Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.9 L+₹11,661.90 (0.34%)Rejected-AOC 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L2 | Rejected-AOC L2 | |
| 3 | L3₹36.6 L+₹1.8 L (5.25%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 | |
| 4 | L4₹40.0 L+₹5.2 L (15.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹41.1 L+₹6.4 L (18.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | devan enterprises L3 | chowdeshwariconstructionco L5 | Sanidhya Enterprises L4 | Lucky Enterprises L6 | ADR ENTERPRISES L2 | SRINIDHI DIESELS & ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Servicing of DG Set 250 KVA , checking Comprising of A , B and C checks at regular intervals for entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly , air cleaner assembly, lubrication oil hose flexible pipe , hose turbo etc and replacing the same with same size , make and capacity of parts . Cleaning all the serviceable filters with cleaning solution such as petrol and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil grade 15W/40 upto required level and including testing to DG Set complete all as specified and directed.
Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items Sr No 1.1 to1.5. (b) Servicing will be carried out through authorized service engineer of OEM .
(c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor. | 3 | Job | 20,000 ₹60,000 | 16,000 ₹48,000 | 16,500 ₹49,500 | 22,200 ₹66,600 | 15,640 ₹46,920 | 12,000 ₹36,000 Lowest |
| 1.10 | Supply only Spinion lub oil filter for DG Set of capacity 250KVA | 6 | Each | 1,300 ₹7,800 | 1,150 ₹6,900 | 1,250 ₹7,500 | 1,560 ₹9,360 | 476 ₹2,856 Lowest | 850 ₹5,100 |
| 1.20 | Supply only Fuel filter element primary for DG Set of capacity 250KVA | 3 | Each | 1,100 ₹3,300 | 1,050 ₹3,150 | 950 ₹2,850 | 1,220 ₹3,660 | 374 ₹1,122 Lowest | 750 ₹2,250 |
| 1.30 | Supply only Fuel filter element secondary for DG Set of capacity 250KVA | 3 | Each | 1,100 ₹3,300 | 1,100 ₹3,300 | 950 ₹2,850 | 1,220 ₹3,660 | 374 ₹1,122 Lowest | 650 ₹1,950 |
| 1.40 | Supply only Safety air filter element for DG Set of capacity 250KVA | 3 | Each | 1,300 ₹3,900 | 1,000 ₹3,000 | 1,300 ₹3,900 | 1,550 ₹4,650 | 765 ₹2,295 Lowest | 950 ₹2,850 |
| 1.50 | Supply only Primary air filter element for DG Set of capacity 250KVA | 3 | Each | 3,800 ₹11,400 | 3,700 ₹11,100 | 3,200 ₹9,600 | 4,422 ₹13,266 | 765 ₹2,295 Lowest | 2,750 ₹8,250 |
| 2.00 | All as per items No 1 above but for DG Set of capacity 200 KVA .
Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 2.1 to 2.5
(b) Servicing will be carried out through authorized service engineer of OEM .
(c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor. | 6 | Job | 17,500 ₹1,05,000 | 16,500 ₹99,000 | 16,000 ₹96,000 | 19,650 ₹1,17,900 | 14,790 ₹88,740 | 13,000 ₹78,000 Lowest |
| 2.10 | Supply only Spinion lub oil filter for DG Set of capacity 200/250KVA | 12 | Each | 1,100 ₹13,200 | 1,100 ₹13,200 | 950 ₹11,400 | 1,252 ₹15,024 | 476 ₹5,712 Lowest | 750 ₹9,000 |
| 2.20 | Supply only Fuel filter element primary for DG Set of capacity 200KVA | 6 | Each | 1,000 ₹6,000 | 1,000 ₹6,000 | 950 ₹5,700 | 1,122 ₹6,732 | 374 ₹2,244 Lowest | 700 ₹4,200 |
| 2.30 | Supply only Fuel filter element secondary for DG Set of capacity 200KVA | 6 | Each | 1,000 ₹6,000 | 950 ₹5,700 | 950 ₹5,700 | 1,122 ₹6,732 | 374 ₹2,244 Lowest | 750 ₹4,500 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jun 2025, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
COMPREHENSIVE MAINTENANCE OF DG SET, AUTOMATIC TRANSFER SWITCHES, APFC PANELS, CHANGE OVER SWITCHES, AMF PANELS AND OTHER MISC REPAIRS AT AFS YELAHANKA
2025_MES_709034_1
8377/E8
Open Tender
Civil Works
Item Rate
270 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹90,000
Yes
18 Aug 2025
21 May 2025
25 Jun 2025
21 May 2025
18 Jun 2025
4 Jun 2025
Amount
Servicing of DG Set 250 KVA , checking Comprising of A , B and C checks at regular intervals for entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly , air cleaner assembly, lubrication oil hose flexible pipe , hose turbo etc and replacing the same with same size , make and capacity of parts . Cleaning all the serviceable filters with cleaning solution such as petrol and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil grade 15W/40 upto required level and including testing to DG Set complete all as specified and directed. Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items Sr No 1.1 to1.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 250KVA
Supply only Fuel filter element primary for DG Set of capacity 250KVA
Supply only Fuel filter element secondary for DG Set of capacity 250KVA
Supply only Safety air filter element for DG Set of capacity 250KVA
Supply only Primary air filter element for DG Set of capacity 250KVA
All as per items No 1 above but for DG Set of capacity 200 KVA . Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 2.1 to 2.5 (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 200/250KVA
Supply only Fuel filter element primary for DG Set of capacity 200KVA
Supply only Fuel filter element secondary for DG Set of capacity 200KVA
Supply only Safety air filter element for DG Set of capacity 200KVA
Supply only Primary air filter element for DG Set of capacity 200KVA
All as per items No 1 above but for DG Set of capacity 160 KVA Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 3.1 to 3.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 160kVA
Supply only Fuel filter element primary for DG Set of capacity 160KVA
Supply only Fuel filter element secondary for DG Set of capacity 160KVA
Supply only Safety air filter element for DG Set of capacity 160KVA
Supply only Primary air filter element for DG Set of capacity 160KVA
All as per items Ser No 1 above but for DG Set of capacity 125 KVA. Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 4.1 to 4.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In -Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 125 KVA
Supply only Fuel filter element primary for DG Set of capacity 125 KVA
Supply only Fuel filter element secondary for DG Set of capacity 125 KVA
Supply only Safety air filter element for DG Set of capacity 125 KVA
Supply only Primary air filter element for DG Set of capacity 125 KVA
All as per items ser No 1 above but for DG Set of capaicty 100 KVA Note :(a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 5.1 to 5.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 100 KVA
Supply only Fuel filter element primary for DG Set of capacity 100 KVA
Supply only Fuel filter element secondary for DG Set of capacity 100 KVA
Supply only Safety air filter element for DG Set of capacity 100 KVA
Supply only Primary air filter element for DG Set of capacity 100 KVA
All as per item No 1 above but for DG Set of capacity 62.5 KVA Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 6.1 to 6.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 62.5 KVA
Supply only Fuel filter element primary for DG Set of capacity 62.5 KVA
Supply only Fuel filter element secondary for DG Set of capacity 62.5 KVA
Supply only Safety air filter element for DG Set of capacity 62.5 KVA
Supply only Primary air filter element for DG Set of capacity 62.5 KVA
All as per item No. 1 above but for DG Set of capacity 50 KVA Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 7.1 to 7.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 50 KVA
Supply only Fuel filter element primary for DG Set of capacity 50 KVA
Supply only Fuel filter element secondary for DG Set of capacity 50 KVA
Supply only Safety air filter element for DG Set of capacity 50 KVA
Supply only Primary air filter element for DG Set of capacity 50 KVA
All as per Item No 1 above but for DG Set of capacity 30/25/20/15KVA Note : (a) Replacement of items mentioned in the servicing will be measured and paid separately under items No 8.1 to 8.5. (b) Servicing will be carried out through authorized service engineer of OEM . (c) Contractor has to submit all relevent documents after carrying out A , B , C Checks to Engr In Charge. (d) Contractor has to rectify the defects within 24 Hrs after getting information from the department, if he fails to do so penality of Rs.500 per Hrs after first 24 Hrs will be charged from the contractor.
Supply only Spinion lub oil filter for DG Set of capacity 30/25/20/15KVA
Supply only Fuel filter element primary for DG Set of capacity 30/25/20/15KVA
Supply only Fuel filter element secondary for DG Set of capacity 30/25/20/15KVA
Supply only Safety air filter element for DG Set of capacity 30/25/20/15KVA
Supply only Primary air filter element for DG Set of capacity 30/25/20/15KVA
M&L for changing / topping up of best quality engine oil 15W40 for various DG sets held on charge of GE (AF) Yelahanka including removing of old burnt engine oil from DG Sets complete all as specified and directed.
M&L for changing / topping up of best quality antifreezing , inhabitator corrosion (Coolant) liquid for DG sets of various capacity held on charge of GE (AF) Yelahanka including removing of old burnt engine oil from DG Sets complete all as specified and directed.
M&L for supply ,fixing in repair and installation in replacement of 63 Amp Controller Based ATS Panel complete inclduidng wiring connection and taking down existing all as specified and directed .
M&L for supply ,fixing and installation in replacement of 100 Amp Controller Based Automatic Panel complete all as specified and directed .
M&L for supply ,fixing in repair and installation in replacement of 40 Amp Controller Based ATS Panel complete all as specified and directed .
M& L for replacement of fuel pipe set for engine of DG Set of capacity 250/200/160 kVA complete all as specified and directed.
M& L for replacement of fuel pipe set for engine of DG Set of capacity 125/100/62.5 kVA complete all as specified and directed.
M& L for replacement of fuel pipe set for engine of DG Set of capacity 50/25/20/15 kVA complete all as specified and directed.
M& L for replacement of radiator hose pipe set for engine of DG Set of capacity 200/160/125kVA complete all as specified and directed.
M& L for replacement of radiator hose pipe set for engine of DG Set of capacity 100/62.5 kVA complete all as specified and directed.
M& L for replacement of radiator hose pipe set for engine of DG Set of capacity 50/25/20/15 kVA complete all as specified and directed.
S& F Battery Lead of size 35 Sq mm copper single core flexible wire FR PVC insulated with thimble providing complete all as specified and directed.
S& F in replacement Asbestos rope (heat protectable) of existing size for exhaust hose/fume circulate pipe including taking down existing complete all as specified and directed.
M&L for Servicing of self starter after taking down the same from DG Sets of capacity 250/200/160/125kVA , transporting to workshop, opening the same and replacing the defective parts/winding including testing after repair/ servicing and refixing in original position complete all as specified and directed.
M&L for Servicing of self starter after taking down the same from DG Sets of capacity 100/100/50 kVA , transporting to workshop, opening the same and replacing the defective parts/winding including testing after repair/ servicing and refixing in original position complete all as specified and directed.
M&L for Servicing of self starter after taking down the same from DG Sets of capacity 15/20/25/30 kVA , transporting to workshop, opening the same and replacing the defective parts/winding including testing after repair/ servicing and refixing in original position complete all as specified and directed.
Supply and fixing in replacement V belt set ( for fan & alternator) for 100/125/160/200/250 KVA DG set all as per existing complete all as specified and directed
Supply and fixing in replacement V belt set ( for fan & alternator) for 15/20/25/30/50 KVA DG set all as per existing complete all as specified and directed
S & F in replacement maintenance free lead acid sealed lead accumulater (SMF) 12 volts 180 AH (battery) and deposit to MES Store Yard complete all as specified and as directed.
S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 150 AH (battery) and deposit to MES Store Yard complete all as specified and as directed.
S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 100 AH (battery) and deposit to MES Store Yard complete all as specified and as directed.
M & L for replacement of locks for sound proof canopy of any make as per recommendation of OEM complete all as specified and directed.
Supply and fix in replacement electronic sensor suitable for DG Set of capacity 250/200/160 KVA complete all as specified and directed.
Supply and fix in replacement electronic sensor suitable for DG Set of capacity 125/100/100 KVA complete all as specified and directed
Supply and fix in replacement electronic sensor suitable for DG Set of capacity 25/30/50/62.5 KVA complete all as specified and directed
Taking down carefully/alternator for DG Set of capacity 250kVA/200KVA/160KVA , 415 V , 3 Phase , 4 wire system and designed on 0.8 Power factor and 1500 rpm by unscrewing and disconnecting coupling shaft from prime move side , opening winding shell cleaning removing burnt field and starter winding , cleaning removing burnt field and starter winding with super enamelled copper strip/ conductor of existing gauge , varnishing , heating / baking including reassembling all the dismantled component to its original position with testing alternator to its optimum efficiency ie 415 Volts output at 1500 rpm at 0.8 PF to the satisfaction complete all as specified and directed
All as per Item No.34.00 above but for DG Set of capacity 125/100/100KVA
All as per Item No.34.00 above but for DG Set of capacity 62.5/50/30/25/20/15KVA
Supply and fix in replacement complete FIP assembly (injector assembly ) of DG Set of capacity 125/100 KVA by unscrewing nuts bolts from its mounting dismantling cleaning , replacing , gasket set feed pump , plunger for proper fuel combustion and functioning at optimum efficiency including re assembling all dismantling components to its original position complete all as specified and directed.
Supply only main shaft as per sample
Supply only techno shaft as per sample
Supply only weight carrier as per sample
Supply only governor barrel plunger as per sample
Supply only MVS plunger as per sample
Supply only gasket sets as per sample
Supply only Damper assembly as per sample
Supply and fix in replacement complete FIP assembly (injector assembly ) of DG Set of capacity 250/200 KVA by unscrewing nuts bolts from its mounting dismantling cleaning , replacing , gasket set feed pump , plunger for proper fuel combustion and functioning at optimum efficiency including re assembling all dismantling components to its original position complete all as specified and directed.
Supply only main shaft as per sample
Supply only techno shaft as per sample
Supply only weight carrier as per sample
Supply only governor barrel plunger as per sample
Supply only MVS plunger as per sample
Supply only gasket sets as per sample
Supply only Damper assembly as per sample
Repair/maint/testing and servicing of AMF panels of DG Set of capacity 100 KVA installed at tech area of AFS Yel Note : The following spares parts shall be measured and paid under item No. 39.1 to 39.4 separately , any other spares parts required for making functional shall be deemed to be included in the quoted rate .
Controller
Relay card 12V
Battery terminal
Power contactor 160 Amp
Repair/maint/testing and servicing of AMF panels of DG Set of capacity 63 KVA installed at tech area of AFS Yel Note : The following spares parts shall be measured and paid under item No. 40.1 to 40.4 separately , any other spares parts required for making functional shall be deemed to be included in the quoted rate .
Controller
Relay card 12V
Battery terminal
Power contactor 4 P, 100 Amp
Repair/maint/testing and servicing of AMF panels of DG Set of capacity 50 KVA installed at tech area of AFS Yel Note : The following spares parts shall be measured and paid under item No. 41.1 to 41.4 separately , any other spares parts required for making functional shall be deemed to be included in the quoted rate .
Controller
Relay card 12V
Battery terminal
Power contactor 4P ,63 Amp
Repair/maint/testing and servicing of AMF panels of DG Set of capacity 25 KVA installed at tech area of AFS Yel Note : The following spares parts shall be measured and paid under item No. 42.1 to 42.4 separately , any other spares parts required for making functional shall be deemed to be included in the quoted rate .
Controlller
Relay card 12V
Battery terminal
Power contactor 4 P, 40 Amp
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to GI Strip of size 32x6mm upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15 mm dia and 20 mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed.
Supply and laying in trenches, LT underground cable of size 35 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed.
All as per item No 44.00 but 70 Sqmm 3.5 core
All as per item No 44.00 but 95 Sqmm 3.5 core
All as per item No 44.00 but 120 Sqmm 3.5 core
Supply and fix in repair CTs of size 200/5 Amps all as specified and as directed.
Supply and fix in repair CTs of size 400/5 Amps all as specified and as directed.
Supply and fix in repair CTs of size 100/5 Amps all as specified and as directed.
Supply and fix in repair LED indicator lamps (R Y B ) suitable for existing panel all as pecified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.
Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Returning filling in excavated soil with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm all as specified and as directed.
Taking down the unserviceable changeover switch after disconnecting from LT panel board , supply and fix new on load type changeover SS enclosure 415V 200A 4Pole , 50Hz including necessary fabrication , addition and alterations all as specified and directed.
Taking down the unserviceable changeover switch after disconnecting from LT panel board , supply and fix new on load type changeover SS enclosure 415V 400A 4Pole , 50Hz including necessary fabrication , addition and alterations all as specified and directed.
S&F in repair On load change over switch 125 Amp 4 Pole 415 volts ,50 Hz suitable for existing panel board all as specified and directed.
S&F in repair On load change over switch 63 Amp 4 Pole 415 volts ,50 Hz suitable for existing panel board all as specified and directed.
S&F in repair On load change over switch 160 Amp 4 Pole 415 volts ,50 Hz suitable for existing panel board all as specified and directed.
Servicing and cleaning of exhaust vent hoods with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required (Twice during the contract period) all as directed.
Servicing and cleaning of exhaust SS hoods with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc. (Twice during the contract period) all as directed.
Servicing and cleaning Grease filters with necessary chemical consumables all as directed
Servicing and repairs including windings of Exhaust Blower of 5 HP all as directed
Remove unserviceable 3HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing,refixing as directed
Remove unserviceable 5HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing,refixing as directed
Supply and fixing inrepairs 0.8mm thick, GI Ducting as per required size as per site condition as directed.
Comprehensive maintenance and servicing of gate barriers of span 5.5 metre, electrically operated, lifting type, of including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc, complete for smooth functioning all as specified and as directed. Note: The period of interval for cleaning shall be per months.
Comprehensive maintenance and servicing of Hangar gate electrically operated including repairs and servicing of electrical motor, fly wheel, pinions, clutch plates, limit switch, control cables, switch gears and replacement of oil etc., complete for smooth functioning all as specified and as directed. Note: Electronic Controller shall be measured and paid separately
Supply and Fix Electronic Controller for suitable Gate Barrier any make all as directed
Supply, Install testing and commissioning in replacement of Automatic transfer switch of capacity three phase 415 Volt, 50Hz, 4 pole and 160 Amp having suitable to 02 incoming and one out going with inbuilt time delay. The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and vise versa automatically, the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work and taking down existing complete all as specified.
Supply, Install testing and commissioning in replacement of Automatic transfer switch of capacity three phase 415 Volt, 50Hz, 4 pole and 100 Amp having suitable to 02 incoming and one out going with inbuilt time delay. The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and vise versa automatically, the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work and taking down existing complete all as specified.
Supply and fixing in replacement of heavy duty Capacitor cylindrical type of 25 KVAR capacity fixed in existing APFC Panel complete all as specified and directed.
All as per Item No. 74.00 above but for 15 KVAR Capacitor
All as per Item No. 74.00 above but for 10 KVAR Capacitor
All as per Item No. 74.00 above but for 5 KVAR Capacitor
All as per Item No. 74.00 above but for 2 KVAR Capacitor
All as per Item No. 74.00 above but for 1 KVAR Capacitor
Supply and fixing in replacement of Capacitor heavy duty contactor of 25 KVAR MOC25/ TC1D 25 capacity fixed in existing APFC Panel complete all as specified and directed.
All as per Item No. 75.00 above but for 15 KVAR Capacitor MOC15/TC1D 15
All as per Item No. 75.00 above but for 10 KVAR Capacitor MOC10/TC1D 10
All as per Item No. 75.00 above but for 5 KVAR Capacitor MOC10/TC1D 05
All as per Item No. 75.00 above but for 2 KVAR Capacitor MOC2/3/TC1D 02
All as per Item No. 75.00 above but for 1 KVAR Capacitor MOC2/3/TC1D 01
Supply and fix in repair MCCB 200 Amps, 4 pole 36 KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
Supply and fix in repair MCCB 125 Amps 4 pole 25KA, adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
Supply and fix in repair MCCB 100 Amps 4 pole 25KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
Supply and fix in repair MCCB 63 Amps 4 pole 18KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
Supply and fix in replacement old unserviceable SMF type 12 volt 42 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed.
ADR ENTERPRISES (BID ID -3320281)
devan enterprises (BID ID -3319457)
Sanidhya Enterprises (BID ID -3319892)
chowdeshwariconstructionco (BID ID -3319628)
Lucky Enterprises (BID ID -3327852)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .