| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.4 L+₹42,774.32 (1.07%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.0 L+₹2.0 L (5.08%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹42.4 L+₹2.4 L (5.95%)Rejected-Finance DADAWA KURIYAR KHAS BASTI BASTI UTTAR PRADESH 272178 | BASTI | UTTAR PRADESH | 272178 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹43.3 L+₹3.3 L (8.38%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹41.3 L
EMD Value
₹82,600
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
SPECIAL REPAIR TO SINGLE JCOS LIVING BLDG NO P-08 OF 5 PARA (SF) AT BP LINES UNDER GE (EAST) AGRA
2024_MES_676905_1
9716/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹82,600
Yes
22 Nov 2024
27 Sept 2024
18 Oct 2024
27 Sept 2024
11 Oct 2024
4 Oct 2024
Amount
Taking down of old roof treatment of any description including mud phushka, lime concrete, tiles, cement plaster from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc. 250 mtr and not exc 500 mtr from the roof of height 3 to 9 mtr etc complete all as specified and directed.
M& L for water proofing treatment with APP based polymeric membrane 3 mm thick of weight not less than 3.5 Kg/sqm reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) shall be applied over and including one coat of water based bituminous emulsion primer on newly plastered surface @ 0.40 Kg / Sqm duly thermo fused by flame torch all as specified in method of application manual of the manufacturer complete all as specified and directed.
M&L for 10mm thick plastering in CM 1:4 with WPC over roof surfaces of walls & finishing the surface even & smooth and Brushing neat cement slurry with 3.0Kg of cement per Sqm complete etc complete all as specified and directed.
Providing, PCC 1:2:4 type B-0 using 12.5 mm stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throttling, as directed complete all as specified and directed.
M&L cutting out cracks to V Section in existing roofs or terracing cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 complete all as specified and directed
Cutting chases,pinning in brick/stone walling / RCC and making good by CM 1:3 or PCC 1:2:4 12.5 mm graded aggregate for inserting bituminous tar felt cutting /tubing not exc 10 cm girth complete all as specified and directed.
Supply only liquid Water Proofing Compound complete all as specified and directed.
Material and Labour preparation of new or previously untreated roof surfaces of any description over 10 cm width or girth and apply two coat of aluminium paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
M & L Ceramic tiles light shade 10 mm thick(square/ rectagular) polished, area of each tile not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No 10.00 above but in skirting over 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x300x7mm thick fixed on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in cement mortar 1:4 on brick work or concrete surfaces complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring over 20mm thick cement screed bed in CM 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of stone slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed.
M&L for pre-polished Kota stone slab 20-25 mm thick in riser of steps, skirting, dado including 10mm thick plaster or bedding layer in CM (1:4) for receiving the tiles and jointed complete all as specified and directed.
M&L Varoda green marble makrana Adanga stone 18 to 20 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified and directed.
Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface finished other than fair complete all as specified and directed.
S & F for 500 Litres capacity rotational moulded poly ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I with & including PVC Float valve 20mm bore, Tank cover, wash out and overflow pipe necessary tank nipples, after Dismantling existing tanks from roof slab/ staging of single/double storey bldg, lowering, complete all as specified and directed.
Taking up or down 15 mm bore steel tubing/CPVC pipe including fittings and connections, including cleaning for Refixing or removal to store complete all as specified and directed.
S& F 20 mm outer dia of CPVC pipes SDR 11 & plain CPVC pipes SDR 11 fitting on wall,floor and ceiling etc complete all as specified and directed.
S&F 20 mm outer dia of CPVC brass elbow fixing to CPVC pipes on any location and position etc complete all as specified and directed.
S& F 20 mm outer dia of CPVC brass Tee fixing to CPVC pipes on any location and position etc complete all as specified and directed.
Taking up or down 20 mm bore steel tubing/ PPR pipe including fitting and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F 20 mm bore Galvanized Steel tubes, medium grade with all fitting GI/CPVC and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g ms. / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
Supply and fixed in repair PVC bath Cabinet of size 450x600mm with shelf and front side mirror of make Prayag etc complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin counter type white flat back size 550x400mm including brackets , CP waste coupling and 32 mm pvc flexible waste pipe 800 mm long etc complete all as specified and directed.
S&F Low density polyethylene (LDPE) pipes 32 mm of pressure rating 6 kgf/Sq cm & 800 mm long including elbow complete all as specified and directed.
Supply and Fix in repair, brass CP two in one wall mixer in lieu of old unsv CP brass bid tap for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed.
Supply and fix in repair 15mm bore Basin mixture in lieu of old unsv CP brass bid tap for mixing hot and cold water , chromium plated with CP flange screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore stop cock, fancy type, chromium plated with long shank and cup (Concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Supply and fixed angular valve , 15mm dia,Stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for and fixed for 15 mm bore GI pipe or for unions and fixed for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S&F in repair bib taps cast copper alloy, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
S&F in repairs 10litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & taking out of old unserviceable connections etc, connecting up new and making good disturb portion complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
Supply & fixing in repair tubular towel rail,, 20mm dia D type, 60 cm long Brass chromium plated complete all as specified and directed.
S & F in repair CI floor trap, plain with grating including jointing with solvent cement (Diameter of outlet 75mm), jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1) mixed with pedilite water proofing liquid @ 200ml in 50 kg cement, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed.
Supply & fixing in repairs C.P. grating 100/125 mm dia with or without centre hole etc all as reqd at site complete all as specified and directed.
S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with CI 'P' or 'S' trap including connection to trap and cistern and flush pipe (excl flusingh cistern ) and making good to disturbed surface of floor all fixed complete all as specified and directed.
S & F of plastic wc seat cover and mild steel chromium plated or aluminised hinging device as etc complete all as specified and directed.
S & F in repair health faucet (ABS body) mild steel Chcomium Plated suitable for 15mm dia pipe 1.25m long flexible tube and ABS wall hook including making connection and fixed in position for pedestal pattern WC incl complete all as specified and directed.
S&F in repairs CP Soap dish 100mm dia fixed with cp screws etc complete all as specified and directed.
Supplied and fixed in repair of 10 mm thick glass corner shelf set of 3 Nos (size 200 mm, 250mm & 300 mm) in lieu of granite shelf complete all as specified and as directed.
S & F toilet paper Holder with Flap Recessed Type (Stainless Steel) complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 sqm each complete all as specified and directed.
S&F of factory made soild PVC door frame of size 50mmx47mm made out of 5mm thick single side prelam PVC sheet reinforced with mild steel square tube , supplying & fixing in opening as per specification and drawing complete all as specified and directed.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S & F tubular steel farmed work as in doors (as in ckowkats) for single door frames of 2.5mm thick size100 x 50mm including necessary fixing lugs, lock strike plate incl locking arrengemet hold fast, complete all as specified and directed. (tubular steel100x65mm@ 5.33kg/Rm).
S & F tubular steel farmed work as in doors (as in ckowkats) for double door frames of 2.5mm thick size130 x 65 including necessary fixing lugs, lock strike plate incl locking arrengemet, hold fast, etc complete all as specified and directed. (tubular steel130x65mm@ 6.99kg/Rm).
S & F 35 mm thick flush shutters, board solid core construction, with block board core and plywood face panels, if both face is covered with decorative face veneer with lapping/ frame to match complete all as specified and directed.
S & F Glazed or skeleton factory made door shutter, 35mm thick of second class hard wood (hollock), open rebated and prepared to receive glass, gauge (without sash bars) with plain, chamfered or rounded, mitred beads for glass etc , size of members of shutters shall be as specified in SSR Part I, section -8 clause 8.24 (a) complete all as specified & directed.
S&F 100 mm size stainless steel butt hinges medium weight cold rolled. fixed with screw/ welding complete all as specified and directed.
Supply and fix for 150mm long aluminium handles, cast type, anodised complete all as specified and as directed.
Supply and fix in for 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
S&F Floor door stopper 150 mm long of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor complete all specified and directed.
S & F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate fixed with screw/welding complete all as specified and directed.
S & F 300 mm mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding of hold fast etc including desterb surfase of existing pogition complete all as specified and directed.
S & F windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm minimum thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pit ch complete all as specified and directed.
S & F ventilator made of pre-painted steel (Base steel as per IS 513 of 0.58 mm minimum thick “D” Quality galvanized as per IS 277 with Zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 52x 25mm and rebate for Glazed shutter with a 20mm provision for Guard bars/Grills. The sections are to be cut to length metre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle, stay, 2 nos. of Stainless Steel heavy duty Pivot hinges shall be provided per shutter the windows fitted with 4mm thick plain float glass with rubber gaskets including fixing the frames in concrete/masonry wall by means of self expanding screws, Including fixed panel beading section should be of 12x12mm. Outer frame and mullions to have 10mm Square guard bars with 6” (152.4mm) pitch etc., complete all as specified & directed.
S & F 18 mm thick with min density 600 Kg / cum LEAD FREE PVC Cheluka ply of single side rigid laminate of approved color and other side plain white colour fixed with SS screws and solvent cement/ adhesive to make cup board shutters complete as per manufacturer’s instructions including dismantling of existing timber boarding complete all as specified and directed.
S&F 75 mm long brass handles, cast type polished bright complete all as specified and directed.
S&F 125mm long aluminium anodised Hasp and Staple, safety type including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repairs mild steel stainless steel drapery rods, 25mm internal diameter including decorating type domes including fixing arrangement with drilling holes in walls supported with brackets etc complete all as specified and directed.
S & F Welded steel wire fabric supplied and fixed complete to wood or steel members weight n exceeding 4 Kg/ Sqm complete all as specified and directed.
Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick work / concrete surfaces of walls & finishing the surfaces even and smooth without using extra cement etc complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4 on wall with WPC on concrete surfaces of finishing the surface even & smooth complete all incl water proofing compound complete all as specified and directed.
M&L for two coats of OBD over a coat of average 2 mm thick birla putty on newly plastered surfaces complete all as specified and directed.
Material & labour 10mm thick rendering in CM 1:3 concrete surfaces of ceiling etc, finished surfaced even & smooth without using extra cement complete all as specified & directed.
Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash to match the existing as required, complete all as specified & directed.
Material and Labour for preparation of old plastered or unplastered surfaces of ceiling including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply three coat of white wash on ceiling complete all as specified and directed.
M&L for applying two coats of oil bound distemper with roller on old decorated wall surfaces over 2 mm thick white putty including complete removal of existing treatment with mechanical complete all as specified and directed.
M&L for preparation of plastered or unplastered surfaces of wall, concrete surfaces, and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489: 2004n Alkali & fungal resistance, dirt resistance exterior paint of required shade ( company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior applied @ 0.90 litre/10 Sqm over new surfaces (weather coat ) in any shade or colour as approved ( including necessary arrangements to paint the same in multiystorey bldgs up to G+2 ) complete all as specified and directed.
Material and labour for preparation of new wooden surfaces over 10cm width or girth and applying two coats synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of new steel or iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fix stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples complete all as specified and as directed.
Removing or dismantling of damage / cracked/ concrete /loose concrete / plaster of celing/ wall/ chajja/ facia to expose the sound and hard concrete using a suitable mechanical device or by hammer and chisels etc complete all as specified & directed.
M & L for applying 15 mm thick ( average ) smart care repair mortar ready to use single component polymer modified repair mortar for repair of RCC members likes beams, columns, chajja , facia , mortar having good compressive strength and shrinkage resistance , yield of repair mortar is 14,10 litres at water / powder ratio of 0.19 per bag etc complete all as specified & directed.
M & L for applying bonding agent for bonding old to new concrete surface likes chajja/ beams/ celings/ columns/ facia etc by high performance modified Styrene- Butadiene Rubber ( SBR ) base binder . Applying of binder is as 10 sqm/ per lit etc complete all as specified & directed.
Demolition of cement concrete of any description and any position etc complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C1 using 20mm graded stone agg as in plinth protection/Path/paving surface even and smooth and and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) incl dismantling of existing surface complete all as specified and directed.
M & L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying ement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed.
Taking down PVC pipe (Soil waste pipe and rain water pipe) etc of any type/ size pipes (any size or pattern), including all fittings etc complete all as specified and directed.
S&F 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls in lieu of old unsv PVC pipe including making good disturbe portion to match the existing complete all as specified and directed.
S&F 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed laid in tranches, floor in lieu of old unsv PVC pipe including making good disturbe portion to match the existing complete all as specified and directed.
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturbed portion to match the existing complete all as specified and directed.
S&F 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbed portion to match the existing complete all as specified and directed.
S&F 100 mm bore cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbed portion to match the existing complete all as specified and directed.
S&F 75 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls including making good disturb portion to match the existing complete all as specified and directed.
S&F 75 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed laid in tranches, floor including making good disturbe portion to match the existing complete all as specified and directed.
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and jointed with cement joint including making good disturb portion to match the existing complete all as specified and directed.
S&F 75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturb portion to match the existing complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F in clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 110 mm bore pipe complete all as specified & directed.
S&F in clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 75 mm bore pipe complete all as specified & directed.
M & L for cement concrete 1:5:10 type E2 (40 mm graded stone aggregate) as in foundation filling and mass concrete or sunken etc complete all as specified and as directed.
M& L for cement concrete padding 1:2:4 type B0 (12.50 mm graded stone aggregate) 40 mm thick in sunken of bath /toilet /Kitchen etc with and including WPC as per manufacture's instruction complete all as specified and directed.
Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and applying a coat of cement slurry with 3.00 kg of cement per sqm and rendering 15mm thick in CM 1:3 using WPC finished rough (Sunken floor/Wall) and then applying two course treatment as follow:- (i) Applying bitumen primer @ 0.40 Kg/Sqm. (ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3.50 kg/Sqm with 100 GSM/Sqm non woven polyster mat as centre core reinforcement , laid with 75mm side over lap and 100mm end over lap sealed and finsihed neat. (iii) 40mm bore GI pipe for Spout pipe length 0.75m.
S&F for Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete all as specified and directed., drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete, quality conforming grade Fe- 290 or E- 165 complete all as specified and directed.
S&F in repairs 100 mm bore cast iron cowel and cement joint complete all as specified and directed.
M&L 75 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in sub base of floor to receive tiles complete all as specified and directed.
M&L for machine pressed coloured rubber moulded chequered tiles 30 cm x 30 cm x 20 to 22 mm thick set, jointed & pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and ncluding taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and modular sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch.
(b) One 5 pin socket outlet 5 Amps on independent board
(c) One 5 pin socket outlet 5 Amps on same board
(d) One light point controlled by two 2 - way switches , with cables 1.5 sqmm size.
All as per item No 112.00 here in before but with FRLSH cable size 4 Sq mm for one 5 pin 15/16 Amps socket out let on independent board/AC Box and multistrand insulated copper earth continuity conductor of size 4 sqmm complete all as specified and directed.
Supply and fixing modular switch piano single pole, one way 6 Amps 1 module, complete all as specified and directed.
Supply and fixing in repair modular switch piano single pole, two way 6 Amps 1 module, complete all as specified and directed.
Supply and fixing modular switch piano flush type 16 Amps single pole one way, one module, complete all as specified and directed.
Supply and fixing modular socket outlet 2/3 pin 6 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular socket multipurpose 3 pin 6/16 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular step type two module electronic fan regulator heavy duty 120watts 240 volts complete all as specified and directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals complete all as specified and directed.
Supply and fixing modular cover plate with frame (inner and outer) 1 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 8 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing blank spacer plate for single module complete all as specified and directed.
Supplying and fixing 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified and directed.
Supplying and fixing 10 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 10W, luminaire lumens > 1000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified and directed.
Supply & fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED Lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply & fixing LED security light compact & trendy of 35 watt with aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3000 lumens/W and in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95, as per IEC 61000-3-2, colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, multi stage constant current operated driver with range 150-270 VAC and safety exra low voltage safe load < 60 VDC as per IEC standards with LM 70 & 80 certification complete all as specified, fixed to pole or wall of buiding with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces complete all as specified and directed.
M&L for sub main wiring using two 2x 6 sqmm single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC (green colour) insulated, unsheathed, stranded FRLSH copper conductor of size 6 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
Disconnecting and taking down old unserviceable distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces to the existing surfaces complete all as specified and directed.
Supply & fix in replacement sheet metal enclosure MCB distribution board. TPN 415 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all as specified and directed.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
S&F in repair sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug top with one SP MCB 20 Amp 240 volt complete all as specified and directed.
Supply and fixing MCB SP 1 to 32 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SPN 32 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB TPN 100 Amps, 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Dismantling, taking down exisitng ceiling fan/Exhaust fan and deposited to E/M store for re-fixing and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed.
Supply, fixing, connecting & testing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), and including connecting wire with new 3 core 0.50 Sqmm PVC insulated and unsheathed copper conductor cable from ceiling rose and also writing MES No with black paint complete all as specified and directed.
Supply and fix in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermo state, NRV, connection piece etc also writing MES No with black paint complete all as specified and directed.
3Krishna Enterprises (BID ID -3134735)
Shiva Enterprises (BID ID -3133655)
Abhi Construction (BID ID -3136048)
Gupta Automobiles (BID ID -3136490)
M/s SCHOLASTIC ENTERPRISES (BID ID -3136175)
m/s shanti consruction co (BID ID -3136477)
M/s Kok Singh Sisodia (BID ID -3136290)
M/S RADHEY GOVIND ENTERPRISES (BID ID -3136100)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .