Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.7 L+₹54,337 (1.42%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹39.3 L+₹1.1 L (2.87%)Rejected-Finance | L3 | Rejected-Finance Quoted amount is more than L1 | |
| 4 | L4₹48.4 L+₹10.2 L (26.7%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L4 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Nov 2023, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/MAINT OF CI/GI PIPE LINE AND CONNECTED WORKS AT NAMKUM/KHOJATOLI AND REPAIR/CLEANING OF WATER SUPPLY OH WATER TANK, SEMI UG SUMP AND CERTAIN CONNECTED WORKS AT NAMKUM, KHOJATOLI LPH AREA AND 1 (I) R O FLT UNDER GE RANCHI
2023_MES_623525_1
8400/1200/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat a (ii)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹90,000
Yes
24 Jan 2024
16 Oct 2023
13 Nov 2023
17 Oct 2023
11 Nov 2023
29 Oct 2023
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in soft / loose soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Taking up or taking down GI tubing and connections including cleaning for refixing or removal to store for the following sizes, complete all as specified and directed
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Relaying/refixing only GI tubes any grade in trenches materials obtained from Item No.4 here-in-before after cleaning or returning the old screw threads with replacement of unsv fittings and fixtures for following size of complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches complete all as specified and as directed of following sizes. All GI fittings like union, socket, elbow, reducer, tee, bend, etc of any size required for laying and fixing the GI pipe are deemed to be included in the rate quoted.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
S & F in replacement of gun metal gate valve with iron wheel head screwed both ends ISI marked fixed to GI pipe complete all as specified and as directed of following sizes :-
15 mm dia.
20 mm dia.
25 mm dia.
40 mm dia.
50 mm dia.
S & F Cast iron sluice valve with stainless steel spindle and cast iron hand wheel complying with IS:14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one of the following bore sizes, complete all as specified and directed.
150 mm dia
100 mm dia
80 mm dia
S & F in replacement of gun metal Non return valve Horizontal/vertical type screwed both ends ISI marked fixed to GI pipe complete all as specified and as directed of following sizes, complete all as specified and directed.
20 mm dia
25 mm dia
40 mm dia.
50 mm dia.
Supply and Fixing cast iron body and brass gate heavy duty non return valve ISI marked ( NRV) both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one of the following bore sizes complete all as specified and directed.
225 to 250 mm dia
200 mm dia
150mm dia
100 mm dia
Cutting Cast iron pipes and reducing to required length before laying of following sizes comple all as specified and directed
300 to 350 mm dia
225 to 250mm dia
200 mm dia
150mm dia
M&L Rubber gasket tyton joint complete for following bore sizes of existing pipe complete all as specified and directed.
80mm dia
100mm dia
150mm dia
225 to 250mm dia
300mm dia
350mm dia
Dismantling of existing /damaged masonary valve chamber of any size complete all as specified and directed
M&L for construction of Brick Masonry Valve Pit, one Brick thick wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement including one lock and two keys and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit of size 600 x 600 x 600 mm (Internal Dimension) complete all as specified and as directed.
Description as S.No 14 above but of size 1050 x 1050 x 1200 mm (Internal Dimension)
M & L Run Lead joint in spigot and socket pipes and fittings of following bore sizes of pipe including burning out of old lead and necessary caulking the spun yarn as required complete all as specified and directed.
300mm dia
150mm dia
100 mm dia
80mm Dia
M&L Cement concrete in foundations filling, and mass concrete type B-2 1:2:4 (40mm graded aggregate) complete all as specified and directed
S&F in repairs valve pit chamber cover of MS Sheet cover 3mm thick layer with handle and locking arrangement including painting with two coats of synthtic enamelled paint over a coat of red oxide primer, complete all as specified and directed .
Supply and fixing cast iron foot valve, ISI marked both end flanged with nut bolt washers and rubber gasket confirming IS 4038, installation, testing of following sizes complete all as directed and specified. All arrangements including removal of water from sump by using pump (if required) is to be arranged by contractor and cost is deemed to be included in the rate quoted.
100 mm dia
150 mm dia.
200 mm dia
S&F Air relese valve suitable of 150mm dia CI pipe flange end type and including jointing materials rubber gasket suitable size nut bolts , clamp and washer etc including removing old unsv one complete all as specified and directed
S&F Bends (any type radius and angle) tapers any type, (straight bend increasing, decreasiing or double socket etc) Tee pieces single branch, Y junction, double branch cross (all sockets or socket and spigot collar and plugs upto 350mm bore pipe complete all as specifed and directed
M & L for connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth, CI Bends tapers, Tees, pieces (Single or double branch) any Type and angle / radius and straight connecting pieces for CI Pipe upto 350 mm bore complete all as specified and as directed.
Taking up or taking down CI/DI pipes of sizes of following sizes and connections including cleaning for refixing or removal to store complete all as specified and directed.
100 mm dia
150mm dia
200mm dia
225/250 mm dia
Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes of following dia with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified and directed. Note : Excavation and earth work shall be measured and paid separately.
100mm dia
150mm dia
200mm dia
225/250mm dia
M&L 2 x bolted flange joints with rubber gasket or fibre board 3mm thick including nuts, bolts, washers etc complete for CI pipe/fittings/specials all as specified and directed for the 200-350mm dia pipe.
S& F spun yarn for maint of pipe line and connected works complete all as specified and directed
S&F lead wool for maintenance of pipeline and connected works complete all as specified and directed
S&F teflon tape (Threaded sol) Nylon kohinoor for maintenance of pipeline and connected works complete as specifed and directed
S&F adhesive as per sample (M-Seal) for maiintenance of pipeline and connected works, complete all as specifed and directed
M & L ttending the emergent repairs to leakage/ damage/ blockage GI pipe of size 100/150 mm including carrying out repairs etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting out GI pipe at both ends and jointing with new fittings, accessories such as union, sockets, reducer, mechnaical joint, nipple, Tee, Tee reducer etc complete all as specified and as directed. (i) Rate inclusive of jointing & earth work. (ii) GI fittings will be paid separately in respective items.
Supply only CI mechanical joints of followig dia of pipe
300 to 350 mm dia
225 to 250 mm dia
200 mm dia
150mm dia
Supply only CI nipple of following dia of pipe 1 feet long
300 to 350 mm dia
225 to 250mm dia
200 mm dia
150mm dia
Supply only CI socket of following dia of pipe
300 to 350 mm dia
225 to 250mm dia
200 mm dia
150mm dia
M&L burning out unsv/ leakage lead joint in position, including removing old lead and necessary excavation of soils, returning, filling and removal of accumulated water by using pump of following sizes complete all as specified and directed by Engr-in-charge. Note : (i) Rate inclusive of earth work. (ii) Lead joint will be paid separetly under respective items.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
225 to 250mm dia
300 to 300mm dia
M&L Run Lead joint in spigot and socket pipes and fittings of following dia of pipes including necessary chaulking the spun yarn as required complete all as specified and directed.
80mm dia
100mm dia
150mm dia
200 mm dia
225 to 250mm dia
300 to 350 mm dia
M&L attending the emergent repairs to leakage/ damage/ blockage CI /DI pipe of following sizes including carrying out repairs etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting out CI pipe at both ends and jointing with new fittings/CI pipe, accessories complete all as specified and as directed by Engr-in-charge. (i) Rate inclusive of jointing & earth work. (ii) fittings will be paid separately in respective items.
100/150 mm dia
200/225mm dia
300/350 mm dia
M&L attending the emergent repairs to leakage/ damage/ blockage GI pipe of size 15 mm/20 mm/25 mm dia including carrying out repairs etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting out GI pipe at both ends and jointing with new fittings, accessories such as union, sockets, reducer, nipple, Tee, Tee reducer etc complete all as specified and as directed by Engr-in-charge. (i) Rate inclusive of jointing & earth work. (ii) GI fittings will be paid separately in respective items.
M & L for attending the emergent repairs to leakage/ damage/ blockage GI pipe of size 40/50/80 mm dia including carrying out repairs etc as required to make the system in order / functional and necessary excavation ,returning , filling of soils and removal of water by using pump, cutting out GI pipe at both ends and jointing with new fittings, accessories such as union, sockets, reducer, nipple, Tee, Tee reducer etc complete all as specified and as directed by Engr-in-charge. (i) Rate inclusive of jointing & earth work. (ii) GI fittings will be paid separately in respective items.
Attending complaints logded by the occupants daily on working hours of external water supply 9 am to 5 pm at Namkum and Khojatoli area (Team of one plumber and one helper on daily basis) and rectification of the fault will be done as per the complaint lodged by the user like no water supply to be checked, leakage of union, socket, bend, lead Joint etc in all type of water supply pipe lines, as reqd at site and rectification done by contractor plumber by fixing of new fittings and fixtures, complete all as specified and directed. Note :- (a) Contractor/ his rep has to collect the complaints from complaint cell on daily basis. (b) The complaint is to be attended and rectified on the same day i.e with in 24 hours. (c) Non attendence of complaints within the stipulated time frame i.e 24 hours shall invite penalty of 1000 per complaint and the penal amount shall be recovered from the RAR/ Final bill. (d) Material/ fittings required shall be measured and paid separately as supply only under the respective items.
Supply only GI Elbow 15mm dia
Supply only GI Elbow 20mm dia
Supply only GI Elbow 25mm dia
Supply only GI Elbow 40mm dia
Supply only GI Elbow 50mm dia
Supply only GI Elbow 80mm dia
Supply only GI union 15mm dia
Supply only GI union 20mm dia
Supply only GI union 25mm dia
Supply only GI union 40mm dia
Supply only GI union 50mm dia
Supply only GI union 80mm dia
Supply only GI Tee 15 mmx15mmx15mm dia
Supply only GI Tee 20 mmx15 mmx15mm dia
Supply only GI Tee 20 mmx20 mmx15mm dia
Supply only GI Tee 20 mmx20 mmx20mm dia
Supply only GI Tee 25 mmx25mmx25mm dia
Supply only GI Tee 25 mmx25 mmx20mm dia
Supply only GI Tee 25 mmx20mmx20mm dia
Supply only GI Tee 40 mmx40mmx40mm dia
Supply only GI Tee 40 mmx40mmx25mm dia
Supply only GI Tee 40 mmx25mmx25mm dia
Supply only GI Tee 50 mmx50mmx50mm dia
Supply only GI Tee 50 mmx40mmx40mm dia
Supply only GI Tee 50 mmx25mmx25mm dia
Supply only GI socket 15mm dia.
Supply only GI socket 20mm dia.
Supply only GI socket 25mm dia.
Supply only GI socket 40mm dia.
Supply only GI socket 50mm dia.
Supply only GI socket 80mm dia.
Supply only GI nipple 15mm dia, 50mm long.
Supply only GI nipple 15mm dia, 100mm long.
Supply only GI nipple 15mm dia, 150mm long.
Supply only GI nipple 20mm dia, 50mm long.
Supply only GI nipple 20mm dia, 100mm long.
Supply only GI nipple 20mm dia, 150mm long.
Supply only GI nipple 25mm dia, 50 mm long.
Supply only GI nipple 25mm dia, 100mm long.
Supply only GI nipple 25mm dia, 150mm long.
Supply only GI nipple 40mm dia, 50mm long.
Supply only GI nipple 40mm dia, 100mm long.
Supply only GI nipple 40mm dia, 150mm long.
Supply only GI nipple 50mm dia, 50mm long.
Supply only GI nipple 50mm dia, 100mm long.
Supply only GI nipple 50mm dia, 150mm long.
Supply only GI Reducer 80mm x 50mm dia
Supply only GI Reducer 80mm x 40mm dia
Supply only GI Reducer 50mm x 40mm dia
Supply only GI Reducer 50mm x 25mm dia
Supply only GI Reducer 50mm x 20mm dia
Supply only GI Reducer 40mm x 25mm dia
Supply only GI Reducer 40mm x 20mm dia
Supply only GI Reducer 40mm x15mm dia
Supply only GI Reducer 25mm x 20mm dia
Supply only GI Reducer 25mm x 15mm dia
Supply only GI Reducer 20mm x 15mm dia
Supply,laying testing after commissioning the following pieces of DI/GI pipe havy duty with fittings including removing old one for fixing at pump house Namkum :- (i) 200mm DI/GI double flanged pipe - 02 RM - 01Pc, 6.4RM - 1 Pc, 5.10 RM - 1 Pc, 5.6 RM - 1 Pc (ii) 200mm 90 digree bend double flanged - 03 Nos (iii) 200mm NRV flanged - 01 No (iv) Necessary PCC 1:3:6 incl brick work (v) nut bolt of suitable size incl heavy duty gasket Note :- All other fittings (Tee, bend, elbow, flange) and fixtures incl tools and plants, dismantling old PCC, welding work and all other accessories required to make functional the said suction pipe are included in quoted rate.
M&L seven stage cleaning and sterilization of inside the RCC/Underground/semi underground/Over head tanks/ Sedimentation / clear water sumps of following capacity through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: Any E-in-C branch approved ageny :- (a). First Stage is to drain out the water by using exit valve or our own high capacity dewatering system or by own arrangement approved by Engr -in -Charge. (b). Second stage is cleaning all the algae formation and removing the accumulated silt from bottom bed and side walls by brushing with nylon brush or scrubbing the walls of the tanks or removing other sticky or foreign materials from adhering surfaces and washing inside surfaces with TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company. (c). Third stage is fresh water cleaning by high speed jet pump with a pressure of 5 psi (d). Fourth stage and first bacteria screening and degermification by using TERBAC-G5/ Inohor-5/NB-10 a Laboratory certified branded halogen compound. (e). Fifth stage is cleaning the floor of water tank by heavy duty industrial vacuum cleaner. (f) . Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65 . NOTE:- (i) COMPANY WILL SUBMIT TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69 BEFORE CLEANING (ii) PAINTINGS OF INFORMATION BOARD - AFTER COMPLETION OF CLEANING OF EVERY TANK WITH TWO COATS SYNTHETIC ENAMEL PAINT (1ST GRADE QUALITY) (A) INCLUDING WRITING LETTERS & FIGURES BOLDLY AND SOLIDLY (B) TANK CLEANED ON _____( DATE OF CLEANING) & (C) CA NUMBER (D) NAME OF CONTRACTOR+B200
(E) HAVING A HEIGHT OF ALL LETTERS 10 CM WITH OBLITERATING THE OLD ONE AND (F) PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. (iii) ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (iv) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID ENTERING SCALES AND THE SAME SHALL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION . (v) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. (vi) ARRANGEMENET OF WATER REQUIRED DURING THE CLEANING WILL BE RESPONSIBILITY OF THE CONTRACTOR of following capacities:-
All as per ser item No 98 above but for of inside UG sump reservoir capacity of 150000 - 200000 gallons .
All as per ser item No 98 above but for over inside UG Sump/Semi UG sump reservoir of capacity 100000 gallons
All as per ser item No 98 above but for of inside UG/Semi UG sump reservoir capacity 50000 gallons . .
All as per ser item No 98 above but for of inside UG/Semi UG Sump reservoir capacity of 25000 gallons
All as per ser item No 98 above but for of inside UG/Semi UG Sump of capacity around 10000 gallans .
All as per ser item No 98 above but for of inside overhead reservoir capacity 200000 gallons .
All as per ser item No 98 above but for of inside overhead reservoir capacity 100000 gallons .
All as per ser item No 98 above but for of inside overhead reservoir capacity 40000 - 50000 gallons.
All as per ser item No 98 above but for of inside overhead reservoir of capacity 25000 gallons .
All as per ser item No 98 above but for of inside overhead reservoir capacity 20000 - 24999 gallons
All as per ser item No 98 above but for of inside overhead reservoir capacity 10000 gallons . Note of item No 98 to 109 :- The contractor will be responsible for removal of any honeycomb /Beehive giant/hornet comb on the surface of OHT, removal before cleaning of the tank and the same will be included in above quoted rates. Contractor shall also be responsible for cleaning the vegetation of surrounding area to distance of minimum 3 mtr for UG Sump/OHT and removing the waste material not exceeding 50 Mtr within the same quoted rates.
Dewatering & Cleaning of Main water Receiving tank / Sump of capacity 25000 gallons by bailing out stagnant water and removing all fungus muds and sludge, de-scaling vegetation on the inside of fire tank/open well and white washing (Two Coat) and one coat of cement base paint etc including Cleaning the surroundings area of the open well to a distance of 3 mtrs circumstance including cutting of grass digging out roots, filling holes and levelling around and removing waste materials to a distance not exceeding 50 Mtrs complete all as directed.
Dismantling old unserviceable water level indicator and M&L for mechanical water level indicator making functinal by replacing the sheet board, steel wire rope, float assembly , pullys including GI wire fixed at both side of board with approved colour of synthetic enamelled paint and writing letters/numbers all as directed.
Repair & Fixing of 48 W LED aviation obstruction light on OH tank with all necessary connected items complete all as specified and directed.
M&L Earthing complete with galvanized cast iron earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.50 mtr below normal ground level connected to galvanized iron lead using 4 mm dia as earthing lead by means of nuts and bolts check nuts and washers of galvanized iron or steel all as shown in electrical plate no 3 and connected to earthing test point all as specified or indicated including testing on completion.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated places and down conductors of 25 x 3 mm aluminium strip above ground along outer surface of OHT all as directed.
M&L for air termination rod made of copper with 12mm rod 300mm long complete set fitting on the top of OHT all as per Engineer-in-Charge
Supply only Hi strength granular chlorination chemical based with CIAS (Corrosion inhibitor & Anti scalant) to be ratified by E-inC's Branch , Dry, Free flowing consistent white granules (or powder) and without hard lumps or impurities should not induce substances beyond acceptable limit as given in IS:10500:2012 in treated and disinfectant water, high strength granular chlorine having 65 % - 70 % chlorine content by mass packed in 45 Kgs non returnable PVC sealed container, 5-10% moisture content , upto 4% calcium hydroxide upto 15% sodium chloride suitable for treatment of drinking water and swimming pool ( Much more stable than chlorine gas, bleaching power and sodium hypochlorite) all as specified and directed.
Cutting unaxious green growth and grass by manual labour or by machine at all E&M water supply Installation premishes and along the boundary fencing and removing rubbish from the site of work where decided not exceeding 100m from the starting point, the green growth shall be clean once in every three month and the measurement shall be taken every time independently for the excuted qty each time
M&L for spray painting to exposed surfaces of cast iron pipe line of any size with two coats of synthetic enamel dust and weather proof paint of approved make (as per existing colour i.e. for inlet pipe- Blue colour, for outlet - Green colour, for overflow - Yellow colour, for drain out pipe - Black colour) over a coat of red oxide primer including preparation of old surfaces of pipes, by scrapping or complete removal of rusting to the pipes , filling cavities with filler, complete all as specified and as directed.
Ranchi Construction Company
AASHIRWAD ENTERPRISES
BHARATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .