Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.5 Cr+₹1.9 L (1.33%)Rejected-Finance | ₹1.5 Cr+₹1.9 L (1.33%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.6 Cr+₹14.6 L (10.1%)Rejected-Finance | ₹1.6 Cr+₹14.6 L (10.1%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹1.8 Cr+₹36.0 L (25.0%)Rejected-Finance SAHEED UDHAM SINGH NAGAR THANDI KHUEE SUJANPUR PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | ₹1.8 Cr+₹36.0 L (25.0%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹1.9 Cr+₹42.7 L (29.6%)Rejected-Finance | ₹1.9 Cr+₹42.7 L (29.6%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹2.0 Cr
EMD Value
₹2.7 L
Closing Date
31 Mar 2022, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
Addition/ Alteration of JCOs/ OR family Qtrs at Manekshaw Enclave at Tibri
2022_MES_501982_1
81024/E8
Open Tender
Civil Works
Item Rate
270 days
Tibri Gurdaspur
All as per NIT documents
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Gurdaspur
₹2.7 L
Yes
19 May 2022
26 Jan 2022
2 Apr 2022
26 Jan 2022
31 Mar 2022
14 Mar 2022
Amount
Note: Please refer Schedule 'A' Notes given on serial page No. 22 to 24 of tender documents.
LIST OF WORKS FOR BUILDING WORKS
Dismantling brick tiles or terracing tiles single layer on roofs complete all as specified and directed by Engineer-in-Charge.
Demolition of mud phuska in roofs any thickness including plastering and leeping and removing rubbish off from the site complete all as specified and directed. Note:- The rate of removal of rubbish is deemed to be included in quoted rate.
Roughening old surfaces of concrete floors by picking, sweeping clean and washing down with water to clean the surface and applying cement slurry @ 3.00 Kg per sqm complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Material and labour for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof padding averaging thickness of 50mm complete all as specified and directed.
Material and labour for 10mm thick plaster in cement mortar 1:3 using water proofing compound on RCC roof slab including cleaning of existing surface complete all specified and directed. Note : WPC shall be measured and paid separately under respective item.
Material and labour for 3mm thick superior Atactic Polypropylene modified polymeric membrane waterproofing treatment of weight not less than 3.6 Kg per sqm with properties of high penetration and the centre core consisting of 90 micron High Molecular-High Density Polyethylene (HMHDPE) film consisting of five layers. The superior multi polyplus is to be laid after preparing the surfaces by cleaning thoroughly to achieve a smooth surface over and including a coat of bitumen primer @ 0.30 litre per sqm and finally it will be finished with two coats of aluminium paint @0.20 litre/ Sqm for each coat. The overlaps between super multi polyplus are minimum 10cm seam in width/lengthwise complete all as specified and all as per manufacturer’s directions.
Demolition of cement concrete above ground floor any thickness and in any position complete all as specified and directed.
M&L plaster 15mm thick in cement mortar 1:3 in sunken portion of slab using water proofing compound and providing 3mm thick superior Atactic Polyprophylene modified ploymeric membrane waterproofing treatment of weight not less that 3.6 Kg per sqm with properties of high penetration and the centre core consiting of 90 micron high molecular -High Density polyethylen (HMHDPE) film consiting of 5 layers. The superior multi polyplus is to be laid after preparing the surface by cleaning throughly to achieve a smooth surface over and including a coat of bitumen primer @ 0.30 ltrs per sqm. The overlaps between super multi polyplus are minimum 10cm seam in width/lengthwise complete all as specified and all as per manufacturer’s directions. Note : Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound conforming to IS-2645 complete all as specified.
Material and labour for lime concrete in lime mortar 1:3 using 40mm graded broken brick aggregate for sunken portion etc., complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 25mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in sub base to receive the top layer complete all as specified and directed.
Material and labour for 12mm thick cement plastering in cement mortar 1:6 on brick or concrete surfaces other than fair surfaces, finished the surfaces even and smooth without using extra cement and applying two coats of oil bound distemper over a coat of primer on plastered surfaces including taking down existing plaster complete all as specified.
Material and labour for 12mm thick cement plastering in cement mortar 1:6 on brick or concrete surfaces other than fair surfaces, finished the surfaces even and smooth without using extra cement and applying three coats of white wash on wall plastered surfaces including taking down existing plaster complete all as specified.
Material and labour for 5mm thick cement plastering on ceiling in cement mortar 1:3 and applying three coats of white wash on plastered surfaces including taking down existing plaster complete all as specified.
Material and labour for 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth without using extra cement in cement mortar 1:4 using WPC including taking down existing plaster upto height 12.0 mtr complete all as specified. Note: WPC shall be measured and paid for separately.
Material and labour for preparation of new plastered surfaces and applying two coats of cement base paint over one coat of primer, upto height 12.0 mtr complete all specified and directed.
Material and labour for preparation of old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
Material and labour for complete removing of existing treatment from walls and applying wall care putty not less than 1mm thick and applying and two coats of oil bound distemper complete all as specified.
Material and labour for preparation of old decorated wall surfaces and applying one coat of white wash complete all as specified and directed.
Taking down chowkhats with shutter not exceeding 1.50 sqm each (without taking off shutter from the chowkhats) and removing to store complete all as specified.
Taking down chowkhats with shutter exceeding 1.50 sqm but not exceeding 4.0 sqm each (without taking off shutter from the chowkhats) and removing to store complete all as specified.
Supply and fixing pressed steel frame for doors with one or more rebate including necessary fixing lugs, hings, lock strike, plate etc complete of size 105x60mm all as specified including two coats of painting over a coat of primer and filling PCC 1:2:4 (Type B-0) in the frames complete all as specified.
Supply and fixing pressed steel frame for doors with one or more rebate including necessary fixing lugs, hings, lock strike, plate etc complete of size 125x60mm all as specified including two coats of painting over a coat of primer and filling PCC 1:2:4 (Type B-0) in the frames complete all as specified.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style)consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site all as specified in clause 8.34.2.1 of SSR Part-I as directed.
Supply and fixing factory made flush shutters 32mm thick, both side laminated, soild core consturction, with block board core and decorative face panels as decided by GE, on both sides complete all as specified and directed.
Supply and fixing glazed or skeleton shutter 35mm thick, 2nd class hard wood factory made open rebated prepared to receive gauge etc without sash bars, edges of framing plain fitted with cut and mitred beads for securing gauge etc, size of member all as per clause 8.24 Para (a) of Section 8, SSR-2009 (Part-I), complete all as specified and directed. Note:- Wire gauge shall be measured and paid for separately.
Supply and fixing in repair prelaminated particle board gauge, 25mm thick, interior grade, prelaminated both side with decorative choice lamination & other side balacning white lamination, fixed with screws to timber frame work incluidng 6mm thick 2nd class hard wood lipping all around complete all as specified and directed.
Supply and fixing in repair 18/19 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
Supply and fixing galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks, complete all as specified and as directed.
Supply & fixing continuous (piano) hinges, mild steel, bright finish or electro galvanised of 40mm width of flaps complete all specified and directed.
Supply and fixing aluminium anodised barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and as directed.
Supply and fixing aluminium anodised barrel tower bolts of extruded section 200mm long (ISI Marked) complete all as specified and as directed.
Supply and fixing extruded aluminium alloy handle fabricated type anodized of size 125mm long (ISI Marked) complete all as specified and as directed.
Supply and fixing extruded aluminium alloy handle fabricated type anodized of size 150mm long (ISI Marked) complete all as specified and as directed.
Supply and fixing 75 mm size hasp and staple, (ISI Marked) safety type, stainless steel with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
Supply and fixing in repair 300 mm long aluminium alloy, anodised sliding door bolts, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI Marked) and fixed complete all as specified.
Supply and fixing 300 mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. Note:- Quoted rate shall be deemed to include the cost of repair required on steel door frame, welding to be carried out or necessary alternative arrangements to be done.
Supplying and fixing Box type steel windows 1.25 mm thick (primer coated) ERW hollow ‘P’ section of size 60mmx25mm double rebated comprises of glazed and skeleton shutter including guard bar ERW section 50mmx20mm and 1mm thick and two openable leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 using 20mm graded stone aggregate including taking down existing window including following fittings welded to framed shutter :- (a) Holdfasts 150mm long of MS flat iron12mmx3mm made to shape -04 Nos per window (b) Handle of Z section 20mmx25mm, 100mm long -01 No per leaf (c) MS tower bolt 150mm long -02 Nos per leaf. (d) Stopper Z section 20mm x 25mm, 100 long -01 No per leaf (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges -02 No per leaf. (f) MS pintal hinges of size 75mmx12mm -02 Nos per leaf. (g) Fabrication and fixing arrangement as per drawing No CEJZ/TD/1019, Sh 1/3 to 3/3 and No. CEJZ/TD/1020, Sh 1/3 to 3/3. Note: Wire gauge and painting shall be measured and paid for separately. (h) MS guard bar 12mm square bar @ 12cm centre to centre fixed horizontally.
Material and labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame (single rebated), comprising glazed shutter, frame of ERW tube and flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as stopper, cleat, pintal hinges, holdfast etc all as shown on drg No. CEJZ/TD-1019/08 Sheet 1/3 to 3/3 dated 01 May 2008 including cutting holes and taking down old steel ventilator complete all as specified. Note for item No 40 & 41:- (i) Sheet glass,Wire gauge and painting shall be measured and paid separately. (ii) Drg No. CEJZ/TD-1019 & 1020 Sh 1/3 to 3/3 are not being uploaded and the same can be seen in GE office during any working day.
Hacking out old broken (any thickness, size, quality or description) from wooden/ steel frame, glazed with putty and fixed with beads complete all as specified and directed.
Supply and fixing sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Supply and fixing figured glass, pin head type, 4 mm thick (frosted glass) glazed with oil putty not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Supplying and fixing Rotational moulded polythene water storage tank triple layered white 500 litre capacity (Cylindrical vertical with closed top) hoisted in position including dismantling of existing water tanks, including 20mm brass float valve complete all as specified and directed by Engineer –in-Charge.
Disconnecting existing water tanks of any capacity setting aside for repairs cleaning and removing all scale and dirt etc from tank and mouths of circulating pipes and re-fixing in position, complete all as specified and directed.
Dismantling existing water tanks of capacity 500 ltrs (Cylinder vertical with closed top) any type and removing to store complete all as specified and as directed.
Taking up or down old steel tubing including fittings 15mm bore including cleaning for reuse or removal to store complete all as specified and directed.
Taking up or down old steel tubing including fittings 20mm bore including cleaning for reuse or removal to store complete all as specified and directed.
Taking up or down old steel tubing including fittings 40mm bore including cleaning for reuse or removal to store complete all as specified and directed.
Supply and fixing of 15mm bore medium grade GI tubing with and including all fittings & cutting, threading at both ends to required size, and fixed to walls, to ceilings or laid under floors, making good all the disturbed portions complete all as specified and as directed by the Engineer-in-Charge
All as per description of serial item No 51.00 here in before but fixing only (old serviceable pipe retrieved from srl item No. 48 shall be re-used)
Supply and fixing of 20mm bore medium grade GI tubing with and including all fittings & cutting, threading at both ends to required size, and fixed to walls, to ceilings or laid under floors, making good all the disturbed portions complete all as specified and as directed by the Engineer-in-Charge
All as per description of serial item No 53.00 here in before but fixing only (old serviceable pipe retrieved from srl item No. 49 shall be re-used)
Supply and fixing of 40mm bore medium grade GI tubing with and including all fittings & cutting, threading at both ends to required size, and fixed to walls, to ceilings or laid under floors, making good all the disturbed portions complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing in repair 15mm bore bib tap cast copper, chromium plated, long body fancy type with crutch or butter fly handle, screwed down, screwed for iron pipe in repairs complete all as specified and directed.
Supply and fixing in repair of 15mm bore stop valve/ angle cock cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
Supply and fixing in repair 20mm bore stop valve cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
Supply and fixing in repair CP shower rose 125mm size with swivel joint fancy type all as specified and directed.
Supply and fixing CP brass towel rail 'D' type, 60cm long, fixed to wall complete all as specired and directed.
Supply and fixing in repair vitreous china squatting pan "Orrisa Pattern" white of size 580x440m with integral foot rest with 'P' or 'S' trap, including water connection to trap and flushing pipe, flushing cistern etc complete and bedding in and including lime concrete in lime mortar 1:3 using broken bricks 40mm graded aggregate complete all as specified. Note:- Flush pipe and flushing cistern to be measured and paid separately.
Supply and fixing in repair vitreous china wash down water closet pan ( Pedestal pattern) white (excluding flushing cistern and flush pipe) including plastic water closet seat white with Jet, closed pattern with flat botton and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
Supply and fixing in repair PVC 10 litre syphonic action type flushing cistern, low level with inlet, ball valve, float and handle (ISI Marked) including brackets, flush pipe PVC 32mm bore and connection to WC complete all as specified and directed.
Supply and fixing in repair PVC connections 15mm size with PTMT nuts, of length 450mm complete all as specified and directed.
Supply and fixing in repair Vitreous China wash hand basin, white, flat back of size 630mm x 450mm including brass coupling, waste pipe, mild steel brackets fixed to wall, complete all as specified and directed.
Supply and fixing in repair pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP bracket guard and railing 60cm long complete all as specified.
Supply and fixing in repair towel ring of chromium plated fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)size complete all as specified.
Dismantling of cast iron or PVC or SGSW drain pipe, jointed in cement mortar and taking out of trenches, if required
Supply and fixing 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to wall or in floor scomplete all as specified and directed.
Supply and fixing 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to wall or in floors complete all as specified and directed.
Supply and fixing PVC (SWR) bends of any radius of 110 mm bore, complete all as specified and directed.
Supply and fixing PVC (SWR) bends of any radius of 75 mm bore, complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) double junction (double T cross) equal or unequal with oval acess door complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) double junction (double T cross) equal or unequal with oval acess door complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) single junction (Single 'T' ) equal or unequal complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) single junction (Single 'T' ) equal or unequal complete all as specified and directed.
Supply and fixing 110 mm PVC (SWR) vent cowl fixed complete all as specified
Supply and fixing 75 mm PVC (SWR) vent cowl fixed complete all as specified
Material and labour PVC (SWR) floor trap 100/75mm plain with grating including jointing with solvent cement complete all as specified and directed.
Supply and fixing of stack clamps made out of 50x5mm flat iron and 16mm dia round iron stays including nuts and bolts and securing end of stays to wall or in roof, for 110mm bore pipes complete all as specified and directed.
Supply and fixing of stack clamps made out of 50x5mm flat iron and 16mm dia round iron stays including nuts and bolts and securing end of stays to wall or in roof, for 75mm bore pipes complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
Material and labour for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Material and labour for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint, complete all as specified and directed.
All as per description of serial item No 86.00 here in before but on steel/ iron surfaces complete all as specified.
Supply and fixing in repair curtain rod 20mm dia of anodised aluminium alloy decorative, with fixing brackets, stops, roller etc fixed to wall with screws, PVC plug/ cement lime mortar including taking down existing curtain rod complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc all complete all as specified directed.
Material and labour for brick work with fly ash bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for brick work with fly ash bricks straight or curved on plan exceeding 6m mean radius with old size bricks in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified.
Material and labour for green marble work 14mm to 16mm thick (table rubbed and polished) in steps, jambs, pillars window cills , cooking platforms , stair case and the like with bull nosing in cement mortar ( 1:4) incl pointing in white cement ( 1:2) using marble dust with admixture of pigment to match with marble shade including making grooves for slip guard on steps, edge moulding, making 30mm dia hole in cooking counter slab & green marble top for gas pipe complete all as specified, directed and approved by Engineer-in-charge
Supply and fixing Sinks with drainge board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers, waste coupling and waste pipe , including cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm, bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
Material and labour for 100 mm thick cement concrete 1:4:8 type D-2, (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
Material and labour for 60mm thick machine pressed precast concrete coloured (mixed with white cement and marble powder) interlocking paver block and shape and size confirming to IS 15658-2006 of M-35 Grade with grey cement and pigment laid over sand cushioning consolidated with plate vibrater complete all as specified and directed. Note:- (i) The sample shall be got approved from the GE before bulk procurement and lots shall be got tested independently by the GE. (ii) Sand cushioning will be measured & paid for separately.
Material and labour for sand filling under floors including watering and consolidation complete all as specified and directed. Note:- Punned down thickness shall be measured for payment.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground floor) and removing surplus spoil out of defence land where directed.
Material and labour cement concrete type B-1 (1:2:4) (20mm graded aggregate) as in plinth protection thickness of 50mm without using extra cement complete all as specified.
Material and labour for non skid coloured ceramic tiles (premium quality) 7 to 8mm thick joint free square/ rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 after roughening surface of old concrete floor by picking, sweeping and washing down with water to remove dust complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles of premium quality, size 350x250x7mm/ 450mmx350mmx7mm/ 300x200x7mm thick joint free as on vertical surfaces such as dado/skirting etc laid over and including 10mm thick screed in cement mortar 1:4, set and jointed in neat cement slurry and pointing in white cement with pigment to match, including taking down existing tiles & cement mortar bedding and removing the rubbish to a distance all as directed by Engineer-in-Charge.
Material and labour Non skid coloured ceramic tiles (premium quality) 7 to 8mm thick joint free square/ rectangular, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 including taking down existing tiles & cement mortar bedding and removing the rubbish to a distance all as directed by Engineer-in-Charge.
Material and labour for glazed ceramic coloured tiles in vertical surface 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in coloured pigment to match over and including 10mm thick rendering in cement mortar 1:4 including taking down cement plaster/ skirting complete all as specified and as directed.
Material and labour for repairing of RCC projections, chajjas , roofs, facia etc. by necessary preparation i.e. scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, sufaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete 1:1.5.3 type A-0 (using 12.5mm graded crushed stone aggregate) and reinforced with welded mesh of weight exceeding 2kg per sqmtr but not exceeding 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches are not exceeding 5 sqm each and thickness of RCC members exceeding 50mm including applying two coats of finishes to match with the existing surfaces at any height complete all as directed. Note:- Cost of formwork and welded mesh, bldgs height upto 12 metre shall be deemed to be included in unit rate quoted by the contractor.
Demolition of cement concrete (reinforced) and in any position not other wise specifically provided for complete all as specified and directed.
Use and waste of formwork to soffits of lintels, chajja, fins shelves including supports, overhangs etc to flat rough finished surface of concrete complete all as specified and directed.
Material and labour for TMT bars 10 mm dia and over, cut to length bent to shape required incl cranking bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia. complete all as specified.
Material and labour for RCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in chajjas, facia, shelves etc and similar work complete all as specified and directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
E/M WORKS
Taking down/ out existing aluminium/ copper point wiring (light, fan, socket or power) including fitting and fixtures such as switches, socket, call bell, lamp holder, regulator, sketch fittings etc and, making good disturbed surface of wall, ceiling floor etc complete all as specified and directed.
Taking down carefully by unscrewing from board/ outlet boxes, fitting and fixture such as switch, socket, ceiling rose, lamp holder, tube light fitting etc for reuse at or carrying to the store (to be measured only when found serviceable in all respect complete) for reuse complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 V grade multi stranded copper conductor of code red, blue and yellow for phase, black for neutral and green for earth ISI marked drawn through and including non metallic rigid PVC conduit of suitable size with accessories ISI marked concealed in wall/ceiling including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly, including provision of sunken cast iron/ pressed steel terminal box of suitable size with 3mm thick laminated sheet cover for mounting switches/sockets and regulators for one light point controlled by one switch one way complete all as specified. Note:- Cost of making good the disturbed surface plastering/ filling putty alongwith matching with the existing colour with MES approval make of distemper is deemed to be included in the quoted rate by the contractor.
All as per srl item No. 112 here-in-before but one 5 pin socket outlet 5 Amp on independent board
All as per srl item No. 112 here-in-before but one 5 pin socket outlet 5 Amp on same board
All as per srl item No. 112 here-in-before but in exisitng PVC conduit.
Material and labour for point wiring complete with 2.5 sqmm single core, PVC insulated, unsheathed FRLS cable 1100 V grade multi stranded copper conductor of code red, blue and yellow for phase, black for neutral and green for earth ISI marked drawn through and including non metallic rigid PVC conduit of suitable size with accessories ISI marked concealed in wall/ceiling including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly, for mounting switches/sockets and regulators for one 15 Amps, 3 pin socket outlet independent point controlled by one switch one way complete all as specified. Note:- Cost of making good the disturbed surface plastering/ filling putty alongwith matching with the existing colour with MES approval make of distemper is deemed to be included in the quoted rate by the contractor.
Material and labour for concealed submain wiring with two single core multi stranded PVC insulated unsheathed copper conductor of grade 1100 Volt FRLS cable of size 06 sq mm (red for phase and black for neutral) and including necessary fixing arrangement with wall/ roof in and including non-metallic rigid PVC conduit of suitable bore (as specified in SSR Part-I) and 06 sqmm multi stranded copper conductor FRLS cable PVC insulated unsheathed (green coloured) for earthing with complete accessories duly connected with earth duly complete all as specified and directed. Note :- (a) 3 runs of cable and one run of PVC conduit will be measured as one unit i.e. one RM. (b) Cost of cutting chases and making good of disturbed surface etc. shall be deemed to be included in the quoted rate.
Supply and fixing piano switch flush type single pole one way 6 Amp complete all as specified.
Supply and fixing socket outlet 2 in 1, 5 pin 6 Amp flush type complete all as specified.
Supply and fixing switch piano, flush type,16 Amp, single pole, one way complete all as specified.
Supply and fixing socket outlet 2 in 1, 3 pin 6 & 16 Amp, flush type complete all as specified.
Supply and fixing bell push, flush type, single pole, one way, 6 Amp complete all as specified and directed.
Supply and fixing of electric bell, ding dong AC single phase, 230 volts 50Hz including wooden/PVC board of suitable size, connecting & testing complete all as specified and directed.
Taking down ceiling fan sealing cable end, dismantling blades and removing fan and blades and kept in safe coustedy/ store complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose to connector of fan complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic type 5 step and connecting all as specified and directed.
Taking down old unserviceable light fitting from walls/ Ceilling complete all as specified and directed Engr-in-Charge.
Supply and fixing LED light fitting 1x20 Watt 220V, AC decorative box type with driver holder including LED light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed.
Fixing only LED light fitting including light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note:-Light fittings taken down vide Srl No. 127 here-in-before shall be reused.
Supply and fixing LED light fitting, mirror type with high output diffuser 2 feet x 10 Watt 220V AC decorative type with driver holder including LED lamp including connecting up with three core flexible copper conductor cable of suitable size compele all as specified and directed.
Supply and fixing lamp holder with and including LED retrofit lamp 9 Watts suitable for lamp holder base all as directed.
Supply and fixing ceiling rose surface type bakelite 65x50mm, two to three terminal complete all as specified and directed.
Taking out existing old unserviceable distribution box/ sheet metal enclosure off size and making good disturbed surfaces complete with same colour and specification complete all as specified and directed.
Material and labour for replacement of distribution board made out of CRCA sheet DB vertical type double door VTPN 4 way MS sheet including fixing in the wall, cutting chases grouting and necessary patch work and white wash to match with the existing including making connections all as directed containing the following:- (a) MCCB 4 Pole 100 Amps 16 KA breaking capactiy with thermal release - 01 No (incoming) (b) Bus bar 200 Amp rated made out of copper on insulated duly insulated wire adhesive tape RYB & black- 04 Nos (c) MCB SPN 40 Amp-6 Nos (d) Connection from MCCB to bus bar will be made with aluminium strip of suitable capacity as directed.
Supply and fixing in repair sheet metal enclosure for DB's when MCB's to be used of 240 Volt 8 way with factory made bus bar SPN double door complete all as specified and directed.
Supply and fixing in repair MCB single pole 6 Amps to 32 Amps, B series complete all as specified and directed.
Supply and fixing in repair MCB single pole and netural 6 to 32 Amps, C series complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.50 m below ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers, all around, top and bottom and electrode connection by using galvanized iron earth wire lead 4 mm dia (8 SWG) connected to GI earth plate electrode plate by means of bolts, nuts check nuts and washers made of galvanized iron and thimbles. galvanized iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanized iron pipe 15 mm bore light grade for protection. PCC chamber in cement concrete (1:3:6) type C-2 and RCC pit cover in M -25 complete all as shown in Electrical Plate No 3 of MES Standard Schedule of Rates (Part- I) of 2009 complete all as specified and testing on completion:- (a) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel and excavation. RCC pit cover, test point, 4mm dia galvanised iron wire from top of earth plate upto 5 m above ground level and if GI protection is less than 5 meter, no price adjustment shall be made. (b) PCC pit shall be provided at least 50 cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earthing work is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on this account. (d) Earthing work will be carried out in presence of MES representative.
Supply and laying LT cable XLPE insulated armoured heavy duty electric with aluminium conductor cable 1100 Volt grade 50 sqmm 3.5 core complete all as specified and directed
Supply and fixing exhaust fan metal body AC single phase 230/240V, 300mm sweep with louvers including nuts, bolts, fixing arrangement and making hole in wall and making good the surface complete all as directed.
Supply and fixing in repair GI pipe bracket made out of GI pipe 40mm bore light grade, bent to shape 1.5 metre long, MS clamp made out of MS flat iron of size 40x4mm thick with nuts and bolt, washer complete including dismantling the existing GI pipe bracket and drilling of hole for nut and bolt etc all as specified and directed.
Supply and fixing new generation energy saving 45 Watt LED building security street light IP-65 lumanaires with long life versatile pressure die-cast aluminium housing with high power LED as lighting source and lens embeded PC cover road way luminaire complete accessories connecting up with three core flexible copper conductor cable all as specified and directed.
Material and labour for sand cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed. Note:- Punned down thickness shall be measured for payment.
Material and labour for GI tubing, light grade, 50mm bore, for cable protection fixed with pole/ under road/ along the wall with necessary clamps all as specified.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for laying of cable in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete as all as specified and directed.
Supply and laying bricks common burnt sub class 'B,' old size, for protection of cable laid in trenches for under ground cable all as specified.
Harbhajan electric co
GORAYA AND CO
yash paul gupta
ESS KAY BUILDER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .