EE(E)/ELD-5/DDA
CENTRAL NURSERY SECTOR 5 DWARKA NEW DELHI
Running maintenance and operation of 380 KVA 62.5 KVA and 45 KVA DG sets, booster pump sets, storm water pump sets, firefighting pump sets, Mechanical ventilation system, Lift pressurization system and rescue of Omega make lifts street lightin
2026_DDA_899634_1
31/EE/ELD-5/DDA/2025-26
Open Tender
Electrical Works
365 days
EE(E)/ELD-5/DDA
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹1.0 L
SE(E)DWK
25 Mar 2026
20 Feb 2026
7 Mar 2026
20 Feb 2026
6 Mar 2026
20 Feb 2026
24 Feb 2026
Running, maintenance & operation of clear water booster pump sets, D.G. sets, Mechanical ventilation , Lift pressurization ,basement Storm water ,common area lighting and fire fighting system, compound/street lighting and pumps etc. as per inventory and terms & conditions attached.
Providing lift operators for rescue & coordination of Omega make lifts as per inventory and terms & conditions attached.
Providing and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. a) 250 A,36KA,FPMCCB
b)400 A,50KA,FPMCCB
Supply of 12V, 7Ah Lead acid battery for ARD system for lifts. (Make-Exide/Amaron)
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) a)18-22 Watt
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 1X1.5 sq. mm
b)2X4 sq. mm
Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in a respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 72 Watt
Supplying of following size of XLPE insulated aluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd. a) 2C x 16 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 63 mm dia (OD- 63 mm & ID-5 mm nominal)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Servicing of 380KVA DG set (Kirloskar make engine)) i/c supply and replacement of following items. Fuel Filter cartridge -2set. LUBE OIL FILTER -2 Nos. SPINON OIL FILTER ASSLY -1 Nos. PRIMARY ELEMENT- 3 Nos. SECONDARY ELEMENT- 1 Nos. FUEL FILTER ELEMENT- 1 Nos. DISTILLED WATER 1 LTR- 5 Can SYNETHIC JELLY- 2 Nos. Kirloskar Care Genuine Coolant Premix 5 Liter Can- 1 Nos. Kirloskar Care Premium Genuine Oil 50 ltr. Can- 1 Nos. Kirloskar Care Premium Genuine Oil 26 ltr. Can- 1 Nos. Air cleaner safety element- 1 Nos.
Servicing of 62.5 KVA Diesel engine i/c supply and replacement of following items. SPIN ON LUBE OIL FILTER -1 ltr. PRIMARY ELEMENT- 3 Nos. SECONDARY ELEMENT- 1 Nos. FUEL FILTER ELEMENT- 1 Nos. DISTILLED WATER 1 LTR- 2 Can SYNETHIC JELLY- 2 Nos. Kirloskar Care Genuine Coolant Premix 5 Liter Can- 1 Nos. KKirloskar Care Premium Genuine Oil 13 Liters Can -1 Nos.
Servicing of 45 KVA Diesel engine i/c supply and replacement of following items. SPIN ON LUBE OIL -1 ltr. PRIMARY ELEMENT- 1 Nos. FUEL FILTER ELEMENT- 1 Nos. DISTILLED WATER 1 LTR- 2 Can SYNETHIC JELLY- 2 Nos. Kirloskar Care Genuine Coolant Premix 5 Liter Can- 1 Nos. Kirloskar Care Premium- 1 Nos. Genuine Oil 13 Liters Can- 1 Nos.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 8.78 MB
BOQ_945628.xls
BOQ • 0.35 MB
NIT31.pdf
Tender Documents • 2.05 MB
Download all tender documents and submit your bid