Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | ₹17.8 L Quoted ₹20.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹21.1 LRejected-AOC NO 129 INDIRA NAGAR ATTIPATTU CHENNAI 120 | CHENNAI | 120 | ₹21.1 L | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | BRIHADISVARA CONTRACT WORKS PRIVATE LIMITED L1 | ADHITHAN L2 |
|---|---|---|---|---|---|
| 1.00 | Engaging the experianced skilled men in shift duties to attend minor repair work for trouble free operation of boiler Unit-I,II & III lift and daily checking of functioning of lifts, condition of car door, landing door and their locks, alarm systems, availability of permanent power supply for motors and associated switch gear. Including consumables and T&P's. | 1,440 | shifts | 1,073 ₹15,45,120 | 1,086 ₹15,63,840 |
| 2.00 | Maintenance works for Unit I, II & III boiler lifts:
a) Upkeeping of equipments properly adjusted, and they will use all reasonable care to maintain the lift in proper operating condition.
b) Periodical examination, lubrication, minor adjustments for all functioning & moving parts.
c) Cleaning of motors, controllers, sensors, limit switches, oscillator switches, timers and relays.
d) The electrical components like push buttons, floor position indicators, limit switches, oscillator switches, timer boards, relays, etc should be replaced if found defective.
e) Mechanical components like door locks, door beads, door rollers, gibbs, guide shoes, bearings etc shall be replaced if found defective.
f) Periodical examination and lubrication of all safety devices and governors.
g) The electrical components like controller, EM Brake, Floor switches, Floor Position indicator, limit switches, door locks and mechanical parts like gear, guide shoes and safety gear are covered under the scope of contractor and the major components like sheave, main suspension steel rope, doors, main V3F drive, door V3F drive and mother board shall be borne by TNPGCL.
h) Service calls should be attended and completed within 24 Hours of all days.
i) Supply of materials, consumables items and T&P’s for periodical service rectification of lift whenever required. Including consumables and T & P's. | 9 | Nos. | 57,767 ₹5,19,903 | 58,678 ₹5,28,102 |
| 3.00 | LOAD TESTING for certificate as per the prevaling act from the competent authority in every year. For load testing, transportation of materials and arranging for testing by the competent authority witnessing the load test and obtaining necessary Certificate to 1365kg Boiler lift. Including consumables and T&P's. | 3 | Nos. | 6,318 ₹18,954 | 6,653 ₹19,959 |
Tender Value
Refer Docs
EMD Value
₹21,400
Closing Date
27 Mar 2025, 2:00 pmClosed
SE MI NCTPS1 CH 120
O/o SE MI NCTPS1 CH 120
NCTPS I SE MI Circle AMC 25 26 BM Dn Lifts Daily maintenance and breakdown maintenance of Freight cum Passenger lift in Unit I II III Boiler from the date of taken over of site upto 31 03 2026
2025_EB_532337_1
CE SE MI NCTPS I 258 24 25
Open Tender
Power/Energy Projects/Products
365 days
Works
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹21,400
Yes
7 Mar 2026
14 Mar 2025
28 Mar 2025
14 Mar 2025
27 Mar 2025
14 Mar 2025
Amount
Engaging the experianced skilled men in shift duties to attend minor repair work for trouble free operation of boiler Unit-I,II & III lift and daily checking of functioning of lifts, condition of car door, landing door and their locks, alarm systems, availability of permanent power supply for motors and associated switch gear. Including consumables and T&P's.
Maintenance works for Unit I, II & III boiler lifts: a) Upkeeping of equipments properly adjusted, and they will use all reasonable care to maintain the lift in proper operating condition. b) Periodical examination, lubrication, minor adjustments for all functioning & moving parts. c) Cleaning of motors, controllers, sensors, limit switches, oscillator switches, timers and relays. d) The electrical components like push buttons, floor position indicators, limit switches, oscillator switches, timer boards, relays, etc should be replaced if found defective. e) Mechanical components like door locks, door beads, door rollers, gibbs, guide shoes, bearings etc shall be replaced if found defective. f) Periodical examination and lubrication of all safety devices and governors. g) The electrical components like controller, EM Brake, Floor switches, Floor Position indicator, limit switches, door locks and mechanical parts like gear, guide shoes and safety gear are covered under the scope of contractor and the major components like sheave, main suspension steel rope, doors, main V3F drive, door V3F drive and mother board shall be borne by TNPGCL. h) Service calls should be attended and completed within 24 Hours of all days. i) Supply of materials, consumables items and T&P’s for periodical service rectification of lift whenever required. Including consumables and T & P's.
LOAD TESTING for certificate as per the prevaling act from the competent authority in every year. For load testing, transportation of materials and arranging for testing by the competent authority witnessing the load test and obtaining necessary Certificate to 1365kg Boiler lift. Including consumables and T&P's.