| 1 | L1₹23.5 LAccepted-AOC WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | L1 | Accepted-AOC Lowest bidderr | |
| 2 | L2₹33.0 L+₹9.1 L (38.4%)Rejected-Finance RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L2 | Rejected-Finance Other than Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
28 Oct 2021, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR AND REPLACEMENT OF DEFECTIVE SPARE OF EFFLUENT TREATMENT PLANTS, FUME SUCTION PLANT, HOT WATER GENERATOR, CAR WASHING PLANT, DEGREASING PLANT AND HULL PAINTING PLANT LOCATED IN DELHI CANTT UNDER GE (U) P AND M DELHI CANTT.
2021_MES_478959_1
GE(U)/PM/D-40/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted under class D category c(iii) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹92,000
Yes
27 Nov 2021
30 Sept 2021
30 Oct 2021
30 Sept 2021
28 Oct 2021
14 Oct 2021
Amount
Draining and cleaning of alkaline chamical tank ,Hot water tank, Cold water tank in installed basement of de-greasing palnt and 05 Nos of ETP tank complete and removing frozen solid sludge from all tank in each month. Solid sluge and other wastage should be disposed / thrown at a minimum distance of 100 metre away from the plant or a location decided by users with in the 505 ABW premises complete all as specified and directed by Engr-In-charge. details of Tank - (a) 05 ETP tank ( Clean in each Month) Total - 5 x 6 (month ) = 30 month (b) 03 Tank (Alkaline Tank-01, Hotwater Tank-01, Cold Water-01) Total = 3 x 3 (clean the tank once in 02 month) = 9 Month G total - 30+9=39 Month
M&L for cleaning and repairing of all spray pipe lines of various size, laying on the floor inside the de-greasing washing chamber plant for alkaline chemical and Hot/cold water pumping through this pipe and connceted nozzels complete, dismatling / open the oulet valve of pipe or nozzle including coupling with packing near joining the pipe complete drain out any remaining frozen materials inside the pipe line and nozzels, making good any leakage in pipe line with necessary gas cutting, welding , polishing, testing as per site requirement complete all as specified and directed by Engr-In- charge.
M&L for overhauling of squirrel cage induction electric motor 3 phase 415 volts , 1455 RPM of capacity 60 HP/45KW with pump set complete cleaning the impeller and dischage /suction casing of the pump including repairs to pump complete with dismantling and re-assembly and testing complete all as specified and directed by Engr-In-charge. NOTE: Rewinding of motor by super enamelled copper wire with class F insulation necessary disconnecting electric connections/ taking down and shifting to local workshop and brought back to site complete reassembled as per existing location . Lubrications oils and apply greasing to all moving parts. Repair/replacement, retrofit ,of all major/ minor parts i.e rotor,stator,winding,terminal box ,bearing, shaft , Fan, impeller , gland assembly, bearning assembly , coupling,Contact Terminals and checking and replacing the burnt cable glands and cunsumable items complere as requirement for smooth functioning of motor & pump set ,all materilas are deemed to be include in the quoted rate by the contractor all as specified and directed by Engr-in-Charge.
All as per srl item No 03 here-in-before but motor of capacity 12.5 HP complete all as specified and directed by Engr-In-charge.
All as per srl item No 03 here-in-before but motor of capacity 7.5 HPcomplete all as specified and directed by Engr-In-charge.
All as per srl item No 03 here-in-before but motor of capacity 5.0 HP complete all as specified and directed by Engr-In-charge.
All as per srl item No 03 here-in-before but motor of capacity 3.0 HP complete all as specified and directed Enginer-in-charge.
All as per srl item No 03 here-in-before but motor of capacity 0.5 HP complete all as specified and directed by Engr-In-charge.
M&L for overhauling of fume exahuast blower with electric motor 3 phase 415 volts , of capacity 5HP mounted on roof of degreasing washing plant complete dismantling from duct and after make a good connecting the blower with suction/delivery duct complete reassembling and reinstalling ,testing the same to its orginal position complete all as specified and directed by Engr-In-charge. NOTE: Rewinding, dismantling and reassembly, Lubrication, gressing to all moving parts and repair/replacement of all major/ minor parts are deemed to be included in the rates quoted by the contractor.
Taking down complete and supply & fixing in replacement of centrifugal air blower with motor of capacity 5 HP, 3P,415 Volt including complete fitting with existing suction / delivery duct necessary retrofit as per site requirement complete all as specified and directed by Engr-In-charge. (Make- Kirloskar/ Crompton /GEC)
Supply & Fixing in replacement pneumatic time relay 0-60 sec complete all as specified & directed by Engr-in-Charge. (Make : KRTPN10-1 of BCH or equivalent in L&T)
Supply & Fixing in replacement foot valve heavy duty of size 50mm complete all as specified and directed by Engr-in-Charge : (Make : Zoloto/Kirloskar/ Leader/ AUDCO)
Supply & Fixing in replacement foot valve heavy duty of size 40 mm complete all as specified and directed by Engr-in-Charge : (Make : Zoloto/Kirloskar/ Leader/ AUDCO)
Supply & Fixing in replacement AC induction tubular heater 9 KW, 415 volts, 3 phase of length 1.5 m length or as per sample with MS powder coated terminal cover as per sample complete all as specified and directed by Engr-in-Charge. (Make - Telelec/Escort/USGC/Theeta).
Supply and fixing industrial heating element capacity of 9 KW ,3P,415 volt, L shape , 2.6 Mtr length or as per sample with MS powder coated terminal cover as per sample complete all as specified and directed by Engr-in-Charge. (Make Escort/Theeta/Spotheat)
Supply & Fixing in replacement 3 pole power contactor 32 Amps type ML2 with 2NO+2NC complete all as specified and directed by Engr-in-Charge. (Make :L&T /Siemens/Legrand/ABB)
Supply & Fixing in replacement contactor MNX 18 415V AC3 complete all as specified & directed by Engr-in-Charge. Make : L&T/ Siemens / Legrand/ABB)
Supply & Fixing in replacement contactor MNX 25 415V AC3 complete all as specified & directed by Engr-in-Charge. Make : L&T/ Siemens / Legrand/ABB)
Supply & Fixing in replacement 3 pole power contactors type MNX 70 with 2NO+2NC complete all as specified and directed by Engr-in-Charge. (Make : L&T Siemens/Legrand/ABB/BCH )
Supply & Fixing in replacement 3 pole power contactor 140 Amps type MNX 140 with 2NO+2NC complete all as specified and directed by Engr-in-Charge. (Make : L&T Siemens/Legrand/ABB/BCH )
Supply and fixing in replacement digital temperature indicator 6100 as per sample complete fitting and necessary wiring as per existing panel complete all as specified and directed by Engr-In-charge. (Make. Audiotronics or equivalent )
Supply and fixing in replacement of thermostat 72" long including elecrical connection complete for suitable to hot water tank as per sample complete all as specified and directed
Supply and fixing in replacement of stainless steel water Spray Nozzels 16LPM; 1/2 BSP with necessary gas cutting, welding , polishing, testing as per site requirement complete all as specified and directed by Engr-in-Charge. (Make : as per sample)
Supply , installation, commissioning, testing in replacement of centrifugal monoblock Pump set of capacity 7.5 HP,3000 RPM, 3 Phase 415 Volt with IP-44 protection including mounting ,foundation and making good complete all as specified and directed by Engr-in-Charge. (Make : Model No KDS852 of Kirloskar or equivalent in Crompton / Beacon/ KSS)
Supply , installation, commissioning, testing in replacement of centrifugal monoblock Pump set of capacity 3.0 HP,3000 RPM, 3 Phase 415 Volt with IP-44 protection including mounting ,foundation and making good complete all as specified and directed by Engr-in-Charge. (Make : Model No KDS325 of Kirloskar or equivalent in Crompton / Beacon/ KSS)
Supply and fixing in replacement of Exhaust fan heavy duty of size 600mm sweep of 900RPM, 3 Phase, 415 Volt, 50 Hz AC with metal body including all accessories, connections, testing, assembling and making good to disturbed surfaces of wall including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make: Model Turbo Force SP of Havells or equivalent in Bajaj/Philips/ Crompton Greaves)
Supply and fixing in replacement of Drain Pump(ss304) with Motor 1 HP, complete all as specified and directed by Engineer-in-Charge. ( Make: KSB/Kirloskar/Grundfos )
M&L for replacement of electro Hydraulic thrustor brake 18kg type MDT150-18 complete all as specified and directed by Engr-in-Charge. (Make- USGC or equivalent to Speedage/ Speed-O-Controls)
M&L for replacement of elctro Hydraulic thrustor 18kg 3 phase 415V AC type ST-520 complete all as specified and directed by Engr-in-Charge. (MakeUSGC or equivalent to Speedage/Speed-O-Controls )
Supply & Fixing in replacement MCB 3 pole, 415V AC, 25 Amp rating 16 KA rupturing capacity thermal magnetic release along with any retrofit work complete all as specified & directed by Engr-in-charge (Make : L&T /Siemens/Legrand/ABB)
Supply & Fixing in replacement MCB 3 pole, 415V AC, 32 Amp rating 16 KA rupturing capacity, thermal magnetic release along with any retrofit work ,thimbles, gland as per requirement in existing panel complete all as specified and directed by Engr-In-charge. (Make : L&T /Siemens/Legrand/ABB)
Supply & Fixing in replacement MCB 4 pole, 415V AC, 32 Amp rating 16 KA rupturing capacity, thermal magnetic release along with any retrofit work thimbles, gland as per requirement in existing panel complete all as specified and directed by Engr-In-charge. (Make : Legrand/Schneider/L&T/ABB)
Supply & fixing in replacement 3 core 2.5 Sqmm PVC insulated & round sheathed bright annealed copper conductor flexible cable for voltage grade 1100 V as per IS: 694 complete all as specified & directed by Engr-in-charge (Make : Finolex/ Polycab/Kalinga/ Havells)
Supply & fixing in replacement 3 core 6 Sqmm PVC insulated & round sheathed bright annealed copper conductor flexible cable for voltage grade 1100 V as per IS: 694 complete all as specified & directed by Engr-in-charge (Make : Finolex/ Polycab/Kalinga/ Havells)
M&L for Servicing of Hull pulling gear box of ratio 70:1 type 400 with taking out gears , rope drum with rope & replacement of gear shaft , locks , gasket set,nuts & bolts top up gear oil of standard grade , greasing, replacing defective control panel and accessories and also Rates to include replacement of minor spares (control copper wiring, aluminium lugs, nut bolts and cosumable items) complete all as specified and directed by Engr-In-charge. Note:- The rates for fixing of items as mentioned in BoQ Srl item Nos 36 to 38 here-in-after is deemed to be included in the quoted rates.
Supply only of gear bearing with coupling suitable for winch pulling gear box as per sample of existing size complete all as specified and directed by Engr-In-charge. (Make:- SKF/TATA/NBC )
supply only steel wire rope size of 16 mm FMC construction 6 x 36 ungalvanised as per IS 2266/02 complete all as specified and directed by Engr-In-charge. (Make:- Usha Martin/fort william)
Supply only rotary type limit switch RG/LS/4C , suitable for gear ratio 70:1 with 2 NO + 2 NC complete all as specified and directed by Engr-In-charge. (Make USGC/Speedage/ Speed-o-control )
Supply and fixing in replacement of Switch disconnector fuse TPN with HRC fuse and handle open execution type of size 250 Amp complete all as specified and directed by Engr-In-charge. (Make- L&T/BCH/GE/Siemens)
Supply and fixing in replacement of Switch disconnector fuse TPN with HRC fuse and handle open execution type of size 160 Amp complete all as specified and directed by Engr-In-charge. (Make- L&T/BCH/GE/Siemens)
Supply and fixing in replacement of Switch disconnector fuse TPN with HRC fuse and handle open execution type of size 100 Amp complete all as specified and directed by Engr-In-charge. (Make- L&T/BCH/GE/Siemens)
Supply and fixing in replacement in over load relay rating 30-50A suitable for MNX contactor mounting , including necessary wiring as per site requirement complete all as specified and directed by Engr-in-Charge. (Make :- Schneider/L&T/Siemens/ Legrand/ABB)
Supply and fixing in replacement thermal over load relay rating 14-23 A suitable for MNX contactor mounting including necessary wiring as per site requirement complete all as specified and directed by Engr-in-Charge. (Make :- L&T/Siemens/speedage/GE/BCH)
Supply and fixing in replacement t thermal over load relay rating 9-15 A suitable for MNX contactor mounting including necessary wiring as per site requirement complete all as specified and directed by Engr-in-Charge. (Make :- L&T/Siemens/speedage/GE/BCH)
Supply and fixing in replacement over load relay of 5.5-8 Amp type LRE-12 complete all as specified and directed by Engr-in-Charge. (Make :- L&T/Siemens/speedage/GE/BCH)
M&L for replacement of Floating shaft made out of M.S. EN8 material medium carbon steel of Cylindrical shape of size100mm dia and 1.80mtr length and shaft end both side machining with keyway slot as per sample weight approx. 110.98kg complete all as specified and directed by Engr-In-charge. (Make –Speedage/USGC/ Speed-O-Controls)
Supply and fixing in replacement of Bib cock 15mm in filter press madeout of Gun metal/Brass with necessary connections as per sample complete all specified and directed by Engr-in-Charge. (Make- Sant/Zoloto/Rotex)
M &L for overhauling of helical rotor pump /chemical pump series RN with replacement of oil seal and ball bearing minor / major parts complete all as specified & directed by Engr-in-charge. (Make : Roto)
M&L for Servicing of Pneumatic Solenoid drain Valves of size 100/150 NB i.e Cleaning checking for wear and tear, checking electrical termination, testing and breakdown maintenance and replacement of unserviceable parts if any required for smooth functioning of the valve complete all as specified and directed by Engr-In-charge. Note:- (i) The scope of work includes all repair / replacement of unserviceable parts included in the quoted rate by the contractor all as specified and directed. (Make :- Rotex/trident/Aira)
Supply and fixing in replacement of Pneumatic Solenoid valve 50NB with Air Pipe & Pipe connected accessories complete all as specified and directed by Engr-in-Charge. (Make-Rotex/Trident/Aira (Model ECF50))
Taking down and supply & fixing in replacement of CI butterfly ball valve 50 MM dia with hand operated fiiting in existing location complete all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of defective push button in Green/Red colour for suitable ON/OFF to motor complete connection in existing panel complete all as specified and directed by Engr-In-charge.
Taking down and supply & fixing in replacement of defective phase indication lamp RYB with wiring complete as per requirement of existing panel complete all as specified and directed by Engr-In-charge.
Dismantling / taking down defective & rusted pH controller with accessories and supply & fix pH controller with new SS enclosure outdoor type and wiring with copper cable not less than 1.5 sqmm ,complete all as specified & directed by Engr-in-charge (Make: Nutronix/Omega/SB enternational)
M&L for Sevicing of centrifugal floor mounted ID (Induced Draft) Fan of capacity 36000 CFM , V belt driven for ventilation system make of IEPL including their connected accessories complete for smooth functiononing with re-assembly and testing complete all as specified and directed by Engr-In-charge. NOTE: (a) Servicing to by done by auth service team. (b) Cleaning and inspect all component part of ID fan i.e vibration checking, fan housing, fan balancing & vabration analysis, Nut & Bolt proper tighting,suction pressure,abnormal noise, V belt correctly aligned and properly streched, clean disassembled part complete. (c) Lubrication and greasing all movable parts i,e bearing shaft, (d) Repair/replacement of V belt, roller bearing block , shaft ,V belt , in/out duct , MS 20mm round bar studs of length 60cm 4 Nos to hold the blades firmly with welding, brazing parts required for smooth functioning of ID fan complete to included in the quoted rate by the contractor all as specified and directed by Engr-in-Charge
M&L for Servicing of centrifugal floor mounted FD (Forced Draft) Fan of capacity 40000 CFM , V belt driven for ventilation system make of IEPL including their connected accessories complete for smooth functiononing with re-assembly and testing complete all as specified and directed by Engr-in-Charge. NOTE: (a) Maintnance to be done by auth service team . (b) Cleaning and inspect all component part of ID fan i.e vibration checking, fan housing, fan balancing & vibration analysis, Nut & Bolt proper tighting,suction pressure,abnormal noise, V belt correctly aligned and properly streched, clean disassembled part complete. (c) Lubrication and greasing all movable parts i,e bearing shaft, (d) Repair/replacement,retrofit of Fan blade , fan V belt, roller bearing block ,Shaft, V belt , in/out duct , MS 20mm round bar studs of length 60cm 4 Nos to hold the blades firmly with welding, brazing parts required for smooth functioning of ID fan complete. The rates quoted by the contractor shall include all the above points.
M&L for overhauling of squirrel cage induction electric motor 3 phase 415 volts , 1475 RPM of capacity 30 HP/22KW make of CG complete with re-assembly and testing complete all as specified and directed by Engr-In-charge. NOTE: Rewinding by super enamelled copper wire with class F insulation necessary disconnecting electric connections/ taking down and shifting to local workshop and brought back to site, dismantling and assembly, Lubrications oils and apply greesing to all moving parts and repair/replacement of all major/ minor parts i.e rotor,stator,winding,terminal box ,bearing, shaft , Fan items as required to make motor smooth functional shall deemed tobe included in the rates quoted by the contrator.
Supply and fixing in replacement of paint spray guns HPLV Type - 59 or as per sample suitable for mannual painting and flexible PVC pipe heavy duty ISI mark not less than 15mm bore ,6 Mtr long complete all as specified and directed by Engr-In-charge. (Make : Bullows /Giraco/Ransburg/AP&T or equivalent to ISI mark)
Material & Labour for replacement floor paint filter size 630 x 650 x 50mm Mat Type – Class ‘A’ Glass Fiber Grade : G3 (EN779) Color : Green + White Thickness : 50 mm Weight : >250g/m2 Paint Hold Capacity : 2450 g/sqm Avg. Paint Arrest : 92% Rated Air Flow : 0.65 cum/sec Media Velocity : 2.5 m/sec Initial Temp Resistant : Up to 177 Degree ‘C’ Flame Resistant : Non Flammable complete with removal of old filter from floor after carefully taking out MS grating, removal of old filter and cleaning filter frame, replace filter media, refixing grating complete all as specified & directed by Engr-in-charge. (Make : Automative solution/Environmental Engineering Co/Athlete)
Material & Labour for replacement of ceiling Air Filter Type : Progressively Structured , Polyester Thermally Bonded Impregnated, Grade : F5 (EN779) Thickness : 22 mm ,Weight : 600g/sqm Dust Hold Capacity : 437g/sqm Avg. Dust Arrest : 94% Rated Air Flow : 900cum/hr Media Velocity : 0.25m/sec ,Temp Resistanto 100 Degree complete with removal of old filter from ceiling after carefully taking down ceiling support and refixing after replacement of filters complete all as specified and directed by Engr-in-Charge. (Make : Automative solution/Environmental Engineering Co/Athlete)
Material & Labour for replacement Pre Filter of size 600mmx600mmx50mm, 10 micron filtration level , velocity 2.6m/sec, min dust levelling 500g/m2 , constructed with several layer of HDPE mesh stiched together synthetic micro fibre with support of aluminium expended metal layer complete all as specified and directed by Engr-In-charge. (Make . Automative solution/Envirnmental Engineering Co)
Material & Labour for replacement fine filter of size 600mmx600mmx150mm woven synthetic media housed in GI wire mesh capacity of dust filtration up to 99% efficiency, the complete housing shall be fabricated out of 16 gz GI sheet,and double skinned insulation complete all as specified and directed by Engr-In-charge. ( Make : Automative sulution/Envirnmental Engineering Co/Athlete)
M&L for overhauling compressor unit 9 KG/ Sqcm with repalcement of compressor oil , air oil separator, oil filter primary and secondary, safety valve assembly, non return valve assembly, gasket set, fan belts, nuts & bolts, air pressure valves, complete itmes for smooth functioning of compressor included in quoted rate by the contractor complete all as specified and directed by Engr-In-charge. (Make:-ELGI )
Supply & fixing in replacement of defective AC heating elements 6 KW, 415 volts, 3 phase of length 610mm complete fitting as per existing loaction complete all as specified and directed by Engr-In-charge. (Make Telelec/Escorts/Theeta)
Supply and fixing in replacement of MCCB 4 pole, 415V AC, 250 Amp rating 36 KA rupturing capacity, thermal magnectic release, complete with any retrofit work, terminal links with thimbles, gland as per requirement in existing panel complete all as specified and directed by Engr-In-charge. (Make : Legrand/Schneider/L&T/ABB)
Supply and fixing in replacement of MCCB 3 pole, 415V AC, 100 Amp rating 25 KA rupturing capacity, thermal magnectic release, complete with any retrofit work, terminal links terminal links with thimbles, gland as per requirement in existing panel complete all as specified and directed by Engr-In-charge. (Make : Legrand/Schneider/L&T/ABB)
Supply and fixing in replacement of MCCB 3 pole, 415V AC, 125 Amp rating 36 KA rupturing capacity, thermal magnectic release, complete with any retrofit work, terminal links terminal links with thimbles, gland as per requirement in existing panel complete all as specified and directed by Engr-In-charge. (Make : Legrand/Schneider/L&T/ABB)
Supply and fixing in replacement of 04 x LED panel light of 36 watt Weather and Water proof (600mm x 600 mm Square PL Armstrong quadra series) with cabling to be done through SS Capping Argon Welded with SS walls of the washing chamber suitable to the existing site with all fixing accessories complete all as specified and directed by Engr-in-Charge. (Make: Syska SSK-PL-36WSQ 5.7K or equivalent in Bajaj/ Phillips/ Havells)
M&L for defective Rail track on floor mounted of hull painting trolly make good or joining ,align the defective Rail track with the help of metal fishplates/joint bar pieces including necessary holes ,welding and tightening with nut, bolt, washer as per requirement at site for smooth fucntioning of trolly on track complete all as specified and directed by Engr-In-charge. Note: Earth work and PCC for necessary requirement of resurfacing around the defective area of track the cost of all materails are deemed to be include complete materails rate include in the rate quoted bt the contractor.
Taking down and M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized earth strip 32x6mm connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 40mm dia GI pipe medium grade for earth strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for entering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion complete all as specified and directed by Engr-In-charge.
M&L for taking out motor from 15HP ,1400 RPM blower set and rewinding of electric motor squirrel cage induction 15 HP, 1400 RPM, 415 Volts 3 Phase, 50 Hz with super enamelled copper wire of superior quality as per existing guage including varnishing, insulating material including reassembling fixing with suction & dischage duct in position making connection testing and commissioning & complete all as specified & directed by Engr-in-charge
All as per srl item No 72 here-in-before but blower motor of capacity 10 HP complete all as specified and directed Enginer-in-charge.
Supply and fixing in replacement of defective SS round grade 304 of size 25x 5300mm by grouting in earth by holding clamp including cutting and welding complete all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of defective hull resting trolly wheel OD 410mmx95mm and wheel collar thickness 15mm and depth of collar 25mm and wheel centre bored 60mm with key slot with six no supporting rives made out of M.S forging /M.S casting E.N.8 materrial as per directed by Engr-in-charge (Make: ISI Marked).
Supply & Fixing in replacement MCB 3 pole, 415V AC, 63 Amp rating 16 KA rupturing capacity, with any retrofit workcomplete all as specified & directed by Engr-in-charge . (Make : L&T /Siemens/Legrand/ABB)
Taking down complete and Supply & fix in replacement gun metal vertical NRV 40 mm heavy duty complete fitting all as specified & directed by Engr-in-charge. (Make : Prince/sant/Kirloskar)
Servicing of servo voltage stablizer of capacity 100 KVA 415 Volt ,50Hz of make VOLINA disconnecting of all electrical connections of stabilizer and check the auto/manual function of stabilizer, to be check the oil level, oil seals leakage if any, check all volt meters and amp meter working condition or not, Taking out top cover of stabilizer for replacing defective parts/items clean the dust by air blower, check the neutral and earthing connections properly or not, to be done properly, to be check the all nut bolts tightining. and refixing, the same in existing location, and re connect all the incoming/outgoing cables properly including testing and commissioning complete all as specified and as directed by Engr- in- Charge. Note: (i) Spares parts if required shall be measured & paid separately as ‘supply only’ under relevant items. (ii) Labour charge for ‘supply only’ materials are deemed to be included in the quoted rate by the contractor.
Supply only servo card as per sample
Supply only Ampere meter with C.T (Digital/analog) including necessary connection controlling switches complete (suitable size of shape) complete all as specified and directed by Engr-In-charge.
Supply only voltmeter 0 to 440 volts flush type including necessary connection controlling switches complete (suitable size of shape) complete all as specified and directed by Engr-In-charge.
Supply only Servo motor 3 K.G. torque single phase complete all as specified and directed by Engr-In-charge.
Supply only Rotary switch 5 Amp for R. Y. B phase complete all as specified and directed by Engr-In-charge.
Supply only trigger transformer complete all as specified and directed by Engr-In-charge.
Supply only Port meter complete all as specified and directed by Engr-In-charge.
Supply only Auto manual switch complete all as specified and directed by Engr-In-charge
Supply only P.C.B Holder complete all as specified and directed by Engr-In-charge.
Supply only Contactor strip complete all as specified and directed by Engr-In-charge.
Supply only Indicator light complete all as specified and directed by Engr-In-charge.
Supply only of dimmer coil 60 amp complete all as specified and directed by Engr-In-charge.
Supply only of Main Transformer 100 KVA complete all as specified and directed by Engr-In-charge.
M&L for replacement of damage chemical filter jacket made out of 3mm SS sheet of size 800mm x490mm or as per existing sample / model . Jacket holding flange s.s round on the upper side of size 40mm x 3mm along with suitable size mounting holes /liftinghook. Wiremess of nominal dia 0.56mm and apperture 1.18mm bend into shape for fixing in side in jacket complete fitting all as specified and directed by Engr-In-charge. (Make:- HS engineering works/USGC/Premerue)
Material and labour for Dismantling carefully of squirrel cage induction electric motor three phase 415 volts ,1410 RPM of capacity 1 HP/0.75 KW taking out the burnt/worn coils from the slots of stator and other accessories such as ball bearing and rotor and cleaning the stator slots and rewinding the same with new super enamelled copper winding with existing gauge, and , varnishing with doctor beck's insulating varnish and re-assembling the same and testing comissioning complete all as specified and directed by Egr - in - Charge.
Supply and fixing in replacement of power contactor 3 phase MNX series type or as per existing sample / model of rated capacity 6 Amp to 9 Amp 415volts along with suitable rating of NC/NO type Auxiliary contactor block complete all as specified and directed by Engineer -in-Charge. (Make : MEC/BCH/ ABB/ L&T /Siemen/Schnieder/C&S)
Supply & Fixing in replacement MCB SP 32 Amp , 16 KA,230 Volts complete with any retrofit work complete all as specified & directed by Engr-in-charge. . (Make : L&T /Siemens/Legrand/ABB)
Supply and fixing in replacement of rubber gasket of size 60mmx5mm mounted on hull painting sliding gate by adhesive with flap on both sides along the length of size 3370mm gate complete all as specified & directed by Engr-in-charge.
Supply and fixing in replacement of MCCB 3 pole, 415V AC, 200 Amp rating 35/36 KA rupturing capacity, thermal magnectic release, complete with any retrofit work, terminal links with thimbles, gland as per requirement in existing panel complete all as specified and directed. (Make : Legrand/Schneider/L&T/ABB)
M & L of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc using 32 x 6mm galvanised iron strip complete all as & specified & directed by Engr-in-charge.
Supply and fixing in replacement of defective Car wash Brush suitable for existing automatic car washing plant or as per sample complete all as specified and directed. (Make - as per ISI mark )
Supply and fixing in replacement of Brush Rivite for suitable for automatic car washing brush or as per sample complete all as specified and directed. (Make - as per ISI mark )
Supply and fixing in replacement of DOL starter 3 Phase 415 volt suitable for 3.0 HP pump set complete all as specified and directed. (Make:- L&T/schneider/seimens)
Supply and fixing in replacement of MCCB 4 pole, 415V AC, 200 Amp rating 35/36 KA rupturing capacity, thermal magnectic release, with SS enclosure box any retrofit work, terminal links with thimbles, gland complete all as specified and directed. (Make : Legrand/Schneider/L&T/ABB)
Supply and fixing in replacement of defective detergent pump capacity as per sample for car washing plant all as specified and directed by Engr-in charge (Make:- KRE or equivalent as per ISI mark )
BUSINESS TEK INDIA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .