Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹26.9 L+₹13,789 (0.51%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹27.0 L+₹17,360 (0.65%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_345605_2
GE(S)/PAT-07/NS/2020-21
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha And Mil Stn Sangrur.
Refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹60,000
Yes
17 Aug 2020
29 Jun 2020
18 Jul 2020
29 Jun 2020
16 Jul 2020
2 Jul 2020
29 Jun 2020 - 1 Jul 2020
60 days
Amount
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6mtr mean raidus bulit in C:M 1:6, complete all as specified and directed.
All as per serial item no 2 but except bricks.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, drains, etc., and getting out in soft/loose soil complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided, complete all as specified and directed.
Cement concrete 1:4:8 type D-2 using 40mm graded agg as in foundations fillings and mass concrete, complete all as specified
Taking down cement plaster or any description from brick wall or concrete surface, racking out joints hakcing for key scrubbing down with water etc, including removal of debris from site, complete all as specified and directed.
M & L 15mm thick cement plastering in cement mortar 1:4 brick or concrete surfaces of wall finished fair and even without using extra cement, using WPC (WPC supply onlr shall be measured and paid under respective item of schedule) complete all as specified and directed.
PCC 1:2:4 type B-0, (12.5 mm graded stone aggregate), as in coping, bed blocks, DPC etc including necessary formwork, complete all as specified.
PCC 1:2:4 type B-I, (20mm graded stone aggregate),40mm thick as in floor / sub base of floor finishing surfaces of concrete even and rough without using extra cement all as specified.
Demolition of cement concrete (reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demolition, complete all as specified and directed.
M & L Precast RCC 1:2:4 type B1 using 20mm graded crushed stone agg as in manhole / drain cover slabs, of any thickness, size or shape including necessary form work, finished concrete surfaces fair & even in CM 1:6, complete all as specified and directed by Engr - in -Charge.
TMT bars 8mm dia and over cut to length bent to shape required incl cranking bending, spirally , hooking ends and binding with mild steel wire not less than 0.9mm dia (annealed) complete all as specified and as directed by Engineer-in-Charge. (Note : The payment shall be made only after placing of cover on manholes)
M&L in repair Reinforced concrete pipes, class NP2 laid and jointed in cement mortar (1:1) complete with collars bore in pipes 300mm, including demolition by breaking up of old drain pipes of SGSW / AC / RCC, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
Removal of excavated soil exeeding 50 meter and deposting where directed at a level n. exc 1.5 M above the starting point, complete all as specified and directed
Preparation of newly plastered surfaces of walls etc., and applying three coats of white wash complete all as specified
S&F 1.60mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed.
Framed work as in doors or gates of angle or other section as in repairs with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, including taking down existing gate complete all as specified and directed.
Preparing new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-charge.
S&F 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, laid in trenches or in floor, complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc complete all as specified and directed.
PCC 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
M & L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping/ gola including necessary form work all as specified and directed
Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4 Kg/Sqm water proofing membrane, black finished, reinforced with non-woven polyster matt make as approved, consisting of a coat of bitumen primer @ 0.40 Ltr/sqm by the same membrane manufacturer, of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps. Over the coat , the layer membrane shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturer's instructions. The vitalphysical and chemical parameters of the membrane shall be as under:- (i) Joint strength in longitudinal and transverse direction at 23 degree C as 650 / 450N/5cms. (ii)Tear strength in longitudinal and transverse direction as 300 / 250 N / 5cms. Softening point of membrane not less than 150 degree C. Cold flexiblity upto 20 degree C when tested in accordance with ASTM (D-5147). (iii) The laying of membrane shall be got done through the authorized applicator of manufacturer of membrane only.
M&L for Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting, reconnecting and re-fixing in same position, complete all as specified and directed.
Supply & fix 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, fixed to walls with flat iron clamps of size 25 x 3mm, bolts, washer, nuts etc including taking down old pipe, complete all as specified.
S&F PVC (SWR) bends 110mm bore of any radius with access door.
Surface excavation not exc 30 cm deep and avg 15 cm deep and getting out in soft and loose soil complete all as specified.
Glass dividing strips 38 mm wide and 3mm thick laid and fixed in position for laying floor finishes complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and dirrected.
Coloured glazeded ceramic tile 200x300x7 mm thick in dado set and joint in neat cement slurry and pointed in white or coloured cement to match over & including screed of 10 mm thick rendering in cement mortar (1:4) complete all as specified.
Supply only liquid water proofing compound.
Supply and Laying steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for 15mm dia, complete all as specified and directed.
Supply and Laying steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for 20mm dia, complete all as specified and directed.
S&F 15mm bore bib cock chromium plated fancy type, screwed down, screwed for iron pipe or for brass ferrule.
Supply and fix stop valves 20mm cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws all as specified and directed.
S & F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc all as specified and directed.
PCC 1:2:4 type B-I, (20mm graded stone aggregate), 75mm thick as in floor / sub base of floor finishing surfaces of concrete even and rough without using extra cement all as specified.
PCC 1:3:6 type C-I, (20mm graded stone aggregate), 75mm thick as in plinth protection, finishing surfaces of concrete fair and even complete all as specified.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6mtr mean raidus bulit in C:M 1:4, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls etc and applying two coat of cement base paint over a coat of chalk whiting (as primer) complete all as specified and as directed.
Pre-painted GI frame work as in grid for False ceiling comprising of protected GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having to equal flanges of 15mm each and web of 45 mm suspended from soffit and approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 metre length) of 0.55mm thickness having knurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and hangers 6mm dia GI (up to 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x3mm size 60mm long complete with and including 7mm thick PVC laminated gypsum tiles of size 595x595mm of approved design of make Acoster/Ploca/ Armstrong or equivalent as approved by GE all as specified & directed including taking down of old ceiling of any description.
S&F Mild steel screw bolts (machine made) of 5 to 10 mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified.
Factory made Pre-cast concrete blocks of size 300mmx150mm & thickness varying 150mm at bottom and 100mm at top M-20 (Design mix ) rounded or chamfered edges as in kerb stones set in CM 1:4 complete all as specified and directed
M &L for Rubber moulded Machine pressed precast concrete interlocking paver block(available in different colour for making patterns) any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with gray cement and pigment laid over 25mm thick sand cushioning complete all as specified and directed.
Chequered cement concrete tiles With mixture of white and grey cement in equal proportion and no pigments, machine pressed, of size 20cm x 20cm x 25mm thick or any larger size upto 30cm x 30cm x 25mm as approved by Engineer in charge laid over 20mm thick cement screed in CM 1:4, complete all as specified and as directed
10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick of size 300x300 in floors etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match over and including 20 mm thick screed bed of CM 1:4 laid over 25 mm thick PCC 1:2:4 type B-0, complete all as specified and directed.
Supply and fix stop valves 15mm cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F Rotational molded polythene water storage tanks (cylinder vertical with closed top ) of capacity 1000 ltrs, double walled hoisted and fixed in position including 20 mm dia ball brass valves, high pressure, with plolythene float and fly nut of 20mm bore to connect GI pipecomplete screwed for 20mm iron pipe including GI nipple /union as specified in SSR, complete all as specified and directed.
S&F in repairs vitreous china wash basin, size 550 x 400mm white including MS brackets, and waste coupling brass chromium plated & waste pipe of 32mm dia and 15mm dia CP pillar tap. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed, complete all as specified and directed.
S&F brass chromium plated angle cock 15mm bore with crutch or butterfly handle screwed to iron pipe, complete all as specified.
Factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S & F 100 mm size PVC butt hinges all as specified and directed.
S & F 125 mm PVC handles all as specified and directed .
S & F 200 mm long PVC tower bolt all as pecified and directed .
M&L Plain cement concrete ( 1:3:6), Type C-2, using 40mm graded stone aggregate concrete bed laid to falls in trenches in any depth including packing under and haunching againt the sides of SGSW pipes for the 150mm bore after they are laid and tested complete all as specified.
Supplying,laying,jointing and testing Salt Glazed stone Ware (SGSW) pipe of grade A for the 150mm dia bore, in trenches in any depth complete all as specified.
M&L RCC 1:2:4 (using 20mm graded aggregates) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work, not exceeding 200 mm thick complete all as specified and directed.
M&L 5mm thick cement plastering in cement mortar 1:3 as on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coat of white wash on ceiling surfaces all as specified.
Hard Core of broken bricks of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet with 1.00 to 1.50m long tube, including making connection to inlet flush pipe, & to 'P' or 'S' drain trap, incl supply of long special 'P' or 'S' trap, complete all as specified and directed.
S&F 10 ltr capacity PVC valve less syphonic action type flushing cistern in low level coloured with inlet ball valve float and handle including brackets,flush pipe complete all as specified and directed.
M&L brick work with sub class 'B' brick straight orcurved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed.
S & F coloured vitreous china Urinal Half stall type complete incl providing and fixing plugs bedding urinals against wall in CM 1:2 securing urinals to plugs with and incl 60 mm long brass screws pointing around urinal back in cement incl flush pipe all as specified.
S&F Rotational molded polythene water storage tanks (cylinder vertical with closed top ) of capacity 500 ltrs, double walled hoisted and fixed in position including 20 mm dia ball brass valves, high pressure, with plolythene float and fly nut of 20mm bore to connect GI pipecomplete screwed for 20mm iron pipe including GI nipple /union as specified in SSR, complete all as specified and directed.
S&F soap dish chromium plated fixed with brass screws complete all as specified and directed.
S& F Tubular towel rail brass chromium plated 20 mm dia,D type 60 CM large between flages, complete all as specfied and directed.
Construction of Soakage wells of size 1.2 M dia X 1.5M depth as per drawing no STD 1173 (C) (Sheet no 1R/2 & 2R/2) of CECZ. excavation in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25 and Filling with brick bats, complete all as specified and direceted,
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper conductor for one light / exhaust fan and including PVC rigid non metallic concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FR single core stranded copper earth continuity conductor controlled by one switch one way complete all as specified and directed (Switches shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth), complete all as specified and directed.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply & fixing modular white cover plate with frame for fixing of modular switches for 4 module, complete all as specified and directed.
S& F blank spacer plate for single module, complete all as specified and directed.
Supply & fix Sheet metal enclosurefor DB’s suitable for MCBs of single pole and neutral 4 way double door type, 240 volts, concealled, complete all as specified and directed.
S&F MCB , SPN, 240 Volt , 10 Amps for fixing in DBs of including proper thimble connections complete all as specefied and directed.
S&F MCB , SPN, 240 Volt , 06 Amps for fixing in DBs of including proper thimble connections complete all as specefied and directed.
S&F LED Regal batten (suitable for fixing 20 watt LED rod) upto 1 x 22W, complete all as specified and direceted.
S&F LED tube light photon ultra ( 1 x 20 W single side connection), complete all as specified and direceted.
S&F LED tube light fitting 10 watt with all accessories, complete all as specified and direceted.
Supply and fix exhaust fan AC single phase 230Volts of size 300 mm sweep, heavy duty, 1400 RPM with plastic body, lowers complete opening in wall with suitable size for fixed Exhaust fan incl make in good to the disturbed surface MS bolts, grouted to wall and connecting up including provision in cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting arrangements complete all as specified and directed at site.
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 5 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed.
NARINDER KUMAR SONS
M/s Pawan Kumar Goyal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .