Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
16 Dec 2025, 3:00 pmClosed
Provision of Second Detection by DC Track circuit to make it Dual Detection at Swadinpur Station for reliability improvement.
SDSTE-DCTC-SDLE-25-26~ER
SDSTE-DCTC-SDLE-25-26
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹2.2 L
16 Dec 2025
23 Nov 2025
2 Dec 2025
1-Provision of Second Detection by DC Track circuit to make it Dual
Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents for alteration work. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD). Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways, then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams 1 will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation and supply of laminated one set o f all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75- micron polyester film for station in Auto CAD. 6 (Six) sets photo copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all t h e locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of design a n d completion documents f o r a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). Per Above/
Modification /Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines /TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved S I P a n d circuit diagrams. A l l the material (Interface cards/re1ays/wiring material/ connectors /fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings /circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. (A) Alteration involving modification from 11 up to 20 routes at SDLE Above/
Modification/ upgradation, validation and alteration of data logger as per site engineer. 3 This includes changes of NMDL software etc. Also data logger to be interfaced with PI/ EI equipment keeping at relay room. This work includes validation, wiring, etc. For this work necessary wire from relay to tag block & from tag block to data logger and tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms and to be inspected by consignee. Above/
Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn. No. IRS: S-34 & S-23 with Amdt. upto date or latest. The interlocking code for this unit shall be "ABCDE". Inspection authority:- RDSO Above/
Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No. IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABCDF". Inspection authority:- RDSO Above/
"Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn. No.IRS: S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO" Above/
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No. IRS: 5-34 & S-23with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDEG". Inspection authority:- RDSO Above/
Q-Series Neutral Track Relay (QT2 Type), 9 Ohm,2 F/2B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-938A & RDSO Specn.No.IRS: S-34 & S-23 with Amdt. up to date as applicable or latest. The interlocking code for this unit shall be "DEFJX". Inspection authority:- RDSO Above/
"Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming t o BRS:939A & 966(Appendix F2) and RDSO Spec No. IRS:S 34, S-23 with amdt. upto date as applicable or latest with latest amdt. or latest. The interlocking code for this unit shall be ""FGHKX"". Inspection authority:- RDSO " Above/
Fixing of Q series relay base plate/metal to metal relay mini group and major group 10 base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on ER & the instruction of Rly. Engineer at site. Inspection authority:- Consignee Above/
"Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ 11 SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." (A) Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Above/
"Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ 12 SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." (B) Supply of End plate 2.5mm/0.091 in thick as per site requirement. Above/
"Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ 13 SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." (C) Supply of End Stopper 10mm/0.0394 in width as per site requirement. Above/
"Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international 14 standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." (D) Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. Above/
"Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ 15 SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." (E) Supply of Markers strip. Above/
Underground, Armoured, Unscreened Railway signaling cable (Heavy Duty) with high conductivity copper conductor of size 12 Core X 1.5 sq mm as per Specn. No.IRS: S-63/2014 (Rev.4.0) with latest Amdt.if any. Inspection-RDSO Above/
UNDERGROUND RAILWAY JELLY FILLED TELECOM 6 QUAD CABLE 0.9 MM DIA FOR SIGNALLING AND TELECOM INSTALLATION CONFORMING TO SPECN.NO.IRS-TC-30/2005 VER-I WITH AMDT.- 5 OR LATEST. Inspection-RDSO Above/
UNDERGROUND, ARMOURED, UNSCREENED, RAILWAY POWER CABLE (STRANDED 7 X 1.40 MM) WITH HIGH CONDUCTIVITY CIRCULAR COPPER CONDUCTOR OF SIZE: 2 CORE X 10 SQ. MM AS PER SPECIFICATION NO. IRS:S 63/2014 & IS 1554 PART-1 REV.4.0. Inspection-RDSO Above/
Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to O.6 Mtrs 19 wide and back filling after placing of DWC / RCC/GI pipe. (Placing of DWC/ RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/ 009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. Per Above/
Termination of Outdoor Cables (Main Cables / tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee Above/
Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm only. Inspection: RDSO. (A) 1 WAY,DRG NO.23741A, ALT-4. Above/
Supply of fuse block (PBT) to spec.no.IRS-5- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 23748 with fuse inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: - RDSO. (A) Fuse, non- deteriorating(2A/6A/10A/16A) type, cylindrical(IRS-S-78/92) [quantity as per site requirement] Above/
Supply of fuse block (PBT) to spec.no.IRS-5- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 23748 with fuse inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: - RDSO. (B) Fuse Base. Above/
Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and 24 wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]. Note: - wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. Above/
Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. 25 mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re- arrangement of DC-DC converters by OEM of IPS. (A) Up to 6 Lines Station Above/
Installation and wiring of relay rack. Supply and fixing of fuses with base, diodes; resistances; condensers, terminal strips / tag blocks, bus bars & other equipment's required for the approved system design complete with scaffolding materials & required hardware & erection materials to accommodate 100 relays (station wise quantity to be specified by the tenderer). PVC wire 26 as per RDSO SPEC.IRS-5-76/89, AMD-2 or latest (for wiring of relay rack) shall be supplied by the contractor, duly inspected by RDSO. This includes supply of relay rack to accommodate 100 relays complete w ith fittings a s per DRG.NO.S&T/C-20/2001. Note: - this includes status of relay to be indicated through led indication at the top of relay rack and in this connection all the required materials to be supplied by the contractor. Rack to be fixed on rubber pad. (A) Supply. Inspection: (i) RITES if value of item in work more than 5 lakhs. (ii)Consignee if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Above/
Installation and wiring of relay rack. Supply and fixing of fuses with base, diodes; resistances; condensers, terminal strips / tag blocks, bus bars & other equipment's required for the approved system design complete with scaffolding materials & required hardware & erection materials to accommodate 100 relays (station wise quantity to be specified by the tenderer). PVC wire as per RDSO SPEC.IRS-5-76/89, AMD-2 or latest (for wiring of relay rack) shall be supplied by the contractor, duly inspected by RDSO. This includes supply of relay rack to accommodate 100 relays complete w ith fittings a s per DRG.NO.S&T/C-20/2001. Note: - this includes status of relay to be indicated through led indication at the top of relay rack and in this connection all the required materials to be supplied by the contractor. Rack to be fixed on rubber pad. (A) Execution. Above/
Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & 28 erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago/ Phoenix/Similar) , scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. (A) Supply. Inspection: (i) RITES if value of item in work more than 5 lakhs. (ii)Consignee if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Above/
Installation of cable termination rack with scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & 29 erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago/ Phoenix/Similar) , scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. (B) Execution. Above/
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. Inspection: by RITES [for value of material above Rs.5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] Above/
"Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg 31 = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod - 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of l50x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO" Above/
"Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion o f electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper a n d o u t e r surface 32 (minimum copper bonding thickness o f 2 5 0 microns t o made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover t h e earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee" Above/
"Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I) - 33 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT(galvanised) of size 35 mm x 6 mm (SPEC. NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25.. Inspection: - BY RITES [for value of material above Rs. 5.O lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]" Above/
Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25. (or latest). Inspection : by consignee. Above/
Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25. for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing M S fl a t a t apparatus cases/ signal post/other 35 equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. Above/
Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. Above/
Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock 37 & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy Above/
Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for 38 fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces- both inside and outside. Inspection: Consignee Above/
Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and 39 miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee Above/
Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries 40 in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (note-balance quantity may be taken from rly store if available) . (A) 950 x 400 x 25 MM for full size location box . Above/
Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. Above/
"Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. 42 Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside)" Above/
Supply of Medium class GI pipes 100 mm dia {4.5 mm thickneee} as per IS 1239 (Part 43 1}: 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Above/
Laying & Fixing of Medium class GI pipe 50/ 100 mm dia {4.5 mm thickness} as per IS 44 1239 {Part 1}: 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. GI Pipe Supplied By Rly. Above/
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 45 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a)for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway i s not available, 4 " o f 1:2:4 concreting should b e done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. Above/
Supply, Transportation at site and Installation of RCC cable route marker engraved and 46 painted on both side along the route at every 30 meter and at route diversion. The cable marker is to be fabricated as per RDSO drawing No. RDSO/Cable Laying/ 020, issued vide DRG. No. S.I.- S&T/1/2024. The fixing work is to be done as per extant practice of E. Rly. and as per Railway site supervisor. Above/
"Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto l75mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /te1ecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter 47 below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/ 2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided alongwith drum - 02 nos. Note:- cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer." Above/
Termination of new/ alteration of main/tail cables on the existing terminals/ fuse blocks 48 in apparatus cases/battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be re-painted / corrected on the doors of apparatus cases/ battery boxes/cable termination boxes and FTOT index board as instructed byRailway representative at site. This work includes alteration of lettering / painting, closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cablecompound.[Paints, wire PVC3/0.75mm and 16/0.2mm copper,sealing compound, bricks, cement,river sand and all other required miscellaneous materials shall be supplied by the contractor]. Above/
Supply of maintainer's furniture of godrej make or superior and each set consist of(i) 49 executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no.(iii) visitor chair seat & back cushion with high density foam with plastic pvc handle capsule type painted back-03 nOS. Inspection-consignee Running Above/
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item 50 includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Above/
Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: 5-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO Above/
Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA- 20161-66/ M or latest. Inspection: Consignee Per Track Above/
Installation wiring, testing and commissioning of single rail dc track circuit (TRACK CIRCUIT (BEYOND 200 MTRS.)) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables 53 with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. Per Track Above/
Installation wiring, testing and commissioning of single rail dc track circuit (SHORT LENGTH TRACK CIRCUIT UPTO 200 MTS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of 54 tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32" hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. Per Track Above/
Installation, wiring, testing & commissioning of track circuit involving Points & Crossings as per track circuiting plan, track battery charging and installation including drilling 9/32" hole on rails; fixing of bonding(double) with 8 SWG soft GI wire, insulation of stretcher bars (leading & following), gauge / crossing tie plates involving cutting and riveting/welding of angle clit, split 55 stretcher bars, fixing of track lead junction box, rail connector with GI wire, track jumpering(double) with supporting arrangement for holding termination of track lead wires, including series jumpers, jumper wire terminals, track feed set(track chargers, resistance, fuses, battery etc.) As per approved IYD for point zone track circuit. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided. Above/
Supply of Track Lead Junction Box(TLJB) made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows:(a) TAB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TAB shall have two bakelite terminal block fitted horizontally : each bakelite 56 terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Alongwith each TA B , nickel chrome plated brass links(two nos.Of adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TAB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength t o be supplied alongwith TAB. Inspection: RDSO. NOTE : FRP Base TLJB should be as per Technical Policy 118 (Modified) of Typical Drg. No. SI/TYP/0096 vide Docket No.SG/219/4/0 Date 29.11.24 Above/
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Above/
Supply of B Type Choke as per RDSO Specn. No.IRS: S-65/83 (Airind. 1) or latest. Inspection: RDSO. Above/
"Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. 5- 69/M. Inspection: Consignee." Above/
Supply of GI wire 8 SWG (4mm dia) suitable for track circuit rail bonding. Inspection: Consignee Above/
Provision/Installation of bonding with GI wire 4mm dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm dia. holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee. Above/
Supply of unchanged Low Maintenance Lead Acid (LMLA) secondary c e l l , shelf mounting type conforming to RDSO Specn.No. IRS:5-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO (A) 2V, 80 AH Above/
Charging of lead acid cell (Secondary cell) of various capacities as per 63 Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of battery in circuit. Battery t o b e kept o n wooden rack. Inspection: Consignee. (A) 2V, 80AH Above/
Supply o f pressure Sensitive Adhesive Plasticized PVC Tapes having 20 mm Width, minimum 25 Meter length. The colour o f t h e tape shall b e decided b y Railway in charge. Make: Protex/Nippon/Anchor or better. Above/
"Supply o f Hea d Mounted Rechargeable Torch for industrial use as per following 65 specification. i) Long life Li-ion 2000mAh rechargeable battery. ii) 5 Watt Hi Power SMD LED. iii) Micro U S B charging recharges in 4-5 hours. iv) 3 Lighting Modes High-Low- Flashing. v) Upto 8 hours continuous light. vi) Adjustable & comfortable elastic headband. vii) 9 0 degrees adjustable lighting angle. Make-Philips, Wipro, Havells, Crompton or better." Inspection-consignee Above/
"Supply of Industrial vacuum cleaner wet & dry duty with 220 millibar vacuum 66 pressure, air flow rate 54 Liters/sec, suction hose length 3.5-meter, floor nozzle size -350 mm, power cord length-10 meter with 01 no motor of 1350 watt capacity with container capacity 35 Liter with filter dust class - G2 & filter area - 1 sq. meter with stainless steel body & container and operated voltage - 230 V AC. Make- Eureka Forbes/Panasonic, Deerma/ Dyson /Inalsa or better." Inspection- consignee Above/
Supply of Professional AC/DC clamp meter 3 Y digit , true RMS measurement, For 67 Measurement of DC/AC currents up to 1000A, Voltage up to 600V, resistance up to 40 MW and frequency up to 1 MHz with set of leads & carrying case. Model - DCM 39A or equivalent/ higher make Motwane/ Stanlay/ Fluke/Megger. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee Above/
Supply of Digital Cable Insulation Tester for measurement of cable insulation resistance with auto range 0-500 V DC. Motwani or from any reputed make. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee Above/
Supply of 4 digit Backlit LCD Hand Held True RMS Clamp Meter with iFlex as per specification to make - Fluke 376 FC or better. Inspection-consignee Above/
Supply of Digital Multimeter as per specification to make - Fluke 87V or better. Inspection-consignee
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CheckListAnnexItoVIIIUPDATED.pdf
ATTACHMENT
Annexure-IX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure_VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCCwithCorrectionSlips1to10.pdf
ATTACHMENT
LabourCess.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
TermsofPayment.July-25.pdf
ATTACHMENT
RevisionofTypicaldiagramEarthElectrode.pdf
ATTACHMENT
Foundation.pdf
ATTACHMENT
EarthElectrode.pdf
ATTACHMENT
TrackCircuit.pdf
ATTACHMENT
TECHNICALCIRCULARNO118Modified-UseofFRP_250919_152223.pdf
ATTACHMENT
TECHNICALCIRCULARNO108-CableRouteMarkerPoli_250925_155743.pdf
ATTACHMENT
CableTerminationRack.pdf
ATTACHMENT
Updatedtenderdocument_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .