| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹15.0 L+₹70,613 (4.95%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
Refer Docs
EMD Value
₹29,700
Closing Date
24 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
CWE (AF) Bareilly
REPAIR REPLACEMENT OF HT NETWORK AND OTHER ALLIED WORK AT BKT
2021_MES_424543_1
ADDN ALTN AND IMPROVEMENT TO SHOPPING CENTRE
Open Tender
Civil Works
Item Rate
120 days
Memaura
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I)(AF) Memaura
₹29,700
Yes
31 Mar 2021
25 Feb 2021
26 Mar 2021
25 Feb 2021
24 Mar 2021
12 Mar 2021
26 Feb 2021 - 5 Mar 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and directed.
Filling under floor (except material) including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified.
Removing excavated material (soil) exc 250m but n exc 500m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
M & L for providing plain cement concrete 1:5:10, type E-2, (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded crushed stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded crushed stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded crushed stone aggregate, as in chajjas and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded crushed stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded crushed stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in fair finished surfaces complete all as specified and directed.
M & L for form work to sides of pillars, posts, struts, piers, columns and stanchions in fair finished surface of concrete complete all as specified and directed.
M & L for form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for 15mm thick cement plaster (External) on fair faces of brick work or concrete surface on wall in CM 1:6 finished fair and even without using extra cement complete all as specified and directed.
M&L for 15mm thick plaster in CM 1:4 on brick/concrete surfaces finished surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for 10mm thick cement plaster (internal) on other than fair faces of brick work or concrete surface on wall in CM 1:4 finished fair and even without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in CM 1:4 on ceiling, soffits, chajja projection complete all as specified and directed
M&L for hard core of broken bricks gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface of broken bricks aggregate, complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 ( using 12.5mm graded stone aggregate) as in base of floors complete all as specified and as directed.
S&F for non-skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed in CM 1:6 complete all as specified and as directed.
S&F for galzed ceramic coloured joint free tiles 450 x 350 x 6 to 7 mm / 450x300x 6 to 7mm thick on walls etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-1, (using 20mm graded stone aggregate) as in plinth protection/ path laid in alternate panels 50mm thick finished even and smooth w/o using extra cement complete all as specified and directed.
S & F push pull or manual type steel rolling shutter, without ball bearing but including top cover, anchoring rod, haps and staple and one shop coat of primer, erected in position as indicated, thickness of laths 1.00 mm complete all as specified and directed.
S&F for aluminium windows sliding type powder coated of approved colour with frame made up of three track standard aluminium channel section of size 92x29.5x1.00mm thick and shutters made up of 50x20mmx1.5mm thick section sliding type including 5 mm thick plain glass and 0.46mm dia and 1.18mm aperture stainless steel wire mess, including rubber gasket, aluminium locking handle, aluminium snap beading and jointing cleats for fixing etc, complete all as specified and directed.
S & F for aluminium section for partition walls made out of aluminium section powder coated of approved colour, section of walls of 100mmx44mmx1.5mm thick standard aluminium section (grid framework of aluminium section not exceeding 1.2mx1.2m or as per size of partition wall) incl 8mm thick plain sheet glass, superior quality fixed with necessary jointing cleats, glazing clips, rubber packing, aluminium snap beading, screws, complete all as specified and as directed by Engr-in-charge.
S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S & F for aluminium deco grills, 6mm thick with a grid of 75mm x 80 mm, fixed in the aluminium frames, including stainless steel wire mesh fixed with aluminium beadings complete all as specified and directed.
S & F mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall surfaces over 3mm thick wall care putty on plastered surfaces to make the surface even and smooth complete all as directed.
M & L for applying three coat of white wash on newly plastered surface as in ceiling over 3 mm thick wall care putty to make the surface even and smooth complete all as directed.
M & L for applying three coat of white wash on newly plastered surface as in walls including preparation of surface complete all as directed.
M & L for 10 mm thick plastering in CM 1:3 mixed with WPC over roofs, finsihed fair and even complete all as specified.
Supply only liquid water proofing compound, complete all as specified and directed.
M&L for water proofing treatment by providing 90-100 micron thick polymeric water proofing membrance over levelling coarse on non-approachable roof (where required) complete all as mentioned below as specified. (i) Applying a coat of bituminous primer @ 0.30 ltrs/Sqm. (ii) After primer, the entire roof surface shall be applied with hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg/Sqm. (iii) Over hot bitumen polymeric water proofing membrance consisting of 90 to 100 micron thick central core HMHDPE film and standard weight not less than 3 Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacturere's instruction and strict supervision of manufacturer's technical representative including as required on verticle surface in parapet.
(iv) Laying 40mm thick brick tiles laid over a bedding layer 20 mm thick in CM 1:4. The cement mortar screed shall be mixed with polymer based liquid water proofing additive @ 5% by weight of cement as per manufacturer's specition/instruction and tile joints shall be filled with polymer based cement proof joint filler manufactured by approved specification/instructions and tiles joints shall be filled with 1:3 CM mixed with crude oil as per SSR-2009 (Part-1) complete all as specified and directed.
M&L for Anti-termite by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Anti-termite by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L for Anti-termite by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L for Anti-termite by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, made by block making machine with strong vibratory compaction and laid in required colour and pattern over sand cushion, filling the joint with sand complete all as specified and directed.
M & L for cement concrete 1:3:6 type C-2, using 40 mm graded crushed stone aggregate as in surface channel or drain complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
M & L for Cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails, posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed
S & F for pre-painted Trapezoidal profile galvalume or Zincalume profiled coloured coated steel sheet 0.63mm total thickness (with coting and painting) as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : 1. The colour of sheet for bldg shall be approved by GE. 2. Sheeting shall be fixed of any height. Make : Tata Bluescope/ Jindal or equivalent
S & F for pre-painted plain profile galvalume or Zincalume profiled coloured coated steel sheet 0.63mm total thickness (with coting and painting) as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : 1. The colour of sheet for bldg shall be approved by GE. 2. Sheeting shall be fixed of any height. Make : Tata Bluescope/ Jindal or equivalent
M & L for painting to steel surfaces of any description not other wise described over 10cm width or girth with two coats of synthetic enamel paint over one coat of red oxide primer incl preparation of new surfaces
M & L for preparation of newly plastered surface of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S & F welded steel wire fabric of weight exc 4 kg per sqm fixed/wlded to steel members complete all as specified and directed.
Taking down carefully copper/Aluminium point wiring (light/fan/socket power) complete of any size, type and including removal of battens pipe and making good to the disturbed surface to match with the existing surfaces complete all as directed.
Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed by Engr-in-charge.
Taking down main DB's along with existing board and MCB's including removing the same from site and making the good to the disturbed surface complete complete all is specified and directed.
Material and labour for point wiring concealed type with 1.5 Sqmm FRLS PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade incl. 1.5 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. medium grade PVC rigid conduit not less than 20 mm dia with its accessories, galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3mm thick laminated sheet cover for fixing switches/ socket/regulators etc for the following: - Note:- (i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit and its accessories. (ii) cutting,chasing for concealed wiring to be included in quoted rate.
(a) One light point controlled by one way switch
(b) One Ceiling / exhaust fan point controlled by one one way switch
(c) One 3 pin swicth socket outlet, 5/6 amps, on independent board
(d) One 3 pin switch socket outlet, 5/6 amps, on same board
All as per item No. 62 above but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete outlet on independent board including single core 2.5 Sqmm FRLS insulated unseathed cabledrawn on same conduit as earth wire and common earth and connecting to earth dolly complete all as specified and directed.
All as per item No. 62 above but with 4.0 Sqmm cable for 3 pin 15 Amps socket complete outlet on independent board including single core 4.0 Sqmm FRLS insulated unseathed cabledrawn on same conduit as earth wire and common earth and connecting to earth dolly as specified. Note for BOQ Item No 62,63 & 64 Cost of cutting/ chasing for conduits and making good disturbed surface deemed to be included in unit rate.
S&F switch piano flush type single pole one way , 5 /6 Amps , 230V grade ISI marked complete all as specified and directed.
S&F switch piano flush type single pole one way , 15 /16 Amps , 230V grade ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 5/6 Amps flush type ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 5/6 &15/16 Amps flush type ISI marked complete all as specified and directed.
S&F ceiling rose surface backlite 63 x 25mm size three terminal complete all as specified and directed.
Supplying and fixing lamp holder, insulated polycabonate body with back plate complete all as spd & directed. Make - Anchor / Cona / Havells / SSK.
Supplying and fixing single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB, Cap 16 amp, 'C' series, 10 KA complete all as specified and directed.
Material and labour for submain wiring in repairs, alongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawn into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked with all conduit accessories of following nominal sizes:- Note :- cutting/chasing for concealed in circuit drawn to be incl in unit rate.
2x4 sq mm + 1x4.0 sq mm (earth) in 20 mm dia PVC conduit.
2x6 sq mm + 1x6.0 sq mm (earth) in 25 mm dia PVC conduit.
Supplying and fixing In-Replacement of powder coated, CRCA steel sheet MCB distribution board as per IS : 8623, degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required of following ratings & ways:-
SPN, 240 volts, 4 ways. Make - Legrand/L&T/ Hager/
SPN, 240 volts, 8 ways. Make - Make - Legrand/L&T/ Hager/
Supplying and fixing tripple pole and neutral, powder coated, CRCA steel sheet, Vertical type MCB distribution board manufactured as per IS 8623 suitable for MCCB incomer upto 125 amp, 8 way, 415 volts, degree of protection IP 43 - IK- 09 with metal door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required. Make : Legrand/L&T/ABB.
Supplying and fixing as per load requirement MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 32 amp, 'C' series, 230 volt Make - Make - Legrand/L&T/ Hager/ HPL/ABB.
(b) SPN 05 to 32 amp.'C' series, 230 volt Make : Legrand/L&T/ Hager/ HPL/ABB.
(c) SPN 40 to 63 amp. 'C' series, 230 volt Make : Legrand/L&T/ Hager/ HPL/ABB.
Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
Supplying and fixing MCCB four pole, 63 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete. Make : Legrand/L&T/ Hager/ HPL/ABB.
Supply and fixing single phase meter box made of polycarbonate from 30 to 60 amps capacity and fixing the same with old meter after rewiring at out side the shop during rewiring work complete.
S&F luminative LED 18/20 watt, 6000K, 230 volt, LED batten complete with high brightness LED tube light in opal finish and connection wire twin core of suitable size from nearest source etc. Make:- Wipro / Havells / Philips /CG.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
M&L for taking down the ceiling fan/exhaust fan/wall fan/of any size from various shops/locations and opening the same for servicing by cleaning each part with air blower/vaccume cleaner and cloths filing the cavities with fillers,painting with synthetic enamal paint by spraying including replacement of worn out nuts,bolts screws,washers,split pin rubber pad,oiling greasing,writing SM/MES no of fan and refixing testing complete all as specified and as directed by engineer-in-charge.
S&F Ceiling fan 1200 mm sweep, AC single phase 230/ 240 volts, AC, 50 Hz off white colour,BEE, (ISI mark) complete with down rod of suitable length, mounting clamps, rubber sheet, nuts, bolts, washers including provision of twin twisted flexible copper cable 23/0.0076 from ceiling rose to connecter block of cieling fan complete all as specified and as directed by Engr-in-charge. Make : Havells/Orient/USHA
Ashirwad Contractor and Supplier
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .