Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹31.9 L
EMD Value
₹63,830
Closing Date
19 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT GARRISON ENGINEER (I) AF AMRITSAR
ASSISTANT GARRISON ENGINEER (I) AF AMRITSAR-143001
SPECIAL REPAIRS TO STATION ARMOURY ALONGWITH ROOF TREATMENT AT AIR FORCE STATION AMRITSAR CANTT
2025_MES_737630_2
AGE (I) AF/ASR/T-24/2025-26
Open Tender
Civil Works
Item Rate
ASSISTANT GARRISON ENGINEER (I) AF AMRITSAR
CLASS D AND CATEGORY a (i) and b (i)
8 documents required · 8 mandatory
₹500
AGE (I) AF AMRITSAR
₹63,830
Yes
30 Oct 2025
29 Oct 2025
26 Nov 2025
29 Oct 2025
19 Nov 2025
12 Nov 2025
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for machine cut kota stone slb flooring & skirting 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including ,cutting and mirror polishing and 20 mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 complete all as specified and directed
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed. Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L for polishing of Old surfaces on marble/ granite/ kota stone/ stoe work where ever required, intial preparation includes grounding the surface evenly with machine fitted with fine grade blocks (No. 120) thereafter final grinding with machine fitted with the finest grade grit blocks (No. 320) carried out the day after the first grinding completed. After the final polish, oxalic acid shall be dusted over the surface at the rates of thirty three (33) gms. per square metre sprinkled with water and rubbed hard with pad of wooden rags. The following day the floor shall be wiped with a moist rag and dried with a soft cloth and finished clean complete all as specified.
M&L for demolition of stone slabs laid or bedded in any mortar all as specified and directed
M&L for laying 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite over screed bed of cement mortar 1:4 of 10mm thickness along with rounding to edges all as specified and directed by Engr-in-charge.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and directed .
M&L, Brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and as directed.
M&L for cutting holes in brick walls in cement mortars exc. Half brick not exc one brick for inserting hold fasts of doors/windows etc and making good dismantled portion in CM 1:3 or cement mortar 1:2:4 type B-1 all as specified and directed by engineer in charge .
M&L rendering 15 mm thick in CM 1:4 on fair faces of new brick work or concrete surfaces , finished even and smooth without using extra cement all as specified and as directed.
Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with water etc complete all as specified & directed by EIC .
M&L for Rendering 12 mm thick in cement mortar 1:6 on brick or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces incl WPC, finished even and smooth without using extra cement all as specified and as directed.(WPC will not be paid separately)
M&L 5mm thick cement plastering on ceiling in CM 1:3 over fair faces of concrete surfaces and rendering is to be finished even and smooth without using extra cement complete all as specified and directed by engineer in charge .
M&L for rendering 20mm thick cement plaster in layer of (15+5mm) on concrete surfaces in cement mortar (1:4) in patches and repairs at columns, chajja, canopy,ceiling and soffits finished even and smooth without using extra cement using GI chiken wire mesh having dia( 0.71mm and mesh size of 12mm) upto 7 m height as directed including necessary scafolding arrangement as required at site complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of 1st quality acrylic distemper(ready mixed) havingVOC content less than 50gms/litre over and including 1mm thick Birla/JK wall care putty to obtain smooth regular/even finish over a coat of primer, complete all as specified and directed.
M&L for preparing new plastered surface and applying three coats of whitewash on plastered surface of ceiling all specified and directed by Engr-in-charge.
M&L for two coat synthetic enamel paint over a coat red oxide primer on new steel surface of any description over 10 cm width or girth not otherwise described including prepration of surface complete all as specified and directed
Material and labour for complete removal of existing treatment including fascias of walls, coulmns etc by scrapping to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and make good smoothen surface by sand paper after application of wallcare putty of 1mm thickness and applying one or more coat of first quality Interior acrylic distemper of approved colour of approved make ,prepare the surface even and smooth all as specified and directed by engineer in charge . Note :- Allow 6-8 hrs to dry the surface in subsequent coats of primer and distemper and including necessary scaffolding at any height complete all specified and directed by Engr-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft & loose soil.
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 50 mm bore/dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part- 24) with high ring stiffners & crush resistance capacity, etc., laid in trench for protection of cable complete all as directed. Make: Finolex, Prime, Supreme
M&L for 50 mm thick PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in filling & mass concrete, sub base, complete all as specified.
M&L for demolition of PCC in ground floor pavings n exc 15 cm thickness (below or above ground level) all as specified and directed by Engr-in-charge
M&L for 75 mm thick, plain cement concrete (1:3:6), type C-2, (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and as directed. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Per Quintal
M & L for PCC (1:3:6) type C-2 with using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed
S&F mild steel bolts purpose made with hexagonal or square head one end and screwed the other , or screwed both ends; each screwed end to be fitted with washers and one hexagonal nut exc. 30 cm long , having dia not exc 12mm all as specified and directed by EIC .
M&L MS plate(plain or chequred)channels,square cut or notched (ordinary and counter sunk)forming holes, without any attachment also fastening and fixing completeall as specified and directed by EIC.
S& F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) all as specified and directed by engineer in charge
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 all as specified and directed by EIC.
M&L for dismantling of wrought iron/mild steel work of any description not all as specified and directed by Engineer-in-charge .
M&L Framed work such as grills, gratings , etc with ends of bars shouldered and/or riveted, or forged into spikes; framed gaurd bars;barred iron doors ;ladders; framed balusters;walk ways;railings; frameworks of water tanks and similar work conforming to Fe 290.Gde-E-165 for portions framed and hung as gates , including hand made sliding bolts etc in doors or gates of angle or other section with gusset plates, rails, braces, etc., fixing complete all as specified and directed by EIC.
M&L for Dismantling of brick tiles or terracing tiles single layer along with coping and ghol on roofs all as specified and directed
Demolition of Mud in roof any thick ness including plastering and leeping (Whether full thickness removed or only a part therof) along with removal outside of defence land as directed
M&L for brushing neat cement slurry with 3.0 kg per sqm complete all as specified and directed.
M & L for providing cement concrete type B1 1:2:4 (20 mm graded aggregate) in roof, Kerb or mud stops, rounded chamfered on edges before treatment of roof surface all as specified and directed by EIC.
M&L for Cement concrete type B-2 (1:2:4) using 20 mm graded stone aggregate mixed with & incl. water proofing compound as in roof padding / floor subbase averaging thickness of 50 mm on roof to maintane slope correction of the depresses/ unduation portion complete all as specified. Note : WPC shall be measured and paid separately.
Supply water proofing compound to mixed with cement mortar etc complete all as directed.
M&L for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( wt. not less than 150 gms/sqm) laid on one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm primed surface by torch application method after allowing 24 hours for primer to dry complete all as specified by Engr-in-charge.
Note: Sheet should be five layered prefabricated Atactic Polypropyleen Polymer (APP) modified 3 mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 160 gsm polyester non- woven fabric. Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green,10mm thick 1:4 cement plaster shall be laid .The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter nd dust prior to the appliction of primer. On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry . Laying off APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. all overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with brutane torch. the treatment shall be done by the approved authorised applicatiors.
Material and Labour, 40mm thick brick tiles laid on and including 15 mm thick cement screed bed in CM (1:6) using grey cement and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement laid on concrete roof, complete all specified and directed.
All a per Srl item No 41 above but except tiles (old serviceable dismantled tiles obtained from Srl item No 34 shall be reused after necessary cleaning of mortar)
Taking down shutters of any description exc.2 sqm each removing to store complete all as specified and directed.
Taking down shutters of any description exc. 1sqm and n exc. 2 sqm each removing to store complete all as specified and directed.
S & F for flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, thickness 30 mm,etc complete all as spd and directed.
M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
S & F ISI marked floor door stopper of aluminium alloy body 140 mm cover plate and tounge , anodized with hard drawn steel spring fixed in floor as specified and directed by Engr-in-charge.
S&F 200 mm ISI marked in size aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 250 mm ISI marked in size aluminium alloy, anodised, sliding door bolt with hasp, staple(bolt type) with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete and fixing clips of sheet cast or extruded sections and fixed complete all as specified and as directed.
S&F 100 mm ISI marked in size butt hinges extruded aluminium alloy with galvanised mild steel hinges pin, anodised and fixed type B-21 complete all as specified and as directed.
S&F 150 mm ISI marked in size aluminium alloy handles , anodised, fabricated type, anodised complete all as specified and as directed.
M&L for Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M&L for Demolition of cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M&L for Galvanised iron tubing 15mm bore,medium grade,with all fittings fixed to walls or ceiling or laid in floors, in concealed pipe work cutting and making good the chases upto 10cm girth etc in cement mortar(1:3) after fixing of pipe,incuding taking down of old rusted/u/s GI pipe remove to store or credit, complete all as specified and directed.(Rates for cutting of chases is included).
M&L for Galvanised iron tubing 20mm bore,medium grade,with all fittings fixed to walls or ceiling or laid in floors, in concealed pipe work cutting and making good the chases upto 10cm girth etc in cement mortar(1:3) after fixing of pipe,incuding taking down of old rusted/u/s GI pipe remove to store or credit, complete all as specified and directed.(Rates for cutting of chases is include).
S&F 500 Ltr capacity, Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling old tank all as specified in SSR Part I.
S&F Gun metal globe or gate valves in repair , with iron wheel head screwed both end for iron pipe and fixed of size 20mm dia comp
lete as all specified and as directed.
S&F 20 mm bore Ball brass valves in repair , high pressure , with polythene float valve and flynut complete , screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Supply and fixing in repair harisson rails ,mild steel chromium plated with fixing brackets, stops, rollers ,side flowers etc fixed to wall with screws, PVC plug including taking down existing curtain rod complete all as specified and directed.
M&L for Dismantling of CI/PVC pipe of 150mm dia fixed with cement joint.
S & F 150 mm PVC (SWR) pipe single socket in any length with rubber ring joints fixed in walls or floors all as specified and directed.
M&L for aluminium strip 25 x3.15 mm with porcelain saddles and fixing screws etc for roof conductors and down conductors above ground for lightening conductor complete with epoxy base insulators till centre of earth pit all as specified and as directed by Engr-in- Charge
M&L for Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness ( below or above ground level ) all as specified and directed to facilitate demolition complete all as specified and directed.
Ditto all as per item No 2 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:3 complete all as specified & directed
M&L for 75 mm thick PCC 1:2:4 type B-1 (using 40 mm graded stone aggregate) as in flooring to be laid in alternate bays etc all as specified and as directed by EIC.
M & L Precast cement concrete type B-1, 1:2:4 block of size 20cmx20cmx15cm (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 all as specified and directed by Engr In Charge
Material and labour for Point wiring for One light / Celing fan/ Exhaust fan point/Bell point, controlled by one switch 5 Amp SP one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality
M&L for removal of excavated material exc. 500m upto distance of 1 km and depositing all as specified and directed by Engr-in-charge.
Excavating in post holes( or similar holes) each n exc 0.5 cu.m. getting out and removing surplus soil to a distance n.exc 50 m complete all as specified and directed by EIC.
INTERNAL ELECTRIFICATION
) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with 3mm thick bakelite laminated “hylem or Philips“ sheet top cover and machine made brass screw and washers etc complete all as specified and directed Notes;- (i) For Internal wiring colour to be used as per IE rule for Phase - Red/Yellow/Blue, Neutral - Black and Earth – Green (iv) Making good on disturbed surfaces and quoted rate including M&L for white/colour wash (existing colour) to macth with existing surfaces, complete as directed by Engineer-in-Charge (ii) Switch/socket to be measured and paid separately. Make: Grandley, Havells, Poly Cab
(a) For one light/fan/bell point controlled by one 6 Amp one way switch Make: Anchor,Bajaj, Kinjal
S & F of switch piano flush type single pole one-way 6 Ampere complete all as specified and directed. Make: Legrand, Schninider,Kinjal
S & F of switch piano flush type single pole one-way 16 Ampere complete all as specified and directed. Make: Legrand, Schninider,Kinjal
S & F of 6 Ampere socket outlet flush type, multi purpose suitable for 2 and 3 pins (Total 5 Pins) complete all as specified and directed. Make: Legrand, Schninider,Kinjal
Taking down carefully copper / aluminum point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, lamp holders, bracket, light fittings, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls, floors etc as per existing complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 6 and 16 Ampere flush type with shuttered complete all as specified and directed. Make: Legrand, Schninider,Kinjal
S & F of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed. Make: Legrand, Schninider,Kinjal
Supply and fixing LUMENO LED tube light fitting 1x20 watts Havells with PVC insulated flexible copper cable from ceiling rose to tube light fitting complete all as per specified and directed. Make: Orient Electric, Wipro, Philips
S&F of lamp holder PVC / polycorbonate type insulated body with back plate suitable for batten fitting / angle fitting complete all as specified and directed.
Taking down old Ceiling fan/exhaust fan of any size, sealing cable end, dismantling blades and removing fan and blades to store as specified and directed (Fan shall be deposited to MES Store yard)
Painting of Ceiling fan/exhaust fan of any size complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts
Hanging and fixing old Ceiling fan/exhaust fan of any size after painting and connecting up including provision of cable from ceiling rose or connector to fan as specified and directed (Fan shall be collected from MES Store yard)
Supply and fixing louvers of exhaust fan suitable for 300/380/450 complete all as specified and directed.
Taking down existing old water heater 50 ltr capacity from site and refixing the same after repair which includes change of element, thermostat, PVC Connections (02 Nos) , painting with synthetic enamel paint including accessories such as safety valve, thermostate, NRV, connection piece etc.
M&L for Shifting of Split type Air Conditioning Indoor and outdoor unit from existing location to MES Store yard and refixing the same after roof treatment complete all as directed including taking down all electric connections and refixing the same with refill of gas at site with necessary transportaion complete all as specified and directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 volts complete all as specified and dircted. Make: Legrand, Schninider,Kinjal
M&L for sub main wiring two single core 6 Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 6 sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4) Make: Grandley, Havells, Poly Cab
Supply and Fix epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and as directed Note: Epoxy base insulator to be fixed at a every distance of 1.4 mtr of strips
M&F point wiring with 1.5 Sqmm (nominal Area), 650 /1100 Volts grade, PVC insulated fire resistant multi stranded unsheathed copper conductor cable, in and including ERW rigid steel heavy duty conduit, ISI marked with all flame proof conduit fittings, accessories and junction boxes as per site requirement for one light point/buzzer point controlled by one switch to be provided complete all as specified and directed by Engineer-in-Charge. Make of Cable : Havells / Finolex / L&T.
(b) All as per item No. 68 hereinbefore but wiring for one 3 pin 6 Ampere socket outlet point on the same board, controlled by other switch complete all as specified and directed. Make: Legrand, Schinider,Kinjal
M&F Flame proof LED tube light fittings, 2 X 16 Watt, with two Nos cable entries and one entry plugged with proper flame proof plug, terminal block, heat resistant glass of Borosil Make, wire guard and necessary flame proof flexible metallic conduit tested by CMRS Dhanbad and conforming to IS 2069 (Part I) of 1984. Make : Crompton Greaves or Sudhir or Shyam.
Procedure of roof treatment:- (i) Clean the roof:- M&L for preparation of surface by scrapping and properly cleaning the surface by removing loose/ uneven particles with wire brushes and other tools, complete in all respect (ii) Make small repairs and rendering:- Filling of cracks with smart Care Hybried PU sealant wherever requiered and applying 15mm thick rendering in CM 1:4 alongwith covering and applying smart care damp proof ultra and assure proper curing of plaster complete all as specified and directed by Engr-in-charge. (iii) Laying of membrane and undiluted coats:- Laying of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun Reflectivity Index (SRI) of 105 on top of roof in three coats @ 1.2 litre/ sqm to be reinforced with 45 GSM fiber mesh, having minimum elongation of 350%, tensile strength 2.9 Mp and shall have crack bridging ability upto 2.5 mm and shall resist 10 bars of hydrostatic pressure, reduces surface temperature upto 10 degree celsius. The system conists of self priming with 33% ditution followed by two undiluted coats (dry film thickness of complete appliaction/ system not less than 500 microns). (iv) Ponding test:- Ponding test shall be done after application of material
Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.5 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm. Including taking out old u/s earthing.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Supply, install, test and commissioning Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 Make: Agni
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply, install and testing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V for flame proof tubelight fitting as specified and directed by Engr-in-charge Make : Crompton Greaves or Sudhir or Shyam.
Supply , laying jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 25 Sq mm 4 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, including taking out old cable with protection bricks
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as specified and directed.
M & L for vertical type sheet steel enclouser distribution boards, double door factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulated copper jumpers from the MCCB to the out going circuits (one incoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wire of suitable rating including MCCB 160 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. and 12 Nos MCBs 6-32 Amps, complete all as specified and directed. Make : Legrand, ABB , HPL
S&F Air termination single pointed aluminum rod 12 mm dia and 300 mm long complete all as specified and directed by Engr-in-Charge
M&L, GI pipe light grade 40 mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc, including taking out old GI pipe, all as specified and directed. Make: Jindal, Oswal, TATA
Per 1000 Nos
Supply and fix, GI pipe 25 mm bore light grade (ISI marked), cut to pieces of 75 CM length or as directed by Engineer-in-Charge,
Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.31 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
tenderdocument.pdf
Tender Documents • 1.78 MB
BOQ_825930.xls
BOQ • 1.04 MB
appx.pdf
Additional Documents • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .