| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹18.5 L+₹65,924 (3.69%)Rejected-Finance | L2 | Rejected-Finance not lowest | |
| 3 | L3₹19.5 L+₹1.6 L (9.00%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L3 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹39,800
Closing Date
15 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
PROVN OF STANDBY POWER SUPPLY FOR BOTH MAIN GATES, PERIMETER AND SECURITY LIGHTS AT VSN NAGPUR
2022_MES_536666_1
GE/NAG/22-23/8536/19
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹39,800
7 Oct 2022
8 Jul 2022
22 Aug 2022
8 Jul 2022
15 Aug 2022
1 Aug 2022
Amount
Supply, installation, testing and commissioning of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms of 25KVA assembled sound proof DG set Make- cummins (Model No C25D52) or equivalent in Greaves cotton/ KOEL/ Control switch gear Rating 25 KVA prime power radiator cooled acoustic D.G Set Technical Data Generator Generator set specification Rating - kVA / kWe 25/20 No. of Phases 3 Phase, Output Voltage (V) 415, Power Factor 0.8 (lagging), Current (3 phase/ 1 phase) (A) 35, Frequency (Hz) and RPM 50 Hz, 1500 RPM ,
Engine Specification MoEF Certified Power (bhp) 32, Required Power for Rated kVA (bhp) 31.6, Cooling Liquid Cooled (EG Compleat 50:50), Aspiration Turbocharged Charge No. of cylinders 3, In-line 3, Fuel High Speed Diesel Performance class of generator set ISO 8528-5 G2 Starting system 12 V DC Electrical Lube oil specification CH4 15W40 High-Low level (litre) 7.3-3.2 Total lubrication system capacity (litre) 8 Total coolant capacity (litre) 11 Make: Cummins/ KOEL/ Greaves cotton/ Ashok Leyland/ Mahindra Alternator Specification Alternator frame S0L2M1 Enclosure IP23 Voltage regulation (Max.) ±1% Class of Insulation H Class Stator Winding Double layer lap Rotor Dynamically Balanced Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 % Maximum Unbalanced Load across phases# less than or equal to 25% Telephonic Harmonic factor < 2% Make: STAMFORD/ KIRLOSKAR/ JYOTI/ ALSTOM Ltd/ Crompton greaves
Notes for item No 01:- (i) The quoted rate for DG set is inclusive of PCC foundation. The foundation for DG set should be made of PCC 1:2:4 type B1 using 20mm graded stone aggregate below the floor level minimum 300mm and 200mm above floor platform and of suitable size as per manufacturers recommendations complete all as specified and directed. (ii) The DG set shall be suitable de-rated to suit the climatic condition of AF station VSN Nagpur so as to give desired output including 10% overload. (iii) The DG set shall have inbuilt for auto main failure function (AMF) (iv) The DHPP (fuel) required for testing of DG sets is deemed to be included in the above quoted rates. (v) Phase 1 test is to be carried out by Eng-in-charge for no load and 100% load for 1 hour each and phase-II test will be carried out in presence of SEI/ EI/ IEM for no load, 25%, 50%, 75%, 100% for 11 hours and 110% for 1 hour over load.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply and fixing onload Change over switch manually operated four pole 63 Amp in sheet steel enclossure L&T Cat No CO10630OSOO or equivalent in Legrand / Havells complete all as specified and directed.
M & L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 20 cm in depth for passing of LT cable complete all as specified and directed .
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for Cement concrete in foundation, filling and mass concrete type B2 1:2:4 (40mm graded aggregate). Not exceeding 15 cm in depth for plinth protection for path including Necessary excavation, form work and dismantling of old surface complete all as specified and directed.
Material and labour for sand cushioning below/above and around cable in trenches/ducts with river sand all as specified and directed.
Supply and installation of LT Electric control panel, cubical type, for out door use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made but of aluminium strips of rating 400 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- (Loc :Sub Station Annex Bldg). Make of MCCB : Legrand, Siemens, Schneider.
Chinmaya Enteprises
M/S JAINENDRA KUMAR JAIN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .