Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.3 L+₹22,240 (1.70%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹15.1 L+₹2.0 L (15.3%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-Finance L1 being accepted | |
| 4 | Rejected-Technical ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | - | Rejected-Technical The firm has not been enlisted for eligible category i.e. c(i). Hence it is recommended to reject the bid submitted by the firm. | |
| 5 | Rejected-Technical | - | Rejected-Technical The firm has not been enlisted for eligible category i.e. c(i). Hence it is recommended to reject the bid submitted by the firm. |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAMTIRUNELVELI
REPAIRS / REPLACEMENT OF SUMMER COLLING APPLIANCE AT PARUNDU UNDER GE TIRUNELVELI
2020_MES_384806_1
GE/TVL/8123
Open Tender
Miscellaneous Works
Item Rate
330 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹24,000
Yes
27 Jan 2021
9 Oct 2020
6 Nov 2020
9 Oct 2020
4 Nov 2020
22 Oct 2020
9 Oct 2020 - 17 Oct 2020
60 days
Amount
SCHEDULE 'A' PART -I(E/M PORTION)
Providing comprehensive annual maintenance periodical/preventive maintenance including annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as listed in particular specification as per manufacturer specification at INS PARUNDU RAMNAD by providing one AC/Refrigeration mechanic each for one general shift all as specifide and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grills & filters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerent pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g) Replacement of faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling applicances of any make & capacity with job card Note:- General Shift ( 900 Hrs to 1700 Hrs)- One Ref Mech.
Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as directed.
Capacitor 60 MFD.
Air filters.
Condenser fan motor 1.5 HP with blade set .
Blower fan motor 1.6 HP with blade set. Make:
Blower with circular leaf.
Copper condenser coil unit (for A/C)
Copper cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD. Make:
Stainer tube (copper)
Capillary tube (copper)
Non return valve (For gas top up charging)
Remote control suitable for Non inverter model Split AC. Make : LG
Remote control suitable for Non inverter model Split AC. Make : Bluestar
Remote control suitable for Non inverter model Split AC. Make : Daiken
Remote control suitable for Non inverter model Split AC. Make : Universal
Remote control suitable for inverter model Split AC. Make : Bluestar
Remote control suitable for inverter model Split AC. Make : Daiken
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : LG
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Bluestar
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Daiken
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken
Copper pipe of size 1/2" for suction line with foam insulation
Copper pipe of size 1/4" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply and fix PVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
Metal plug top for AC
Supply only the new following items for for 3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
Air filters.
Condenser fan motor with blade set .
Blower fan motor with blade set.
Blower with circular leaf.
Condenser coil unit (for A/C)
Cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD.
Stainer tube (copper)
Capillary tube (copper)
Non return valve (For gas top up charging)
Remote control suitable for Non inverter Tower AC.
PCB board suitable for outdoor unit.
PCB board suitable for indoor unit.
Copper pipe of size 5/8" for suction line with foam insulation
Copper pipe of size 3/8" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply and fix PVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
Three phase metal plug top
Supply only the new following items for water cooler 40/80 Litres capacity including testing and commissioning etc complete all as directed.
Relay unit
PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm.
Thermostat asssembly
Water tap suitable for water cooler.
Starting Capacitor 80-100 MFD
Running capcitor 36 MFD
Condenser fan motor 1.6HP with blade set
Over load protector (OLP)
Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic
Split type AC 2.0 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic
Water cooler 40/80 Litres capacity . Make: Samsung or Voltas /LG/Bluestar
Floor standing/Tower AC 3 Ton Capacity. Make : Voltas or LG/Bluestar/Samsung
Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed.
Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity
M & L Painting complete with super enamel paint of approved colour for water cooler all as specified and directed.
Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
Supply only R22 /R32 /R410 Gas complete all as specified and directed.
Supply only R134a Gas complete all as specified and directed.
Dismantling and dis connecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :- NOTE : The wt of refrigerent used for filling/top up shall be measured and paid under respective item.
Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner
Materia and lobour for making good of surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete.
RK ENTERPRISES
sri manikandan enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .