Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹28.6 L
EMD Value
₹57,200
Closing Date
8 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
63 days
Expenditure
Capital (Works)
WORKS
11 conditions · 9 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor . For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Electrical arrangements for :a)PUDI (PDD) Yard Remodelling b) Removal of non standard layout and provision of additional loop line on down direction at Veppagunta(VGA) in Arakkonam(AJJ)-Renigunta(RU) section c)Provision of Electrically operated Lifting Barriers and Emergency Sliding Booms at leftover LC gates in Arakkonam(AJJ)-Renigunta(RU) section d)Arakkonam Junction (AJJ) -Road mobile unusual & restoration unit at AJJ
ME-29-II-1076-2025~SR
ME-29-II-1076-2025
Open
Works - General
90 Days
Chennai, Tamil Nadu
₹0
₹57,200
8 Jan 2026
18 Dec 2025
25 Dec 2025
97 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 28,60,838 | ||
| — | — | — | Above/ 306180.00 Below/P | ||
| a)Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 1260.00 | — | — | |
| — | — | — | Above/ 100700.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material within railway land complete in a manner as directed by the Section Engineer in charge at site. | — | 190.00 | — | — | |
| — | — | — | Above/ 1194340.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. | — | 190.00 | — | — | |
| — | — | — | Above/ 49200.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx25 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 2050.00 | — | — | |
| — | — | — | Above/ 57000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx50 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1900.00 | — | — | |
| — | — | — | Above/ 21000.00 Below/P | ||
| Laying/leading of 4 core 95 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx95 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 82350.00 Below/P | ||
| Laying of 50 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements like T-Joints ,L-Joints and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 50mm dia HDPE pipe alone will be supplied departmentally. | — | 3050.00 | — | — | |
| — | — | — | Above/ 72000.00 Below/P | ||
| Laying of 63 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements like T-Joints ,L-Joints and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 63mm dia HDPE pipe alone will be supplied departmentally. | — | 2400.00 | — | — | |
| — | — | — | Above/ 28575.00 Below/P | ||
| Installation,Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc, complete including supply / leading / laying / burying and concealing of GI strip 25 X 3 mm from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site.Note: 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. 2) LT Earthing arrangements alone will be supplied Departmentally. | — | 25.00 | — | — | |
| — | — | — | Above/ 4914.00 Below/P | ||
| Installation, Testing and commissioning of TPN MCB DB's with 40A/63A/100A,FP,RCBO as Incomer along with combination of SP/DP/FP,MCB's as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re- plastering and bringing back walls to original condition including painting the walls to original condition complete including all wiring and termination works complete and as per industrial practices in a manner as directed by Senior Section Engineer in charge at site.Note: MCB DB,MCB, RCBO, Cable adaptor box etc alone will be supplied Departmentally | — | 7.00 | — | — | |
| — | — | — | Above/ 370.00 Below/P | ||
| Installation, Testing and Commissioning of 125A TPN Switch Dis-connector Fuse Unit along with Enclosure onto wall or elsewhere using suitable mounting arrangements including all cable terminations complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 125A TPN SDF Unit with Enclosure alone will be supplied Departmentally | — | 1.00 | — | — | |
| — | — | — | Above/ 9225.00 Below/P | ||
| Installation,Testing and commissioning of 1200mm sweep BLDC ceiling fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord complete in a manner as directed by Senior Section Engineer in charge at site. Note: 1200mm sweep BLDC Ceiling fan alone will be supplied departmentally. | — | 41.00 | — | — | |
| — | — | — | Above/ 120600.00 Below/P | ||
| Erection, testing and commissioning of 4 meter Double arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation ,testing and commissioning of LED luminaries including all wiring works from nearby junction box as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work .2) Four metre Double arm Octagonal pole and accessories along with luminaries alone will be supplied departmentally. | — | 40.00 | — | — | |
| — | — | — | Above/ 16568.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 20W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 152.00 | — | — | |
| — | — | — | Above/ 8720.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 40W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 40W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 80.00 | — | — | |
| — | — | — | Above/ 104100.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 22 below complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 347.00 | — | — | |
| — | — | — | Above/ 10290.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 22 below complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 30.00 | — | — | |
| — | — | — | Above/ 27300.00 Below/P | ||
| Drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 22 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose and will be supplied Departmentally | — | 2100.00 | — | — | |
| — | — | — | Above/ 2960.00 Below/P | ||
| Installation, Testing and commissioning of the 300mm sweep BLDC Exhaust fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 300mm sweep BLDC Exhaust fan alone will be supplied departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 31980.00 Below/P | ||
| Drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 22 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken as 1m for quantity purpose and will be supplied Departmentally | — | 2460.00 | — | — | |
| — | — | — | Above/ 50576.00 Below/P | ||
| Drawing of earth wire using 1.5 sq.mm fire retardant Low smoke PVC insulated [green colour] unsheathed single copper conductor cables duly along wires vide item No's 18, 20 above and light and fan points vide item No's 16 and 17 above or elsewhere complete in a manner as directed by Senior Section Engineer in charge at site. Note: 1.5 sq.mm wire alone will be supplied departmentally. | — | 6322.00 | — | — | |
| — | — | — | Above/ 104656.00 Below/P | ||
| Concealing of 25mm dia rigid PVC conduits [IVORY colour] along with all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note:25 mm dia PVC conduit pipe,Bends,Junction Boxes etc alone will be supplied Departmentally | — | 3376.00 | — | — | |
| — | — | — | Above/ 733.00 Below/P | ||
| Installation, Testing and commissioning of SPN MCB DB's with 32A,DP,MCB as Incomer along with 6 No's of 16A,SP ,MCB's as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete including all cabling and termination works complete as per site conditions and as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. Note: MCB DB,MCB, Cable adaptor box etc alone will be supplied Departmentally | — | 1.00 | — | — | |
| — | — | — | Above/ 14963.00 Below/P | ||
| Installation, Testing and commissioning of 600mm sweep BLDC Air circulators onto wall / stanchion / rail post or elsewhere using suitable suitable clamping arrangement made of 40mm X 6mm MS flat and MS plate of size of 300mm X 300mm X 6mm complete in a manner as per standard industrial standards and in a manner as directed by Section Engineer in charge at site. Note: 600mm sweep BLDC Air circulators alone will be supplied Departmentally. | — | 13.00 | — | — | |
| — | — | — | Above/ 2340.00 Below/P | ||
| Installation, Testing and commissioning of the 400mm sweep BLDC Wall Mounting fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 400mm sweep BLDC Wall Mounting fan alone will be supplied departmentally. | — | 12.00 | — | — | |
| — | — | — | Above/ 800.00 Below/P | ||
| Laying/Leading of 3 core 6 sq. mm PVC insulated copper conductor flat submersible cable in a manner as directed by Section Engineer in charge at site Note: 3 core 6 sq.mm PVC Cable alone will be supplied Departmentally. | — | 100.00 | — | — | |
| — | — | — | Above/ 3990.00 Below/P | ||
| Installation,Testing and commissioning of of time switch assembly comprising of: - a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz]. b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well- seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. Note:Timerswitch,Power contactor,MCB,Neutral Link,Earth link,fuses,wooden box,enclosures alone will be supplied Departmentally. | — | 7.00 | — | — | |
| — | — | — | Above/ 17500.00 Below/P | ||
| Installation,Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No.GSJB-1414 along with strip connector block,Neutral link,fuse bases and carriers onto lamp posts or elsewhere suing suitable clamping arrangements including all cabling and termination works complete as per site conditions and in a manner as directed by Section Engineer incharge at site Note: SMC GSJB-1414 box, strip connector , neutral link, Earth link ,Fuse bases and fuse carriers, MS clamping arrangements alone will be supplied Departmentally. | — | 140.00 | — | — | |
| — | — | — | Above/ 49070.00 Below/P | ||
| Excavation of cable trench 0.45m wide x 1.2 m deep under railway tracks (from formation levels).duly removing stone ballast, back filling of the excavated cable trench(after laying of cable with HDPE pipe),ramming & consolidation properly and providing back the removed stone ballasts complete in a manner as directed by Section Engineer incharge at site. | — | 35.00 | — | — | |
| — | — | — | Above/ 69840.00 Below/P | ||
| a)Removal of existing 4m Double arm Octagonal poles with Lights and other accessories available along with pole complete as per site conditions ,the surface where octagonal poles is removed should be brought to original condition including refilling of Mass Concrete. b)Erection, testing and commissioning of removed 4 meter Double arm octagonal pole assembly onto the suitable RCC foundation and coping by using modern engineering practice including installation ,testing and commissioning of LED luminaries including all wiring works from nearby junction box as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation design and drawing along with supporting IS specifications suitable for Octagonal poles supplied by Railways and as per site conditions should be submitted for approval before starting the work. 2)Bolts, Nuts and other accessories required for successful Erection, Testing and commissioning of Removed Octagonal poles should be as per OEM standards and necessary approval must be obtained before starting the work for the same shall be under scope of Contractor 3)Minor repair works if required as per site conditions while Refixing the Removed Octagonal poles is also covered under scope of Contractor. | — | 16.00 | — | — | |
| — | — | — | Above/ 242900.00 Below/P | ||
| Erection, testing and commissioning of 300mm width x 50mm height made of 2mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated MS flats of sufficient thickness and same duly supported from walls/ceiling/roof purloins/steel members of platform shelter/Foot over Bridge or elsewhere using intermediate supports of MS flats complete including carrying out all civil works incidental to provision/supporting/grouting of cable tray supports complete as per industrial standards ,site conditions and in a manner as directed by Section Engineer-in-charge at site. Note: 1)The cable tray supports shall be applied with two coats of red oxide primer and finished with two coats of bright aluminium paint. 2)Cable tray alone will be supplied Departmentally | — | 700.00 | — | — | |
| — | — | — | Above/ 2500.00 Below/P | ||
| Removal of existing wiring complete including removal of conduit pipe and other accessories required complete and handing over to SSE/Electrical/Power Office at Arakkonam . | — | 500.00 | — | — | |
| — | — | — | Above/ 10360.00 Below/P | ||
| Installation,Testing and commissioning of 80 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 80W LED Street light fittings alone will be supplied departmentally. | — | 40.00 | — | — | |
| — | — | — | Above/ 109.00 Below/P | ||
| Installation,Testing and commissioning of 100A , FP RCBO with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements including all cabling and terminations complete as per site conditions and as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note: 100A,FP,RCBO with Enclosure alone will be supplied Departmentally. | — | 1.00 | — | — | |
| — | — | — | Above/ 4616.00 Below/P | ||
| Erection, Testing and commissioning of 2 HP energy efficient five star submersible pump set including control panel , suitable for 200 dia BORE WELL and suitable for operation on three phase AC supply complete along with all accessories including fixing and mounting arrangements complete and conforming to the specification enclosed and as per industrial standards in a manner as directed by Section engineer in charge at site. Note:2 HP BORE WELL Submersible pump with Control panel assembly alone will be supplied Departmentally | — | 2.00 | — | — | |
| — | — | — | Above/ 14580.00 Below/P | ||
| Removal of existing rail posts by cutting at a depth as per site condition ground level including breaking of cement concrete and refilling with all accessories including bringing surface to original condition including refilling of Mass Concrete complete in a manner as directed by section engineer incharge at site. Note: The removed Rail posts must be handed over to SSE/Electrical/Power Office at Arakkonam . | — | 12.00 | — | — | |
| — | — | — | Above/ 4257.00 Below/P | ||
| Erection, Testing and commissioning of 12 way Floor Mounting Type MCCB DB with 125A, FP,MCCB as Incomer along with (2 No's 63A+6 No's 32A+2 no's 16A) ,FP,MCCB's as outgoing including all cable termination at both Incoming and Outgoing sides complete and as per industrial practices complete in a manner as directed by Senior Section Engineer in charge at site. Note: MCCB DB, ,MCCB alone will be supplied Departmentally | — | 1.00 | — | — | |
| — | — | — | Above/ 2592.00 Below/P | ||
| Installation,Testing and commissioning of 45 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards including cabling and terminations complete in a manner as directed by Section Engineer in charge at site. Note: 45W LED Street light fittings alone will be supplied departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 1960.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 12 modules, switches, sockets, blank plates etc. and 1 No DP modular type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete ,replastering painting etc.,complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -12 module Frame plate with matching cover plate, DP modular type MCB, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 10.00 | — | — | |
| — | — | — | Above/ 1900.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 8 modules, switches, sockets, blank plates etc. and 1 No DP modular type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete ,replastering painting etc.,complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -8 module Frame plate with matching cover plate, DP modular type MCB, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 10.00 | — | — | |
| — | — | — | Above/ 2784.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 6 modules, switches, sockets, blank plates etc. and 1 No DP modular type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete ,replastering painting etc.,complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -6 module Frame plate with matching cover plate, DP modular type MCB, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 1648.00 Below/P | ||
| Installation ,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 4 modules, switches, sockets, blank plates etc. duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including all wiring works complete including replastering painting etc.,complete and in a manner as directed by Senior Section Engineer in charge at site. Note: -4 module Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied Departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 2480.00 Below/P | ||
| Supply, Installation, Testing and commissioning of metal junction box(switchboard of size 200mmx150mmx50mm fabricated with 16 gauge steel an provided with 3mm thick decolam sheet top, knockout, and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including including all wiring works complete replastering painting etc., complete and in a manner as directed by Senior Section Engineer in charge at site | — | 16.00 | — | — | |
| — | — | — | Above/ 380.00 Below/P | ||
| Installation,Testing and commissioning of 32A , DP,MCB with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements as per industrial standards including all wiring works complete in a manner as directed by Section Engineer in charge at site. Note: 32A,DP,MCB with Enclosure alone will be supplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 1736.00 Below/P | ||
| Installation, Testing and commissioning of 0-60A CT operated Multifunction Energy Meter with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements complete including all wiring conection works complete as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 0-60A CT operated Multi Function Meter with Enclosure alone will be supplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 72.00 Below/P | ||
| Installation, Testing and Commissioning including concealing work along with metal clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 25 A,DP, RCBO onto the walls including cutting/chipping and replastering and bringing back walls to original condition including all wiring cabling and termination works, painting in a manner as directed by section engineer in charge at site. Note: Metal clad plug and socket with Enclosure and RCBO alone will be supplied Departmentally. | — | 1.00 | — | — | |
| — | — | — | Above/ 2770.00 Below/P | ||
| Installation,Testing and commissioning of 150W LED HighBay light fittings using suitable mounting and fixing arrangements as per industrial standards including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord complete in a manner as directed by Section Engineer in charge at site. Note: 150W LED HighBay light fitting alone will be supplied departmentally. | — | 10.00 | — | — | |
| — | — | — | Above/ 354.00 Below/P | ||
| Installation, Testing and Commissioning of 32A TPN Switch Dis-connector Fuse Unit along with Enclosure onto wall or elsewhere using suitable mounting arrangements including all cabling and termination works complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 32A TPN SDF Unit with Enclosure alone will be supplied Departmentally | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Checklist.pdf
ATTACHMENT
EarthingType1032.pdf
ATTACHMENT
Earthing.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
GCCACS1.pdf
ATTACHMENT
GCCACS2.pdf
ATTACHMENT
GCCACS3.pdf
ATTACHMENT
IRSGCCACS4.pdf
ATTACHMENT
IRSGCCACS5.pdf
ATTACHMENT
IRSGCCACS6.pdf
ATTACHMENT
IRSGCCACS7.pdf
ATTACHMENT
IRSGCCACS8.pdf
ATTACHMENT
IRSGCCACS9.pdf
ATTACHMENT
IRSGCCACS10.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
Generalinstructionstotenderers.pdf
ATTACHMENT
SpecialconditionsofContractElectrical.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
SpecificationforlayingUndergroundcable.pdf
ATTACHMENT
specificationforwiringandrewiring.pdf
ATTACHMENT
TSQTYBREAKUPDETAILS.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .