the undulation etc. with earth or quarry soil etc. and rerolling the sub-grade completed as per HP.PWD specifications
Construction of granular sub base by provoding coarse graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibrator roller to achieve the desired density, complete as per clause 401 as per technical secification
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Preparation of sub grade by dressing to combor (Earth work for the cutting involved for subgrade to be paid for separately depending upon the classification of soil completed as per HP.PWD specifications..
Stone soling properly handpacked filling interstices with spalls and consolidating with power road roller to the requested gradient and comber including spreading watering and rolling of binding materials moorum or earth etc. complete as per HP.PWD specification. 100 mm spread thickness (finished work including materials and labour)
Construction of granular subbase by providing well graded material, spreading in uniform layers with Tractor mount grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Clause 401 For Grading I Material
Construction of unreinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted
Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.
Providing and fixing in position pre-moulded joint filler in expansion per cm depth joints. Size is 5cm x 10cm
Kota stone slab flooring 25 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete. 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles Nitco or equivalant 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete
Providing and laying granite stone in flooring 20mm(average)thickness base of cement mortar 1:3(1cement: 3 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of granite stone i/c rubbing and polishing complete. 20mm.thick
Providing and laying heavy duty precast cement conrete inter locking paver blocks vibro compacted upto M50 grade i/c border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete (Sub base concrete floor to be paid for 60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying 20mm. thick acid proof tiles of size upto 300 x 300mm. of specified shade in floors, treads of steps and landing laid on a bed of 12mm. thick acid proof mortor 1:3(1 cement: 3 sand) jointing with cement slurry mixed with pigment to match the shade of tiles.
Applying priming with cement primer coat on newconcrete/masonry/asbestos cement/plastered surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matter and sand papering as required as directed by Engineer-in-Charge
Painting or varnishing on iron works in small areas with one coat of ready mixed peiming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc required for proper completion of work. Paint to be used should confirm to the ISI no. 1031950
Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equarlied on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand paper smooth complete.
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete
Applying one coat of AcrylicWashable emulsion Spectrum quartz king or equivalent finish for interior painting with brushes plain smooth finish composed of acrylic polymere in emulsion inorganic/special pigment siliceous aggregate anti fungicides anti-rusting & foaming in two coat i/c necessary putty to give smooth even surface, sand papered smooth complete.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing Chain link fabric fencing mesh of size 50x50 mm made of G.I. wire of dia 4 mm
Providing barbed wire on the existing barbed wire fencing with seven strands of barbed wire 12 S.W. G.x 2pliesx 4 points at 75mm apart including supplying, fitting and fixing with galvanised staples 38mm x 38mm x 3mm sizes with existing posts of the fencing, including removing rotten barbed wire as directed, complete with strengthening of post and tightening of the old barbed wire and joinining old serviceable pieces on remaining lines as and where necessary and as directed.
Providing corrugated G.I sheet .80 mm thick roofing fixed with galvanised iron J.or L. hooks bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white lead complete excluding the cost of angles
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentrationconcentration for preconstructional anti-termite treatment by uniformly spraying and injecting the diluted water Emulsion in specified quantities under and alround the column pits, water trenches, top surface of plinth filling, junctions of walls and floor, along the external perimeter of the building expansion joints, over the top surface of excavated earth on which Apron is to be laid, surroundings of pipes and conduits etc. to create a continuous chemicals barrier complete as per standard specifications.
Providing and fixing anodised aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fittings
Glazing with glass panes of 5.50mm thickness (weight not less than 13.75 kg/ sqm.
Providing and fixing flush door shutters decorative type core of block board construction with frames of first class hard wood and well matched first class indian teak plyveneering with vertical grains or cross bends and face vencering on both faces of shutter 40mm thick including black enamelled M.S. butt hinges
Providing and fixing aluminium tower bolts (berrel type) anodized trans parent or dyed to required shade and colour with screws etc. complete 250x10mm
Providing and fixing aluminium handles anodized transparent or dyed to required colour shade with necessary screws etc. complete.
Particle board (bwp phenol bonded exterior/interior grade) 8mm thick (mezzanine)
Providing & fixing 2.5m (W) x 4.00m (H) x100 mm Thick Motorized Sliding Door for Chillers chambers with imported hinges, lock, sliding rails and AL channel all across door, Wing injected by polyurethane CFC free 40 Kg/mc of density, Wing edges in aluminium , wing covered by white plastic coated zinc plate metal sheets, Double EPDM gasket, Upper rail in aluminium, Lower rail apply on panel, With heated threshold to be fitted into the floor, Heater cable apply on frame into an housing in aluminium, Flat frame in grey pvc with nylon tension rods for panel application without bended metal sheets to cover the panel opening including cost of silicon curtain complete as described in specifications & as desired by Engineer-in-Charge..
Providing & fixing Overhead Sectional sliding doors of size 2.5m x 3m model IP600, consisting of insulated sandwich panels 600 height, visible internal hinges, stucco finishing with horizontal grooves, painted on galvanized base, 40 mm thick polyurethane foam insulation; no. 2 Inspection windows 660 x 355 mm installed on the third panel upon request. Internal standard colour RAL 9002; external standard colour Ral 9002 Cables and springs break safety devices included. Motorised system for sectional doors (SMFDU2): Motor drive operating system with “Dead Man’s” logic automation, providing: Electromechanical Three-phase motor usable with a system directly splined to the torque shaft and an “on board” control card; Inside motor unblocking device; 2 (two) interlocked “Open-Close” buttons; Flashing light indicator. Quantity -Type- Dimensions – Necessary Lateral spaces No.2 including cost of silicon curtain complete as described
Providing and fixing roofing/wall clading with PPGL sheets 0.5mm thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATA-LYSAGHT /JSW-COLORN or equivalet, fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge
Providing and Fixing of 3mm thick polycarbonate sheet 1st quality in any shape and size fixed with self-drilling machine screw/nut/bolt and washer,all joint to be filled with silicon for leak proofing complete in all respect as per drawing and entire satisfactio of engineer- in - charge.
Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATALYSAGHT/JSW-COLORN or equivalet,t, fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.
Providing and fixing Gabble fashing 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATA-LYSAGHT/JSW-COLORN or equivalet,t, fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge
Providing and fixing Corner flashing 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATA-LYSAGHT/JSW-COLORN or equivalet,t, fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.
Providing and fixing Crimped Eave 3'-6" wide with PPGL 0.50 thick (TCT) manufactured from zinc /aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATA-LYSAGHT/JSW-COLORN or equivalet,fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge
Providing and fixing plain ridge covering 450mm wide with PPGL 0.50 thick (TCT ) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour Make TATA-LYSAGHT/JSW-COLORN or equivalet, fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge
Providing and fixing of Terboventilator size 600mm high, 2540 mm perimeter weight 6.60 kg made of shaft 16mm dia M.S bar crome plated, Fins made of aluminium Top plate and bottom ring made of stainless steel 304 grade, base of fibre UV rays stablilzed STD quality size 2mtr x 1mtr weight 8.5 kg including cost of fixing arrangement complete in all respect and to the entire satisfaction of Engineer-inCharge.
Providing and fixing on wall face PVc (D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive complete. 100mm dia pipes
Providing fabrication and erection of Pre-Engineering steel structure (Hot rolled/Cold rolled), fabricated from plate, Pipes,Rod and angle of various sizes shall have flanges and web jointed on single side of the web by a continues welding process, other side welding 150mm long @ 600mm center to center and will conform to the physical specification of ASTMA 572 Shade-50 Type-I and having minimum yield strength of 345 MPA/ASTM A36/IS 2062 or equivalent and having a minimum yield strength of 245 MPA including one coat of zinc cromate primer & two coat of painting complete in all respect and tothe entire satisfaction of engineer in charge
Providing and erection of High strength bolts conform to physical specification of ASTM A 325M class 8.8 type 1 & Anchor bolts confirm to the physical specification of ASTM A 36M/IS 2062 and having a minimum yield strength of 245 MPA duly coated with Zinc Cromate Primer complete in all respect and to the entire satisfaction of engineer in charge
Providing and fixing pre fabricated Puff Panneled walls, ceiling & Insulation under floor including insulated doors Providing & fixing Pre-fabricated puff Panels 100mm Thick in wall Panels for chilled chamber having cam lock arrangement or tounge and groove arrangement with 0.5mm (TCT) thick PPGL sheet both sides, including flashing, support hanging rod, hat channel, silicon sealents etc for Refrigerated facility complete as described in specifications & as desired by Engineer-in-Charge..
Providing & fixing Pre-fabricated puff Panels 100mm Thick in ceiling Panels for chilled chamber having cam lock arrangement or tounge and groove arrangement with 0.5mm (TCT) thick PPGL sheet both sides, including flashing, support hanging rod, hat channel, silicon sealents etc for Refrigerated facility complete as described in specifications & as desired by Engineer-in-Charge..
Providing & Laying Pre-fabricated puff Slabs 100mm (60mm+40mm in 2 layer) Thick in flooring having cam lock arrangement or tounge and groove arrangement silicon sealents etc insulation with two layers bitumin and and two layers of tarfelt for frozen chambers complete as described in specifications & as desired by Engineer-in-Charge.
Providing & fixing Pre-fabricated puff Panels 80mm Thick in ceiling Panels for loading, unloading, ante room and ripening chamber area having cam lock arrangement or tounge and groove arrangement with 0.5mm(TCT) thick PPGLsheet both sides, including flashing, support hanging rod, hat channel, silicon sealents etc for Refrigerated facility complete as described in specifications & as desired by Engineer-in-Charge
Providing & Laying Pre-fabricated puff Slabs 80mm (40mm x 2 layer) Thick for floor insulation with two layers bitumin and and two layers of tarfelt of 0.5mm thick for loading, unloading, ante room and ripening chamber (This to be finished by VDF of 150mm thick, the VDF item rates are to be quoted in civil works BOQ) complete as described in specifications & as desired by Engineer-in-Charge.
Supplying & Fixing of Puddle collar/ vent pipe (150 DN Air Vent) as per drawing and as approved by Engineer-in-Charge.
Providing and fixing in RCC tank MS or GI insert with flanged / threaded ends 500mm to 600mm long including puddle flange, required no of companion flanges, bolts, nuts, rubber gaskets,a thick coat of non-setting mastic or plastic cement etc all complete. The contractor is responsible for leak proof puddle pipes inserted in the tank. Inlet 150/160mm dia
Outlet 150/160mm
65 mm dia
100 mm dia
200 mm dia
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.1
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD - 35 Circular shape 560 mm internal dia.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All type of soil 300mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150mm dia
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter
Structural glazing Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels:
SIGNAGE - Providing and fixing backlit signage of acrylic based material , including fixing with necessary accessories , with arrangement of light ( light fixture by contractor ), complete in all aspect , as directed by engg- incharge . Scaffolding ( included ) ( size - of letter is around 300- 450 mm, atleast 10-12 nos of letter )
"Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc.
ELECTRICAL SUB LT PANEL (Landscaping & External Lights),Location New Guard House Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of light conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Aluminium/GI earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- INCOMING SUPPLY FROM NEW GATE HOUSE PANEL: 1 No. 125 A, 4P (100% Neutral) MCCB (36 kA) with Microprocessor based O/L, S/C and E/F releases. METERING & INDICATING LIGHTS 1 Nos MFM Meters 1 Set of 150/5A, CL-1, 15VA CTs for measuring. Sets of phase indicating ,ON/OFF,TRIP Indicating lamps with 2A control MCBs. BUSBAR: Electrolytic high conductivity TPN (100% Neutral) Aluminium busbars rated at 200 amps (25 kA) with heat shrinkable PVC sleeves. OUTGOING FEEDER: 3Nos.32 A DP MCB . 2Nos.32 A TPN MCB with Timer for LANDSCAPING & EXT. POLE LIGHTS . 2Nos.32 A TPN MCB with Timer for LANDSCAPING & EXT. POLE LIGHTS . 2Nos.63 A TPN MCB with Timer for LANDSCAPING & EXT. POLE LIGHTS .
CABLING WORK (SUPPLY) Supply of following size of XLPE / PVC insulated,PVC Sheathed, Aluminium Conductor armoured power cable of 1.1kV grade etc. as required. 3.5C x 70sq.mm 1.1kV Al Cable
4C x 10sq.mm 1.1kV Al. Cable
4C x 6sq.mm 1.1kV Al. Cable
LAYING OF CABLES : Laying of one number XLPE / PVC insulated,PVC Shethed armoured power cable of 1.1kV grade of following sizes on perforated cable trays and dressed using cable ties and identified at regular intervals as required./in Existing RCC/HDPE Pipe/Masonary/Trusses etc 3.5C x 70sq.mm 1.1kV Al Cable
4C x 10sq.mm 1.1kV Al. Cable
4C x 6sq.mm 1.1kV Al. Cable
Laying of one numberXLPE / PVC insulated, PVC sheathed Aluminium Conductor Armoured power cable of 1.1kV grade of following sizes in ground including excavation and backfilling and identified at regular intervals as required. 3.5C x 70sq.mm 1.1kV Al Cable
4C x 10sq.mm 1.1kV Al. Cable
4C x 6sq.mm 1.1kV Al. Cable
LT CABLE TERMINATION End termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 70sq.mm 1.1kV Al Cable
4C x 10sq.mm 1.1kV Al. Cable
4C x 6sq.mm 1.1kV Al. Cable
LANDSCAPING & STREET LIGHT : STREET LIGHT POLES 7 MTR Galvanised: Supply , fixing, Testing & Commissioning of 4.5 mtr long,3mm thick sheet,hot dip galvanised poles of bottomdia 130mm/70mm respectively with base plate diamensions 220X220X14 mm with galvanised Single Arm Bracket of 1.00 mtr length. The pole shall be Errected on a suitable size of Cement Concreate 1:2:4 foundation as per Manufacturers standards along with Grouting the Foundation Bolts,nuts and 1.5 mtr long,50 mm dia suitably bend ,GI ,Medium Class Pipe for cable entry, suitable size Inbuilt Cable End Box opening approx.600 mm above the Pole Base with 2 Nos. 6Way 15 Amp, Bakelite Connectors,1 No 6 Amp, SP MCB C Curve etc as required. The door shall be vandal resistant and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. The poles shall be complete with integral terminal boxes, MCB cut-outs, pole foundation bolts, lightning arrestor, earthing, etc. as required. The poles shall have provisions for mounting and connecting an additional 250 Watt MH -type outdoor light fitting
POST TOP LANTERNS: Supplying , Fixing, Testing & Commissioning of Post Top Lanterns of 40 Watt LED Light Fixtures,IP-65 Housing,made of single piece Die Cast Aluminium alloy,as per Manufacturers design.on a suitable length & Dia of GI Pipe
BOLLARDS Along Path Ways: Philips,LED Bollards,BCP-1510, 8Watts,IP-65,Warm White Colour,temp.3000K on 500mm high Rotomoulded LLDPE Pillars duly grouted on a concreate base by means of 4 Nos. M8X75 mm studs with necessary base rings (CatIII)
SPIKE LIGHTS,Garden Tree/Planter Illumination: Philips make smart,Bright spot light BGP-150,LED 250/WW,6 watt,20 D,corr. Colour Temp.3000K
Wall LightS: Philips make,Tempo LED, wall ligths, system wattage (10-16),IP-65,Colour Temp.5700K on a suitable height as per Designer/Consultants.
STRIP LIGHTS for Street Furniture: Philips LED Strip light ,12 Watt,Warm White, Colour Temp.3000K,Operating Voltage 220/24 Volts on wall surface/floor etc as reqd. as per drawings etc
FLOOR LIGHTS: Philips make,Floor lights LED, 1Watt,IP-67,40 lumen output,warm white,Colour Temp.3000K operating voltage 220/24 volts. Designer/Consultants.
pole Lights for 4.5 mtr Poles: 60 Watt,LED pole light complete in all respect , including 60 Watt LED Lamp,etc as required.
WI-FI ROUTERS : Providing wifi routers at diffirent locations as per requirement of designer/consultant.
EARTHING SYSTEM Supply, installation and connecting a Copper CHEMICAL EARTHING SAFE EARTH ELECTRODE 50MM DIA 3 Mtrs earthing electrode with non corrosive hygroscopic Backfill compound The cost of digging and back filling earth electrode as per IS 3043-1987.at a depth of 2000 mm. A masonary strucutre shall be constructed to a depth of 750mm. and a heavy duty CI Cover shall be used to cover the pit. Earth resistance with in 1 ohm. as per requirements of local authorities, With15 years warranty including Masonary chamber with locking arrangements. for Low Voltage & Data Network
Supply, installation and connecting a GI CHEMICAL EARTHING SAFE EARTH ELECTRODE 50MM DIA 3 Mtrs earthing electrode with non corrosive hygroscopic Backfill compound The cost of digging and back filling earth electrode as per IS 3043-1987.at a depth of 2000 mm. A masonary strucutre shall be constructed to a depth of 750mm. and a heavy duty CI Cover shall be used to cover the pit. Earth resistance with in 1 ohm. as per requirements of local authorities, With 15 years warranty including masonary chamber for Body Earthing
Supplying and installation of following sizes of earth strip & wires by using spacer clamp for main earth flat,suitable clamping with M.S / Cu. flats for earthwires etc.,including terminal crimping type sockets,bolts & washers, etc required for the complete job. 25x 6 mm CU strip.on surface or as required.
25 x 6 mm GI strip on surface or as required.
Provinding and fixing 6 SWG GI wire on surface are in recaes for loop earthing long with existing conduit / cable as required
INTERNAL ELECTRICITY WIRING IN PVC CONDUIT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm +1 X6 Sq. mm earth
4 X 10 sq. mm +2 X6 Sq. mm earth
4 X 16 sq. mm +2 X6 Sq. mm earth
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 240 V,32/20A Industrial plug socket with SP MCB in a suitable MS BOX
INSTALLATION OF FIXTURES & FANS Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation, testing and commissioning of Fresh Air Fans on Walls , including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing suitable MS box etc. as required.
CONDUITING & WIRING OF T.V. , TELEPHONE and LAN SYSTEM Supplying and drawing following pair 0.5 sq. mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair (4 core) From LV box to different point
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Providing, laying connecting and testing of multi-core telephone armored/ unarmored cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 20 Pair telephone armored cable
Providing, fixing connecting and testing of under noted size of solder less telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 20 pair tag block
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia conduit pipe
32mm dia conduit pipe
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Supplying and fixing M.S. box with modular type telephone (RJ-11) outlet complete as required.
Modular Type DATA ( RJ-45) outlet complete as required
Supplying & Fixing of UTP Jack Panel, loaded with 48 no's UTP ports for Non-PCB based IO Jacks (RJ45, TIA-568C Category-6, Shall have integrated bonding bar or other mechanism for grounding, Shall be loaded with individually replaceable 24 nos. Category-6 certification by Jacks complying with TIA-568.C.2 , Shall be having a 6 port module construction for better cable dressing at the rear, the jacks shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable complete in all respect.
Supplying & Fixing of Floor Standing Network/Server Rack - 42U / 800w / 800d, with Heavy Duty Extruded Aluminum Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capacity of 500Kgs. Side Panels - 42U/800d Front MS Door Perforated honeycomb 42U/800w Rear MS Door Split Perforated honeycomb 42U/800wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U Shelf, Stationery 700mm N/W PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 1U MS with Loops complete in all respect
Providing & fixing Electrical fittings for guard room
Supplying Installation testing and Commissioning of 48 port 10/100/1000BASE-T ports POE switch and four GbE/10GbE SFP/SFP+ uplink ports, layer 3 from day1 having static & RIP ,stackable up to 10 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in all respect
MODULAR BOXES & SWITCH/SOCKETS Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
CHAPTER-2-MCCB, MCB & DB'S Providing and fixing following rating and breaking capacity and pole MCCB with THERMOMAGNETIC RELASE AND TERMINAL spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
63 A,36KA,FPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required but without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 Ma in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 4 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Supply & Installation of Light Fixtures & Fans and CCTV camera Supply of Following type of Fans & Fixtures of all sizes and shapes LED lamps per fitting, complete with all accessories. 24 W LED Light Fixtures as marked L1
18 watt LED Down Lighters as marked L2.
12 watt LED Down Lighters as marked L4.
Mirror Light 11W LED
Ceiling Fans 48” dia on ceiling without Regulator .Including GI Down Rod as required.
Exhaust fans.med.duty for Toilets
High Bay LIGHTS 60 Watts
HIGH BAY LIGHTS 90 Watts
Fresh Air Fans on wall
CCTV Camera with panelling and fitting
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq. ft. complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation,testing & Commissioning of addressable fire control module complete as required.
Supplying,Supplying, installation, testing & commissioning of addressable phone control module as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supplying,Supplying, installation, testing & commissioning of addressable mannual call point complete as required.
Supplying,Supplying, installation, testing & commissioning of addressable horn cum strobe as required
Supplying,Supplying, installation, testing & commissioning strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
PUBLIC ADDRESS SYSTEM Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying,Supplying, installation, testing & commissioning ceiling of /wall mounted loud speaker, 3/1.5 Watt in ABS enclosure as required.
Supplying, installation, testing & commissioning of 6 inchesdia, 2 watts, 70/100 volts ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assemblycomplete as required.
ASPIRATION DETECTOR ACCESSORIES Supply, installation, testing and commissioning of 25 mm Outer dia CPVC Pipe with end caps including making air sampling opening ofappropriate dia on appropriate interval and all accessories as required.
SUBSTATION EQUIPMENT 3 PANEL, 11 KV ,VCB PANEL BOARD) Location SS Block
Battery Charger With Battery Bank Supplying, installation, testing & commissioning of Battery charger with Battery Bankwith 415 Volt AC input & 110 Volt DC continuous output suitable for closing/ tripping/indication of HT panel boards with 55 Nos. 2 Volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter & Voltmeter i/c connections with 4.0 sq. mm FRLS insulated copper conductor cable etc. as required.
Transformer 1MVA (1000KVA): (ONAN TYPE): Supply, Transporting,Receiving,Unloading, Shifting, Installation, Testing & Commissioning of 1 MVA,1000KVA 11kV/433 Volts, Copper wound ONAN Stepdown power transformer with Off Load circuit tap changer with tapping range @ -10% to +10% in steps of 2.5% with all tapings shall be on high Voltage Side as per IS 11171& IS 2026. The transformer shall have HV cable box, LV side suitable for 2000Amp Al.Sandwich Bustrunking with Adopter box to Accomodate Bustrunking. weatherproof marshalling box,Buccholtz Relay, OTI and WTI with trip and alarm contacts. with all accessories as mentioned in specification.
MAIN LT PANEL : PHASE-1 (SUBSTATION BUILDING) Supply,Transporting,Receiving,Unloading,Shifting,installation, testing and commissioning of cubical type LT Panel suitable for 415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in compartmentalized CRCA sheet steel of 2 mm thick for frame work& Doors etc and 3 mm thick gland plate i/c. cleaning and finishing complete with Seven Tank Process for powder coating in approved shade, having 3200 Amp. capacity extensible type 4-Pole Aluminium alloy bus-bars of high conductivity, DMC/SMC bus bar supports with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Al. earth bar of size 50mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Alu. busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half i/c. providing following switch gears :- Incoming : 2 Nos 1600Amp ACB: from 2 Nos. 1MVA Transformers Each Incomer ACB comprising of Following mountings& Accessories:- 1 Nos. 1600 Amps, Four pole horizontal drawout type Air Circuit Breaker(ACB)of fault breaking capacity 65 KA (Ics=100%Icu=Icw(1sec.)) EDO, with inbuilt over current, short circuit, earth fault microprocessor release and display unit. Under voltage release fitted with door interloack, Power Metering, Harmonic Metering & Communication ,Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS/IEC : 60947-2 as amended upto date complete with following accessories for each ACB. Independent electrical and mechanical spring closing mechanism - Digital Multifunction meter with RS 485 port , 96 mm square flush pattern digital type Multi function Meter MFM , one set of 3 Nos. CTs of ratio 1600 /5A Class-I accuracy & 15 VA burden -3 Nos. Phase indication LED Lamps with 2 Amp. Back up MCBs, including breaker ON, OFF indications. Complete set as above required for 2 Nos. ACBs as INCOMERS from Transformer . I Incoming 3 Nos. 800Amp ACB From 2 Nos. 500KVA DG Sets & One Number 250 KVA Existing DG Setconnected with this panel Each Incomer ACB comprising of Following mountings& Accessories:- 1 Nos. 800 Amps, Four pole horizontal drawout type Air Circuit Breaker(ACB)of fault breaking capacity 65 KA (Ics=100%Icu=Icw(1sec.)) EDO, with inbuilt over current, short circuit, earth fault microprocessor release and display unit. Under voltage release fitted with door interloack, Power Metering, Harmonic Metering & Communication ,Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS/IEC : 60947-2 as amended upto date complete with following accessories for each ACB. Independent electrical and mechanical spring closing mechanism - Digital Multifunction meter with RS 485 port , 96 mm square flush pattern digital type Multi function Meter MFM , one set of 3 Nos. CTs of ratio 800 /5A Class-I accuracy & 15 VA burden -3 Nos. Phase indication LED Lamps with 2 Amp. Back up MCBs, including breaker ON, OFF indications. Complete set as required for 3 Nos. ACBs as INCOMERS from DG Sets
Bus Couplers : 1 NO :- 1600 Amps & 2 NOS 800 AMPS, Four pole horizontal drawout type air circuit breaker of fault breaking capacity 65 KA (Ics=100%Icu=Icw(1sec.)) EDO, with inbuilt over current, short circuit, earth fault microprocessor release and display unit. Under voltage release fitted with required interlocks, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS/IEC:60947-2 as amended upto date complete with following accessories for each ACB. Independent electrical and mechanical spring closing mechanism . 3 Nos. Phase indication LED Lamps with 2 Amp. Back up MCBs. Including breaker ON, OFF indications. "Bus-Bars : 4- Pole aluminium bus bars of minimum of 3200 Amps. Capacity with heat shrinkable coloured sleeves and i/c. DMC / SMC bus bars supports at required intervals complete for cross section, size supports and their spacing etc. for with standing fault level of 31 MVA for 1-Sec. Interlocking : Electrical through advance contacts in ACB's (incomer & bus couplers) and mechanical (Inbuilt in ACBs) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possible of accidentally approaching two supplies at one bus section." Outgoings : Each outgoing shall comprise of the following :- ACBs/MCCBs,shall be of Four pole horizontal drawout type of fault breaking capacity KA (Ics=100%Icu=Icw(1sec.)) , with inbuilt over current, short circuit, earth fault microprocessor release.in each outgoings., 800Amp ACB 4P MDO 50KA : 1 No 630 Amp. 4 Pole, MCCB 50KA: 1 No having variable current settings (Ics=100%Icu, 50 kA) with over current, short circuit, earth fault protection, spreader links and extendable ON/OFF rotary handle - CT's of ratio 630/5 Amps. Class -I, 15VA -1 Set (1 Set of 3 Nos.) 160 Amp., 4 Pole, MCCB 50KA: - 1 No. having variable current settings (Ics=100%Icu, 50 kA) with over current, short circuit, earth fault protection, spreader links and extendable ON/OFF rotary handle 250 Amp., 4 Pole, MCCB - 4 Nos. having variable current settings (Ics=100% Icu, 50 kA), with over current, short circuit, earth fault protection, spreader links and extendable ON/OFF rotary handle. 125 Amp., 4 Pole, MCCB - 2 Nos. having variable current settings (Ics=100% Icu, 50 kA), spreader links with over current, short circuit, earth fault protection, spreader links and extendable ON/OFF rotary handle . 63 A,4P, MCCB, 25 KA 2 No's.
"APFC PANELS AUTO Power Factor Correction Capacitor panel. (INDOOR TYPE) Supply, Transportation,Receiving, Unloading, Shifting, installation, testing and commissioning of factory built floor mounted auto / manual power factor correction panel of following capacity having 3 phase MPP heavy duty type power capacitors 480Volts in the required number of steps as given below provided with discharge resistors and detuned filters (with 7% block reactor) for suppression of harmonics. The system shall have microprocessor based power factor controller provided in the command module having target PF setting and digital PF display. The panel shall be of suitable size fabricated from cold rolled sheet steel of 2 mm thick for enclosure with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, provided with cooling fans (with thermostat) and grills for proper ventilation complete with gaskekts and interconnections including connections with CTs in the main LT panel as per specifications complete as required. " (The board shall be dust & vermin proof with degree of protection of IP 42). The APFC PANEL SHALL BE 500 +50 KVAR CAPACITY IN 10 STEPS (100+100+50+50+50+50+25+25+25+25)+50 (Direct for Transformer Load) Incomer :- 1000Amp, 415v, 4P, ACB, (MDO Type)with Multifunction meter. 1 No . Outgoing 100 KVAR Cap. Bank 02 Sets each Containing 1 No. 250A, TP MCCB, 1 No. 250Amp Contractors, Capictor MPP type Hevy duty Capastors of 100 KVAR. 50 KVAR, Cap. Bank 04 Sets each Containing 1 No. 125Amp TP MCCB, 1No. 125Amp, Contactors and Set of 50 KVAR Capacitor 25 KVAR, Cap. Bank 03 Sets each Containing 1 No. 63Amp TP MCCB, 1No. 63Amp, Contactors and Set of 25 KVAR Capacitor 15 KVAR, Cap. Bank 01 Sets each Containing 1 No. 40Amp TP MCCB, 1No. 40Amp, Contactors and Set of 15 KVAR Capacitor 10 KVAR, Cap. Bank 01 Sets each Containing 1 No. 40Amp TP MCCB, 1No. 40Amp, Contactors and Set of 10 KVAR Capacitor 50 KVAR Capacitor Bank for Transformer on No Load Contating 1 No. 125Amp TPMCCB one Set of 50KVAR Capacitor Power Factor Correction Relay:- (12 Stage) 1 No. 12 stage power correction relay shall be provided in each panel.
Sandwich Bus Trunking Supplying,Receiving,Unloading,Shifting ,installation,testing and commissioning of following Rating of. Pre-fabricated sandwitched Aluminium bus trunking suitable for 415V, 3-Phase, 4-Wire, 50 Hz, AC supply system,bus trunking shall be designed to withstand short curcuit current for one second, IP-54 enclosure complete with bends, expansion Joints, fire barriers, Copper flexible end connections at both ends, earthing with 2 runs of Aluminium earth of size 50 mm x 5 mm strips etc. i/c. necessary supports etc. as per specification,suitable for INDOOR Installations with . (IS:8623/IEC:60439) ammended upto date as required. Bus Trunking suitable for 2000Amp for 2 Nos.1 MVA Trafo to LT Panel in substation Block.
HT Cables (SUPPLY) Supply of cables: Contractor has to Measure Actual Length/Measurements of Cables Before Supplying. Supply of following size of 11kv(E) , stranded, Aluminium conductor, XLPE insulated, screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid up, inner sheathed (ST-2 PVC), galvanised steel strip armoured, and overall PVC sheathed (ST-2 PVC) black cable conforming to IS: 7098/II/85 with latest amendements. 1 Nos.3Cx185Sqmm XLPE Cable.
1 Nos.3Cx150Sqmm XLPE Cable.
1 Nos.3Cx95Sqmm XLPE Cable.
LT Cables (SUPPLY) Supply of cables: Contractor has to Measure Actual Length/Measurements of Cables Before Supplying. Supply of following size of 1.1kv , stranded, Aluminium conductor, XLPE insulated, galvanised steel strip armoured, and overall PVC sheathed (ST-2 PVC) black cable conforming to IS: 7098/II/85 with latest amendements. 1 Nos.3.5Cx300 Sqmm .
1 Nos.3.5Cx70 Sqmm .
laying of 11Kv Cables Laying of One no. XLPE power cable of 11 KV of following sizes direct in ground i/c. excavation, sand cushioning, protective covering and refilling the trench etc. as per specifications. Above 120 sqmm and Up to 400 Sqmm .
"Laying of one number XLPE power cable of 11KV grade of following size in the existing Cable trays /RCC/HUME/STONEWARE/METAL pipe/ Closed duct as per specifications." Above 120 sqmm and Up to 400 Sqmm .
"11KV Cables End Termination Supplying and Making 11 KV, indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs sutable for 3 core XLPE Aluminium conductor cable of 11 KV grade as required." 1 Nos.3Cx185Sqmm XLPE Cable.
1 Nos.3Cx150Sqmm XLPE Cable.
"laying of LT Cables Laying of One no. PVC Insulated and PVC Sheathed XLPE power cable of 1.1 KV of following sizes. direct in ground i/c. excavation, sand cushioning, protective covering and refilling the trench etc. as per specifications." Above 35 sqmm and Up to 95 Sqmm .
Above 185 sqmm and Up to 400 Sqmm .
Laying of One no. PVC Insulated and PVC Sheathed XLPE power cable of 1.1 KV of following sizes. in the existing Cable trays /RCC/HUME/STONEWARE/METAL pipe/ Masonary Open duct as per specifications. Above 35 sqmm and Up to 95 Sqmm .
Above 185 sqmm and Up to 400 Sqmm .
LT Cables End Termination Supplying and Making End Terminations with Brass Compression Glands and Aluminium Lugs for following size of XLPE Aluminium conductor cable of 1.1 KV grade as required. 1 Nos.3.5Cx300 Sqmm .
1 Nos.3.5Cx70 Sqmm .
450mmx50mmx2mm thick
600mmx50mmx2mm thick
500KVA DG SET "- Supply, Transportation,Receiving, Unloading, Installation, Testing & Commissioning of 500 KVA DG Set in acoustic enclosure and complete with all accessories, with outdoor type DG panel,The work of including complete DG set exhaust stack (chimney)/on the walls of nearest Building up to the required height with supporting steel structure,Exhaust Pipes, Insulation of Exhaust Pipe, Piping from Storage oil Tank etc complete as required for regular operations of DG Set shall be supplied, Errected by the contractor under this scope of work ,Standard set of tools, With spares required as per OEM for 02 year of normal operation of the DG sets. (Height of stack chimney as per local PCB). As per SLD & specifications Also included in this item. Approval from the Pollution control Board & Other concerned authorities shall be obtained by the contractor.
EARTHING SYSTEM (CHEMICAL EARTHING). Supply, installation and connecting a Copper CHEMICAL EARTHING SAFE EARTH ELECTRODE 76MM DIA,2 MM thick 3 Mtrs long earthing electrode with non corrosive hygroscopic Backfill compound The cost of digging and back filling earth electrode as per IS 3043-1987.at a depth of 2000 mm. A masonary strucutre shall be constructed to a depth of 750mm. and a heavy duty CI Cover shall be used to cover the pit. Earth resistance with in 1 ohm. as per requirements of local authorities, With15 years warranty including Masonary chamber with locking arrangements. The Depth of the Rod to be Increased to achieve the Required Earth Resistance of 1-2 ohms. Neutral Earthing for 2 No Transformers& 3 Nos DG Sets
Supply, installation and connecting a GI CHEMICAL EARTHING SAFE EARTH ELECTRODE 76MM DIA,2 MM thick, 3 Mtrs long earthing electrode with non corrosive hygroscopic Backfill compound The cost of digging and back filling earth electrode as per IS 3043-1987.at a depth of 2000 mm. A masonary strucutre shall be constructed to a depth of 750mm. and a heavy duty CI Cover shall be used to cover the pit. Earth resistance with in 1 ohm. as per requirements of local authorities, With 15 years warranty including masonary chamber, The Depth of the Rod to be increased to achieve Required Earth Resistance of 1-2 ohms. Body Earthing
Earthing : (Optional) with CU/GI Plate. Providing and fixing 25 mm x 6 mm copper strip in 40 mm dia GI pipe from earth electrode to transformer neutral/conductor as required.
Providing and fixing 25 mm x 6 mm copper strip on surface or in recess for earth connection with copper clamps etc. as required
Providing and fixing 25 mm x 6 mm G.I. strip in 40 mm dia GI pipe from earth electrode to equipment/ panels as required.
Providing and fixing 25 mm x 6 mm G.I. strip on surface or in recess for earth connection with clamps etc. as required
Providing and fixing 6.00 SWG G.I. Wire on surface or in recess for earth connection with clamps etc. as required
Safety Equipments : Supplying and fixing of nominal Epoxy coated insulated mat of conforming to IS:15652:2006 and meeting the requirements of IS 5216, IS 8437, IEC-479 Pub-1, alongwith suitable adhesive /chemibound, pu-resin, water proofing compound and sealing material as per in service recommendations of Annexure-'A' 'Clause C' of IS:15652 and Suitable for Class - A upto 3.3 KV AC & 240 V DC without HT Trolley movement.
Supplying and fixing of nominal Epoxy coated insulated mat of conforming to IS:15652:2006 and meeting the requirements of IS 5216, IS 8437, IEC-479 Pub-1, alongwith suitable adhesive / chemibound, pu-resin, water proofing compound and sealing material as per in service recommendations of Annexure-'A' 'Clause C' of IS:15652 and suitable for Class - B upto 33 KV without HT Trolley movement.
Providing and fixing fire extinguishers with all other accessories etc. as required (capacity 4.5 kg.)
Providing and fixing G.I. Buckets of 9 ltr. Capacity (04 Nos. Buckets in each set) painted with red oxide and red paint and written with white paint "Fire" and mounted on MS angle iron bracket of size 50mm x 50 mm x 6 mm thick and 500 mm. long i/c. providing and fixing on floor etc. as required i/c. filling with dry sand.
Supply of First Aid Box with medicines, accessories as approved by St.John Ambulance Brigade/Indian Red Cross conforming to IS:2217-1963
Supply and fixing of Shock treatment chart of standared size at least two language( Hindi & English) with aluminium frame and transparent polycarbonate cover sheet as required.
Supply of Rubber gloves of 11 KV grade as per IS: 4770-1968, IEC 60903:2002
Providing and fixing Medium voltage danger notice plate 200 mm x 150 mm made of M.S. sheet atleast 2 mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Providing and fixing High voltage(11KV) danger notice plate 250 mm x 200 mm made of MS sheet atleast 2 mm thick and vitreous enameled white on both sides and with inscription in single red colour on front side as required.
HT EARTHING Road
FIRE PUMPS, EQUIPMENT, PIPING, VALVES & ACCESSORIES : Electric Motor Driven Pump (Location - Plant Room ) Supplying, installing, testing and commissioning of Fire authority approved Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal mounted End Suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 65M while running at 2900 RPM complete with mechanical seal pressure gauge with GM cock on the delivery side of pump and including 50 mm by pass arrangement (with 50 mm valve and up to 5 meter GI class 'B' pipe) for periodical testing of working of pumping test. Squirrel cage, induction motor TEFC type suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed of 2900 RPM with flexible coupling and coupling guard . Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (4 Nos., heavy duty). Coupling and coupling guard for direct coupling of pump and motor. Drain Pipe with Valve (50 mm dia) Main Fire Pump/Sprinkler Pump Discharge : 2850 LPM App. Head : 65 M
Diesel Engine Driven Fire Pump [Stand by pump] (Location - Plant Room :) Supplying, installing, testing & commissioning of fire authority approved Diesel Engine driven fire pump suitable for automatic/manual operations consisting of the following: Horizontal mounted End Suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 60 M while running at 1800 RPM complete with mechanical seal pressure gauge with GM cock on the delivery side of pump including 50 mm bypass arrangement (with 50 mm valve and upto 5 meter GI class 'B' pipe) for periodical testing of working of pumping set pumps. Radiator cooled diesel engine of suitable BHP at 1800 RPM for the above pump complete with standard accessories & suitable cooling system as described in specifications. Common base plate for mounting pump & engine of requisite strength manufactured out of M.S. channels as per manufacture's recommendation with heavy duty Anti Vibration pads. (Cushy foot) (6 nos., heavy duty) Coupling & coupling guard for direct coupling of engine & pump. 200 liters capacity day oil storage tank fabricated from 16 SWG thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, vent, drain connections, filling connection & level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. 24 volts 180 AH lead acid battery (12 volts - 2 Nos) with boost/Trickle charger for starting the engine automatically complete as required. Provision for starting of Engine automatically in case of power failure at the time of fire Diesel Engine driven pump of: Discharge: 2850 LPM App. Head: 65 M
"Electrical Motor Driven Jockey Pump Location - Plant Room :" Supplying, installing, testing & commissioning of fire authority approved electrically driven Jockey pump suitable for automatic/manual operation consisting of the following: Horizontal mounted end suction jockey pump having cast iron body, volute bronze impeller, stainless shaft capable of delivering 180 LPM against total head of 65M while running at 2900 RPM complete with mechanical seal pressure gauge with mechanical seal GM cock on the delivery side of pump including bypass arrangement (with 25 mm GM stop valve and up to 5 meter G.I. class 'B' pipe) for testing of working of the pumping set as required. Squirrel cage induction motor suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with synchronous speed of 2900 RPM T.E.F.C type connected to pump with flexible coupling and coupling guard . Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty 4 Nos. Anti Vibration pads.(Cushy foot) Drain pipe with valve (25 mm dia) Jockey Pump :- Discharge : 180 LPM (3 LPS) App Head : 55 M
Supply, installation, testing and commissioning of Pressure switch of approved make for Hydrant pump, jockey pump and Diesel Engine Driven pump including necessary wiring and cut off valve up to central panel & other material as described in specifications.
Supply, installation, testing and commissioning of Fire authority approved suitable pressure vessel with air release valve (minimum 450 mm dia & 1500 mm height) with all fittings including two nos. pressure gauge on the delivery side, 80 mm dia flanged inlet and 50 mm dia drain line with 50 mm dia G.M. gate valve.
Providing, fixing, testing and commissioning of heavy class MS pipe, IS : 1239 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required including fixing the pipe with necessary structural supports including painting of two coats of synthetic enamel paint over two coats of red oxide primer including all civil breakages and making good the same (Location: Plant room). 150 mm dia (Nominal Bore)
Providing, fixing, testing & commissioning of heavy class MS pipe, IS : 3589 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required including fixing the pipe with necessary structural supports (for delivery/suction manifold relating to the pumps) including painting of two coats of synthetic enamel paint over two coats of red oxide primer including all civil breakages and making good the same [ Location : Plant room]. 200 mm dia (6.35 mm thick) with necessary supports etc. as required. (Nominal Bore)
Providing, fixing, testing & commissioning of following dia C.I. Double flanged 'Y' typed Strainer including nut, bolts and 3 mm thick gasket as required. 200 mm dia
150 mm dia
100 mm dia
Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with flanges, nuts, bolts and washers complete for following sizes :- [PN 1.6 rating]. 200 mm dia (Gear operated)
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
Providing, fixing, testing & commissioning of dual plate non-return valve complete with nuts, bolts and washers. 200 mm dia
150 mm dia
80 mm dia
65 mm dia
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2.
Providing and fixing exhaust, Diesel engine driven pump exhaust M. S. pipe class 'C' 150 mm dia including fitting like flanges, bends, reducers, etc. 50 mm thick fibre wool insulation aluminium cladding, 24 gauge, necessary excavation, fixing of silencer connections at engine exhaust, necessary supports, back filling, cutting and making good, bird proof and weather proof flap complete in all respect as directed.
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling welding including cost of fasteners clamps in R.C.C. structural members as directed, including two or more coats of synthetic enamel paints over one coat of primer after surface preparation including cutting and making good walls.
Excavation of required width for fire fighting pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 100m for all kinds of soil. Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Supply, Installation testing & commissioning of Black Mild Steel Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site including cutting & making good the walls, floors, RCC work etc cutting chases & filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) (For Internal work). Note: Pipes upto and 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 25 mm dia (Nominal Bore)
32 mm dia (Nominal Bore)
50 mm dia (Nominal Bore)
65 mm dia (Nominal Bore)
80 mm dia (Nominal Bore)
100 mm dia (Nominal Bore)
150 mm dia (Nominal Bore)
Supply and painting for M.S. Pipe with a coat of red oxide Primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparation and cleaning of pipe from all external material. 25 mm dia (Nominal Bore)
32 mm dia (Nominal Bore)
50 mm dia (Nominal Bore)
65 mm dia (Nominal Bore)
80 mm dia (Nominal Bore)
100 mm dia (Nominal Bore)
150 mm dia (Nominal Bore)
Providing and applying two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 including conducting required Test. 80 mm dia
100 mm dia
150 mm dia
Providing & Fixing of gun metal double headed hydrant valves with 100 mm dia flanged inlet & 63 mm dia female outlet complete with rubber blank cap and chain as per IS : 5290 (For internal hydrant). [ ISI marked should be embosed]
Providing & Fixing of gun metal single headed ISI marked oblique pattern hydrant landing valves with 80mm dia flanged inlet & 63 mm dia female outlet complete with gun metal cap and GI chain twist release type plugh and all accessories as per IS : 5290-1983 Type A
Providing & Fixing of 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with Gunmetal male & female instantaneous type coupling (IS 903)
Providing & Fixing of standard gun metal 63 mm dia branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.
Providing & Fixing of standard Fireman's Axe with heavy insulated handle conforming to (IS:926).
Providing & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required.
Providing & Fixing of 100 mm dia gun metal fire brigade suction hose coupling of (gunmetal draw off connection) with 100 mm dia M.S. 'C’ Class suction pipe with 100 mm dia C.I. foot valve. (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected to static water tank.
PORTABLE FIRE EXTINGUISHERS : Providing & fixing of ISI marked (IS:940) portable chemical Fire Extinguisher, water (gas pressure) type capacity 9 ltrs with gun-metal cap. and nozzle and complete in all respects including initial fill and wall suspension bracket.
Providing & fixing of ISI marked (IS:2878) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667 and wall suspension bracket. Capacity 4.5 kg
Providing & fixing of ISI marked (IS: 13386-1992) mechanical foam type fire extinguishers 50 kg consisting of welded M.S. trolley mounted cylindrical body, squeeze lever discharge valve fitted with pressure discharge hose, discharge nozzle, trolley etc., finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.
Providing and fixing of carbon-di-oxide fire extinguishers (22.5 kg) trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
"SUB HEAD-B (FIRE HYDRANT ACCESSORIES) Providing and fixing SS304 Single headed landing valve conforming to IS -5290 (Type-A) with 63 mm dia. single instantaneous female coupling on the outlet SS304 metal blank cap and chain, necessary companion flanges, nuts, bolts, washer and gasket complete as per specification. (ISI marked). All parts and body shall be of SS304 as per IS:5290." Single outlet
Providing and fixing first aid fire hose reel drum wall mounting, swinging type(Powder coated finish in fire red) fitted with 20 mm dia. 30 m long high pressure hose(IS:444, Type-2) with 5 mm outlet SS nozzle with shut off valve (IS:8090). Name of Manufacturer should be embossed on the drum and complete hose reel drum shall be conforming to IS:884)
Providing and fixing 63 mm dia. 15m long rubberized lined hose including SS304 male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to IS 636 Type-A and coupling to IS 903 -1975 ( ISI marked)
Providing and fixing standard short size SS304 branch pipe with gunmetal nozzle 16 mm dia. outlet with standard instantaneous type 63 mm dia. coupling. (ISI marked, IS:903)
Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 2100x 900 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)
Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. Sheet with single or double glazed front door and locking arrangement, painted "Fire Red" with powder coated paint "Fire Hose" written on front including suitable supports to place 900 mm above ground level, approximately size 750x600x250 mm deep (to house two lengths of canvas hose with couplings, branch pipe and nozzle for external hydrants)
Providing and fixing gunmetal fire brigade inlet head as per IS:904 Specification tested for 20 Kg/cm2 with 63 mm dia. instantaneous type inlet and 100/150mm dia.. flanged outlet with built-in check valve for fire brigade connection to under ground tanks and fire risers including companion flanges as portable " E" including nuts, bolts & washers etc. Three way
Providing and fixing gunmetal fire brigade suction 150 mm dia. for fire tank complete with PVC Cap companion flange as per table "E" nuts, bolts, gasket etc 150 mm
Supplying and fixing of Fire Man's Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.
Air Cushion Tank for Risers Providing and fixing of air vessel of the following specifications fabricated with MS Pipe of thickness specified. specifications a. Diameter : 200 mm b. Shell Thickness: 6.35 mm c. Dish Ends : 10 mm d. Height : 1000 mm e. Finishing: Two coats of red enamal paint over primer out side and two coats of epoxy coating inside. f. Material of construction: M.S g. Test Pressure: 20 Kg/Sq.Cm. i. Height of supporting legs: 400 mm j. Quantity Note: Contractor should submit general arrangement drawings before fabrication of vessel and ultrosonic test report to be submitted on supply of vessel and test to be conducted at the presence of Plumbing-In-Charge. Also cost shall include two nos. Gunmetal NRV(ISI Marked)
SUB HEAD-C (SPRINKLERS ACCESSORIES) Providing and fixing 15 mm gunmetal sprinkler head with quartz bulb and set to operate at specified temperature pendent/ upright/ side wall /quick response as per instruction fixed with loctite. Temperature of operation 68 deg.C K-80 Normal response Pendent type/ upright type
Normal response Pendent type
Normal response Side wall type
Extended throw normal response Side wall type.
Providing & fixing 25mm dia. UL listed gunmetal inspector test and drain valve with integral sight glass connected to drain line complete in all respects.
Providing and fixing electrically operated flow indicating switches model System Sensor in sprinkler branch line on each floor with necessary junction box installed in accessible place (Wiring from switches to panel and stair case pressurization not included) Providing and fixing electrically operated flow indicating switches model System Sensor in sprinkler branch line on each floor with necessary junction box installed in accessible place (Wiring from switches to panel and stair case pressurization not included) 100/65/50 mm dia.
Providing and fixing gunmetal installation valve with turbine type automatic alarm to be connected with control valve , drain valve, test valve and piping as per manufacturer's specifications complete in all respects. 150 mm dia.
Providing and fixing UL/Fm listed powder coated finish Escutcheon plate complete including fixing in position on pipe and ceiling complete in all respects. (Size=15NB)
Providing and fixing UL/Fm listed SS braided flexible pipe with accessories complete with all accessories specified in technical specifications(Size=15B) a. 780mm long
b. 1000mm long
PLUMBING Providing and laying non-pressure NP8 class p.vc . pipes with collers jointed with soln including testing of joints etc. complete : ASTRAL (PVC pipe foamcore NP8)OR EQUIVALENT 150 mm dia.pvc pipe
200 mm dia. PVCpipe
300 mm dia. PVC . pipe
"SANITARY WORK Providing, fixing, jointing, testing and commissioning of UPVC pipe with fittings (for waste pipe from individual fixtures to floor trap / floor drain & vent pipe& rain water) IS : 4985 (Pipe Class III - 6 kg / sq.cm) cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces . Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated. Cost shall be inclusive of providing and laying 1:2:4 cement concrete all around the pipe including pillers, supports, shuttering & centering. " 110 mm dia
75 mm dia
Providing and fixing MS holder-batclamps of approved design to Upvc pipe embedded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the wads etc. 110 mm dia
90 mm dia
Providing and fixing uPVC bend of required degree with access door, insertion rubber wasrier 3mm thick, bolts and nuts complete. 110 mm dia
90 mm dia
Providing and fixing uPVC plain bend of required degree 100 mm dia
75 mm dia
Providing and fixing uPVC double equal junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100 x 100x100x100 mm
75 x 75 x 75 x 75mm
Providing and fixing uPVC double equal plain junction of required degree 100 x 100x100x100 mm
75 x 75 x 75 x 75mm
Providing and fixing uPVC single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete 100 x 100x100x100 mm
75 x 75 x 75 X 75mm
Providing and fixing uPVC single equal plain junction of required degree 100x100x100 mm
Providing and fixing uPVC door piece, insertion rubber washer 3mm thick, bolts and nuts complete - 100mm 110 mm dia
90 mm dia
Providing and fixing uPVC trap of self cleansing design with screwed down or hinged grating with or without vent ami complete, including cost of cutting and making good the walls and floors 100mm inlet and 100mm outlet
"Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : "15 mm dia nominal bore
20 mm dia nominal bore
" Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work " 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
"Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work- Exposed on wall" 25mm nominal bore
32mm nominal bore
40mm nominal bore
"Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc." 15mm nominal bore
20mm nominal bore
25mm nominal bore
32mm nominal bore
Providing and fixing brass stop cock of approved quality 15mm nominal bore
20mm nominal bore
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end). 25 mm nominal bore
50mm nominal bore
Providing and fixing unplastcised PVC connection pipe with brass unions: 30 cm length ( 15mm nominal bore)
Providing and fixing C.P . brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15mm nominal bore
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) 50mm dia
"Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type" With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design "Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :" With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
"Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:" Inside dimensions 455 x 610 mm and 45 cm deep for single pipe lineWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber with common burnt clay F.P.S (non modular) bricks of class designation 7.5. For 455 x 610 mm size- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
"Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : " For pipes 100 to 250 mm diameter
For pipes 250 to 300 mm diameter
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F .P .S. (non modular) bricks of class designation 7.5
"Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. " 110mm diameter single socketed pipes
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming IS: 5382 leaving 10mm gap for thermal expansion. Single pushfit Coupler : 110mm Single Pushfit Coupler
"""Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming IS: 5382 leaving 10mm gap for thermal expansion. Single pushfit Coupler : 110mm Single Pushfit Coupler"" Bend 87.5°" 110mm bend Bend 87.5 degree
Shoe (Plain) 110mm Shoe (Plain)
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 25cm diametre and weighing not less than 440 grams.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board, 610x510 mm bowl depth 200 mm
"Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: " White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing uPVC floor drain of following size inlet and outlet including cutting and making good the walls and floors wherever required complete in all respects.
Providing and fixing uPVC cleanout plug with openable cap for uPVC pipes For 110 mm OD pipes
Making khurras 600x600mm with average minimum thickness of 5 cms cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12mm plaster in cement mortar 1:3(1 cement :3 coarse sand) finished with floating coat of neat cement induding rounding of edges and finishing of outlet, complete in all respects.
Providing and fixing in position uPVC PIPE and fittings of heavy class (c) conforming to IS:1239 (for waste pipe from individual fixtures to floor trap / floor drain & vent pipe) Including fixing at wall / ceiling level supported by galvanized clamps and hangers etc. For waste pipes 40mm OD
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less that 105gms.(Make:Jaquar/Varmora/Essel)
Providing and fixing Division plate for the partition of urinals ( Make Hindware/Vermora/Essex )
Providing & fixing electric operated hand dryer with photovoltic control of reputed manufacturer complete as per specification & instructions of engineer.
Providing and fixing toilet paper holder . (Make: Jaquar/Varmora/Essex) C.P. brass
Providing and fixing towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.(Make:Jaquar/Varmora/Essex)
Providing and fixing water closet squatting pan (indian type W.C. pan) with 100mm sand cast iron P or Strap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fitting and fixture complete including cutting and making good the walls and floors wherever required : White vitreous china orissa pattern W.C. pan of size 580X440mm with intergal type foot rests
Providing and fixing white vertreous china pedastal type water closet (european type) with seal and lid, 10 litre low level white vitreous china flusing cistern & C.P flush bend with fitting & C.I. brackets, 40mm flush bend, overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid seat and lid .
Provinding and fixing white vetreous china flat back or wall corner type lipped front urinal basin of 430 X 260 X 350mm and 340 X 410 X 265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin wit 5 litre white P.V.C automatic flushing cistern
Providing and fixing P.V.low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixture complete 10 litre (full flush) capacity-white
Providing and fixing white vitreous china wash basin including making all connection but excluding the cost of fitting Flat back wash basin of size 630 X 450mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fitting complete 40mm dia (flexible pipe)
Providing and fixing 600 X 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats wiyh C.P. brass screws and washers complete.
Providing and fixing toilet paper holder : C.P. brass
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipe but without fittings and base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810gms. 15 mm dia, nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standard and weighing not less than 690gms. 15mm dia, nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931. 15mm dia, nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm dia, nominal bore
Providing laying and jointing glazed stoneware pipes grade 'A' with stif mixture of cement mortar in the of 1:1 (1 cement : 1 fine sand) including testing of joints etc complete. 100mm diameter
150mm diameter
Providing & fixing necessary plumbing for guard room
Providing, fixing and testing of skid mounted pumping system comprising of :- Horizontal centrifugal pumping set with CI body and bronze impeller with stainless steel SS 304 shafts connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply. GI Suction and delivery header with Ball valves Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. Complete set system to be mounted on a common base frame and shall follow following duty. Fresh Water Transfer Pump No. of Pumps: 3 (2 Working + 1 Stand by ) (1set) Capacity : app.1200 lpm Head : 50m
Process Water Transfer Pump No. of Pumps: 3 (2 Working + 1 Stand by ) (1set) Capacity : app.550 lpm Head : 50m
Providing and fixing motor pump controller cum water level indicating panel in powder coated sheet metal box in 16 gauges M.S including the following: Electronic water level controller working on magnetic type sensing probes with necessary length of armored cable up to control panel. Electronic minimum 4-level indicator with magnetic type sensing probes and necessary length of armored cable upto control panel. Arrangement of alternate switching mechanism for operational and standby pumps. For Water level indicators with following details: Underground water tanksMinimum 4 level Multi level indicators with magnetic type sensor probes complete.
For water level controllers with electronic sensing probe complete in all respect for following functions. i) Tubewell Water Pumps To cut on at low level in raw water U.G tanks and cut off at high level in U.G raw water tank and with cyclic relay to make the working tubewell as standby and standby tubewell as working every time tubewell start.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete (The cost of flanges will be paid separately). 80mm dia
150mm dia
200mm dia
Providing and fixing C.I double flanges suction strainer bucket type/ “Y” type including, nuts, bolts and 3mm thick rubber insertion complete. 200mm dia
Providing and fixing butterfly valves, wafer end type class PN 1.0 as per I.S:13095 - 1991 or BS:5155, including necessary nuts, bolts, gaskets etc. complete 150mm dia nominal bore with lever.
200mm dia nominal bore (gear operated).
Providing and fixing M.S. slotted cable tray supported from ceiling at intervals of 60cms on both ends including cable clips with nuts and bolts welding of support rods with ceiling inserts or through dash fasteners cutting and making good complete. 300mm wide
150mm wide
Providing and fixing M.S. structural work fabricated from standard section e.g. M.S rounds, angles, channels, plates including cutting to size, drilling, welding fixing and welding to insert plates in RCC structural members or through dash fasteners as per site conditions as directed by Engineer-in-charge including cutting and making good the walls, ceilings and floors (for pipe supports, clamps etc.)
Submersible pumps Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect. (one working+One Standby )(1set) (Solid handiling capacity 12mm) Capacity : 225 lpm (Each) Head : 12 m HP (Approx) - 1.0 HP
Supplying & fixing of Main gate
Providing, fixing & commissioning IT,telecom & security network
Providing, fixing, testing & commissioning common ETP plant with tanks (0.5KLD)
Supplying & Fixing of weigh Bridge 80 MT capacity with all accessories including civil works for operator room.
EMP & SMP during ConstructionExcavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto a lead of 20 metres and lift upto a 1.5 metres
Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give fair finish including centering, shuttering,strutting and propping etc, with wooden batten and ballies, height of proppring and centering below supporting floor to celing not exceeding 4mtrs. and removal of the same from insitu-reinforced concrete and plain cement conceret works in:
Providing and laying cement concrete 1: 2: 4 (1Cement : 2 Sand : 4 graded crushed stone aggregate 20 mm nominal size) excluding cost of centering and shuttering in:
Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 cement:2 sand:4 graded stone aggregates 20 mm thick nominal size) and curing complete. (15.57+15.57+8.9+5.84)=45.88
Brick work using common burnt clay building bricks in foundation and plinth in Cement Mortar 1:6 (1 Cement : 6 Sand) Second Class Bricks
Brick work - Super-structure ,Super-structure above plinth level upto floor two level (Second Class Bricks).
Providing woodwork in frames of doors, windows, clestroy, windowa and other frames wrought, framed and fixed in position complete.
Providing and fixing flush door shutters decorative type core of block board construction with frames of first class hard wood and well matches first class indian teak plyveneering with vertical grains or cross bends and faces of shutter.40mm thick including black enamelled MS butt hinges
Providing 40x3 mm flat iron hold fast etc.
Providing and fixing Aluminium Sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium Tower Bolts,ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:150 x 10 mm =36 no's
100 x 10 mm =84 no's
Providing and fixing Aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm (16+16+2+2)=36
GI sheeting:- Providing corrugated G.I sheet roofing fixed with galvanised iron J.or L. hooks bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white lead complete excluding the cost of purlins refters and trusses. 0.63mm thick sheet
Steel work welded in built up sections,trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. In beams joists channels, angles, tee, flats with connection plates or angle cleats as in main and cross beems, hip and jack rafters, purlins connected to common rafters and the like
Galvanized structural steel plate 200mm wide 6 mm thick 24m long
Lettering with paints of approved brand and manufacture with readymixed paint (other than white) letters/figures of 15 cm height 160 letters
Painting two coats (excluding priming cost on new steel and other metal surfaces eith enamel paint brushin to give an even shade including cleaning the surface of all dirt, dust and other foregin matters: Enamel white paint
15 mm thick cement plaster in single coat on fair said of brick/concrete /stone walls for interior plastering upto floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in grith and finished even and smooth. Cement Mortar 1:4 (1Cement : 4Mortar)
Demolition of below GL upto floor two level including stacking of serviceable materials and disposal of unservicable materials a with in 20 mtrs lead.
Demolition of above GL upto floor two level including stacking of serviceable materials and disposal of unservicable materials a with in 20 mtrs lead.
Providing and fixing of hand appliances (fire extinguisher) as per IS 9337 and IS 13386
Providing and fixing sand buckets Total 2 stands, each stand contains 5 buckets
Providing and fixing of safety siren alarm at admin/control room
Prefabricated Mobile toilet (on rental basis /monthly), Multi-unit prefabricated toilet, 10 seater capacity
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid