Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.9 L+₹2.3 L (7.70%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹32.5 L+₹2.9 L (9.92%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.1 L+₹5.5 L (18.7%)Rejected-Finance 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.2 L+₹5.6 L (19.0%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹87,373
Closing Date
18 Jan 2024, 6:00 pmClosed
GE (AF) Bhisiana
GE (AF) Bhisiana PIN-151201
As per BOQ/ Price Schedule
2023_MES_633747_1
GE/BHI/CAP-02/2023-24
Open Tender
Civil Works
Item Rate
150 days
GE (AF) Bhisiana
As per NIT/ Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Bhisiana
₹87,373
5 Feb 2024
20 Dec 2023
20 Jan 2024
20 Dec 2023
18 Jan 2024
4 Jan 2024
20 Dec 2023 - 2 Jan 2024
Amount
BUILDING WORKS (INTERNAL SERVICES)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed by Engineer in Charge.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. including 15mm thick screed bed in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer in Charge.
M&L for joint free dark shade/double charged vitrified tiles 9 to 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified and directed by Engineer in Charge.
M&L for joint free dark shade/double charged vitrified tiles 9 to 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:3 to receive vertical tiles complete all as specified and directed by Engineer in Charge.
M/L for 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base complete all as specified and directed by Engineer in Charge.
M&L for Glazed ceramic coloured tiles in vertical surface 350x250x7mm / 450x300x7mm thick including 10mm thick cement plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engineer in Charge.
Dismantling Stone slabs and tiles of any description or thickness laid bedded & pointed in any mortar in floors/walls, aprons incl removing from site complete all as specified and directed by Engineer in Charge.
M&L for fixing of granite 18-20mm thick of any type ( table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 incl pointing in white cement including making hole for gas pipe and necessary cutting in granite for fixing sink complete all as specified and directed by Engineer in Charge.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer in Charge.
Demolition of concrete above ground floor for sunken portion exc 15 cm thick and removing the rubbish out side MD land complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick rendering in cement mortar (1:3) as in sunken portion mixed with water proofing compound 3% by weight of cement, finishing surfaces even & smooth without using extra cement complete all as specified and as directed. (Note :- Water proofing compound shall be measured and paid seperately) complete all as specified and directed by Engineer in Charge)
Supplying only integral water proofing compound, ISI marked complete all as specified and directed by Engineer in Charge.
M&L for bitumen blown any grade, applied hot, two coats to concrete surfaces at the rate of 1.5 Kg per Sqm per coat complete all as specified and directed by Engineer in Charge.
M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm in sunken area complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in filling of sunken and mass concrete complete all as specified and as directed.
M&L for 50mm dia GI spout pipe fixed in sunken floors by means of cutting holes in wall bedded in cement mortar and making good the disturbed portion of wall complete all as specified and directed.
Taking down cement plaster on brick or stone masonry Including raking out joints, hacking for key scrubbing down with water etc incl removing from site complete all as specified and as directed by Engineer in Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed by Engr-in-Charge.
M&L for 5 mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and fair (without using extra cement) complete all as specified and directed by Engineer in Charge.
M&L for Applying three coat of white wash over and after preparation of new plastered surfaces of celing complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment and applying three coat of white wash on celing complete all as specified and directed by Engineer in Charge.
M&L for Applying two coat of white wash over and after preparation of new plastered surfaces of wall complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment of wall and applying two coat of white wash complete all as specified and directed by Engineer in Charge.
M&L for 1-2 mm thick wall care putty on internal surface of wall area complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surface of internal wall surface and applying Two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour incl primer complete, as per manufacturer's specification complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment of internal wall surface of wall and applying Two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour incl primer complete, as per manufacturer's specification complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surface of external wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment painted surfaces of external wall with scrapping, wire brushing, washing with water preparation of old plastered surfaces of external wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer in Charge.
M&L Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer in Charge.
M&L for 15 mm dia tubes medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer in Charge.
Refixing 20 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) complete all as specified and directed by Engineer in Charge.
M&L for 20 mm dia tubes, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
M&L Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer in Charge.
Refixing 25 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc.) complete all as specified and directed by Engineer in Charge.
M&L for 25 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall complete all as specified and directed by Engineer in Charge.
Dismantling water tanks exc 500 ltr and nexc 1000 ltr and removing to store complete all as specified and directed by Engineer in Charge.
S&F for Rotational moulded polyethylene water storage tanks triple layer 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer in Charge.
S&F Gun metal gate valves 20mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engineer in Charge.
S&F Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair china wash down water closet padestal pattern white excluding flush and fix to position, including seat cover and connection to drain etc complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 'P’ trap 110mm dia complete all as specified and directed by Engineer in Charge.
S&F in repairs Vitreous China wash basin, white , flat back,size 550x400mm including pedestal white incl 32mm brass CP coupling to basins etc, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with waste pipe complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) floor trap (Medium duty), plain with SS grating with hole/without hole including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) floor trap (Medium duty), plain with SS grating without hole including jointed with solvent cement of 110 mm outlet dia complete all as specified and directed by Engineer in Charge.
S&F in repair flush pipe of Polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed by Engineer in Charge.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer in Charge.
S&F 15mm dia brass chromium plated centre hole wash hand basin mixer with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm bore Angle cock, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm bore 2 way Angle cock, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F in repairs 15mm dia Bib taps, long body, Chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repairs 15 mm bore Stop Valve chromium plated with long shank and cup (concealed type) ,cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed by Engineer in Charge.
S&F CP Health Faucet with 1.20 mtr metalic expandable tube & hook complete all as specified and directed by Engineer in Charge.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer in Charge.
S&F in repairs CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer in Charge.
S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints,including fixing to steel pipe or union Complete.
S&F Stainless Steel Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) incl removal of debries complete all as specified and directed by Engineer in Charge.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection complete all as specified and directed by Engineer in Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
M&L for reinforced cement concrete (nominal mix) 1:2 :4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately complete all as specified and directed by Engineer in Charge.
S&F TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer in Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes (Medium duty) single socketed in any length with rubber ring joints fixed to walls/floor with and including clamps, nut bolts including dismantling of old outlet pipe etc. complete all as specified and directed by Engineer in Charge.
S & F 75 mm bore PVC (SWR) pipes (Medium duty) single socketed in any length with rubber ring joints fixed to walls/floor with and including clamps, nut bolts including dismantling of old outlet pipe etc. complete all as specified and directed by Engineer in Charge.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer in Charge.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F PVC (SWR) junction single Tee/'Y' junction equal or unequal 110 mm dia complete all as specified and ditected.
S&F PVC (SWR) junction single Tee/'Y' junction equal or unequal 75 mm dia complete all as specified and ditected.
S & F in repair 32 mm dia PVC waste pipe for WHB 90 cm long with union, complete all as specified and directed. equivalent) complete all as specified and directed by Engineer in Charge.
Taking down Chowkhats or frames with shutter not exc 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer in Charge.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, supply & fixing in opening as per specification & drawing complete all as specified and directed by Engineer in Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as shown in SSR Part – II 2010 and as directed by GE/Engineer-in-Charge.
S&F for 100mm size stainless steel butt hinges all as specified
S&F for 100mm size stainless steel handles all as specified and directed
s&F for 150mm long stainless steel tower bolt all as specified and directed.
Taking down Aluminium Chowkhats or frames with shutter not exc 1.50 Sqm each (without taking off shutters from the frames including all accessories)
Taking down Aluminium chowkats & shutters without taking off shutters from the frame, size of opening exc. 1.50 sqm but not exc 4 Sqm each complete all as specified and as directed.
S & F for Anodised aluminium frame for doors, windows ventilators (Powder Coated) with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, mortice locks anodised aluminum snap beading screws etc. complete all as specified
S&F Powder coated Anodised aluminium sliding window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
M & L sheet glass ordinary quality 5.5mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed by Engr-in-Charge.
M&L for solar control film 25 micron reflective type sticked to glass panes as per instruction of manufacturer complete all as specified and directed by Engineer in Charge.
S&F 12mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminations, fixed in aliminium doors complete all as specified & directed.
Supply and fixing Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple complete all as specified and directed by Engineer in Charge.
S&F Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc. complete all as specified and as directed.
S&F Aluminium (Die Cast body) Door closer hydraulically regulated designation No 1 universal type suitable for door shutters up to 1000mm in width and of weight between 36 to 60 kg and fixed complete all as specified & directed.
Providing precast cement concrete louvres and jallies 25mm thick type B0 (1:2:4 using 12.5mm graded aggregate), (measured solid), including all mouldings complete all as specified and directed.
S&F in repair 20 mm dia stainless steel polished 204 grade drapery rod/curtain rod 1 to 2mm thick with finals decorative, including fixing of brackets and both ends decorative nobs, complete all as speccified and directed as per approved sample by Engr-in-Charge.
Dismantling brick tiles or terracing tiles single layers on roof complete all as specified and directed
Demolition of mud in roofs, any thickness including plastering/pcc padding and leaping (where full thickness removed or only a part thereof) complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including dismantling existing membrane complete all as specified and as directed.
Brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed.
M & L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor, roof etc complete all as specified
Demolition of cement concrete in any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer imn Charge.
M&l for providing cement concrete type B-0 (1:2:4) 12.5 mm graded stone aggregate for providing slope, roof kerbs or mud stops rounded or chamfered edges all as directed by engr-in charge
M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions complete all as specified. (Note - Water proofing compound shall be measured and paid separately).
Supplying only liquid water proofing compound, ISI marked complete all as specified and as directed.
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, complete all as per manufacturer's instructions all as specified and directed by Engineer-in-Charge.
S&F for Rolled mild steel in Rolled sections as in main and cross beams, hip and jack rafters: purlins where connected to common rafters and running rails and guides for sliding doors: fixed with angle cleats or other connecting plate complete all as specified and directed.
S&F for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and as directed.
Dismantling wall & ceiling board any type, any thickness including cover fillets complete all as specified & directed.
M&L for Non asbestos fibre cement boards 595x595x4mm thick fixed in ceiling Aluminium frame work with screws complete all as specfied.
S&F Anodised aluminium snap grid frame work of grid 600x600mm for false ceiling all as specified
S&F Factory made PVC cupboard sides, top & bottom frame (Each side measured Seperately ) , 30mm thick (hollow) with a wall thickness of 5mm made out of extruded 5mm thick plain/printed / prelam PVC sheet reinforced with 19mm x 19mm MS square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners and jointed with two numbers 150mm long brackets of 10mm x 10mm square tubes and cupboard frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using PVC fasteners. A minimum of 4 nos of screw to be provided for each vertical member and minimum of 2 nos of srew to be provided horizontal member etc complete as per manufacter's instructions and all as specified and directed .Note :- Making good the disturbed side plastering and Painting with existing colour (Distemper/OBD ) included in the item
S&F Factory made PVC cupboard shutter of 30 mm thick consisting of frame made out of MS tubes of 19 gauge thickness and size 19mm x 19mm covered with panneling of 5mm plain plus 5mm thick prelaminated PVC sheet fitted in the MS frame and sealed to the front stiles and rails which should having 20mm x15mm wide PVC biding and attached to back stiles and rails (which should have a 5mm 45 degree bend portion as beding) and decorative PVC beding is used on the front side of pannel externally impart perfect finish to the shutter and joint together with solvent cement adhesive complete all as specified and directed.
S&F Factory made PVC drawer of required size (Each side measured Seperately ) constructed by joining two nos 5mm thick plain PVC sheet at the sides and bottom joint together with solvent cement adhesive complete all as specified and directed.
S&F Factory made PVC centre partition shelfs of 25mm thickness consisting of MS Frame made out of MS tubeof 19 guage thickness and size of 15x15mm inserted all around the hollow profile section and insert 15mmx15mm MS tube in the centre of this section and liped with 10mm (5mm x2 ) thick plain PVC sheet at the top and bottom and 20mm wide and 15mm thick on sides using solvent cement adhesive complete all as specified and directed .
S&F 5 mm thick termite proof, water proof and fire retardant laminated PVC sheet jointed together at front side of Cupboard drawer frame using solvent cement adhesive complete all as specified and directed by Engr-in-charge.
S&F 5mm thick termite proof, water proof and fire retartant plain PVC sheet jointed together & fixed on back side of Cupboard frame using solvent cement adhesive complete all as specified and directed by Engr-in-charge.
S&F 30 to 50mm wide and 5 mm thick laminated PVC leeping in front of the cupboard to be edge bonded using on the edges etc complete all as specified and directed.
S&F Continous piano hinges stainless steel, bright finish width of flaps when open 40 mm complete all as specified and directed by Engr-in-charge.
S&F Stainless steel handle, 125 mm complete all as specified and directed by Engr-in-charge.
S&F Magnetic catcher for cupboards complete as all specified and directed by Engineer in Charge complete all as specified and directed by Engineer in Charge.
S&F 40 mm wide Mild Steel telescopic channel fixed to drawer with screws complete all as specified and directed by Engineer in Charge.
Supply and fixing Hasp and staple safety type aluminium powder coated with mild steel pin inculding bolt to hinge plate and fix with screws 150 mm size of hasps and staples complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair, brass CP Wall mixer 3 in 1, 15 mm bore, for mixing hot and cold water , screwed down for iron pipe and fixed including bend for shower connection complete all as specified and directed by Engineer in Charge.
S&F sinks made of stainless steel 1mm thick kitchen or labo-ratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm , including 40 mm bore dia CP waste coupling (half/full threaded with 900 mm and PVC waste pipe min 900 mm long complete all as specified and directed by Engineer in Charge.
BUILDING WORKS (ROAD/PATH/CULVERT)
Surface excavation n. exc. 30 cm deeep and averaging 15 cm in any type of soil getting out complete all as specified and directed by Engineer in Charge.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed by Engineer in Charge.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone as in sub base complete all as specified and directed by Engineer in Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness with gray cement & pigment, M-35 Grade complete all as specified and directed by Engineer in Charge.
M&L for 25 mm thick sand filling under floor including watering and consolidation complete all as specified and directed by Engineer in Charge.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork all as directed by Engineer-in-charge.
Removing surplus excavated material (soil) to distance exc. 250 m but not exc 500 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed by Engineer in Charge.
BUILDING WORKS (SEWAGE DISPOSAL)
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for laying of Sewage line, manholes etc and getting out in any type of soil, etc complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick etc complete all as specified and directed by Engineer in Charge.
Removing excavated material (soils) to a distance not exc 50m and depositing where directed etc complete all as specified and directed by Engineer in Charge.
Cutting into existing manholes for connecting new drains 150mm bore pipe including removing existing branch drain pipes of 150/200mm bore & benching to form branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming benching as required and making good surface with plaster etc to match existing , etc complete all as specified and directed by Engineer in Charge.
M&L for 150 mm dia Salt glazed stoneware drain pipes laid in trenches and jointedcomplete all as specified and directed by Engineer in Charge.
M&L for providing cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) 100mm thick bed for 150mm bore pipes including packing under and haunching against the sides of pipes after they are laid tested, etc complete all as specified and directed by Engineer in Charge.
M&L for brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:4) etccomplete all as specified and directed by Engineer in Charge.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in foundation, fillings & mass concrete, manhole sub base etc complete all as specified and directed by Engineer in Charge.
Cement concrete (1:3:6) type C-2 (using 20mm graded crushed stone aggregate) as in surface channels & drains, etc complete all as specified and directed by Engineer in Charge.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork all as directed by Engineer-in-charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete Type B1 (1:2:4) using 20 mm graded stone aggregate as in cover slabs for manholes etc, set in CM 1:4 complete all as specified and directed by Engineer in Charge.
S&F TMT MS bar 6 to 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia of Gd.I, IS- Fe-410-W 432 (Part I) (Gde.E-250) Part- I as specified complete all as specified and directed by Engineer in Charge.
E/M WORKS (INTERNAL ELECTRIFICATION)
Taking down Copper/Aluminium Point Wiring any type in PVC casing caping /PVC Conduit (Light, Fan, Socket or Power) including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge.
Taking down/out unserviceable main switches and DB's including MCBs of any size / type and of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge.
M&L for concealed Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
All as per Item No 4.03 for One 3 Pin Switch socket Combination 6 amp on the independent board complete all as specified and directed by Engineer in Charge.
All as per Item No 4.03 for One 3 Pin swich socket Combination 6 amp on the same board with other switches complete all as specified and directed by Engineer in Charge.
M&L for concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F 1X9/10 watt incl taking down wall mounted, new generation LED batten for multipurpose application, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F Bell Push Button 6 Amp, Flush type suitable for Call Bell, complete all as specified and as directed.
S&F Call Bell Electric Single Pole, 230 Volt, AC supply, Ding Dong type and , complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F 1X18 watt incl taking down wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 to 63 Amp, 240 /415 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F MCB Single Pole 40 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
Collecting Fans from Store yard of AGE E/M, ceiling/exhaust/wall mounted fans of any size and any make/model, moving to reputed workshop as directed by GE/Engineer-in-Charge, dismantaling the same, cutting and removing the old defective/burnt out winding, cleaning the core of the fan motor, re-winding the fan motor by using machine with supper enemelled copper winding wire and using insulating materials, varnishing the assembly and re-assembling the fan including testing etc. complete all as specified and directed by Engineer-in-Charge. MAKE of winding wire : Devi Dayal/Chetak/HTP Thulax. Note: (a) All defective/unserviceable parts/items other than winding wire, varnish, insulating material, bearings, capacitors and flexible wires shall be measured separately and paid for under respective item of this schedule.
All as per item No. 4.23 here-in-before but for ceiling fans of 1200 mm sweep any type complete all as specified and directed by Engineer-in-Charge.
All as per item No. 4.23 here-in-before but for exhaust fans of 230/300 mm sweep any type complete all as specified and directed by Engineer-in-Charge.
S&F in repair capacitor 2.5 mfd fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair capacitor 3.15 mfd fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Ceiling fan blades (Set of three blades) suitable for 1200/1400 mm sweep ceiling fan duly painted with synthetic enameled paint fixed in replacement complete all as specified and directed.
S&F in repair Exhaust fan blades (Set of three blades) suitable for 230/300 mm sweep duly painted with synthetic enameled paint fixed in replacement complete all as specified and directed.
S&F in repair MS clamps for ceiling fans complete with rubber real of any size/make/sweep/model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for suitable size of bolts, nuts, body screws, GM bushes and safety pin/split pins for any type/size/make and model of extg fan as required , fixed in replacement, complete all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed by Engineer in Charge.
M&L for Shaft for any type/size/make and model of fans as required fixed in replacement, complete all as specified and directed.
M&L for painting Ceiling Fan/ Exhaust fan/ Wall mounted fan with One coats of white synthetic enamel paint by spraying including filling with fillers one coat after cleaning all dust etc and marking MES No with enamel paint all as directed by Engr-in-Charge.
S&F in repair Ball bearing of ceilling fans of any sweep/size/make/ model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Ball bearing of Exhaust fansof any sweep/size/make/ model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Upper and lower canopy complete with adjusting screws as required, fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Down rod 20 mm dia, GI tubing medium grade 45 cm to 60 cm long as require fixed in replacement at site complete all as specified and directed.
S&F in repair Louvers made of GI Sheet, suitable for 450 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
S&F in repair Louvers made of GI Sheet, suitable for 230/300 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
Taking down Ceiling/ Exhaust Fan and refixing its original position after completion of building works, complete all as specified and directed by Engineer in Charge.
M&L for dismantaling and taking down complete 25/35/50 Ltr capacity geysers from site and brought to E/M store yard & Refixing the same after carrying out following works:- (i) Complete cleaning and de-scaling of inlet and outlet connections, inner tanks, fittings, fixtures & outlet pipelines etc with suitable chemical agent. (ii) Complete servicing and maintenance.
GUPTA AND ENGINEERS
classic estate developers
VISHAV CONSTRUCTIONS
M/s Luxmi Constructions
REYANSH GARG AND COMPANY
STELLAR PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .