Loading…
Loading…
Tender Value
₹3.6 L
EMD Value
₹7,255
Closing Date
29 Jul 2026, 3:00 pm3d left
Assistant Engineer ( E )
Assistant Engineer (E) NWESD-II, PWD (GNCTD) Pitampura Police Lines, Delhi
Replacement of Faulty Cable, Light of Volley Ball Center at SU Block Pitampura, Delhi.
2026_PWD_295744_1
34/AEEII/NWED/PWD/2026-27
Open Tender
Electrical Works
Works
Pitampura
Please refer Tender documents.
18 documents required · 18 mandatory
₹0
₹7,255
Yes
22 Jul 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | SH-I ONE Time Special Repair
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as reqd.
a) size 3.5 X 70 sq. mm | 80 | Mtrs. | 1,266 | ₹1,01,280 |
| 0.0 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size DWC/HDPE/ RCC/ HUME/METAL as required.
(a) 3.5 X 70 sq. mm Alu. Cable. | 100 | Mtrs. | 1,198 | ₹1,19,800 |
| 0.0 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
a) 63 mm dia (OD-63 mm & ID-51 mm nominal) | 100 | Mtrs. | 136 | ₹13,600 |
| 0.0 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a) 3½ X 70 sq. mm (38mm) | 2 | Nos. | 542 | ₹1,084 |
| 0.0 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
a) 250 A,36KA,FPMCCB | 1 | Nos. | 18,372 | ₹18,372 |
| 0.9 | b) 100 A,30KA,FPMCCB | 1 | Nos. | 8,127 | ₹8,127 |
| 0.0 | Providing and fixing of 2 mm thick duly powder coated and phosphated sheet steel enclosure for installation of upto 630A MCCB i/c connection, testing etc as required. | 1 | Nos. | 5,155 | ₹5,155 |
| 0.0 | Cutting of R.C.C. / Bitumen Road etc upto depth of 30 cm work, cutting by machine including making good as same as earlier and disposal of unserviceable material as per direction of Engineer - in- charge etc as required complete at site and no payment for other items by department. (Cost For 4 Cu.Mtr.) | 4 | Cu.Mtrs. | 4,453 | ₹17,812 |
| 0.0 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
a) 200 watt | 10 | Nos. | 4,550 | ₹45,500 |
| 0.0 | Supplying & fixing Hot press moulded SMC box of size 250 x 200 x 105 mm i/c S/F Aluminium Bus Bar of suitable size i/c Phase, Neutral and Earth link, including 1 no. 6A to 32A rating 240 V 10KA "C" curve SP MCB & 1 no. earth bar, 1 no. Neutral bar, DIN rail mounting with openable hinged door on street light pole as required complete with mounting bracket/arrangement made of 5 mm thick GI flat iron etc. complete as required at site. pole/wall etc as reqd. at site i/c dismantling of existing. | 10 | Nos. | 1,720 | ₹17,200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_393517.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].