Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 CrAccepted-AOC DUMKA | JHARKHAND | 814101 | L1 | Accepted-AOC L1 Letter No. 38(S)WE Date-04.01.2024 | |
| 2 | L2₹24.9 Cr+₹1.4 Cr (6.03%)Rejected-Finance | L2 | Rejected-Finance L2 Letter No. 38(S)WE Date-04.01.2024 |
Tender Value
₹24.0 Cr
EMD Value
₹24.0 L
Closing Date
28 Nov 2023, 12:00 pmClosed
Executive Engineer, RCD, Road Division, Deoghar
Executive Engineer, RCD, Road Division, Deoghar
Construction of ROB (ROB proper and Approach portion) at Santhali Village near Br. 653 between Sankarpur - Jasidih at km 321/19-21 from Howrah (Job No.-CRF-JHR-2022-23/67)
2023_CECOM_77181_1
RCD/DEOGHAR/2138/2023-24 (3rd Call)
Open Tender
Civil Works
Item Rate
900 days
at Santhali Village near Br. 653 between Sankarpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹24.0 L
Chief Engineer(Comm), RCD, Jharkhand, Ranchi
25 Jan 2024
31 Oct 2023
30 Nov 2023
31 Oct 2023
28 Nov 2023
7 Nov 2023
6 Nov 2023
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. | 90 | m | - | - |
| 2 | Pile Load Test on single Vertical Pile in accordance with IS:2911 (Part-IV) Vertical load | 300 | MT | - | - |
| 3 | Pile Load Test on single Vertical Pile in accordance with IS:2911 (Part-IV) Lateral load | 30 | MT | - | - |
| 4 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. | 9,057.59 | cum | - | - |
| 5 | Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. PCC Grade M15 using batching plant & Concrete pump | 391.19 | cum | - | - |
| 6 | Providing and laying of PCC M15 levelling course 100 mm thick below the pile cap. sing batching plant & Concrete pump | 12.74 | cum | - | - |
| 7 | Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. RCC Grade M35 using batching plant & Concrete pump | 1,929.39 | cum | - | - |
| 8 | Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification RCC Grade M30 using batching plant & Concrete pump | 79.87 | cum | - | - |
| 9 | Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. | 238.4 | cum | - | - |
| 10 | Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification. | 1,059.64 | cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_102936.xls
BOQ Document • 0.35 MB
132492852.pdf
Tender Document • 0.12 MB
ADDENDUM.pdf
Tender Document • 8.37 MB
SBDPart1.pdf
Tender Document • 3.82 MB
SBDPart2.pdf
Tender Document • 3.26 MB
132492854.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .