Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.8 LAccepted-AOC 90 MYLAPORE CHENNAI TAMIL NADU 600004 | CHENNAI | TAMIL NADU | 600004 | ₹95.8 L | L1 | Accepted-AOC L1 accepted |
| 2 | L2₹97.9 L+₹2.0 L (2.12%)Rejected-Finance | ₹97.9 L+₹2.0 L (2.12%) | L2 | Rejected-Finance L2 Rejected |
| 3 | L3₹1.0 Cr+₹8.4 L (8.76%)Rejected-Finance | ₹1.0 Cr+₹8.4 L (8.76%) | L3 | Rejected-Finance L3 Rejected |
| 4 | L4₹1.1 Cr+₹15.4 L (16.1%)Rejected-Finance | ₹1.1 Cr+₹15.4 L (16.1%) | L4 | Rejected-Finance L4 Rejected |
| 5 | L5₹1.2 Cr+₹26.2 L (27.3%)Rejected-Finance | ₹1.2 Cr+₹26.2 L (27.3%) | L5 | Rejected-Finance L5 Rejected |
| Sl No | Description | Qty | Unit | Aruna Electricals L5 | GEMINI COOLING SYSTEMS PROJECTS PVT LTD L1 | RADHASCOMPANY L2 | KIRDEEP ENGINEERING ASSOCIATES L4 | YUDEK ENGINEERING PRIVATE LIMITED L6 | AKS ENGINEERING L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Renewal by Supply erection and commission of Modular type outdoor units equipped with highly efficient DC twin Rotary compressor with hall inverter type compressor (s) only special acryl percolated heat exchanger low noise condenser fan auto check function for connection error auto address setting with multiple outdoor units of capacities and quantities as mentioned below. Refrigerant should be R410A (Make:Daikin /O general equivalent) | |||||||||
| 1.01 | 20 HP Outdoor Unit | 3 | nos | 4,77,061 ₹14,31,183 | 3,73,000 ₹11,19,000 Lowest | 4,19,976 ₹12,59,928 | 4,45,000 ₹13,35,000 | 5,35,000 ₹16,05,000 | 4,22,000 ₹12,66,000 |
| 2.00Renewal by supply 4way cassette type units with compact cooling coil, electronic expaC9:D11nsion valve and multispeed fan motor, the blower shall be dynamically balanced and designed for slient operation. With Inbuilt Drain pump with wireless remotes (Make:Daikin /O general equivalent) | |||||||||
| 2.01 | 4.0TR 4way cassette indoor unit | 12 | nos | 70,400 ₹8,44,800 | 54,500 ₹6,54,000 Lowest | 58,000 ₹6,96,000 | 62,500 ₹7,50,000 | 72,500 ₹8,70,000 | 63,300 ₹7,59,600 |
| 3.00Supply and installation of Refrigeration copper Piping insulated with Nitrite Rubber Tubular with 13/19mm thickness. | |||||||||
| 3.01 | 41.3mm | 35 | rmt | 2,825 ₹98,875 | 2,420 ₹84,700 | 1,980 ₹69,300 | 2,450 ₹85,750 | 3,750 ₹1,31,250 | 1,400 ₹49,000 Lowest |
| 3.02 | 36.9mm | 47 | rmt | 2,286 ₹1,07,442 | 2,250 ₹1,05,750 | 1,832 ₹86,104 | 2,150 ₹1,01,050 | 3,100 ₹1,45,700 | 1,100 ₹51,700 Lowest |
| 3.03 | 28.6mm | 50 | rmt | 1,855 ₹92,750 | 2,050 ₹1,02,500 | 1,674 ₹83,700 | 1,950 ₹97,500 | 1,800 ₹90,000 | 1,000 ₹50,000 Lowest |
| 3.04 | 22.2mm | 47 | rmt | 1,424 ₹66,928 | 1,700 ₹79,900 | 1,400 ₹65,800 | 1,650 ₹77,550 | 1,250 ₹58,750 | 900 ₹42,300 Lowest |
| 3.05 | 19.1mm | 67 | rmt | 1,208 ₹80,936 | 1,300 ₹87,100 | 1,050 ₹70,350 | 1,260 ₹84,420 | 1,100 ₹73,700 | 700 ₹46,900 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹65,400
Closing Date
28 Jul 2026, 3:00 pmClosed
Office of the Superintending Engineer PWD Building
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle 2, Chepauk Chennai 5
Renewal of Air Conditioner and Lighting arrangements to the 10th Floor meeting hall to the Ex-MLA Hostel and Renewal by Supply and Fixing of 90 Nos. 2TR Hl wall mounting split type AC units in MLA Hostel at Omandurar Government Estate, Chennai-2.
2026_PWD_684650_1
TNPWD/02-2 BCM/2026-27
Open Tender
Electrical Works
Lump-sum
Omandurar Government Estate
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹65,400
16 Sept 2026
9 Jul 2026
28 Jul 2026
9 Jul 2026
28 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Renewal by Supply erection and commission of Modular type outdoor units equipped with highly efficient DC twin Rotary compressor with hall inverter type compressor (s) only special acryl percolated heat exchanger low noise condenser fan auto check function for connection error auto address setting with multiple outdoor units of capacities and quantities as mentioned below. Refrigerant should be R410A (Make:Daikin /O general equivalent) | |||||
| 1.01 | 20 HP Outdoor Unit | 3 | nos | - | - |
| 2Renewal by supply 4way cassette type units with compact cooling coil, electronic expaC9:D11nsion valve and multispeed fan motor, the blower shall be dynamically balanced and designed for slient operation. With Inbuilt Drain pump with wireless remotes (Make:Daikin /O general equivalent) | |||||
| 2.01 | 4.0TR 4way cassette indoor unit | 12 | nos | - | - |
| 3Supply and installation of Refrigeration copper Piping insulated with Nitrite Rubber Tubular with 13/19mm thickness. | |||||
| 3.01 | 41.3mm | 35 | rmt | - | - |
| 3.02 | 36.9mm | 47 | rmt | - | - |
| 3.03 | 28.6mm | 50 | rmt | - | - |
| 3.04 | 22.2mm | 47 | rmt | - | - |
| 3.05 | 19.1mm | 67 | rmt | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_823017.xls
BOQ • 0.24 MB
ConditionAC.pdf
Tender Documents • 0.32 MB
CORRIGENDUM.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .