Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹22.4 L+₹1.5 L (7.03%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L2 | Rejected-Finance Other than lowest qutoed | |
| 3 | L3₹27.3 L+₹6.4 L (30.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest qutoed |
| Sl No | Description | Qty | Unit | M/S Sahib N Sahiba Enterprises L3 | BHARATI ENTERPRISES L2 | JAYSHREE ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area not exc 0.16 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , over GI wire mesh, giving a coat of anti corrosive paint to exposed Reinforcement and using coat of anti corrosive paint to exposed Reinforcement and using chemical for bonding old and new concrete/plaster and finishing with CM 1:3 plastering, incl 2 coats of white wash to match the exisitng surfaces incl removing debris , necessary scaffolding , etc all as specified and directed. (Note : Reinforcement if any provided shall be measured and paid separately) | 160 | Each Job | 680 ₹1,08,800 | 600 ₹96,000 | 500 ₹80,000 Lowest |
| 2.00 | Description all as per ser item No 01 above herein before but exposed area exc 0.16 Sqm but not exc 0.5 Sqm | 100 | Each Job | 688 ₹68,800 Lowest | 700 ₹70,000 | 700 ₹70,000 |
| 3.00 | M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed . | 100 | RM | 160 ₹16,000 | 150 ₹15,000 Lowest | 200 ₹20,000 |
| 4.00 | M&L Mild steel TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required, incl cranking bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips. | 100 | Kg | 90 ₹9,000 Lowest | 105 ₹10,500 | 90 ₹9,000 Lowest |
| 5.00 | M&L for mild steel 6 - 8mm dia TMT bars bent to shape required, including cranking, bending and binding with mild steel annealed wire not less than 0.9mm dia complete all as specified and directed. | 80 | Kg | 90 ₹7,200 Lowest | 105 ₹8,400 | 90 ₹7,200 Lowest |
| 6.00 | Demolition of cement concrete unreinforced in floors , roof and pavings n. exc 15 cm thickness (below or above ground level). | 18 | Cum | 550 ₹9,900 | 400 ₹7,200 Lowest | 500 ₹9,000 |
| 7.00 | Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete. | 500 | Sqm | 30 ₹15,000 | 20 ₹10,000 | 10 ₹5,000 Lowest |
| 8.00 | M/L rendering 15mm thick (10mm + 5mm)in CM 1:4 in two coats on fair faces of brick work , finished even and fair without using extra cement with WPC. | 500 | Sqm | 130 ₹65,000 Lowest | 255 ₹1,27,500 | 200 ₹1,00,000 |
| 9.00 | M & L preparation of newly plastered surfaces of walls/chajja/lintel and applying two coats of exterior acrylic emulsion paint (Apex or equivalent in berger. johnson paint white or tinted) over a coat of 2 mm wall care putty and alkali resistant primer complete as specified and directed. | 250 | Sqm | 118 ₹29,500 Lowest | 130 ₹32,500 | 120 ₹30,000 |
| 10.00 | M & L for walls of any description by washing, rubbing down and applying two coats of apex paint by over a coat of 2 mm wall care putty and cement primer complete as specified and directed. | 1,900 | Sqm | 124 ₹2,35,600 | 130 ₹2,47,000 | 120 ₹2,28,000 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Feb 2026, 6:00 pmClosed
Shri Manjul Kumar Tripathi, GE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR REPLACEMENT OF DAMAGED ROOFS INCL CHAJJAS FACIA AND ROOF TREATMENT AT KHOJATOLI AND REPAIR MAINT OF EARTHING OF DISTRIBUTION BOXES AT OTM AND MD ACCN AT NAMKUM AND KHOJATOLI AREA UNDER GE RANCHI
2026_MES_751088_1
8200/1684/E8
Open Tender
Civil Works
Item Rate
180 days
GE Ranchi
Class D Cat a (i) b (i)
7 documents required · 7 mandatory
₹500
GE Ranchi
₹60,000
Yes
19 Mar 2026
3 Feb 2026
3 Mar 2026
3 Feb 2026
24 Feb 2026
17 Feb 2026
M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area not exc 0.16 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , over GI wire mesh, giving a coat of anti corrosive paint to exposed Reinforcement and using coat of anti corrosive paint to exposed Reinforcement and using chemical for bonding old and new concrete/plaster and finishing with CM 1:3 plastering, incl 2 coats of white wash to match the exisitng surfaces incl removing debris , necessary scaffolding , etc all as specified and directed. (Note : Reinforcement if any provided shall be measured and paid separately)
Description all as per ser item No 01 above herein before but exposed area exc 0.16 Sqm but not exc 0.5 Sqm
M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed .
M&L Mild steel TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required, incl cranking bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips.
M&L for mild steel 6 - 8mm dia TMT bars bent to shape required, including cranking, bending and binding with mild steel annealed wire not less than 0.9mm dia complete all as specified and directed.
Demolition of cement concrete unreinforced in floors , roof and pavings n. exc 15 cm thickness (below or above ground level).
Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete.
M/L rendering 15mm thick (10mm + 5mm)in CM 1:4 in two coats on fair faces of brick work , finished even and fair without using extra cement with WPC.
M & L preparation of newly plastered surfaces of walls/chajja/lintel and applying two coats of exterior acrylic emulsion paint (Apex or equivalent in berger. johnson paint white or tinted) over a coat of 2 mm wall care putty and alkali resistant primer complete as specified and directed.
M & L for walls of any description by washing, rubbing down and applying two coats of apex paint by over a coat of 2 mm wall care putty and cement primer complete as specified and directed.
Dismantling brick tiles or terracing tiles /roof covering material single layer on roofs complete all as specified
M&L Brushing neat cement slurry (3 Kg of cement per Sq M) mixed with chemical compound in the proportion, chemical compound SUPER LATEX of DR FIXIT of PIDILITE INDUSTRIES LTD, water & cement (1:4:7) or SBR LATEX of STP LTD or other equivalent as per manufacture instructions for bonding of old concrete surface to new concrete all as specified & directed complete.(nOTE: WPC will be measured and paid seperately.)
M&L for 10 mm thick plaster in cement mortor 1:3 laid over roof with integral water proofing admixture @ 200 ml per 50 kgs of cement (after the cement is cured the roof will be testd for water tightness by ponding with water for seven days of any seepage/leakage etc.) Note :- supply only water proofing compound shall be measured and paid separately.
M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:4 for fixing tiles. (Note :- Screed bed shall be mixed with water proofing compound as specified and directed and shall be measured and paid separately)
M&L for 20 mm thick machine cut & polished cement concrete tiles factory made with grey cement without pigment of size 250mm x 250 mm laid in neat cement slurry over screed bed and tiles properly laid with 3 mm wide joints filled with FEVIMATE TG of Dr Fixit or tile glue or as per manufacturer instructions complete all as specified and directed.
Supply only water proofing compound (liquid),ISI marked.
M&L Applying membrane on primed surface by press application method with minimum 75 mm longitudinal wise lap and 100 mm over lap on the transverse direction duly sticked using 3 mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished non woven polyester reinforced (wt not less than 150 grams) over applying one coat of bituminous primer @ 0.4 kg per Sqm complete all as specified and directed.
M&L for two coats of bituminous based aluminum paint on APP membrane all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.50mm aggregates as in padding concrete over the roof slab to bring the slope including forming coving the juction of parape wall and RCC roof slab as directed.
Disconnecting existing tanks setting a side (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position complete all as directed.
Dismantling water tanks capacity exc 500 ltrs & n exc 1000 ltrs and removing from site complete all as specified and directed.
Supply and fixing three layer PVC tank of 500 ltr capacity including Supplied and fixed 20mm dia brass float valve assembly complete all as specified and directed.
S &F Rotational moulded polythene water storage tanks, triple layered (Cylindrical vertical with closed top) of capacity 1000 lit, hoisted and fixed in position as in repair complete all as specified.
S& F Ball brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm as in repairs, complete all as specified and directed.
Taking up or down GI steel tubing in any position and connection including fitting, cleanings for reusing if any as specified and as directed for the following size :-
15mm bore
20mm bore
Supplying and laying of specified outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 with all required fittings ,clipping on walls/ceiling or laying in floors u complete all as specified. for the following size :-
20 mm bore
25 mm bore
S&F in repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed .
S&F in repair for Gun-metal, globe or gate valves 15mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm or GI Strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete all as specified and directed.
Supply and erection of Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound AXIS ULTRA / AXIFILL type Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specified Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values. (vi) Provide the Exothermic welding joints to entire grid system joints of earthing electrod. Make : OBO Betterman/Axis/ UTR
S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised steel wire complete all as specified and directed.
S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x 4 mm dia galvanised iron Strip complete all as specified and directed.
S&F air termination single pointed Aluminium rod 12 mm dia, 300 mm long for lightening conductor including takingdown old one complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. Head screw for fixing in wall complete all as specified and directed.
M&L lightening conductor assembly made out of GI pipe medium grade of size 40 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer, to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified and directed.
M&L GI pipe medium grade of size 40 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer, to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified and directed.
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 38 here in before but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common earth dolly.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.)
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 40 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified.
S & F for Bell push modular 6 Amps single module complete all as specified.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
S & F Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_841207.xls
BOQ • 0.99 MB
Tender1684.pdf
Tender Documents • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .