| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 CrAccepted-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹27.6 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹28.9 CrRejected-AOC | ₹28.9 Cr | L2 | Rejected-AOC Not being lowest bidder |
| 3 | L3₹31.0 CrRejected-AOC NO 157 14 13TH B MAIN ROAD 1ST STAGE PHASE I GOKULA BANGALORE 560 054 | BANGALORE | BANGALORE | KARNATAKA | 560054 | ₹31.0 Cr | L3 | Rejected-AOC Not being lowest bidder |
| 4 | Rejected-Technical UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | - | - | Rejected-Technical Rejected due to adverse remarcks in WLR for QE Jun 2025 |
| 5 | Rejected-Technical UDAYAVANI BUILDING UDAYAVANI ROAD PRESS CORNER MANIPAL 576104 UDUPI D KARNATAKA | UDUPI | KARNATAKA | 576104 | - | - | Rejected-Technical Rejected due to Not fulfill the PQC criteria as per note 1.2.2 of NIT |
| Sl No | Description | Qty | Unit | AFSON ENGINEERS & CONTRACTORS L2 | N RAJEGOWDA and CO L3 | M M SHAWL Engineers and contractors pvt ltd L1 |
|---|---|---|---|---|---|---|
| .50SCHEDULE 'A' PART I Note: This schedule is not pre-priced by MES. | ||||||
| 1.00 | Engineering, Procurement & Construction (EPC) of buildings/ structures as listed in Sch 'A' Part - I as per GRIHA norms including all internal services as defined in Annexure - I to VII complete as detailed in scope of work and other documents of tender, complete all as specified and as directed. | 1 | EACH JOB | 25,10,00,000 ₹25.1 Cr | 25,99,99,200 ₹26.0 Cr | 25,56,00,000 ₹25.6 Cr |
| 1.50Note : Schedule 'A' Part - II to Part XIII are prepriced by MES, Bidders shall insert their lumpsum amount under column 6 only. | ||||||
| 2.00 | Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II | 1 | Lumpsum | 19,77,200 ₹19.8 L | 19,00,000 ₹19 L | 10,50,000 ₹10.5 L |
| 3.00 | Lumpsum price worked out by the tenderer for PROTECTIVE WORKS as listed in Schedule ‘A’ Part-III | 1 | Lumpsum | 22,00,000 ₹22 L | 26,62,784 ₹26.6 L | 13,00,000 ₹13 L |
| 4.00 | Lumpsum price worked out by the tenderer for ROAD/ PATH/ HARD STANDING/CULVERT as listed in Schedule ‘A’ Part-IV | 1 | Lumpsum | 82,65,000 ₹82.7 L | 77,00,000 ₹77 L | 47,00,000 ₹47 L |
| 5.00 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V | 1 | Lumpsum | 12,00,000 ₹12 L | 13,51,610 ₹13.5 L | 12,87,248 ₹12.9 L |
| 6.00 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI | 1 | Lumpsum | 12,75,000 ₹12.8 L | 13,86,597 ₹13.9 L | 13,50,000 ₹13.5 L |
| 7.00 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII | 1 | Lumpsum | 5,80,000 ₹5.8 L | 5,19,919 ₹5.2 L | 4,72,654 ₹4.7 L |
| 8.00 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VIII | 1 | Lumpsum | 36,00,000 ₹36 L | 30,42,946 ₹30.4 L | 17,66,315.02 ₹17.7 L |
Updated dates
Tender Value
₹30.3 Cr
EMD Value
₹15 L
Closing Date
5 Mar 2026, 6:00 pmClosed
CE Chennai Zone
CE Chennai Zone, Island Ground, Anna salai
ENGINEERING, PROCUREMENT AND CONSTRUCTION EPC FOR PROVISION OF QUARANTINE AREA ALONG WITH INFRASTRUCTURE AND ALLIED FACILITIES SPECIAL WORK AT BANGALORE
2025_MES_746741_1
88570/E8
Open Tender
Civil Works
660 days
BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Garrison Engineer P Bangalore
₹15 L
Yes
30 Apr 2026
31 Dec 2025
12 Mar 2026
1 Jan 2026
5 Mar 2026
19 Feb 2026
7 Jan 2026 - 14 Jan 2026
SCHEDULE 'A' PART I Note: This schedule is not pre-priced by MES.
Engineering, Procurement & Construction (EPC) of buildings/ structures as listed in Sch 'A' Part - I as per GRIHA norms including all internal services as defined in Annexure - I to VII complete as detailed in scope of work and other documents of tender, complete all as specified and as directed.
Note : Schedule 'A' Part - II to Part XIII are prepriced by MES, Bidders shall insert their lumpsum amount under column 6 only.
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for PROTECTIVE WORKS as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for ROAD/ PATH/ HARD STANDING/CULVERT as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for SECURITY WALL, STEEL GATE & FENCING as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for COOLING APPLICANCES as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-XIII
SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES.
Supply & Laying of 150 mm internal dia DWC HDPE SN-8 pipes confirming to IS 14930 part 2/IS 16025 part-24, laying including all necessary specials, cutting and joining as specified and directed.
Supply & Laying of 200 mm internal dia DWC HDPE SN-8 pipes confirming to IS 14930 part 2/IS 16025 part-24, laying including all necessary specials, cutting and joining as specified and directed.
M&L for Centrifugally cast(Spun) Ductile Iron pipes with socket & spigot end centrifugally, class K-7 conforming to IS: 8329:2000 marked with and including Rubber Gaskets used with Push -on -jointing confirming to IS 5382 in any length laid in trenches with including all fittings of size 100 mm dia bore all as specified.
Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 300 LPM at 26 Mtr head, squirrel cage TEFC induction motor 3 phase, 415V AC,50 Hz suitable for delivery 300 LPM at 26 Mtr head coupled on common base chanel including necessary PCC foundarion works, nuts and bolts, copper cable from starter to motor through PVC flexible pipe , suitable size of suction pipe not less than 20 feet or as reqd at site, normax type Foot valveof suitable size, Air release valve of dia 25mm complete of Kirloskar Model KDS 527++ or equivalent all as directed and specified
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in any kind of soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M & L for excavating the soil above pipe line at tapping point without damaging the pipeline, cutting of existing CI/DI pipe of 150 mm dia and inserting tee of size 150 x 150 x100 mm including necessary rubber gaskets for jointing and connecting to 100 mm dia DI pipe, refilling the excavted sand all as specified and as directed.
M&L for construction of valve chamber 900x900x900 mm depth with PCC foundation in the ration 1:4:8 brick work cement mortar in the ratio 1:4 using of class B bricks , PCC coaping at the top of the ratio 1:2:4 , plastering 15 mm thick in the ratio 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint all as specified and directed . (Earth work shall be measured and paid seperetely in the respective items)
(i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps (ii) MCCB 4 Pole 63 Amps 25 KA-01 No ( Incoming) (iii) MCB 4 Pole 32 Amps 10 KA- 02 No (iv) MCB SPN 16 Amps 10 KA -01 No (Street Light) (v) Timer switch Single phase with duty contactor 16/ 20 amp - 01 No (vi) Provision for DOL Starters for Pump house - 02 nos (vii) LED phase indication lamp for 3 phase-01 No
Fabricate, supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50 X 50 x 6MM MS angle, 3 Phase 4 wire, 440 V, AC 50 Hz with TPN aluminium bus bar of Capacity 400 Amps with PVC heat shrink colour code sleeves, mounted on porcelin insulators complete volt and Amp meter, slector switch with all accessories , Fire sniper system and necesssary piping and control system and consist of the following switch gear (Annex-1 Building Lights) :-
(a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps. (b) MCCB 4 Pole 160 Amps 25 KA O/L, S/C & S/T Release -01 No (Incomming) (c) MCCB 4 Pole 100 Amps 25 KA with O/L, S/C Release - 03 No (d) MCCB 4 Pole 125 Amps 25 KA with O/L, S/C Release - 1 No (e) MCB TPN 20 Amps 10 KA- 2 No (f) MCB SP 32 Amps 10 KA- 3 No (g) LED phase indication lamp for 3 phase-01 No (h) Multifunctional meters 3 phase showing : Volts, Currents, Frequency, PF, KW, KVA and KVAR
Fabricate, supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50 X 50 x 6MM MS angle, 3 Phase 4 wire, 440 V, AC 50 Hz with TPN aluminium bus bar of Capacity 400 Amps with PVC heat shrink colour code sleeves, mounted on porcelin insulators complete volt and Amp meter, slector switch with all accessories, Fire sniper system and necesssary piping and control systemand consist of the following switch gear (Annex-2 Building Lights) :
(a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps. (b) MCCB 4 Pole 200 Amps 36 KA O/L, S/C & S/T Release -01 No (Incomming) (c) MCCB 4 Pole 100 Amps 25 KA with O/L, S/C Release - 01 No (d) MCCB 4 Pole 63 Amps 25 KA with O/L, S/C Release - 03 No (e) MCB TPN 20 Amps 10 KA- 2 No (f) MCB SP 32 Amps 10 KA- 3 No (g) LED phase indication lamp for 3 phase-01 No (h) Multifunctional meters 3 phase showing : Volts, Currents, Frequency, PF, KW, KVA and KVAR
Fabricate, supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50 X 50 x 6MM MS angle, 3 Phase 4 wire, 440 V, AC 50 Hz with TPN aluminium bus bar of Capacity 400 Amps with PVC heat shrink colour code sleeves, mounted on porcelin insulators complete volt and Amp meter, slector switch with all accessories, Fire sniper system and necesssary piping and control system and consist of the following switch gear (AC Panel 1 ) :-
(a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps. (b) MCCB 4 Pole 315 Amps 36 KA O/L, S/C & S/T Release -01 No (Incomming) (c) MCCB 4 Pole 100 Amps 25 KA with O/L, S/C Release - 01 No (d) MCCB 4 Pole 160 Amps 25 KA with O/L, S/C Release - 01 No (e) MCB TPN 20 Amps 10 KA- 2 No (f) MCB SP 32 Amps 10 KA- 3 No (g) LED phase indication lamp for 3 phase-01 No (h) Multifunctional meters 3 phase showing : Volts, Currents, Frequency, PF, KW, KVA and KVAR
Fabricate, supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50 X 50 x 6MM MS angle, 3 Phase 4 wire, 440 V, AC 50 Hz with TPN aluminium bus bar of Capacity 400 Amps with PVC heat shrink colour code sleeves, mounted on porcelin insulators complete volt and Amp meter, slector switch with all accessories,Fire sniper system and necesssary piping and control system and consist of the following switch gear (AC Panel 2 ) :-
(a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps. (b) MCCB 4 Pole 315 Amps 36 KA O/L, S/C & S/T Release -01 No (Incomming) (c) MCCB 4 Pole 100 Amps 25 KA with O/L, S/C Release - 01 No (d) MCCB 4 Pole 160 Amps 25 KA with O/L, S/C Release - 01 No (e) MCB TPN 20 Amps 10 KA- 2 No (f) MCB SP 32 Amps 10 KA- 3 No (g) LED phase indication lamp for 3 phase-01 No (h) Multifunctional meters 3 phase showing : Volts, Currents, Frequency, PF, KW, KVA and KVAR
Design ,manufacture supply, install ,test and commission Automatic Power Factor control panel 250 KVAR capacitor bank in 6 steps as indicated below with microprocessor best controller units suitable for operation on AC 415 V , 50 Hz ,supply, suitable for installation outdoor wheatherproof type, frontr with hinge type door and locking arrengement bottom with detachable sheets for cable entry/exit , top with sloping caonopy fabricated with 3.15 mm thick MS sheets suitable size to install following switchgears/items,powder coated both inside and outside, complete npanel board install on suitable PCC pillar with bolts and nuts grouted to pilars and comprising following switchgear/capacitors control gear etc. all as specified and as directed as follows :
(a) Incomer MCCB TPN 400 Amps 35 KA - 01 No (b) Current Transformer 400/5 Amps - 03 Nos (c) Alluminium bus bar insulated TPN 400 Amps - 01 set (d) Capacitors 50 KVAR super heavy duty long life for industrial load - 04 Nos , 25 KVAR -02 Nos. Including suitable capacities contactors, MCBs ,Fuses,Relays,Digital type indicating meterss for voltage,current,PF etc complete internally prewired with copper conductor.
Supply and fix FRP pole box of size 168X253x115mm ,thermoplastic,polycabonate,IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos,MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified
Material and labour for street light bracket made of 40mm GI pipe light grade 1.5 m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed..
S&F cable route indicator Oval shape 200x150x6mm cast iron fixed on 25x25xx6mm angle iron incuding marking of HT/LT UG Cable duly painted and grouted in PCC complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology sing ultra sonding techinques and necessary machines including HDPE pipes of 150 mm dia suitable for 0.4MPA working pressure complete all as specified and directed.
Supply, installation, Testing and commissioning of Compact Sub Station out door type with PCC foundation as recommended by OEM for installation complete all as specified and directed. The 11 KV Outdoor Package Sub-Station Shall be consisting of Followiing :- (A) HT SWITCHGEAR :- (i) 11kV 630Amps 21kA for 3 sec. SF6 insulated Non-Extensible Compact Switchgear consisting of Two Nos. Manual operated Load Break Switches and One No Manual operated Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure of thickness 2.5mm with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection with 1 no. Metering compartment . Interconnection between HT switchgear and transformer shall be using up to 1C x 3 x 95 sq.mm Al. unarmoured XLPE Cable (ii) Relay shall be self powered non communicable( 50,51,50N,51N) -01 No (iii) Protection CT: 40/1 Amps, 2.5VA, 5P10 (For Protection)- 03 Nos (iv) Voltage Presence Indication for Incoming Supply Healthy Indication 03 Nos (v) Fault passage indicator for C Module- 01 No
(vi) ON/OFF/TRIP Mechncial indications on front Mimic for Breaker - 03 Set (vii) Manometer - 01 No (viii) Operating Handle - No (ix) Right Angle Boots as loose as cable teminal protector - 2 Sets (x) Incoming & Outgoing Cable Box of the RMU shall be suitable for cable termination of upto 3C x 300 sq.mm Al cable, incoming cable & termination kits shall be in scope of contractor (B) TRANSFORMER :- TRANSFORMER of indoor type (Manufactured as per IS 1180 Level 2/ star 2 ) TYPE:- ONAN, Hermetically sealed corrugated tank and without conservator type design. i) Ratio- 11 KV/433V, ii) Capacity:- 500 KVA, iii) Vector Group- DYn11, iv) Off Load Tapping’s +5% to -5% in steps of 2.5% v) Winding- Copper vi) Class of Insulation- A vii) Ambient Temperature- 50 Deg C,
viii) Temperature rise in oil over ambient- 40 Deg C ix) Temperature rise in winding over ambient- 45 Deg C x) Losses at 50% loading – 1430 Watts xi) Losses at 100% loading - 4100 Watts xii) %Impedance – 4.5% (Make: Powerstar/OEM Approved vendors) Wingding temperature Indicator with Alrm and Trip. Transformer Door interlock with the breaker (C) LVS PANEL:- 800 AMPS ALUMINIUM BUSBAR ( FOR PHASE 100% AND NEUTRAL 50%) Having IP2X LT panel made up of 1.5mm/2mm thick CRCA sheet
(D) INCOMER FROM TRANSFORMER (i) 800 AMPS 433V 4P 50KA Manual fixed ACB with microprocessor Based over current, short circuit protection - 1 No. (Incomer) Out going :- (ii) 400 AMPS 433V 4P 50KA Manual fixed MCCB with microprocessor Based over current, short circuit protection - 1 No (iii) 100 AMPS 433V 4P 25KA Manual fixed MCCB with microprocessor Based over current, short circuit protection - 2 No (iv) 200 AMPS 433V 4P 25KA Manual fixed MCCB with microprocessor Based over current, short circuit protection - 1 No (v) 320 AMPS 433V 4P 25KA Manual fixed MCCB with microprocessor Based over current, short circuit protection - 1 No (vi) LED Type Indicating Lamps RYB Phase and ON-OFF-TRIP - 01 Sets (vii) Digital Multi Function Meter, CI-0-5 with RS 485 Port - 1 Nos (viii) LT Current Transformer -800/5 Amps 5VA Class-0.5 - 04 Nos
(E) OUTDOOR ENCLOSURE :- Outdoor type enclsure having consturction of Galvanised Sheet steel of thickeness 2mm for load bearing member and 1.5mm for Non load bearing member with 4mm HRCA base frme . The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment . The enclosure exterior shall be Powder Coated (Colour as per OEM). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV and LV compartment.
(F) INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 1C x 3 x 95 Sq.mm Aluminum unarmorured XLPE Cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars with Aluminum Flexibles. Internal earthing connections including transformer neutral by using 50 X 6 GI strips. (G) PLINTH :- The PCC Foundation flatform shall be at least 1mtr extended from all side of RMU unit. Mininmum height of PCC Foudation shall be 30cm from the ground level. (H) PAINTSHADES : Duly powder coated as recommended by OEM of approved colour over a coat of primer.
(J) NOTE -1:- i) The Compact substation shall be tested for internal arc test IAC –AB for 21KA for 1 sec (A-operator, B-pedestrian). This has to be validated by Type test certificate as per IEC 67721-202. ii) CSS offered by System House / Joint Venture/ Franchise partners of OEMs shall not be accepted. iii) CSS design, invoicing, ownership, Service responsibility & warranty shall be of OEM on whose name all Type tests are issued. Type tests shall be conducted on CSS as per IEC 62271-202 in the name of OEM. iv) CSS, RMU, Vacuum Interrupter, ACB/MCCB shall be of same OEM make for better reliability, performance and service support and overall life cycle optimization. v) CSS manufacturer shall fulfill temperature class K10 as per IEC 62271-202
Supply, installation, testing and commissioning of 500 KVA / 400 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of KOEL 500 KVA or equivalent, developing 604 BHP @ 1500 RPM, water Cooled V-Type 12 cylinder 4 stroke, turbo charged after cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, with emission control device to control the PM within range as prescribed by NGT/ norms published vde GSR 804(E) dt 03.11.2022 of GoI and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition at Bangalore with integral fuel tank with battery and leads and accessories complete iincluding required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions:-
(B) Diesel Engine: - Adequate capacity Diesel engine suitable for 500 KVA coupled drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GMMCO).
(a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts. (c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade up to and away two meters height from top of enclosure including necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminum sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas : Turbo charger type Exhaust manifold Silencer: Residential type Bellows
(C) Fuel System :- Fuel injection system with fuel injectors, fuel injectionsolenoid switch/nozzles/ governor elctrionic type capable for 1 % speed /frequency regulation. (i) Fuel filters (ii) Fuel hoses (iii) Lub oil System :- (iv)Lubricating oil filter (v) Lubricating oil pump (vi) Air Intake System :- (a) Air intake Manifold (b) Air cleaner dry type (a) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator. (b) Batteries:- 2No.s Maintenance free Battery of suitable AH capacity complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified. Make:- EXIDE / AMRON / Produced by original DG set manufacturers
(i) Starter gear ring (ii) Start and stop push button (iii) Ignition key / Switch (iv) Handling and operation: Salient features of accessories shall be as under: (a) Radiator with blower fan (b) Corrosion inhibitor coolant (c) Paper element filters for fuel, lub oil and by pass. (d) Electronic governor controlled direct fuel injection system (e) Fly wheel housing and fly wheel.
(E) Generator Monitoring Panel: Comprising of following:- (a) Microprocessor based integrator generator set monitories, metering, protection and control system with built torque matched volts/H3 over load control. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annunciations (e) Cyclic cranking (f) Auto/manual start stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity up to 95% (j) Remote monitoring capability through separate interface modules
k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor (l) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine. (m) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing. (n) Accessories :-A VM Pads built or separately mounted to manufacturer base frames. (o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (p) Fuel Tank :- Daily service fuel tank of capacity minimum 08 hrs running storage (Inbuilt) made out of 3mm thick (Heat Retardant) sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built inside the acoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design.
(q) Deliverables:- Confirms the norms established by CPCB.(F) AMF PANEL:- (a) Auto Main Failure (AMF) panel made out of 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminum bus bar capacity required to carry current at 100% load of 500 KVA DG set with three phase and half neutral color coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel:(i) 800 Amps, 4 pole ACB - 2 Nos. (ii) MCCB, 4 Pole 400 Amps, 50 KA-3 Nos (iii) MCCB, 4 Pole 250 Amps, 50 KA-2 Nos (iv) MCCB 4 pole 100 Amps 1- No (v) CTs 50/5A for both the supplies. (vi) DC Ammeter. (vii) DC Voltmeter. (viii) Push buttons. (ix) Indication Lamps. (x) 2 over load+ earth leakage relay.
(xi) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency,power factor etc. (xii) SMPS Battery charger 12V, with trickle & Boost charging (xiii) On/ Off switch. (xiv) Automatic/manual switch. (xv) Hooter. (xvi) Voltage sensing relay. (xvii) Six window enunciator for fault indications. (xviii) Electro magnetic relays. (xix) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz.
(G) EXHAUST STACK STRUCTURE SUPPORTS: Supply, designing, fabrication and installation stack structure for exhaust pipe supports of DG sets with piant alongwith two coats of red oxide and one coat afterward with paint as per the approved colour. Before fabricating, the contractor has to get the design approved from the GE /CWE. The exhaust structure shall be for 1no. 500KVA DG set.Supply, erection, testing and commission of MS class B NB 150 mm minimum 4.85 mm thick with complete bends & flanges and all accessories complete in every way.Supply, erection & insulation of above pipe with RBS wool of min 75mm. thickness 96 Kg/m3 density and 24 SWG Alm cladding outside. Insulation will be done in such a way that temperature surrounding it shall not exceed 70°C beyond ambient. The vendor shall carryout calculation and shall use minimum ratings given above of dia 150 mm NB pipe Flexible Bellows For Exhaust System. Supply and fixing of SS expansion joints for following exhaust pipes of size 150mm NB
(H) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:- (a) Custom built product for various equipments, with ensure the optimum performance without duration. (b) Rugged in construction maintenance free and modular designs which facilitate easy at site.
(c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (d) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (e) Special paint treatment with pure polyester powder/epoxy to be provided for better weather resistance. (f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (h) Working space is to be provided around tube equipment for easy maintenance / repairs.
(j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. (k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (m) Deliverables. 75 dBA @ imtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. (n) The enclosure should be provided with bulk head light fitting for inside illumination (o) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (p) The DG Set should be provided with external Emergency stop push button. (q) The acoustic enclosure parts shall be of powder coated after pre treatment process.
S&F Refrigerator electrical driven Single door (single phase) capacity Min 215 ltrs BEE 5 star rated inverter technology suitable for operation on 230v 50HZ AC all as specified and directed. Make: Samsung Model:RR23D2H359U or equivalent
Supply, install, commission and testing of Deep freezer glass top up to 315 litre capacity 5 star having single door.electric driven with stabilizer free operation with range 160V- 260V, 50Hz AC supply, refrigrant R290, all as specified and as directed. Make : Blue star NPSERIES or equivalent
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% for 2.0 TR Air conditioner all as specified and as directed. Make: V-Guard VgG00 or equivalent
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% for 1.5 TR Air conditioner all as specified and as directed. Make: V-Guard Vg400 or equivalent
Planting of well grown trees of height 2.4m and above and 2 to 21/2 yrs old with proportional girth of ever green and or shady species alongwith spiked stackes not less than 2.75m in height Neem etc complete
All as per item No.37 above but Mango
All as per item No.37 above but Ashoka
All as per item No.37 above but Chikko
All as per item No.37 above but Royal Palm
M&L for Developing Lawn which includes necessary earth work excavation to a depth of 30 Cms in all types of soil, removal of all construction debris, weeds, leveling and applying of soil pesticides, transplanting of Bermuda Grass, planting, routing etc complete all as specified and directed.
SHRUBS:- Providing and developing shrubbery by digging pits 0.5mx0.5mx0.5m and filling with sand manure, red earth in the proportion of 1:2:5 planting with varieties Shrubs etc complete. (a) Masanda
All as per Item No.43 above but Exora
All as per Item No.43 above but Rose
Maintance of well developed plants/grass/tress provided vide SI items no 01 to 03 by engaging well experience Gardener minimum 01 No per day all as specified and as directed. The maintanance shall include the following: (a) Periodical de-weeding of unwanted vegitations growth around the plants/lawn area (b) watering all the trees/plants/lawn areas as required for proper growth (c) Periodical lawn mowing (d) Periodical pruning the shrubs (e) Treating the tress/pants/grass and soil with required quantity of approved manure, pesticides and fertilizers including necessay topping of red earth (f) Replacement of dried/dead plants/grass/tress
Note: (i) The works covered under this item shall immediately commence from the next date of completion of phase I works issused by GE and shall run for period of 02 years. (ii) The rate quoted shall be deemed to include the cost of manure, pesticide and fertilizers,cost of plants required for replacement of dried/dead plants/grass/treesand cost of red earth for topping up.(iii0) W ater shall be supplied free of cost for maintance only of well developed plants/grass/trees provided vide SI item NO's 1&9. However the contractor has to make necessary arrangements for irrigation from the water point given by suitable method at site without any extra cost to the department.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tenderdocuments.pdf
Tender Documents • 12.59 MB
DRAWINGS.rar
Additional Documents • 1.53 MB
BOQ_836204.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid