| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹7.0 L+₹57,415 (8.94%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹8.3 L+₹1.9 L (29.6%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
13 Jun 2024, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 054
REPAIR TO GEYSERS, CEILING FAN, EXHUAST FANS WALL MOUNTING FANS AND CONNECTED WORKS IN TECHNICAL AREA AND RESIDENTIAL AREA AT CVRDE AVADI
2024_MES_653599_1
8618/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹18,000
Yes
2 Sept 2024
11 May 2024
15 Jun 2024
11 May 2024
13 Jun 2024
25 May 2024
Amount
Taking down ceiling fans of any make and sweep from any height of the building after disconnection of all electrical connections and fixing back the same in position, connecting up complete after carrying out servicing/ repair etc all as specifed and directed. Note M&L for Repair/ replacement of parts shall be measured & paid separately under relevant items.
Dismantling of ceiling fan 1200/1400mm sweep of any make and taking out existing burnt winding and rewinding the with the super enamelled copper wire of existing size/gauge including providing of insulating material, bearing, bush, greasing, varnishing and properly packing of winding, assembling and testing complete all as specified and directed.
Supply and fix in repair fan condensor 1.6 to 2.5mfd 230/440V range 50Hz complete all as speciefed and directed.
Supply and fix in repair heavy duty PVC top and bottom canopy set of ceiling fan complete all as specifed and directed.
Supply and fix down rod of 36 Inch length 15 mm dia made out of GI/mild steel pipe/ERW suitable for ceiling fan of any make with incl hanging clamps, real rubber with nut and bolt at top, split pins at bottom all as specifed and directed
M & L for preparation surfaces of ceiling fan complete including fan blades, clamps and hanging rod etc by scraping existing paint care fully and applying two coats of spray painting with synthetic enamel paint including filling cavities with filler coat after cleaning of dust etc including writing the MES No with black paint of existing size all as directed by Engineer-in-charge.
Taking down Exhaust fans of any make and sweep from any height of the building after disconnection of all electrical connections and fixing back the same in position, connecting up complete after carrying out servicing/ repair etc all as specifed and directed. Note M&L for Repair/ replacement of parts shall be measured & paid separately under relevant items.
Dismantling of exhaust fan, 300 mm sweep of any make, taking out existing burnt winding and rewinding the motor with super enamelled copper wire of existing size/gauge, bearing including provision of insulating material, varnishing and properly baking of winding, re-assembling and testing complete all as specified and directed.
All as per item No 08 above, but for exhaust fan 350 mm /380 mm sweep of any make -ditto-.
All as per item No 8 above, but for exhaust fan 450 mm /600mm sweep of any make -ditto-.
Material & labour for replacement of condenser / capacitor of capcity 4 MFD including connection suitable for exhaust fan of any make and sweep all as directed by Engineer-in-charge.
S&F in replacement of exhaust fan blade made out of MS sheet (as per existing shape and size) complete all as directed
S & F of canopy of motor (back cover) made out of MS sheet of 1.6mm thick including stainless steel screws, suitable for exhaust fan of 300/350/380/450 mm sweep of any make complete all as specified directed.
M & L for preparation of surface of exhaust fan of any make and sweep complete including body, blades, legs etc by scraping of existing paint carefully, filling cavities with filler coat after cleaning of dust etc and applying two coats of spray painting with synthetic enamel paint of colour as approved including writing the MES No/ Srl No with black paint all as directed.
M & L for replacement of louver suitable for upto 450 mm sweep exhaust fan complete all as speciefed and directed.
All as per item Sl No 01 above but for Air circulated fan any sweep.
M&L of wall mounted air circulator of 400/600mm sweep, burnt winding and rewinding the motor with super nameled copper wire of existing size/gauge including providing bearing insulating material, varnishing and properly baking of winding, assembling and testing the same for full speed up to the entire satisfaction of Engineer-in-charge.
Supply and fixing in replacement of flexible PVC insulated copper conductor cable, twin core of size 23/.0076 for connecting lead from ceiling rose to condenser/connectors complete all as specified and directed by Engr-in-Charge.
M&L for DOL starter suitable 415V, 1-5A rating complete all as specifed and directed.(For Exhaust fan HD 415V)
Taking down carefully storage type water heater (geysers ) of 25/50 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing/cutting of holding bolts/nuts from walls and opening the tank for repair including Inspection and Refixing after repair and testing of repaired geysers (of any type and capacity) due to any defect like air lock, water leakage in pipe line joints including replacement of GI nipples, and replacement of small electric parts like indication lamp, fusible plug, checking loose electric connections inside and outside geyser and making good the disturbed surfaces complete all as specified and directed. Note :- (a) Cost of mentioned small parts like GI Nipple, Fusible plug, indication lamps and steel Fastners of size 10mm dia 100 mm long wherever required will be included in the quoted rate. (b) Any major parts like Assembly, element, Thermo state, PVC connections etc will be measured and paid under separately.
Supply and fixing (in repair ) inner assembly suitable for 25 Ltr of capacity geyser complete all as per IS Codes and specified and directed by Engineer-in-charge.
Supply and fixing (in repair ) inner assembly suitable for 50 Ltr of capacity geyser complete all as per IS Codes and specified and directed by Engineer-in-charge.
Supply and replacing flexible PVC connection, heavy duty, 450/600 mm long with CP brass adopter and washers at both ends suitable for hot water for 15mm dia pipe all as specified & directed
Supply only thermo start suitable for 25/50 ltr geyser capacity to control water temperature 20 degree C to 80 degree C, ISI marked complete all as specified & directed
Supply and fixing in replacement Heating element 1.5 KW, 230 volts AC supply (ISI marked, original as per existing/sample) suitable for water heaters/geysers (any type) complete with rubber gasket including replacing the rusted bolts/screw if required during changing the heating elements, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement Heating element 2 KW, 230 volts AC supply (ISI marked, original as per existing/sample) suitable for water heaters/geysers (any type) complete with rubber gasket including replacing the rusted bolts/screw if required during changing the heating elements, complete all as specified and as directed by Engineer-in-charge.
Taking down electric water heaters (geysers ) of capacity 50 Ltrs, storage type from site, after diconnecting of electric and water connections, taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly carefully, replacement of inner shell (Stainless steel tank) and refixing the thermostate switch, geyser element and geyser assembly, testing the inner tank for any leakages, Re-assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete to the entire satisfaction of the Engineer-in-charge. Note :- Cost of the glass wool required to be replaced in the inner shell of geyser will be included in the quoted rate no extra payment will be given.
Taking down electric water heaters (geysers ) of capacity 25 Ltrs, storage type from site, after diconnecting of electric and water connections, taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly carefully, replacement of inner shell (Stainless steel tank) and refixing the thermostate switch, geyser element and geyser assembly, testing the inner tank for any leakages, Re-assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete to the entire satisfaction of the Engineer-in-charge. Note :- Cost of the glass wool required to be replaced in the inner shell of geyser will be included in the quoted rate no extra payment will be given.
Supply and fixing (in repairs) Autocut with temperature control regulator/thermostat with relay of suitable size on site, suitable for any make & type of geyser 25/50 Litres capacity horizontal or vertical type all as specified and directed.
S & F in replacement top plug 15/16 Amp size complete all as directed by Engineer-in-charge.
Supply and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required
(b) 15/16 A Switch
(d) 6 Pin 15/16 amps socket outlet
Supply and fixing 3 Module (100 mm X 75 mm) GI box along with modular base & cover plate for modular switches in recess etc as required.
Supply and fixing 1 or 2 Module (75 mm X 75 mm) GI box along with modular base & cover plate for modular switches in recess etc as required.
Wiring for circuit/submain wiring with 2 X 4.0 Sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 X 4.0 Sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and Fixing MCB Single Pole (SP) 5 A to 32 A rating 240 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and Fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supply and Fixing 20 Amps, 230 V SPN industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 20 Amps "C" curve SP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required.
SARAVANA ENTERPRISES
EASHWAR ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .