Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.9 L+₹50,691.77 (1.92%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹32.5 L+₹6.0 L (22.9%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹28,400
Closing Date
3 Feb 2023, 6:00 pmClosed
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/MAINT TO E/M INSTALLATION AND ELECTRICAL ENERGY AUDIT OF ASSETS HELD ON CHARGE OF GE (AF) SARSAWA AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2023_MES_573224_1
8122/SAR-40/2022-23
Open Tender
Civil Works
Item Rate
333 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹28,400
Yes
14 Mar 2023
5 Jan 2023
10 Feb 2023
5 Jan 2023
3 Feb 2023
20 Jan 2023
5 Jan 2023 - 20 Jan 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixturesand making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan/exhaust point controlled by one way switch
All as per item No. 02 here-in-before but One 5 Amp socket outlet on independent board. complete, all as specified & directed.
All as per item No. 02 here-in-before but One 5 Amp socket outlet on same board complete, all as specified & directed.
All as per above item No-2 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed.
S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping and accessories shall be measured separately. (ii) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length.
S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
M&L for defect rectificati on HT 11 KV/LT 1.1KV cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3/3.5core. The fault locating equipments will be brought to site within 24 hours of instruction from Engineer-in-Charge.Note:- cable joint and its fixing shall be measured and paid saperately under respective item of schedule.
S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 6 ways 240 V complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F in replacement MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall complete all as specified and directed..
S&F in replacement of 10 watt five star rating LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement of 15 watt five star rating LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable pole &stay etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge. Note : 18 cm thick only will be considered for pryment purpose.
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 50 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 70 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old unsv cable complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old unsv cable complete all as specified and as directed. Note for srl No 30 to 37 :- Excavation and earth work, GI pipe, brick and sand cushioning or cable protection cover shall be measured and paid separately.
M&L for Straight through / end joints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 06 sqmm to 16 sqmm and testing after jointing complete all as specified and as directed.
All as per item No. 35 here-in-before but for cable 3.5/4 core 25 sqmm to 50 sqmm
All as per item No. 35 here-in-before but for cable 3.5/4 core 70 sqmm to 120 Sqmm
All as per item No. 35 here-in-before but for cable 3.5/4 core 150 sqmm to 185 Sqmm
Labour for angering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
Supply and laying in replacement of 63/50 mm outer dia/ inner dia, double walled, corrugated DWC duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 90/76 mm outer dia/ inner dia, double walled, corrugated DWC duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 50mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying in replacement of 32mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
M&L for PCC 1 : 4 : 8 type D2 Using 40 mm graded stone aggregate for foundation of poles/approch path/panel foundation complete all as specified and directed .
M&L for chequred cement concrete tile 20 cm x 20 cm x 25 mm thick, set. Pointed & jointed in neat cement slurry in floor polished with grey cement & pigment layered over 20 mm thick cement screed base (1:6) and all as directed by Engineer-in-charge.
M&L for surface exacavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.200mm wall thickness HT tape with adhesive of good quality all as specified and directed.
Material and labour in replacement of earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) & including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fixing in replacement 32 x 6 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engineer-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified & as directed.
Supplying and laying synthetic Rubber insulated mats 3mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified & as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing Kit for 11 KV (E) grade cable for straight through heat shrinkable type joint with jointing material and accessories for 95 sqmm 3 core XLPE, HT cable including cutting after taking down/out joint kit as existing at site complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supply and fixing 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy , cast alluminium alloy housing IP 66 protection, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as directed and specified.
Supply and fixing 60 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy , cast alluminium alloy housing IP 66 protection, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as directed and specified.
Supply and fixing 30 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Supply and fixing 70 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Supply and fixing 120 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Supply and fixing 150 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed.
Supply & fix Decorative LED Post Top Lantern light fitting with max. system wattage 40 watt and system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, surge protection 5 Kv,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution including taking out old any type light all as specified and directed by Engr-in-charge. Notes:- 1. Name of the MAKE of the luminaire should be embossed on the luminaire fittings.
S&F in replacement multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 1.5 sqmm 3 core, length not less than 1.5m each drawing through tubular pole and GI brackets etc upto choke/lamp and making connections and testing for functioning of light fittings complete all as specified and as directed.
S&F in replacement multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.5 sqmm 3 core, length not less than 1.5m each drawing through tubular pole and GI brackets etc upto choke/lamp and making connections and testing for functioning of light fittings complete all as specified and as directed.
S&F in replacement Non metallic Junction box made out of thermoplastic size not less than 18 cm x10cmx8cm hinged with lockable arrangement including aluminium bus bar SPN capacity 40Amp with one No MCB 2 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
S&F in replacement of onload changeover 4 pole, 200 Amps, 415 volts in sheet metal enclosure including taking down old unsv changeover complete all as specified and directed.
S&F in replacement of onload changeover 4 pole, 100 Amps, 415 volts in sheet metal enclosure including taking down old unsv changeover complete all as specified and directed.
M&L for pcc 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified.
M&L for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. of grade Fe 290 (Gde E 165) complete all as specified and directed by Engr-in-charge.
M&L for CRCA mild steel sheet of size 2 mm thick suitable for 3 phase 415 Volts 50 Hz complete painted with powder coated in siemens grey shade 7035 all as approved by Engr-in-charge for LT feeder enclosure of desired shape and size directed by Enr-in-charge of existing LT feeder panel double/single door type as directed with all fastening and fabrication element required at site complete.
Supply and fixing Exhaust Fan , steel body AC single phase ,230 V of size 450mm sweep heavy duty with, blades , frame and louvers with all fixing element including taking down old unsv exhaust fan and deposited to MES Yard complete all as specified and directed by Engr-in-charge
Taking down old unserviceable single pointed termination rod any type over the roof from PCC block/GI pipe complete all as specified and directed.
Supply and fix single pointed termination aluminium rod 12 mm dia, 300 long on roof top including fixing/fitting of termination rod and over the roof in PCC block/GI pipe and making connection with roof/down conductor with Al strip by proper bolting/brazing etc complete all as specified and directed. Note : PCC and GI pipe shall be measured and paid separately under respective item of sch.
Supply and fix aluminium strip in replacement of size 25x3.15 mm for Earth continuity conductor or main earthing lead fixed to wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation including taking down old unsv strip complete all as specified and directed. Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
M&L for test point terminal block in replacement made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex.head screw complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement insulator/ separator of DMC/SMC material fixing screws on wall/ roof for laying of down/roof conductor complete all as specified and directed by Engineer-in-Charge.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface broken stone or boulders
Supply and fixing in replacement of Signage board Retro reflective of MS back ground with Engineering grade blue colour matter & border should be written with prismatic HIP colour tape size of the board 4'x3' single side written including post of MS square 40mmx40mmx10'complete including necessary fixing to the ground by necessary excavation and earth work and grouting with PCC 1:2:4 (with 20mm graded stone aggregate up to depth of 2 feet complete all as specified and directed by Engineer-in-charge .
Supply and fixing of Electric shock treatment chart in wodden frame box complete all as specified and directed.
S&F in replacement of mild steel chequered plates 5 mm thick or over in thickness avilable size duly painted with two coat of black bituminous paint over one coat of red oxide primer and cut to shape for cable duct complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of HDPE pipe laying of size 150 mm bore in trench with siuitable fitting such as bend,elbow,tee,, reducer etc including necessary exacavation and joints complete all as specified and directed by Engr-in-charge.
S&F in replacement of Rewirable switch fuse unit 4 pole, 63Amps, 415 volts in sheet metal enclosure including taking down old unsv fuse unit complete all as specified and directed.
S&F in replacement of Rewirable switch fuse unit 4 pole, 100 Amps, 415 volts in sheet metal enclosure including taking down old unsv fuse unit complete all as specified and directed.
S&F in replacement of Rewirable switch fuse unit 4 pole, 32 Amps, 415 volts in sheet metal enclosure including taking down old unsv fuse unit complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in any type of soil.
M & L for Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire all as specified.
Supply in replacement of MS galvanished chain link fencing with 3 mm dia and size 50 mm x 50 mm including line wires including strain bolts, binding wire , taking down old damaged fencing complete etc all as directed.
S&F in replacement of mild steel screw bolts (machine made) with hexagonal head at one end and screwed the other or screwed both ends each screwed and to be fitted with washers and with hexagonal nut of exc 5 cm length with dia of shanis 11 to 15 mm etc all as specified and directed.
S&F in replacement of mild steel work such as in fencing post, tie bars etc including embedding into concrete and making holes for screwing of nut, bolts, cutting top to shape as directed, drilling holes, notching for wire etc confirming Fe 410-0 or Fe 310-0 all as specified and directed.
M&L in replacement for framed work as in doors, gates of angle fe -410 gde E 250 qureed section with gussed plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges all as directed by Engr-in-Charge.
M&L for 2 coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc 10 cm width or girth etc.
M&L in replacement for steel work in tubular truess, purline rafter columns etc including welding ,butt welded tubes conferming to IS-1161-1979 grade St-240, complete all as directed by Engineer-in-charge.
S&F in replacement of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas as specified fixed etc complete all as specified & directed by Engr-in-Charge.
M&L in replacement for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified & directed by Engr-in-Charge.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Supplying and topping up of transformer oil of dielectric strength not less than 45 BDV to comply IS-335 of 1993 here-in- before, complete all as specified and as directed.(Note:- Oil shall be in comany sealed barrel having BDV not less than 45 KV)
Supply and fixing of Line diagram of electric supply feeder in wodden frame of size not less than ( 2.5 feet x 3 feet ) complete all as specified and directed.Note :- matter shall be provided by Engr-in-charge.
Supply & fixing in replacement of Fire safety Axe complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of Fire Beater with wooden handle complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in replacement of DC battery bank with charger having input connection of 230 V AC and output 30 V DC comprising of the following:- (a) Battery bank of 15 Nos 2V 100 AH with stand capacity with VRLA battery bank conforming to IS 1651-1979, performance as per IS-8702 nominal cell voltage 2 V plastic resin /ABS/PP container epoxy coated exhaust fan to remove the gas emission , suitable rack/stand for continous operation of 30min back up , (b) Float cum boost charger of required rating with regulator including for, trickle charging . (C) control panel with LED indication & alarm annunciation on the panel for main ON, DC ON , charging position , Amp, voltmeter etc.
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar
S & F in replacement of isolator TPN of capacity 100 A, 415V complete as speciefied & directed.
S & F in replacement of isolator TPN of capacity 63A, 415V complete as speciefied & directed.
Comprehensive, preventive and periodical maintance of 01 No . electrically operated passenger lift of capacity 680 kg carrying 10 passengers Make : Johnson, suitable for serving G+5 floors (total 6 landings) with electric power opearted doors, auto electric levelling device complete with ARD facility installed at SRE building to be maintained round the clock as described here-in after in reliable, safe and efficient operating condition by regularly examine lubricating and adjust the mechanical and electrical driving equipment governer, sleeve shaft assembly bearing / contacts & governor jaws,limit switches (car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal fixtures, deflectors, car and counter weight guide rails and buffers, equipment and carry out planned maintenance in a systematic and controlled manner using techniques and expertise consultancy including replacement of spares parts as and when required all as directed and specified to the entire satisfaction of Enginee-in-Charge. Note : AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to Engr-in-charge before starting of work.
Complete survey of the entire electrical distribution networks starting from main receiving station 33/11KV (MRS) in both technical areas and domestic areas to include survey of the facility/plants and their current energy consumption pattern and submit in the form of a comprehensive survey report compising with the following works:-(a) checking the strength of primary/secondary aspects, insulation level, power efficiency and power factor.(b) Bench marking of energy performance and matching of energy use to the requirement, ways to maxim system efficiencies, optimizing the input energy requirement etc.(c) Target to achieve energy cost reduction & identify energy conservation technologies, retrofits energy audit procedure and aligning current consumption with current industry benchmarks.(d) Investigating the existing system to boring out basic five aspects as given below:- (i) How much energy is being consumed (ii) How is the energy being consumed? (iii) What is the energy being consumed? (iv) when is the energy being consumed? (v) what is the quality of the energy consumed? (e) Give recommendations on the basis of the survey report to include cost effective measures to optimise energy resources and methods to achieve maximum energy efficiency of all assets along with BOQ/financial evaluation/specifications/approved brands etc so as to aid in preparation of DPR and conclusion of contracts in near future. NOTE:- Areas covered by electrical energy audit- (i) Complete energy distribution network showing grid substation with all power transformers and distribution transformers.(ii) Analysis of electrical parameters i.e voltage, current, frequency, power factor etc. (iii) Health status of all electrical measuring/controlling and tripping system of MRS.(f) Details of electrical asset are shown in App"A' attached. However the firm interested to bid for the subject work is expected to clear the aspects regarding total assets once again from GE(AF) Sarsawa before submitting the bid and no representation in this regard at the later stage will be entertained.(g). The energy audit will be deemed to considered complete on successful submission of:- (i) Survey report to include specific recommendations on each aspect as brought out above along with approx of GE for final technical check and completion certificate (ii) Full payment against same will be released on completion of job.Appx 'A' :-(1) Electrical Distribution Network & HT Step down Transformer- 34 Nos, (2)EHT/HT Current Transformers /Potential Transformers - 14 Nos, (3) Total Number of HT Breakers -18 , (4) MCCBs/ACBs of different capacities- 150/10Nos , (5) Motors, (Specifying types, Single phase /Three phase) - 15 , (6) Submersible Pump Set (Specifying single phase/three phase) - 20 Nos , (7) Chlorination Plants - 05 dosing pump , (8) Security Lights (Type LED/T-5) ( LED Flood light150w - 333 nos,LED Flood light 100 w- 03 nos, LED Flood light 250w- 118 Nos, LED Flood light 120 W- 505 Nos, LED Street light 60 W-600 Nos, LED Street light 45 W-200Nos , (9) Inductive Load, water supply pump- 435.25 Hp , (10) AHU (Air Handling Unit) -11 Nos , (11) Chillers Supply -01 Nos, (12) HV AC Supply -01 No, (13) DG Sets of different capacities -27 Nos, (14) Servo voltage Stabilizers (3 Phase) - 16 Nos, (15) Three Phase Capacitor Panel (LT) - 09 Nos, (16) Any other electrical items/eqpt/plant which are not mentioned in above is also a part of the work-Lifts - 02 Nos Lift. ADD NOTE:- (i) Work to be carried out through Bureau of Energy Efficiency(BEE) accredited energy auditor having energy audit experience of Govt establishments. (ii) Contractor to submit documentray proof in respect of above for approval of GE before commencement of work
SHRI RAM ENTERPRISES
ISHWAR ELECTRICALS AND PROCESS SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .