Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.4 L+₹3.3 L (22.1%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹19.9 L+₹4.8 L (31.9%)Rejected-Finance | L3 | Rejected-Finance Quoted amount more than L1 |
Tender Value
₹13.1 L
EMD Value
₹26,500
Closing Date
9 Dec 2019, 4:00 pmClosed
Maj Vipin V Kumar
Garrison Engineer 07th Club Road Ranchi 834001
PROVN OF SEWAGE SYSTEM ALONGWITH MANHOLE AND SOAKAGE WELL BETWEEN MEDI AND MED-II WARD, BOUNDARY WALL AROUND UTILITY CENTRE IN FRONT OF MAIN GATE AT MH NAMKUM AND SPL REPAIR TO FENCING OF UNIT PERIMETER ARE OF STN HEALTH ORG (L) NAMKUM UNDER GE RANCH
2019_MES_293892_1
8200/1262/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹26,500
Yes
21 Jan 2020
31 Oct 2019
10 Dec 2019
1 Nov 2019
9 Dec 2019
11 Nov 2019
Amount
Excavation in trenches in any type soil n.exc 1.5 m wide and n.exc 1.50m in depth for foundation, pier holes etc n exc 10 sqm on plan and getting out complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Construction of septic tanks, excavation in ordinary soil, foundation in PCC 1:2:4, RCC slab covers including RCC precast manhole cover ,vent shaft and sludge chamber, etc complete for 150 users as per TD No CEJZ/TD/812 Sheet No 1/2 to 2/2 of HQ CEJZ Jabalpur complete all as specified and directed by Engineer-in-Charge
Construction of soakage well, excavation in ordinary soil, foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM (1:6), RCC slab covers in M-25/ RR Masonry/Filling with brick bats, complete of size 3.0m dia x 3.0m deep as per TD No CEJZ/TD/58 sheet 1/1 of HQ CEJZ Jabalpur complete all as specified and directed by Engineer-in-Charge
M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or deduct from above item No 7 for each 25 mm girth or part thereof over or under 30 cm .
M&L Brick work using old size kiln burnt sub class "B" bricks straight or curved on plan exc 6 cm mean raidus built in cement mortar 1:4 complete all as specified and directed.
M&L Mild steel TMT Bar 6 to 10 mm dia as in reinfocement cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with & including Mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No 10 above but 5 mm dia and over up to including 10 mm dia in stirrups, stirrups, spacers and binders
M&L Reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 150 mm bore of pipe complete all as specified and directed.
M&L Cement concrete bed to drain pipes includig packing under and haunching against the sides of pipes after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4: 8 type D-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L Salt-gazed stone ware drain (SP-1) pipe 150 mm bore grade "A" laid in trenches and joined in CM (1:1) complete as specified and directed.
M&L PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in drain/surface channels, completed all as specified and directed
M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) in RCC cover slab over brick drain or man holes and similar article set in CM (1:4) complete all as specified and directed.
M&L 15 mm thick plaster in one layer in CM 1:4 on fair faces of brick/concrete with surface finished even and smooth without extra cement, cement mortar mixed with WPC complete. (WPC measured and paid for separately as supply only)
M&L 15 mm thick plaster in one layer in CM 1:4 on fair faces of brick/concrete with surface finished even and smooth without extra cement, complete all as specified and directed.
Supply only liquid integral water proofing compound all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint laid in trenches or floors complete.
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint fixed to wall complete.
S&F PVC(SWR) 110 mm junction single (single T) equal or unequal complete all as specified and directed
S&F PVC(SWR) 110 mm bends any radius.
S&F PVC (SWR) vent cowl 110mm bore
Dismantling fencing wire mash any type
Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface
Demoliton of concrete of any description and any positon not otherwise specifically provided for.colmn/beams etc
Demolition of brick work built in cement mortar including all quoins, pillars, arches etc.complete all as specified and directed.
M & L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L brick work with sub class' B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc as directed (each line wire to be mesured)
S&F MS angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming
S & F only Mild steel in flat, round bars, in available lengths quality con-forming to Fe- 290 (Gde E- 165)
Supply only 3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied with posts properly comlete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 150 mm & dia of neck 11 to 15mm Complete all as specified and directed
M&L for Rendering 15mm thick in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed
M&L for newly plastered surface of wall and applying two coats of cement based paint over a coat of white wash complete all as specified and as directed
M&L for preparation of new steel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directeed by EIC
Preparing of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide printer.
M&L PCC 1:5:10 type E2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and direced
M&L Rendering 15 mm thick on fair faces of brick work/ concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 15 mm thick on other than fair faces of brick work/ concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L Reinforced cement concrete 1:1.5:3 (20 mm graded aggregate) in foundations , including rafts, footings, foundation beams, plinth beams: bases for columns etc, basement slabs under-reamed piles and mass concrete.
M&L Reinforced cement concrete M-25 (20 mm graded aggregate)in columns, pillars, piers, posts and struts.
M&L RCC(1:2:4) type B1 using 20 mm graded stone aggregate as in lintels, beams upto 1.5m clear span, cills, steps etc and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (If any) of foundation and plinth beams etc and similar work, vertical or to batter for fair finished flat concrete surfaces complete all as specified and directed.
Form work to sides of pillars, posts, stuts, piers, columns and stanchions for square, rectangular or polygonal rough finished concrete surface complete all as specified and directed
Form work to sides and soffits of beams, beam haunching, lintels etc and similar articles rough finished concrete surface complete all as specified and directed
S&F framed work as in doors or gates of angle or other section with guesset plates complete doors etc to be prepared to hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing complete all as specified and directed
M&L three coat of white wash on newly prepared surfaces on wall etc complete
Excavating over areas, n exc 1.5m deep and getting out in any type of soil
All as per item No 54 above but exc 1.5 m but n. exc 3 m deep incl getting out
M&L RCC1 : 1 1/2 : 3 using 20mm graded stone agg.(nominal mix) as in slab supported on beams or on RCC wall complete.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as directed
Formwork to edges of concrete flats, concrete railings, floor and roofs slab n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
M& L Brickwork with sub-class `B’ bricks in one brick thick honey-comb walling,built in CM 1:4 complete all as specified and directed.
M&L loose filling with aggregates of broken stone or boulders of gange 40 to 80 mm pits/soakage pits or wells etc complete all as directed
Removing surplus excavated materials (soil) to a distance exceeding 50 metre but n exc 100 mtr & depositing where directed at level not exceeding 1.5 metre above the starting point, including spreading, complete.
M K Enterprises
M/s Dwarika Nath Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .