Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 CrAccepted-AOC | ₹14.3 Cr | L1 | Accepted-AOC Lowest bid found in Order |
| 2 | L2₹18.5 CrRejected-Finance | ₹18.5 Cr | L2 | Rejected-Finance Other Then Lowest Bid |
| 3 | L3₹19.5 CrRejected-Finance | ₹19.5 Cr | L3 | Rejected-Finance Other Then Lowest Bid |
| 4 | L4₹20.8 CrRejected-Finance | ₹20.8 Cr | L4 | Rejected-Finance Other Then Lowest Bid |
Tender Value
Refer Docs
EMD Value
₹11.6 L
Closing Date
3 Apr 2025, 6:00 pmClosed
CEAF Prayagraj
CEAF Prayagraj
PROVN OF DEFICIENT MD ACCN FOR OFFRS AND AIRMEN AT AF STN GWALIOR
2025_MES_697382_1
958455/E8
Open Tender
Civil Works
540 days
Gwalior
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹3,000
GE AF Adm Area Gwalior
₹11.6 L
Yes
8 May 2025
11 Feb 2025
7 Apr 2025
11 Feb 2025
3 Apr 2025
20 Mar 2025
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/ PATH & CULVERT)
Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VIII
Sch A Part IX (SITE CLEARANCE AND EARTH WORK)
Lump sum price worked out by the contractor for Site clearance and Earthwork as listed in Sch ‘A’ Part IX
Sch A Part X (CHAIN LINK FENCING & GATE)
Lump sum price worked out by the contractor for Chain link fencing & Gate as listed in Sch ‘A’ Part X
Sch A Part XI (LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for Lightening protection work as listed in Sch ‘A’ Part XI
Sch A Part XII (HOT WATER SUPPLY)
Lump sum price worked out by the contractor for Hot Water Supply as listed in Sch ‘A’ Part XII
Sch A Part XIII (FIRE FIGHTING)
Lump sum price worked out by the contractor for Fire fighting work as listed in Sch ‘A’ Part XIII
Sch A Part XIV (RAIN WATER HARVESTING/RECHARGE PIT)
Lump sum price worked out by the contractor for Rainwater harvesting work as listed in Sch ‘A’ Part XIV
Sch A Part XV (BARRICADING WORK)
Lump sum price worked out by the contractor for Barricading work as listed in Sch ‘A’ Part XV
Sch A Part XVI (TYRE WASHING POINT)
Lump sum price worked out by the contractor for Tyre washing point work as listed in Sch ‘A’ Part XVI
Sch A Part XV (Miscellaneous Items of B/R and E/M)
Supply and fixing Decorative wall mounted luminaire made out of Metal and Glass, busshed nickle with unbreakable globe suitable for LED bulb and with and inclusive of provn of LED bulb 12 watts B22 complete all as specified and directed.
S & F fancy type 15mm bore, brass chrominium plated ( quarter turn with water saving nozzle) wall mixer with telephonic arrangement and with pipe bend 3 in -1 screwed down for iron pipe all as directed.
S & F 15 mm dia chromium plated brass sink mixer( quarter turn with water saving nozzle with swivel spout ( wall mounted) for mixing hot and cold water , screwed down for 15 mm bore GI pipe completed all as specified and directed.
M & L for telephone point wiring with twin core telephone wire complete all as specified and as directed.
S&F RJ 11 Tele Jack single with shutter 1 module complete with GI box and front cover complete all as specified and as directed.
S&F TV socket Jack single with shutter 1 module complete with GI box and front cover complete all as specified and as directed.
S&F wall mounted fan PVC body, 300 mm sweep 3 speed control complete all as specified and directed For officers Kitchen.
Supply and fixing wall mounted type, high suction, multi speed, filter less, Autocleaning,1400 m3/hr suction, inverter technology, BLDC motor operation, low noise operation, 220V AC, 50HZ, electric chimney having LED indicators and touch sensors to be installed in Kitchens including all accessories as required on the site for removal of vent gases through the ventilators complete as specified and directed. Make:- Elica, Model Kitty plus or equivalent in Kaff/ Hindware.
S&F coaxial cable RG6 CU jelly filled complete all as specified and directed.
M&L for pea gravels of size 5 to 10 mm for filling in bore holes and recharge well complete all as specified and directed.
M & L for stone boulder 50 to 100mm for filliing in recharge well complete all as specified and directed.
Supply, laying & testing for GI tubing medium grade 63 mm dia complete with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.), in trenches, fixed to walls complete all as specified and as directed.
Material & Labour for Foot Valve 100 mm dia Cast Iron with all conneted accessories complete all as specified and as directed.
M&L for construction of new valve pit chamber of size 900mm X 900mm X 600mm including necessary earth work in any type of soil , PCC foundation (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in base concrete, brick work in CM 1:6 with 10 mm thick platser internally and 15 mm thick externally in CM 1:4 upto 15 mm below NGL , 4 mm thick MS cover with hinges and locking arrangements fixed to angle iron frame made out of 40X40X6 mm MS angles, D type handle complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coat of white wash on all plastetred surfaces of valve chambers complete all as specified and directed by engineer in charge .
Supply, design, install and commissioning pumping sets, 5 HP Monoblock, 3 phase, 400V, electric driven 300 LPM at 36 mtr head, 2900RPM/415V/50Hz inclusive of PCC foundation etc with all conneted accessories complete all as specified and as directed.
Supply & fix Cast iron Air release valve with single air outlets, confirming to IS 14845 of size 25 mm dia bore and fixing up in cast iron water supply mains.
S&F Thermo plastic (polystrene) cable junction box, having protection class IP-66 and of over all size 155mmx210mmx92mm (Apprx) having metric nockout cables, the cot on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, washers and two Nos polymide weather proof cable glands of cable sealing range 10 mm to 17 mm ( complete with check nuts) and including 1 Nos 30 amp 4 way cable connector and 1 Nos 6 amps SP MCB. Note :- During connection the incoming and outgoing cables, the continuty of armour to be maintained by shoting them inside the box and earth continuty to be looped for LED fitting for grounding purpose complete all as spcified and directed.
M&L for cutting of existing bituminous road/path/hard standing suitable for laying cable protection pipe 50 mm dia under the road/path/hard satnding at a depth not less than 60 CM below the normal ground level, Returning filling soil and making good the disturbed surface of road/path/hardstanding by using cement concrete mortar 1:2:4 type B1, using 20 mm graded stone aggregate 0.45 mtr wide and 0.30 mtr thick complete all as specified and directed.
Supply, Install, Testing and Commissioning CPRI type tested, factory made sloping canopy on top, totally enclosed, IP 54 dust, weather and vermin proof, CRCA sheet out door LT Panel for 415V, 3 phase 4 wire , 50 Hz AC system with TPN Aluminium bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar , general construction confirming to IS-8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm , entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm) PVC insulated copper conductor cable , cable alleys, cable gland plates in two half inculding LED indicating lamp for all phases and , mounted on suitable PCC foundation for the complete panel base with following detailed specification, control and accessories complete:- OUTER SHELL :- The outer shell shall be made of min 3.15 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges , single door system, lockable/ openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air. The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. INNER SHELL :- Inner shell made of 2.0 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x6 mm, angle iron leg 50x 50x 6mm- 04 Nos, Lt Panel shall be erected on C shape PCC pedestal of suitable size made of PCC 1:3:6 type C2, leg shall be placed on PCC bedding 100mm thick PCC 1:4:8 type D2 and shall be embedded in PCC 1:3:6 type C2, 300mm below GL and 300mm above GL, duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
(A) Incoming :- (a) MCCB 4P, 160A, fixed thermal and magnetic setting, Ics=100%Icu, 35 KA -01 No (B) Out going :- (a) MCCB 4P, 125 A, fixed thermal and magnetic setting, Ics=100%Icu, 25 KA-02 Nos. b) MCCB 4P, 63 A, fixed thermal and magnetic setting, Ics=100%Icu, 25 KA-01 Nos. c) Aluminium bus bar 300 Amp TPN-01 Set (d) CT of suitable ratio 100/5 A- Set of 03 Nos (e) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Set of Three Indiaction LED Lamp Note-:Main Panel(G+5 Bldg) ( Panel No 01)
Supply, Install, Testing and Commissioning CPRI type tested, factory made sloping canopy on top, totally enclosed, IP 54 dust, weather and vermin proof, CRCA sheet out door LT Panel for 415V, 3 phase 4 wire , 50 Hz AC system with TPN Alluminium bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar , general construction confirming to IS-8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm , entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm) PVC insulated copper conductor cable , cable alleys, cable gland plates in two half inculding LED indicating lamp for all phases and , mounted on suitable PCC foundation for the complete panel base with following detailed specification, control and accessories complete:- OUTER SHELL :- The outer shell shall be made of min 3.15 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges , single door system, lockable/ openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air. The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. INNER SHELL :- Inner shell made of 2.0 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x6 mm, angle iron leg 50x 50x 6mm- 04 Nos, Lt Panel shall be erected on C shape PCC pedestal of suitable size made of PCC 1:3:6 type C2, leg shall be placed on PCC bedding 100mm thick PCC 1:4:8 type D2 and shall be embedded in PCC 1:3:6 type C2, 300mm below GL and 300mm above GL, duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom, . An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
(A) Incoming :- (a) MCCB 4P, 63 A, fixed thermal and magnetic setting, Ics=100%Icu, 25 KA -01 No (B) Out going :- (a) MCB TPN 40 A, C type, 16 KA- 01 Nos. (b) MCB TPN 16 A, C type, 10 KA- 03 Nos. (c) DOL Starter suitable for 8 HP and 5 HP,415 V AC -01 Nos each capacity (d) Power contactor 18 Amp and 12 Amp -01 Nos Each (e) Aluminium bus bar 200 Amp TPN -01 Set (f) CT of suitable ratio 100/5 A- Set of 03 Nos (g) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Set of Three Indiaction LED Lamp Note-: ( Panel No 02)
Supply, Install, Testing and Commissioning CPRI type tested, factory made sloping canopy on top, totally enclosed, IP 54 dust, weather and vermin proof, CRCA sheet out door LT Panel for 415V, 3 phase 4 wire , 50 Hz AC system with TPN Alluminium bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar , general construction confirming to IS-8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm , entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm) PVC insulated copper conductor cable , cable alleys, cable gland plates in two half inculding LED indicating lamp for all phases and , mounted on suitable PCC foundation for the complete panel base with following detailed specification, control and accessories complete:- OUTER SHELL :- The outer shell shall be made of min 3.15 mm thick CRCA sheet supported on on MS angle section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges , single door system, lockable/ openable by by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air. The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. INNER SHELL :- Inner shell made of 2.0 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x6 mm, angle iron leg 50x 50x 6mm- 04 Nos, Lt Panel shall be erected on C shape PCC pedestal of suitable size made of PCC 1:3:6 type C2, leg shall be placed on PCC bedding 100mm thick PCC 1:4:8 type D2 and shall be embedded in PCC 1:3:6 type C2, 300mm below GL and 300mm above GL, duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom, . An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
(A) Incoming :- (a) MCCB 4P, 100A, fixed thermal and magnetic setting, Ics=100%Icu, 25 KA -01 No (B) Out going :- (a) MCCB 4P, 63 A, fixed thermal and magnetic setting, Ics=100%Icu, 25 KA- 03 Nos. (b) Aluminium bus bar 200 Amp TPN-01 Set (c) CT of suitable ratio 100/5 A- Set of 03 Nos (d) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Set of Three Indiaction LED Lamp Note-: (G+1 Bldg)
Supply, install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall minimum dimension 900mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :- a) Four pole MCCB, 100 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No. b) Aluminium Bus Bar of 200 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos. c) MCB TPN 32 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters) d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights) e) Digital time switch 16 Amp-01 No f) LED indicating Lamps, g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
Supply, install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 20 nos. energy meters of overall minimum dimension 2000 mm (W) x 1500mm (H) x 300mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :- a) Four pole MCCB, 125 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.(Incommer) b) Aluminium Bus Bar of 200 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos. c) MCB SPN 32 Amps, 10 KA - 20 Nos ( To be connected with 20 Nos Meters) d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights) e) Digital time switch 16 Amp-01 No f) LED indicating Lamps, g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 4.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
(d) Electric starter equipment :- The equipment witll comprise the following:- (i) Maint free Battery duly initial charged as recommended by manufacture & Battery lead of adequate capacity. (ii) Starter motor (iii) Starter gearing (iv) Start/stop push button (v) Alternator/Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut all as per manufacturer's recommendations. (vi) PCC foundation for DG set all as per manufacturer's recommendation or required at site or directed by Engineer-in-Charge. DG Set acoustic canopy shall be from OEM. (e) Auto mains failure panel 415 volts 50 HZ suitable for 50 KVA Gen set, made out of 16 gauge MS sheet cubical type floor mounted front and rear door open able with locking arrangment duly powder coated suitable for and including the following :- (i) Microprocessor based electronic control box for automatic switching ON & OFF of DG set and transfer of load equipped with microprocessor based controller 100% auto, 50% auto manual and 100% by pass arrangment adjustable time delay to engine start, standard setting 3 second adjustable 0-10 seconds, adjustable time delay on tansfer to normal 0-30 minutes time delay (adjustable) to engine cool down 0-5 minutes, adjustable time delay on transfer to emergency 0 -15 sec As Per Manufacturer Recomendatation (ii) Heavy duty air break contractor 4 pole 415 volts, 86 A, 50 Hz, AC supply system with dust over and operating coil voltage 230V with 2 NO 2 NC aux contracts all as required for safe operation under over voltage.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground lev el with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 40mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.
S & F, commissioning and testing factory made compact air insulated vertical copper bus bar truncking system 3 phase 1 neutral with isolated earth (rising bus bar).Copper bus bar strip should be rectangular in section ,low impedence,high conductivity of 250 amp ,450 V,35 KA breaking capacity for phase/neutral and half core earth ,mounted on insulators including seperaters,rate insulation level 1100 volt grade,insulation class F complete with CRACA sheet metal enclosure totally enclosed type ,duly powder coated paint,IP 54 protection including fixing in proper allignment and security by means of brackets,clamp,nut,bolt and screw of adequate size/capacity and number for load cap as recommeded by manufacturer complet with flexible joints,end feed units having facility for plug in /type of box of 32 to 400 amp TPN all as specified and directed. Note- Tap of box /plug in box with protection device for domestic connection shall be paid seperatelly
Supply & fix ,testing & commissioning of plug in box/Tap off box CRCA sheet duly powder coatedpaint with MCCB 63 Amp 4 pole 16 KA rotary handle type & door interlockingwith bus trunckingsystem including provn for cable entry& glandplates for both side & bottom of plug in box & integral earth system complete all as specified and as directed.
M & L Earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead 20x3 mm copper strip connectd to Copper earth plate elcectrode by means of bolts, nuts, check nuts, washers of brass material, thimbles and other end of earth lead strip connected to Isolation transformer and protected by galvanised iron pipe medium grade 40mm bore and watering pipe 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes 20x3mm copper earth lead strip , and protection pipe upto 7.5 metre.
Supply and fixing aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure alongwith fixing arrangement as per manufacturer's recommendations fixed to parapet wall/ staircase / mumty on GI pipe 50mm dia with suitable fixing clamps and steel wire supports complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent.) Note : GI pipe 50mm bore shall be measured and paid separetely under relevant item of BOQ.
S&F DP MCB 6 A with enclosure complete.
Supply and fixing single phase timer panel with 16 Amp Contactor fitted inside a steel enclosure. Make- Indoasian Model: Timelite 16A 3 pole/230V - Analog time switch Cat Ref TL016ABO or equivalent in Legrand/Havells.
Supply and fixing cast iron air realease valve with single air out let, confirming to IS 4845 of size 100 mm dia bore and fixing up in MS pipe 100 mm bore complete set.(01 Near terrace water tank).
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 Core, 4 Sq mm 1100 Volts grade.(For Repeter Panel)
Supply and fixing of signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" x 6" X 8 mm decorative transparent acralic, including fixing arrangement all as specified and directed.(2 Nos at each floor G+5)
Supply and fixing branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090.(One at each floor G+5)
Supply and laying of public Address wire 2 core.(For talk back system)
Supply, Installation, Testing and commissioning of Single master and 8 way slave for talk back system complete as required.(Control Console)
Supply and fixing Fire Extinguisher, water stored pressure type, 9 Ltrs cap, confirming to IS 15683
Supply and fixing Fire Extingusher CO2, 4.5 Kg cap, confirming to IS 15683 (Light Wt Squeeze grip type)
Supply and fixing Fire Extinguisher, Dry chemical Powder, (ABC) Type, 6 Kg cap, confirming to IS 15683
Supply and fixing Fire Extinguisher, Mechanical foam type, 9 liters cap, confirming to IS 15683.
Supply and fixing Fire Bucket dry sand, 10 Ltrs cap, confirming to IS 2546.
Sch A Part XVIII (Manning and operation of lift, DG Set, LT Panel, Pump Set etc and other electrical equipment during Defect Liability period)
Manning & operation of the following installation by providing 01 Lift attendant/semiskilled staff in each shift (8 hours in each shift) including sunday and closed holidays for smooth operation of installations :- a) DG Set 50 KVA - 01 No b) Lifts - 02 Nos c) Booster Pump-02 Nos d) 2 HP pump set - 02 Nos e) LT Electric panel-04 Nos Note : (i) The above manning and operation shall be carried out in three shift of 08 hours each per day including Sunday and Holyday with 01 Lift attendant/ semiskilled for the period of 2yrs of defect liability.
For first year during DLP (For 330 days)
For second year during DLP (For 330 days)
For balance 70 days during DLP
Sch A Part XIX (Manning and operation of lift, DG Set, LT Panel, Pump Set etc and other electrical equipment after Defect Liability period)
Manning & operation of the following installation by providing 01 Lift attendant/semiskilled staff in each shift (8 hours in each shift) including sunday and closed holidays for smooth operation of installations :- a) DG Set 50 KVA - 01 No b) Lifts - 02 Nos c) Booster Pump-02 Nos d) 2 HP pump set - 02 Nos e) LT Electric panel-04 Nos Note : (i) The above manning and operation shall be carried out in three shift of 08 hours each per day including Sunday and Holyday with 01 Lift attendant/ semiskilled for the period of 1st year to 3rd year after defect liability period.
For first year After DLP (For 330 days)
For second After year DLP (For 330 days)
For Third After year DLP (For 330 days)
For Third year after DLP balance 105 days
Sch A Part XX (PRIME COST SUM FOR MODULAR KITCHEN)
Lump sum price worked out by the contractor for Prime Cost Sum for Modular kitchen work as per latest norms and standard. Estimated cost for modular kitchen inserted by MES = Rs 11,00,000.00. Note :- The amount to be quoted by the Tenderer in BOQ against the inserted price by the department shall be restricted to Maximum 15% over and above the prime cost sum, accordingly the tenderer shall quote the amount.
Deduct schedule of credit of (-) Rs 206121.00 (Minus) as brought out from credit schedule of tender
MAGO CONSTRUCTION PVT. LTD. (BID ID -3272010)
SNG BUILDERS AND ENGINEERS (BID ID -3272059)
ATUL CONSTRUCTION CO. (BID ID -3269483)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid