Extension of new washing line at Bikaner & Enhancement of Electrical Maintenance Facilities over BKN division with improvement in pit / catwalk lighting system.
26-El-BKN-E-Tender-25-26~NWR
26-El-BKN-E-Tender-25-26
Open
Works - General
10 Months
Bikaner, Rajasthan
₹0
₹3.3 L
16 Dec 2025
24 Nov 2025
2 Dec 2025
GSM showing over all electrical installation at site as per requirement.
complete with 3P 80A MCCB, 63A 5 pin coupler (male + female) and accessories as per specification and drawing. MCCB and coupler should be of reputed make and as per tech. spec.
box two ways outdoor type as per RDSO Drg.No. SKE-3929 as per specifications.
N + E) with 63A MCB for ON/OFF for welding with enclosure as per site requirement.
MS flat 35x5mm as per technical specification.
Description:- Providing SH rail post 1.5 / 2.5 mtrs. Long for Precooling / Charging. Work includes cutting of 50 / 60 / 75 / 90 lbs capacity rails in pieces of desired length (1.5 / 2.5 mtrs.), digging of pit
concerned SSE). The rail pole shall be erected over a cement concrete bed (1:3:6) of 15 cm thickness and back filling of pit with excavated earth soil. The depth of the pit shall be 0.5 mtrs. or as directed by Site Engineer. These rail poles should be grouted properly.
7 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY 7 Description:- Laying, connecting, testing and commissioning of 4x120 sqmm, 1.1 kV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench / pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
insulated PVC outer sheathed aluminium conductor armoured cable in trench / pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
insulated PVC outer sheathed aluminium conductor armoured cable in trench / pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
Description:- Drilling of horizontal bore below Track/Road by trenchless technology for laying of RCC
necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion.
road. The work involves laying of HDPE pipe along with transportation of pipe.
Description:- Supply, installing, testing and commissioning earth electrode complete in all respect with perforated GI pipe medium "B" class (Blue) confirming to IS 1239 part-I length of 4 mtr., bore
covered by CI/RCC frame etc. Digging pit and refilling it with charcoal and salt in successive layers and connection with 25x3 mm GI strip and as per IS:3043 and drawing and testing of earth resistance as reqd.
Description:- Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP
model no. GSJB 3525 or similar with 4 no. aluminium busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole / wall as per requirement. All the material should be of good quality.
Description:- PIT LIGHTING: Design, fabrication, supply, erection, testing & commissioning of LED based luminaire having input voltage 40V-72V AC, frequency 50/60 Hz, Input Power 16 Watt with IP-
a way to illuminate the under frame of the coach and path lighting of pit line. The cubicle shall be fabricated with MS sheet / Poly carbonate body with high built of epoxy coating, heat resistive up to
specifications.
Description:- CAT WALK LIGHTS: Design, fabrication, supply, erection, testing & commissioning of LED based Cat walk lighting luminaires complete, with input wattage of 22 Watt suitable to work on
Luminaries should be Ingress protection IP- 67 & Impact protection IK-10. The cubicle shall be fabricated with MS sheet / Poly carbonate body with high built of epoxy coating, heat resistive up to
IRGOLD-B1 of M/s Goldwyn Limited or equivalent as per specifications.
VPI dry type transformer with suitable size enclosure as per tender specification & site requirement.
Description:- Supply and fixing of HOT DIP GALVANISED RIGID STEEL CONDUIT PIPES (HIGH
and with galvanized clamps & GI junction boxes as per site requirement. The box should have IP-67 protection.
and suitable for pit / cat walk light arrangement.
BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY
Unarmoured copper cable ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
Description:- Supplying and drawing 4.0 sq. mm PVC insulated multistrand copper conductor cable
earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec.
Description:- Supplying and drawing 6.0 sq. mm PVC insulated multistrand copper conductor cable
earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec.
Description:- Supply & erection of 5 m high with double arm model no. BOP-5030 of Bajaj or similar, pole shaft material S355J0 or equivalent as per IS, hot dip galvanized steel octagonal pole with
mounting inside the base compartment of pole), foundation bolt size 4x16mm dia. 600 mm in length including excavation and making foundation as per spec. and drawing. It shall be galvanized internally and externally by single dipping method. The pole and foundation shall be made as per specification and attached drawing.
charge of railway.
insulated PVC outer sheathed aluminium conductor armoured cable in trench / pipe as per spec. including transportation (HDPE pipe will be supplied by Railway).
insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
mm, PN 6, PE 80 as per requirement.
under the road. The work involves laying of HDPE pipe along with transportation.
kuchha / pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer.
beam ISHB 150, size 150mm x 150mm of length 10.0 Mtrs. with required foundation and painting etc. (As per specification)
Description:- Supply, fixing, connecting and charging of off load type Gang operated 3 pole switch
hardware copper moving and fixed contact, assembly of 9 nos. pin insulator, GI pipe of suitable length of operation including 3 nos. vertical mounted 11kV horn gap fuse set/dropout 11kV barrel drop out fuses mounted on 6 no. pin insulator as per standard spec. on existing H pole.
Description:- Supply, fixing, testing, commissioning of 11kV / 750V Package Substation consisting of
LT side I/C of 1X1600A ACB, B/C 1X1600A ACB & O/G 3X800A ACB suitable for 750V with accessories and including civil foundation work for mounting CSS, cover shed for CSS and fencing as per site requirement and complete CSS to be as per tender specification.
Description:- Provision of Supply, fixing, testing and commissioning of Feeder Pillar Panel with
protection device, indication, MFM meters and Feeder socket box with ZS female socket 500Amp and as per site requirement and clearance available at site.
BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY Description:- Provision of Design, manufacture and supply, fixing, testing &commissioning of 11 KV HT Switch board 350 MVA, 630A, HT VCB incoming/ outgoing type motorized operated panel complete
A-meter, selector switch, clustered LED type indication lights, double ratio 60/30/5A copper wound current transformer for incoming panel &outgoing ratio 30/15/5A copper wound current transformer for outgoing panel and suitable cable end box etc. as per IS, IE rules, Tech Spec and site requirement.
size 150 sq. mm grade voltage 1.8/3.0KV and confirming to RDSO spec no. ELRS/SPEC/ELC/0019 Rev- 3, Feb 2017 or latest at Tech Spec relevant IS / IE Rules and site requirement.
size 95 sq. mm grade voltage 1.8/3.0KV and confirming to RDSO spec no ELRS/SPEC/ELC/0019 Rev-3, Feb 2017 or latest at Tech Spec relevant IS / IE Rules and site requirement.
Phase, 50Hz complete 1 set for LHB coaches conf. to RDSO spec no. RDSO/PE/Spec/AC/0177 (Rev-(0)
Description:- Laying, testing & commissioning of 11KV / 33KV XLPE cable in air / ground / in trench / spun / HDPE pipe, with transportation from main depot to required site, and as per specification
collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Cost of these provisions is deemed to be included in the quoted rate for this item.
insulated PVC outer sheathed aluminium conductor armoured cable in trench / pipe with transportation as per spec. & site requirement.
equivalent of M/S Harting suitable for HOG LHB power car as per RDSO/PE/MS/AC0051-2011 Rev-2 or latest accepted make - SCHALTBAU or similar.
Output Voltage: 110V DC, 5A Output voltage: Adjustment Range: ±20%, Protections: Overload / Over Voltage / Short Circuit, Auto-Recovery After Protection.
Description:- Supply of 16 core X 1 Sqmm Teflon insulated copper cable (PTFE) with PVC sheathed
per RDSO/PE/MS/AC/0051-2011 Rev. 2 or latest Make - Geecore part no. HOR002422 JSSS1034 (PTFE/SCR/FRLS) or equivalent.
outdoor type suitable for Cable Size 120-185 sq.mm as per specification & site requirement.
per requirement.
work involves laying of HDPE pipe along with transportation.
Kachha / Pakka land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer.
Description:- Cutting of cement concrete floors (PCC / RCC), any type / depth as required for laying of UG cables in trenches and disposing off the excavated material as directed including refilling the
barricading and danger lighting around the excavated area as safety precaution is a mandatory requirement and cost of this provision, wherever required, is deemed to be included in the quoted rate of this item.
BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY
1.5mm thick size 150X100mm welded with 12mm dia MS rod 85 cm long. The lower end of rod should be turned in hooks shape and attached with the cable at the time of laying as per specification & site requirement.
RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest.
RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest.
Description:- Supply, installing, testing and commissioning of copper plate earthing with connection
charcoal and salt and connection by copper flat. Masonry enclosure of 40 x 40 x 30 cm (inner), 12.5cm should be provided at the top of the pit as per drawing and IS: 3043.
earth with equipment as per site requirement.
I for passing incoming and outgoing cable from ground through it size 38 mm dia. Pipe should be of reputed make and as per tech. spec.
I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make and as per tech. spec.
I for passing incoming and outgoing cable from ground through it size 100 mm dia. Pipe should be of reputed make and as per tech. spec.
Switched Power Factor Correction System with 7% Harmonic Block Reactor as per tender specs.
Description:- Supply and fixing of junction box size 500x450x100mm comprising of sheet steel 2mm
gland plates, neoprene EDPM/rubber gasket, padlock arrangement, zinc passivated earth bolt, canopy etc. with 4nos. aluminium busbar cap 200 Amp., suitable for 415 Volt supply requirement. The box shall be robust with clamps for mounting at pole / wall as per site requirement.
type, extensible type Ring Main Unit (RMU) with suitable RCC foundation with 2 Nos. Load Break Switch (LBS) & 1 No. Vacuum Circuit Breaker (VCB) as per specification.
another location complete in all respect as instructed by Site Incharge.
accessories, T&P and connections. (Scope does not include CC foundation). Note: The final commissioning of substation includes submission of all technical documents as specified and directed.
Description:- Material and labour for Construction of concrete masonry plinth below ground level with M10 concrete for compact substation with provision for HT and LT cable incoming / outgoing
and got approved from Railways prior to commencement of work at site. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision.
62 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY Description:- Material and labour for Construction of concrete M20 masonry plinth above ground level with plastering for compact substation with provision for HT and LT cable incoming / outgoing including excavation and refilling as required. Note: (i) The foundations drawings shall be submitted and got approved from Railways prior to commencement of work at site. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision.
Description:- Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core
conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (with modular switch, celling rose, PVC conduit & chase work) as per spec.
modular board and wiring with 2.5sqmm PVC Cu cable as per spec.
with modular board and wiring with 4.0sqmm PVC Cu cable as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
-plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
wire in PVC conduit concealed and 4.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
wire in PVC conduit concealed and 6.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
Description:- Supply, installation, testing and commissioning of SPN DB 12 Way with suitable IP
MCB, 10 kA, 'C' curve in the outgoing as required with bus bar, neutral bar and necessary wire sets as per specification.
accessories, as per IS:9537, reputed make with High mechanical stress (HMS) type including fixing accessories.
made good in all respect and satisfaction of Engineer Incharge.
Description:- Supply and fixing of Double Door MCB TPN DB SP (8+12 module), neutral and earth
SP MCB 32/25/16/10/6Amp 'C' series. Breaking capacity not less than 10kA. MCB, RCCB and DB should be as per tech spec. and of same make.
77 Description:- Fixing of LED four feet fitting complete as per site requirement.
BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY
made of MS sheet 1.6 mm thick size 600mmX300mmX600mm with suitable MS stand copper bus bar of 200 Amp capacity and 2X63 Amp MCB four pole as per technical specification. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () B-Construction of Outpit and allied work at Bikaner depot. 2654193.00
GSM showing over all electrical installation at site as per requirement.
Description:- Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core
with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (with modular switch, celling rose, PVC conduit & chase work) as per spec and site requirement.
modular board and wiring with 2.5sqmm PVC Cu cable as per spec.
with modular board and wiring with 4.0sqmm PVC Cu cable as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
-plug with sheet metal box of good quality concealed fixing of MS / PVC as per spec.
wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
wire in PVC conduit concealed and 4.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
wire in PVC conduit concealed and 6.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement.
Description:- Supply, installation, testing and commissioning (with foundation / supporting structure) of 200 W LED circular high bay with toughened glass fitting with glass cover suspended
cat no. CIP-325-200-57-60D-HL5-LM-NSG of Crompton or equivalent make with suitable junction box for main supply in each row & looping complete in all respect as per site requirements. Reputed make like Crompton / Philips / Wipro / Bajaj / Orient / Havells / Surya. Minimum warranty of 5 years.
instructions of Rly Supervisor.
15 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY Description:- Supplying, fixing and commissioning of street light fitting accessories e.g. GI pipe of bore 25mm or as suitable for street light, clamps, nuts, bolts, cable, etc. as per instruction of site engineer.
Description:- Supply and fixing of 250 Watt LED Flood light with required fixing arrangement,
for LED (Minimum 50,000 burning hours), THD < 20. Reputed make like Crompton / Philips / Wipro / Bajaj / Orient / Havells / Surya. Minimum warranty of 5 years.
Description:- PIT LIGHTING: Design, fabrication, supply, erection, testing & commissioning of LED based luminaire having input voltage 40V-72V AC, frequency 50Hz / 60Hz, Input Power 16 Watt with IP-67 enclosure & Impact protection IK-10 with High brightness, high intensity with efficiency of 130
such a way to illuminate the under frame of the coach and path lighting of pit line. The cubicle shall be fabricated with MS sheet / Poly carbonate body with high built of epoxy coating, heat resistive up to 70 degree centigrade complete with weather proof and rust proof. Complete fixture shall be as per tender specifications.
transformer 230V / 40-72 Volts outdoor type with suitable enclosure and mounting arrangement as per specs & site requirement.
& night ON & OFF Photocell device QS-302 LDR sensor switch for lighting.
reputed make. It includes installation of fan along with required accessories as per site requirements.
Description:- Supply and fixing of TPN MCCB double door DB 12+2 way with 01 No. 4P MCCB 100A
bar, neutral bar and necessary wire sets as per specification. The MCCB, MCB, RCCB and DB should be as per tech spec. and of same make.
Description:- Supply, installation, testing and commissioning of SPN DB 12 Way with suitable IP
10-32 Amp. SP MCB, 10 kA, 'C' curve, 10KA as required with bus bar, neutral bar and necessary wire sets. As per specification. MCB, RCBO and DB should be as per tech spec. and of same make.
as per tech. spec.
accessories, as per IS:9537, reputed make with High mechanical stress (HMS) type including fixing accessories.
as per IS 9537 part II.
made good in all respect and satisfaction of Engineer Incharge.
Description:- Supply and installation of PVC trunking of size 35mm X 30mm. This PVC Trucking shall
which adheres to international standards in all process of manufacturing, thus enduring a product which meets the high level of Quality and Safety. The installation work shall be executed to the satisfaction of Site Engineer.
ventilation fan of 300 mm. sweep with louver shutters. Fan should be of reputed make and as per tech. spec.
29 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY 29 Description:- Laying, connecting, testing and commissioning of 4x50sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe as per spec including transportation (HDPE pipe will be supplied by Railway).
kuchha / pucca land and all type of soil as per site requirement and without protective layer of brick. Surface of trench shall be made good in all respect and satisfaction of site engineer.
6, PE 80 as per requirement.
under the road. The work involves laying of HDPE pipe along with transportation.
work involves laying of HDPE pipe with transportation.
road. The work involves laying of HDPE Pipe with transportation.
Description:- Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP
model no. GSJB 3525 or similar with 4 no. aluminium busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole / wall as per requirement. All the material should be of good quality.
I for passing incoming and outgoing cable from ground through it size 38 mm dia. Pipe should be of reputed make and as per tech. spec.
I for passing incoming and outgoing cable from ground through it size 100 mm dia. Pipe should be of reputed make and as per tech. spec.
Description:- Supply, installing, testing and commissioning earth electrode complete in all respect
50mm with all accessories like nut bolt, reducer nipple, wire meshed funnel and CC finished chamber covered by CI/RCC frame etc. Digging pit and refilling it with charcoal and salt in successive layers and connection with 25x3 mm GI strip and as per IS:3043 and testing of earth resistance as required.
Description:- Design, manufacturing, supply, testing, erection and commissioning of LT panel, medium voltage. (a) Incoming 1 x 400 Amps 4 pole MCCB with adj .overload and adj. short circuit trip
MCCB with adjustable overload and adjustible short circuit trip unit and 2 x 125 Amps. 4 pole MCCB with adjustable overload and fixed short circuit trip unit breaking cap. 36kA (Ics = 100% Icu) as per technical specification.
N + E) with 63A MCB for ON/OFF for welding with enclosure as per site requirement.
44 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY 44 Description:- Supply of material, fabrication, installation and commissioning of Rolling in Examination lighting MS box of suitable dimension comprising of sheet steel 1.6mm thick, 60 micron powder coating - grey shade, gland plates, neoprene EDPM/rubber gasket, padlock arrangement, zinc passivated earth bolt, canopy etc. All the material should be of good quality.
Description:- Supply and Fixing LED flood lights 30 W, outdoor type, suitable for rolling in examination hut, Aluminum die cast housing, Instant Start, operating voltage 90 V-300 V AC IP 65,
minimum 50,000 burning hours. THD should be less than 20. Luminaire shall be as per tender specs. Reputed make like Crompton / Philips / Wipro / Bajaj / Orient / Havells / Surya. Minimum warranty of 5 years.
30mA with Earth leakage, overload and short circuit protection as per relevant IS / IEC as per spec.
leakage, overload and short circuit protection as per spec.
IEC 61439-3, Suitable for flush mounting and surface mounting with door for IP 54, similar to Legrand or any reputed make.
tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required.
metallic object) by riveting / nut bolting/sweating and soldering etc. as required.
lightning conductor complete as required. (For horizontal run)
lightning conductor complete as required. (For vertical run)
RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest.
RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest.
cover and all fixing arrangements as per specification and as per site requirement.
made of MS sheet 1.6mm thick size 600x300x600mm with suitable MS stand copper bus bar of 200A capacity and 2x63A 4 Pole MCB as per spec.
Description:- Drilling of horizontal bore below Track/Road by trenchless technology for laying of
all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. below from ground level at railway track portion.
Description:- Transportation, installation, testing and commissioning of water cooler including water
foundation with concrete and cement for placement of water cooler at proper height for ease of drinking water as instructions of site supervisor of railway.
per site requirement and instructions of railway supervisor. Square
Foot 60 BIKANER DIVISION-ELECTRICAL/NORTH WESTERN RLY 60 Description:- SITC of Single sided signage board with symbol as per requirement & technical specification.
Description:- SITC of Battery Charging rectifier set complete with all accessories having earthing
Switches as outgoing. Input - 3 phase 415 Volts AC Output - 110 Volts to 150 Volts DC, 200 Amp. as per RDSO latest specification.
box two ways outdoor type as per RDSO Drg. No. SKE-3929 as per specifications.
Description:- Supplying, fixing, testing & commissioning of Automatic operation street light timing
suitable size of contactors, copper conductor etc. at specified locations as per specification attached and Similar to model no. 04764 of LEGRAND or similar of Siemens / ABB make.
capacity 20 HP suitable for bore 150mm, discharge Head 210 Mtrs, 360 LPM BEE approved reputed make like KSB / Duke / CRI / Sabar / CG.
Railway yard / below track / Road.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
UpdatedGCC.pdf
ATTACHMENT
ACS.pdf
ATTACHMENT
T-26TenderSpecs.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .