Provision of CCTV System at Manned Non-Interlocked LC Gates on Bhusawal Division of Central Railway
BSL-N-SNT-31-2025-26~CR
BSL-N-SNT-31-2025-26
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹3.1 L
1 Jan 2026
9 Dec 2025
18 Dec 2025
A-Provision of CCTV System at Manned Non-Interlocked Gates on
Supply, Installation, Testing & commissioning of Full HD Resolution Fixed Box type IP Colour Camera with varifocal lenses along with housing and mount with all accessories as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection by RDSO.
Supply and installation of of 32 channel NVR as per specs No. 10.2 of RDSO specs No. RDSO/SPN/TC/65/2021 Version:6 or latest including 1 TB Surveillance HDD. With two slot of HDD supporting 10TB
Supply of 2000 GB HDD Hard disk drive Brand: TOSHIBA (Detailed Description/Specification as per annexure.
Supply, Installation, Testing and commissioning of On-Line UPS of 5 KVA capacity with isolation transformer suitable for single phase as per Technical Specification in Chapter-III of the Tender Document. Inspection by consignee.
Supply and Installation of 6U Rack outdoor cabinet IP64 enclosure. (Inspection by Consignee)
Wireless trans-receiver for remote location CCTV as per technical specifications in chapter III of Tender document. Inspection by RITES
Supply, Installation, Testing & Commissioning of PC Workstation hardware as per clause no. 11.0 of RDSO Spec RDSO/SPN/TC/65/2021 Revision 6.0 or latest for Viewing, Monitoring and System Management with digital keyboard and loaded with Graphic User Interface Client Software Features per clause no. 18.2.0 of RDSO Spec RDSO/SPN/TC/65/ 2021 Revision 6.0 or with latest amendment. Software licenses conditions as per RDSO spec Clause 20.0 of RDSO Spec RDSO/SPN/TC/65/2021 Revision 6.0 or latest. (Inspection by RDSO)
Luminous Solar Combo for Home, Office & Shops | NXG+ 1150 Inverter, LPT12150H 150Ah Battery & 170W Polycrystalline Solar Panel | Off-Grid Power Solution
Supply, Installation, Testing & Commissioning of Field Switch 8 port as per RDSO Specification RDSO/SPN/TC/ 65/2021 Rev.6.0 or with latest amendment. (Inspection by RDSO)
Supply of 6 Mtrs Octagonal Pole for CCTV Camera mounting with accessories
CC Foundation and erection of poles for CCTV Camera at location with non- availability of structure/building for CCTV cameras.
CAT-6, UTP-Cable, CAT-6 Cable shall be compliant with latest EIA/TIA-568-C.2 standard for CAT 6 cable with. Brand: Digisol, Finolex, Molex, AMP, Nortal, Lucent or better
Laying of STP CAT 6 /OFC/ power cables in conduit as per specification, including laying in conduit pipe/ duct (All laying materials including coduit will be supplied by the contractor). (Inspection by Consignee)
Supply of power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable as peras per RDSO Specification RDSO/SPN/TC/65/2021 Rev.6.0 or with latest amendment suitable for railway electrification area shall be of reputed make like Delton, LAPP, Finolex. (Inspection by RDSO)
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.
Splicing and termination of OFC & FDMS & Joint (48Fibers) as per specifications and testing . This include all relevant type of materials for splicing. Each fiber shall be properly marked with necessary ferrules/tags
Supply of fiber optic patching cord LC-FC/FC-FC/LC-SC as per site requirement. (Inspection by RITES)
Supply, installation, testing & commissioning of 24 port rack mountable FMS/LIU of 24fiber (12x2 fiber ) with connector & connecting/splicing the OFC (Pigtails and other miscellenious material required for the work shall be supplied by the contractor). (Inspection by Consignee)
Supply, preparation, splicing and installation of straight joint for 48 fibers along with 19 enclosures with heat shrinkable splice protection sleeve as per TEC/GR/TX/OJC-002/03/APR-2010 or latest. Splice losses in no case should be more than 0.1 dB. Inspection -Supply by Rites Execution by Consignee.
Supply CAT 6 Patch cord 5 meter. Make: D-Link, Digisol, R&M. (Inspection by Consignee)
Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper 21 bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 No 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx.
Installation of unit earth as per RDSO/SPN/197/ver I or latest, to construct earthing of </= 1 Ohm consisting of a. digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and all other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the relay room, Exothermic weld materials and tools & fixtures for the welding Copper tapes and Electrodes etc shall be arranged by the contractor.
"Cutting of all types of Roads/ platforms (except concrete type) for trenching and 23 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. (Inspection by Consignee) "
Cutting of the platform with tile / rock cutting machine or manually to 30 cm depth and 12cm width approximately (including cutting of tiles neatly provided) by removing slabs / tiles if 24 any and filling the trench with river sand and replacing the top surface with smooth finished shaped slabs after putting a layer of cement mortar to the surrounding level as per instructions of Site In charge at site. All the materials except pipes / cables are to be arranged by the contractor at sit, the debris is to be cleared from platform to outside station. (Inspection by Consignee)
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer 25 of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 26 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and 27 accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources. (Inspection by Consignee)
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/Road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & 28 instructions of site engineer. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
"Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for Other location with minimum depth reckoned from the ground level. The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal 29 Boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING beyond of 150mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative."
Laying of HDPE duct in trench and its protective work as per direction of site engineer. (Inspection by Consignee)
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4.
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by Consignee)
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc. (Inspection by Consignee)
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. Inspection by consignee.
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends. The work should be executed as per instructions of railway engineer and as per guidelines in chapter IV of tender document. Inspection by consignee
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.
Supply and fixing of Cable Route Marker Concrete.Drawings to be approved by Consignee. (Inspection by Consignee)
Supply of HDPE Pipe 110 mm Diameter,PE63, Class PN6, with confirming to IS4984 with ISI marked (or) Latest.Type test report from Central Govt./state Govt/ NABL / ILAC to be submitted at the time of supply. Inspection By Consignee.
Supply and installation of gateway with sim port to establish IP-Sec VPN tunneling with central server supplied. as per specifications
Supply, Installation, Testing & Commissioning of Professional Large Format LED Video 40 Display Unit, 55" (inches) or larger, Full HD 1920 x1080, Brightness: 350cd/m, contrast ratio 1100:1, HDMI & DVI port, Including wall mount kit.as per clause 9.0 of RDSO Spec RDSO/SPN/TC/65/2021 Revision 6.0 or with latest amendment. (Inspection by RDSO) Number-
Data connectivity Up to 100 Mbps via air fiber/ fiber /5G network.
B-AMC for CCTV System at Manned Non-Interlocked Gates on Bhusawal
Annual Maintenance Contract(AMC) for 05 (Five) Years after completion of 3 Years warranty period for the Schedule item No. 1, 2, 4, 6, 7, 8 & 9.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .