Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.6 L+₹18,055 (2.83%)Rejected-Finance OPPOSITE RADIO STATION TOWER TILAK NAGAR SAGAR ROAD BIKANER 334001 RAJASTHAN | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.1 L+₹66,853 (10.5%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.3 L+₹90,230 (14.1%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹8.3 L+₹1.9 L (29.6%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
14 Oct 2021, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
MISC REPAIR AND CLEANING OF SEPTIC TANK, MANHOLE AND SEWAGE LINE UNDER ZONE -II A AREA AT JAIPUR MIL
2021_MES_476045_1
GE/J-23/2021-22
Open Tender
Civil Works
Item Rate
360 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹24,000
Yes
20 Nov 2021
17 Sept 2021
16 Oct 2021
17 Sept 2021
14 Oct 2021
1 Oct 2021
17 Sept 2021 - 30 Sept 2021
Amount
M & L cleaning of blocked Nahani trap/Gully trap/Floor trap of any dia & removing silt/sludge & cleaning the blockage with water complete all as specified & directed. NOTE :- Quoted rates shall be inclusive of arrangement of mechanical instruments & water required. No extra shall be admissible on this account.
Cleaning of sewage line by roding manhole to manhole, manually, removing sludge/foreign material completely and making smooth flow of sewage water for 150mm dia bore pipes complete all as specified & directed.
Cleaning of sewage line by mechanically manhole to manhole, removing sludge/foreign material completely and making smooth flow of sewage water for 150mm dia bore pipes complete all as specified & directed. NOTE :- Quoted rates shall be inclusive of arrangement of mechanical instruments & water required. no extra shall be admissible on this account.
Cleaning of sewage line by roding manhole to manhole, manually, removing sludge/foreign material completely and making smooth flow of sewage water for 200mm dia bore pipes complete all as specified & directed.
Cleaning of sewage line by mechanically manhole to manhole, removing sludge/foreign material completely and making smooth flow of sewage water for 200mm dia bore pipes complete all as specified & directed. NOTE :- Quoted rates shall be inclusive of arrangement of mechanical instruments & water required, no extra payment shall be admissible on this account.
M & L for repair of punching sewage line of any dia and sealing / making good with CM (1:4) / PCC (1:2:4) as required including earth work in any type of soil and any depth, returning, filling in and ramming complete all as specified & directed.
Cleaning of manholes and inspection chamber of following depth and size including removing sludge and foreign material out of MOD land including cleaning the manhole with clean water upto entire satisfaction of EIC complete all as specified and directed :-
60 x 60cm and depth upto 100cm
120 x 90cm and depth upto 150cm
120 x 90cm and depth exc. 150 cm but not exc 300cm
120 x 90cm and depth exc. 300cm but not exc 450cm
Circular dia 1.80m and depth exc. 150 cm but not exc 300cm
Circular dia 1.80m depth exc. 300cm but not exc 450cm
M&L cleaning and desludging of existing septic tank of any capacity / sump well of any dia and depth including taking out sludge in any form and other foreign materials etc viz sediments sand ash, grease, fibre roots or vegetation etc by manually or by mechanically equipment or by way of any other suitable means and removing the sludge out side MOD land by any means all as specified and directed by Engineer-in -charge. Note :- The sepatic tank/ sump well shall be dewatered first and cubic contents of remaining sludge shall only be included in this rate.
Excavation in trenches not exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shaft , wells, cesspits, manholes, pier holes, etc n. exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/ loose soil.
A as per item No 09 above but depth exc 1.5m but not exc 3m depth
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/ loose soil.
Removing excavated material n.exc 50m & depositing where directed at a level n.exc 1.50m above the starting point in soil.
M&L concrete bed to dain pipes 150mm dia cement concrete 1:4:8, type D-2 including packing under, and haunching against the sides of pipes after they are laid and tested in all as specified
M&L concrete bed to dain pipes 200mm dia cement concrete 1:4:8, type D-2 including packing under, and haunching against the sides of pipes after they are laid and tested in all as specified
Demolition and breaking up drain pipes ( Salt glazed ware, AC or reinforced concrete 150mm dia complete all as directed.
All as per item No 15 above but 200mm dia
M&L reinforced cement concrete pipes 150 mm bore of pipes, class NP-2 laid in trenches and jointed complete with collars
M&L reinforced cement concrete pipes 200 mm bore of pipes, class NP-2 laid in trenches and jointed complete with collars
Demolition of stone or brick masonry built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles
M & L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius using old size brick built in CM 1:6.
M&L for walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in CM 1:4 all as specified
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM 1:4 finished even and smooth without using extra cement.
M&L rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth withiut using extra cement complete all as specified
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in surface channels and drains and cenching including finishing the top of benching even and smooth with using extra cement
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc.
M&L precast RCC 1:2:4 type B-1, using 20mm graded stone aggregate for manhole cover including placing over manhole all as specified including demolition of old RCC manhole covers. Note :- Reinforcement shall be measured and paid separately.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 27 above but 6mm to 8mm dia
S&F mild steel framed bracket of flat iron confirmed to GE-290 (Gde E-165) around manhole cover of any size, cut to shape welded, riveted etc complete all as specified
Cutting into existing manholes/ septic tank for connecting new drains making good to pipe and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1, smooth finished and reforming benching as required for 150mm bore pipe
All as per item No 30 above but 200 mm bore pipe
Cleaning of SOAK WELL of size 2.4m dia, 4.5m depth ( overall depth) using mechanical pumps diesel driven with fuel, operator and necessary excavation on half buried soil and disposed off soak well water etc in pits including necessary excavation and earth work for pits etc in soft/ loose soil complete all as specified
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for
M&L PCC 1:5:10 type E-2 using 40mm graded stone aggregate in foundations, filling and mass concrete in sunken floor
M&L applying hot bitumen blown type 85/25 grade two coat on concrete/plaster surfaces at the rate of 1.5Kg per Sqm per coat in suken floor
M&L rendering 15mm thick on fair faces of brick work or concrete surface in two layers (5mm thick in CM 1:4 over 10mm thick in CM 1:6) finished even and smooth without using extra cement mixed with water proofing compound @ 3 % of cement by weight on top layers. Note :- WPC will measured and paid separately.
Supply only intergal water proofing compound ISI marked
S&F PVC (SWR) floor trap of 75mm bore, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified & as directed.
Dismantling of cast iron drain pipe of 100mm bore, jointed in CM and taking out from trenches/ from wall. Note :- Excavation & earth work shall be measured and paid separately.
Dismantling of cast iron drain pipe of 75mm bore, jointed in CM and taking out from trenches/ from wall. Note :- Excavation & earth work shall be measured and paid separately.
S&F 75mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches complete all as specified and directed.
S&F 100mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches complete all as specified and directed.
S&F 100mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed on walls complete all as specified and directed.
S & F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall, 75mm bore sand cast pipe
S&F 100mm bore cast iron branch piece, single ( equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door
S&F CI cowl 100mm bore fixed to CI pipe complete all as specified and directed.
S&F SGSW gully trap square or round mouthed type 'P' of size 150mm x 150mm with CI grating including raising upto plinth protection with PCC 1:2:4 type B-1, and covered with stone slab complete
S&F as in repair vitreous china squatting pan (Orissa pattern) water closet (white) size 580mm x 440mm with integral foot rests ( excluding flushing cistern and flush pipe ) complete including connection to trap and flushing pipe antisyphonage pipe etc (Demolition of sunken floor treatment is included in this item.)
S&F in repair PVC valveless, syphonic action type flushing cistern 10 litre capacity, low level, white with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low level or high density or PVC, 32 mm dia suitable for low level cistern.
M&L for cleaning of blockage of 150mm dia of pipe between to manhole by braking puncher of SWG pipe, including jointing, excavation, returning filling, and removal of soil complete all as directed.
S&F in repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joint fixed to walls all as specified.
S&F in repair PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joint fixed to walls all as specified.
S&F in repairs PVC (SWR) pipes 110mm fittings such as bend all as specified
S&F in repairs PVC (SWR) pipes 110mm fittings such as Tee all as specified
S&F in repairs PVC (SWR) pipes 110mm fittings such as Socket etc all as specified
S&F in repairs PVC (SWR) pipes 75mm fittings such as bend all as specified
S&F in repairs PVC (SWR) pipes 75mm fittings such as Tee all as specified
S&F in repairs PVC (SWR) pipes 75mm fittings such as Socket etc all as specified
Schedule of Credit
M S GROUP
S.R.Enterprises
UNIVERSAL INFRAPROJECT PVT LTD
JAGDAMBA CONSTRUCTION COMPANY
M/S JALANDRA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .