| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.5 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹79.8 L+₹3.7 L (4.92%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹82.0 L+₹5.9 L (7.74%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹82.3 L+₹6.2 L (8.11%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹84.1 L+₹8.0 L (10.5%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | somnath engineering corporation L3 | DARSHAN CONSTRUCTION Co. L4 | BRITE INDUSTRIES L1 | pk Enterprises L2 | RADHA ENTERPRISE L5 | sapana enterprises L7 | Shree Ayyappa Engineering L8 | cooltech engineering services L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | PART - I :
(a) B/R Works
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets, complete all as specified and directed by Engr-in-Charge. | 350 | Sqm | 51 ₹17,850 | 18 ₹6,300 | 45 ₹15,750 | 15 ₹5,250 Lowest | 25 ₹8,750 | 31 ₹10,850 | 18 ₹6,300 | 36 ₹12,600 |
| 2.00 | Supply and Fix PVC sheets, of 2mm thick laminated plain coloured, laid with approved rubber based adhesive in floors, complete all as specified and directed by Engr-in-Charge. | 195 | Sqm | 950 ₹1,85,250 | 775 ₹1,51,125 Lowest | 950 ₹1,85,250 | 850 ₹1,65,750 | 904 ₹1,76,280 | 1,061 ₹2,06,895 | 981 ₹1,91,295 | 947 ₹1,84,665 |
| 3.00 | Supply and Fix false ceiling with Armstrong XL 24mm grid system of grid size 600x600mm with 12 mm thick ceiling board of RH-90. including frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm dia GI (upto 1200 mm length) adjusting and maintain for proper level to roof slabs by means of ceiling cleats made out of GE flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm x 25 mm angles complete as per direction of Engr-in-charge, Manufacturer's specification & drawing. | 300 | Sqm | 1,010 ₹3,03,000 | 1,033 ₹3,09,900 | 1,350 ₹4,05,000 | 919 ₹2,75,700 Lowest | 1,022 ₹3,06,600 | 1,000 ₹3,00,000 | 1,044 ₹3,13,200 | 1,053 ₹3,15,900 |
| 4.00 | Supply and Fix in repair 8 to 10mm thick Armstrong ceiling board of RH -90 false ceiling consisting of 600mm x 600mm insert existing frame work without disturbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge. | 150 | Sqm | 500 ₹75,000 Lowest | 747 ₹1,12,050 | 790 ₹1,18,500 | 815 ₹1,22,250 | 678 ₹1,01,700 | 743 ₹1,11,450 | 757 ₹1,13,550 | 760 ₹1,14,000 |
| 5.00 | Supply and Fix for PVC False ceiling consisting of 600 mm x 600 mm, 8-10mm thick prelaminated self design including frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm dia GI (upto 1200 mm length) adjusting and maintain for proper level to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm X 25 mm angles complete as per direction of Engr-in-charge, Manufacturer's specification & drawing. | 50 | Sqm | 1,271 ₹63,550 | 1,255 ₹62,750 | 1,001 ₹50,050 Lowest | 1,237 ₹61,850 | 1,280 ₹64,000 | 1,266 ₹63,300 | 1,291 ₹64,550 | 1,300 ₹65,000 |
| 6.00 | Supply and Fix in repair 8 to 10mm thick PVC false ceiling consisting of 600mm x 600mm prelaminated self design insert existing frame work without disturbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge. | 40 | Sqm | 650 ₹26,000 | 710 ₹28,400 | 780 ₹31,200 | 645 ₹25,800 Lowest | 723 ₹28,920 | 717 ₹28,680 | 727 ₹29,080 | 731 ₹29,240 |
| 7.00 | Supply and Fix 4 mm thick plain asbestos cement board as in false ceiling fixed with timber or mild steel framed work grid and making to good existing frame without disturbing the other false ceiling complete all as directed by Engr-in-Charge.
(Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) | 40 | Sqm | 391 ₹15,640 | 383 ₹15,320 | 380 ₹15,200 Lowest | 400 ₹16,000 | 393 ₹15,720 | 387 ₹15,480 | 397 ₹15,880 | 403 ₹16,120 |
| 8.00 | Taking down ceiling boards (fibre, plub, insulation boards, blankets any thickness and refixing in ceiling, flat or sloping as per existing pattern with timber, mild steel or aluminium framed work grid and making to good existing frame without disturbing the other false ceiling complete all as directed by Engr-in-Charge.
(Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) | 250 | Sqm | 93 ₹23,250 | 87 ₹21,750 | 84 ₹21,000 | 40 ₹10,000 Lowest | 97 ₹24,250 | 91 ₹22,750 | 103 ₹25,750 | 107 ₹26,750 |
| 9.00 | Material and Labour for applying two coats of oil bound distemper over a coat of chalk whitening on asbestos cement board false ceiling , complete all as specified and directed by Engr-in-Charge.
(Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) | 40 | Sqm | 87 ₹3,480 | 77 ₹3,080 | 80 ₹3,200 | 65 ₹2,600 Lowest | 91 ₹3,640 | 83 ₹3,320 | 93 ₹3,720 | 97 ₹3,880 |
| 10.00 | Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debris directed for a distance max upto 500m, complete all as specified and directed by Engr-in-Charge. | 470 | Sqm | 99 ₹46,530 | 97 ₹45,590 | 94 ₹44,180 | 116 ₹54,520 | 60 ₹28,200 Lowest | 103 ₹48,410 | 115 ₹54,050 | 117 ₹54,990 |
Tender Value
₹82 L
EMD Value
₹1.5 L
Closing Date
16 Aug 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
COMPREHENSIVE REPAIR / MAINTENANCE OF CHILLERS, AHU UNIT, COOLING TOWER, COMPRESSOR, CONDENSOR, EXPANSION VALVES OF AC PLANT ALONGWITH ALLIED B/R WKS OF ZONE VIII LOCATIONS OF TUNIR AREA AT NAVAL STATION KARANJA
2025_MES_721142_1
84476-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
420 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.5 L
30 Sept 2025
18 Jul 2025
18 Aug 2025
18 Jul 2025
16 Aug 2025
8 Aug 2025
Amount
PART - I : (a) B/R Works Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets, complete all as specified and directed by Engr-in-Charge.
Supply and Fix PVC sheets, of 2mm thick laminated plain coloured, laid with approved rubber based adhesive in floors, complete all as specified and directed by Engr-in-Charge.
Supply and Fix false ceiling with Armstrong XL 24mm grid system of grid size 600x600mm with 12 mm thick ceiling board of RH-90. including frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm dia GI (upto 1200 mm length) adjusting and maintain for proper level to roof slabs by means of ceiling cleats made out of GE flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm x 25 mm angles complete as per direction of Engr-in-charge, Manufacturer's specification & drawing.
Supply and Fix in repair 8 to 10mm thick Armstrong ceiling board of RH -90 false ceiling consisting of 600mm x 600mm insert existing frame work without disturbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge.
Supply and Fix for PVC False ceiling consisting of 600 mm x 600 mm, 8-10mm thick prelaminated self design including frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm dia GI (upto 1200 mm length) adjusting and maintain for proper level to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm X 25 mm angles complete as per direction of Engr-in-charge, Manufacturer's specification & drawing.
Supply and Fix in repair 8 to 10mm thick PVC false ceiling consisting of 600mm x 600mm prelaminated self design insert existing frame work without disturbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge.
Supply and Fix 4 mm thick plain asbestos cement board as in false ceiling fixed with timber or mild steel framed work grid and making to good existing frame without disturbing the other false ceiling complete all as directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Taking down ceiling boards (fibre, plub, insulation boards, blankets any thickness and refixing in ceiling, flat or sloping as per existing pattern with timber, mild steel or aluminium framed work grid and making to good existing frame without disturbing the other false ceiling complete all as directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Material and Labour for applying two coats of oil bound distemper over a coat of chalk whitening on asbestos cement board false ceiling , complete all as specified and directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debris directed for a distance max upto 500m, complete all as specified and directed by Engr-in-Charge.
Material and Labour for ready mix plaster rendering 10 mm thick in CM 1:4 on fair faces of brick/concrete surfaces , finished even and smooth without smoothing extra cement, complete all as specified and directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) (WPC shall be paid and measured separately)
Material and Labour for ready mix plaster rendering 15 mm thick of brick work or concrete surfaces in CM 1:4 (Water proofing compound paid separately) finished even and fair surfaces without using extra cement, complete all as specified and directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.) (WPC shall be paid and measured separately)
Material and Labour using ready mix plaster rendering 5 mm thick CM 1:3 on ceiling or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Material and Labour three coats of white wash on newly plastered surfaces of ceilings including preparation of surface, complete all as specified and directed by Engr-in-Charge.
Material and Labour for newly plastered surface and prepare the smooth surface with sand paper and applying two coats of royal acrylic distemper on walls or ceiling complete all as specified and as directed by Engineer-in-Charge
Material and Labour applying 2mm thick exterior grade wall care putty on wall all as specified and directed by Engineer-in-Charge
Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plaint or camouflage pattern over one coat of primer , complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound mix cement concrete/ cement plaster as per manufacture instruction, complete all as specified and directed by Engr-in-Charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc, complete all as specified and directed by Engr-in-Charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, complete and also including powder coated aluminium fittings such as stainless steel hinges, tower bolts, hooks & eyes, peg stays and handles, concealed star lock for aluminium window, Mortice lock vertical type size 100mm 04 lever for door, rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors including connected items, with and making good to the disturbed portion with its original specifications including taking down existing members/frame any position, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for rubber beading suitable for fixing 4mm/ 5mm thick glass in aluminium window / doors etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 4mm thick sheet glass ordinary quality black glass colour, white or multicolour like black etc as directed by Engr-in-Charge and glazing with oil putty in square exc 0.5 Sqm in each pane with glazing pins complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix 4 mm thick sheet glass , figured glass, pinhead type , glazing with oil putty area not exceeding 0.50 Square Metre each pane, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple, complete all as specified and directed by Engr-in-Charge.
Supply and Fix for aluminium body hydraulically door closer regulated, designation No.3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair double action floor spring hydraulically regulated made up to min 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty & fixed, complete all as specified and as directed by Engineer-in-Charge.
Taking down shutter of any description not exc 1Sqm each complete all as specified and directed by Engr-in-Charge.
Taking down shutter of any description exc 1Sqm and not exc 2 Sqm each complete all as specified and directed by Engr-in-Charge.
Material and Labour second class Hardwood 35 mm thickness, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters, complete all as specified and directed by Engr-in-Charge.
Supply and Fix factory made 30 mm thick solid core Flush door shutter with block board with BWP plywood on both side all as specified directed by Engr in Charge.
Material and Labour second class hardwood 30 mm thickness plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats all as specified and directed by Engr-in-Charge
Supply and Fix Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC Sheet used 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm used instead of exposed portion of PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed by Engr-in-Charge.
Material and Labour 30mm thick factory made pre laminated flush door shutters, 2 mm finishes in hi-gloss and confirming to IS -2046 and solid core construction, with particle board core and plywood face panels, suitable for exterior & interior grade door, commercial type on both sides all as specified and directed by Engr-in-Charge.
Supply and Fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Material and Labour for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary SS screws shall be paid separately)
Supply and Fix in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparation of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of pink wood primer all as specified and directed by Engineer-in-Charge.
Supply and Fix 150 mm stainless steel barrel tower bolts of extruded section and fixed to shutter complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix two legged aluminium floor door stopper with rubber shoe 140mm long complete all as specified and directed.
Supply and Fix 100mm long medium grade stain less steel butt hinges bright polished fix to steel chowkhat with SS screw all as specified directed by Engr in Charge.
Supply and Fix 300mm long, 16mm dia stain less steel bright polished door sliding bolt hasp and staple type with fixing of clips 3 Nos with fixing with nut & bolt all as specified directed by Engr in Charge.
Supply and Fix mild steel pressed handles, oval type, stove enamelled black 150mm long fancy type complete all as specified and as directed by Engineer-in-Charge.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar, complete all as specified and directed by Engr-in-Charge.
Supply and Fix green marble 18 to 20 mm thick machine cut, jointing and pointing with white cement slurry including 15mm thick screed bed or bedding layer of mortar in CM 1:6 , complete all as specified and directed by Engr-in-Charge.
Material and Labour for 20-25 mm thick machine cut Kota stone slab flooring over cement screed bed 15mm thick in CM 1:6 and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete all as directed by Engr-in-Charge.
Material and Labour for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform, vertical surfaces and any position in cement mortar 15 mm thick 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including chamfering and rounding of edges where required all as specified and directed by Engr-in-Charge.
Material and Labour for 20-22 mm thick machine cut Kota stone in riser of steps, skirting, dado, and pillar laid over cement mortar 10 mm thick 1:4 and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete all as directed by Engr-in-Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises and removal to any distance, complete all as specified and directed by Engr-in-Charge.
Material and Labour for glazed ceramic coloured designer concept tiles matching with existing tile 350x250x7 or 450x350x7mm size as in walls set and jointed in neat cement slurry over 10mm thick recuing in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc all as specified and as directed by Engr-in-Charge.
Material and Labour for non skid ceramic coloured tile 7 to 8mm thick (square/rectangular area of each tiles exceeding 0.11 Square but not exceeding 0.18 Sqm in floor over 15mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the tile , complete all as specified and directed by Engr-in-Charge.
Material and Labour for Vitrified ceramic coloured double charge dark shade tiles 7-8 mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 10 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed by Engineer-in-Charge
PART - I : (b) E/M Works Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/PVC conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by Eng-in-charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including 3mm hylam /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for One light point or one fan point controlled by one switch. Note : Wiring to be done as per approved colour code.
-Ditto - all as per item No 56.00 here-in-before but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
-Ditto - all as per item No 56.00 here-in-before but one 5 amp socket point on same board
-Ditto - all as per item No 56.00 here-in-before but one 5 amp multi socket, independent
-Ditto - all as per item No 56.00 here-in-before but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
-Ditto - all as per item No 56.00 here-in-before but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano type flush button type single pole one way 5 Amps 240V front operated, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Switch socket combination 2 in 1 3 pin, 5 A and 15Amp flush type universal, complete all as specified and directed by Engr-in-Charge.
Supply and Fix socket 3 pin 5 A flush type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell buzzer 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell push 240V 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals, complete all as specified and directed by Engr-in-Charge.
Supply and Fix repair/replacement switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed Engineer-in-Charge.
Supply and Fix in repair/replacement Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size, complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair/replacement Lamp holder/angle holder insulated body with black/white plate for batten fittings, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/ suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down all as specified and directed by Engr-in-Charge.
Material and Labour for cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash, complete all as specified and directed by Engr-in-Charge.
Supply and fixing repair/replacement LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 W, IP 66 protection LED, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement LED batten with 20/22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 4 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 8 Way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series), complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement SPN 32 AMP ,240 V 10 KA (C-Series) , complete all as specified and directed by Engr-in-Charge.
Supply and fix LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engr-in-charge.
Supply and Fix in repair/replacement LED tube rod 20/22 watt, 220V,AC, 50Hz change with existing any tube rod including flexible wire and connected accessories , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement Batten MS suitable for 18/22/24W LED rod 220V,AC, 50Hz with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten 10W, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by Engr-in-charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement PCRD plug of capacity 15 amp , AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size approx 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement emergency bulb LED 10W, 230V, 50Hz, with 2/4 hour backup, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking out and refixing of tube light, mirror light etc after cleaning and any type rectifying defect, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Material and Labour for checking ceiling fan of size 1200/1400mm and change defective part quarter pin/ nut bolt , capacitor ,rewinding, bearing and minor items etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair GI strip 32mm x 6 mm saddle in wall for loop earthing and ground grid , complete all as specified and directed by Engr-in-Charge.
Supply and fix fan rod repair/replacement of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix repair/replacement flexible wire 1 sqmm x 2 core including taking out, complete all as specified and directed by Engr-in-Charge.
Supply & fixing, jointing, connecting & testing in saddle on wall 10 sqmm x 2 core, XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts/ of the following sizes including taking out cable cover & cable, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs/replacement air termination single pointed aluminium rod 12 mm dia and 1000 mm long with necessary fixing arrangement on blocks on roof, complete all as specified and directed by Engr-in-Charge.
Supply and Fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall as in repairs, complete all as specified and directed by Engr-in-Charge. Note :- Porcelain insulator will be measured & paid for separately.
Supply and Fix repair/replacement vitreous china porcelain insulator with busbar support white type, complete all as specified and directed by Engr-in-Charge.
Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrangement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 40 mm dia GI pipe medium grade for post not exceeding 3 metres in length truly vertical position embedded in PCC including not exc and earth work as in repairs, complete all as specified and directed by Engr-in-Charge. Note : PCC of pole embedded will be measured and paid separately under relevant items of Sch.
Material and Labour for PCC (1:2: 4) type B0, using (12.5 mm graded stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grounting of porcelain insulator, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC (1:2:4) type B1, using (20 mm graded stone aggregate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance not exc 50 metre and deposing where directed, complete all as specified and directed by Engr-in-Charge.
Removing & refixing of air termination single pointed aluminium rod 12 mm dia and 300 mm long by tightening with necessary fixing arrangement fixed on existing/new PCC blocks on roof and making good complete all as specified and directed, complete all as specified and directed by Engr-in-Charge.
Material and Labour repair/replacement Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including PVC conduit 20 mm dia with accessories like bend, junction box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuity conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement aluminium strip of size 25 x 3.15 mm fixed with suitable saddle, screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Fabrication of Panel /DB COVER OF CRCA sheet sheet 2mm thick duly powder coated with seimens grey shade RAL 7032, totally enclosed, dust and vermin proof with including welding, machining work and connected items , taking down old cover, all as specified and directed by Engr-in-charge.
Re-fixing in repair only aluminium strip of size 20/25 mm x 3.15 mm fixed to porcelain insulator fixed with suitable saddle, screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair/replacement two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB, complete all as specified and directed by Engr-in-Charge.
PART - I : (c) AC Works Supply and fix in repairs cooling tower fan Assembly with fan speed not exceeding 60m/s, outlet air velocity not less than 610 m/min with noise level not exceeding 75 dBA made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades alongwith galvanised steel guard protection to protect fan and out side area suitable for upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply and fix in replacement of eliminator of cooling tower upto 100 TR, complete all as specified and directed by Engr-in-Charge.
Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, cleaning of base tray & grills, pot stainer, main shaft etc and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill & top cover including testing commissioning after reassembling complete including painting all as directed by Engr-in-charge
(a) cooling tower of capacity upto 35 TR
(b) cooling tower of capacity 66 TR to 250 TR
Supply and fix in repairs Sprinkler Assembly complete with Header Nozzles made out of Galvanised iron suitable to fix in cooling towers of upto 60 TR capacity AC plants, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Charging of refrigerant gas R- 407C/ R134/R22 in sealed cylinder after making system leak proof, complete all as specified and directed by Engr-in-Charge. (Note:-Refrigerant shall be issued to contractor for each AC plant from AGE E/M -II store yard. Transportation as well as loading/unloading of cylinder from AGE E/M store yard to AC plant will be the responsibility of the contractor)
Supply and fixing of filter drier for chiller as per existing make and model , complete all as specified and directed by Engr-in-Charge.
Supply and Fix of supply / return / exhaust air grills /of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core, complete all as specified and directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-VIII AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush, air blower and water spraying pump with gun and mixing the chemical sittable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity upto 10000 CFM as directed by Engr-in-Charge.
Complete Servicing of AHUs installed in Zone-VIII AC plants, removing of air filters and refixing after cleaning with air blower and water with suitable cleaning agent , cleaning of cooling coil with wire brush, air blower and water spraying pump with gun and mixing the chemical sittable for removing of scales on aluminium fins and straighten the fins of cooling coil by using suitable brush for capacity 10000 CFM to 20000CFM as directed by Engr-in-Charge.
Material and Labour for repairs to condenser of AC plant by blocking the damaged/corroded tubes with the following instructions :- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged/leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser :-
(a) up to 35 TR Capacity
(b) 35 TR and above capacity
Supply and fix regenerable coarse type, dust proof AHU air filter for following sizes :-
(a) AHU air filter of size 60cm x 60 cm x 5 cm
(b) AHU air filter of size 60cm x 50 cm x 5 cm
(c) AHU air filter of size 60cm x 40 cm x 5 cm
(d) AHU air filter of size 60cm x 30 cm x 5 cm
Dismantling and removing old unserviceable compressor sealed unit of Scroll Type Compressor carefully and supply, installation, testing new sealed Compressor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss or equivalent complete with all standard accessories as per existing model installed at AC plant, complete all as specified and directed by Engr-in-Charge. Notes :- (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour for fixing and testing of leakage alongwith initial charging of suitable refrigerant and T&P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary electrical check i.e. checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling of unserviceable compressor the refrigerant to be taken in empty cylinder as directed by Engr-in Charge.
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 7.5 to 10HP, replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately. (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts , washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 135.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Ball bearing suitable for 7.5 HP pump set
Ball bearing suitable for 10 HP pump set
Bronze impellar suitable for 7.5 HP pump set.
Bronze impellar suitable for 10 HP pump set.
Bronze bush suitable for 7.5 HP pump set
Bronze bush suitable for 10 HP pump set
Bronze shaft suitable for 7.5 HP pump set
Bronze shaft suitable for 10 HP pump set
Dismantling and taking down defective parts of chiller/condenser pump set of capacity 3 to 5 HP, replacement of defective parts like-bearing, bushes, impeller and shaft including lathe work and reassembling complete set including connecting and testing in presence of MES rep with entire satisfaction of Engr-in-Charge. Notes:- (i) bearing, bushes and impeller and shaft shall be measured and paid separately. (ii) Quoted rates are also deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts, washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items. (iv) While taking out pump for repairs , the contractor will make arrangement plugging suction and discharge line with dead flanges, so that pumping of installation is not disturbed and there is no leakage of water.
Supply only in replacement the following spare parts for servicing and repairs of pump set under item No 137.00 here in before, complete all as specified and directed by Engr-in-Charge.
Ball bearing suitable for 3 HP pump set
Ball bearing suitable for 5 HP pump set
Bronze impellar suitable for 3 HP pump set.
Bronze impellar suitable for 5 HP pump set.
Bronze bush suitable for 3 HP pump set
Bronze bush suitable for 5 HP pump set
Bronze shaft suitable for 3 HP pump set
Bronze shaft suitable for 5 HP pump set
Material and Labour for painting of motor & pump for removing the existing deteriorated paint by scrapping the complete body along with complete foundation of Pump and Motor and filling the cavities with filter spray painting with Anti corrosive paint, two coats over a coat of red oxide zinc chrome and marking of SM/MES No. with black/white paint, complete all as specified and directed by Engr-in-Charge for following:-
(a) Capacity 7.5 HP and above
(b) Capacity below 7.5 HP
Material and Labour for rewinding of induction motor 900RPM, 3 phase, 50 Hz, 415 volt of compressor motor and AHU Blower , chiller , condenser motor comprising of the following activities for induction motor of following capacities complete all as specified and directed as per manufacturer's instructions. :- Notes :- (i) Any adjustment in the pump set if required. The same shall also be carried out by the contractor without any extra payment. (ii) Any damage to the pump set occurs due to improper installation of motor, contractor shall be liable for repair.
(a) Capacity 7.5 HP.
(b) Capacity 5 HP.
(c) Capacity upto 1 to 3 HP.
Dismantling electrically and mechanically electric motor any size, dismantling part, taking out unserviceable bearing capacity upto 15 HP including supply and replacement of new bearing, reassembling, reinstallation and testing complete all as specified and directed by Engr-in- Charge.
Dismantling electrically and mechanically electric motor of any size of AHU, taking out unserviceable Parts like-shaft, Impeller, bushes, fan blade, coupling and fan belt, replacement with new one, reassembling, reinstallation and testing the following size all as directed by Engr-in- Charge.
Supply only in replacement the following spare parts for servicing and repairs of AHU unit under item No 142.00 here in before, complete all as specified and directed by Engr-in-Charge :-
Bronze shaft suitable upto 60 TR AHU Unit
Fan belt suitable as per existing
Supply and Fix gland packing in 10/12.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix gland packing in 5/7.5 HP pump set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Water seal for upto 5 HP, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 2.5 to 4.5 Amp with single phasing protection all as specified and directed.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 4.5 to 7.5 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp with single phasing protection, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp with single phasing protection all as specified and directed by Engr-in-Charge.
Supply and fix in replacement electronic timer 800SQA, working voltage 240V 50 Hz , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement Air break contactor Model No 3TS3500-0A with Auxiliary 3TX400--2A 1 NC 415 V, 50 Hz, AC , complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB SP 6 to 32 amp rating 240V, 10KA 'C' curve , complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB TP 40 to 63 AMP 415V 10KA 'C' curve , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 400 Amps with breaking capacity 36 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge.(Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 22 or 25 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type MNX 32 , 1NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp of equivalent contactor of other makes as per site requirement in bluestar and voltas AC plants, complete all as specified and directed by Engr-in-Charge. (Make should be as per existing item)
Supply and fix in replacement power contactor 3 pole, type 1 NO/NC (Normal open/Normal Close) 65 Amps with standard coil voltage 415 volts, Chint's NC-1 6511 contactor of bluestar and voltas AC plants compressor unit of make M/s Chint's including taking down old unserviceable contactor all as specified and directed by Engr-in-charge. (Make should be as per existing item)
Supply, assembly and erection in repair of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joint etc complete of size 24 gauge, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50 mm all as specified and including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 metre.
Material and Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 40 mm all as specified and including the following :- (a) Material and Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and Labour for applying rubber based adhesive CPRX compound. (c) Material and Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 40 mm wide, to make the insulation leak proof. (d) Material and Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 40 mm at maximum intervals of 1.2 metre.
Supply and fix in replacement of thermostatic expansion valve of suitable capacity MVE size suitable for scroll type chiller units for keep a constant superheat or refrigerant level situation in refrigeration system based on evaporator outlet temperature and pressure. Brazing of the expansion valve is in the scope of the contractor in this item, all as specified and directed by Engr-in-Charge.
Material and Labour for descaling of complete condenser units of AC plant up to 60 TR Quarterly for central/ package type AC plants of following capacities by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. all as specified and directed to complete satisfaction of Engineer-in-charge
Supply and Fix in repairs of Motor and Voltage protective device 'M2VPD EC 5-30A' as per existing make and type complete all as specified and directed by Engr-in-Charge.
Supply and fix Microprocessor Scroll Controller for compressor of 12.5-40 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed. The Microprocesor should be as per the existing one and installed by the company authorised person duly callibrated and necessary wiring work also included in the quoted rate to the satisfication of Engr-in-charge.
Supply and fix Microprocessor Scroll Controller for compressor of 41-80 TR Capacity including removing unserviceable of Microprocessor complete all as specified and directed. The Microprocesor should be as per the existing one and installed by the company authorised person duly callibrated and necessary wiring work also included in the quoted rate to the satisfication of Engr-in-charge.
Supply and fix Micro controller system of Scroll compressor of 12.5-40 TR Capacity including removing unserviceable of Micro controller system complete all as specified and directed. The Micro controller system should be as per the existing one and installed by the company authorised person duly callibrated and necessary wiring work also included in the quoted rate to the satisfication of Engr-in-charge.
Supply and fix in replacement of Single phase preventer type SPP VSP3 3 phase, 415 Volts, 50 Hz AC, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of CVT for chiller controller power supply 3 phase, 415 Volts, 50 Hz AC, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 80mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 100mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MS ERW tubing medium grade 65 mm dia for condenser water circulation pipes, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Nitrogen leak test of entire system of the AC plant of Cap upto 150 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage permanently complete all as specified & directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 65 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line , complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 80 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of butter fly valve of 100 mm dia, cast iron body, integrally molded close and body construction with hand lever, operated and rating of PN 10 with thermal insulation as per requirement of condenser and chilled water line, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 15 mm dia with iron wheel head screwed both ends for iron pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of gun metal gate or globe valve of 25 mm dia with iron wheel head screwed both ends for iron pipes, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 15 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of 25 mm dia ball brass valve , high pressure, with polythene float and fly nuts complete, screw for iron pipe or brass ferrule and mixed, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs of Chilled water sensor as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs of pressure transducer sensor for LP and HP of the compressor unit as per existing make and type, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of flow switch as per existing make and model, complete all as specified and directed by Engr-in-Charge.
Material and Labour in repairs Strip heater finned 2 inch wide aluminised steel fins of 415 volt 1.5 to 3 KW capacity to match with the existing, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range -30-150, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pressure gauge of range 0-150 , complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs in repair on-off push button pendants with elements red/green/orange, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement V Belt of Make : Nirlon, Fenner, Ecodrive or equivalent, complete all as specified and directed by Engr-in-Charge of following sizes :-
(a) V Belt A-28
(b) V Belt A-24
(c) V Belt A-30
(d) V Belt B-62
(e) V Belt B-98
(e) V Belt B-100
Dismantling/Taking down old unserviceable FRP body structure of cooling tower carefully and cleaning the sump with chemical and supply and fixing of new FRP sheets as per size existing at site including all fixing material such as m seal other water resistance adhesive and making the cooling tower structure leak proof, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable insulation over the chiller pipe line, cleaning water pipe surface with steel brush removing dirt/dust, Material and labour for chilled pipe line insulation by applying a coat of zinc chromate primer & applying two coats of cold setting adhesive compound (CRPX) on pipes for sticking the insulation bonded mineral wool of density 144 Kg/cum, 50mm thickness tightly pressed on the pipe upto 250mm dia seal all the joint with adhesive compound warp the insulation surface by using one layer of polythene sheet 50mm wide PVC tape covering the entire surface with chicken mesh , of density 144 Kg/Cum and cover 26 gauge aluminium GI cladding of approved colour & cover with Glasswool complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs protection caps made out of GI Sheet of thickness 1.6 mm with three GI strip supports of size 25x3mm for fixing with the Cooling Tower including GI nuts & bolts for fixing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for earthing complete with copper earth plate electrode of 60 cm x 60 cm x 3.15 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm x 550 mm (outer) and 300 mm x 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete as specified and directed by the Engr-in-Charge. Notes: (i) The cost of earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in respect of above item. (ii) The earth resistance value should not be more than 2 Ohm. (iii) Earth test report shall be submitted by contractor. If the earth resistance value is more than 2 Ohm new earthing will be done by contractor as replacement and no payment shall be mate for it. (iv) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 x 3 mm copper strip complete as specified and directed by the Engr-in-Charge.
Supply and fixing of canvas housing suitable for existing connection AHU damper to Supply air Duct, complete all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repairs of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal as required, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of wall mounting /hanging type LED digital type temperature /relative humidity indicator with 2" large size display and minimum size (445x130x115mm) with following specifications complete all as specified and as directed by Engr-in-charge. Display : 2" Red LED x 2 Display, Accuracy : + 0.5%, Resolution : 0.1 deg C, 0.1 % RH, Input : 4-20mA, Enclousure : Powder coated metal case. Operating Voltage : 230V AC
Material and labour for laying, jointing, connecting and testing in repairs sensor cable 3 core 2.5 sqmm PVC insulated and sheathed with bare annealed copper conductor as per IS 694:1990 for connecting RH+T sensor to RH+T indicators complete all as specified and as directed by Engr-in-charge.
Material and labour for laying, jointing, connecting and testing in repairs indicator cable 2 core 1.5 sqmm PVC insulated and sheathed with bare annealed copper conductor complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of Thermal Insulation of Ducts with Nitrile Rubber, thickness of 25 mm with aluminium cladding, complete all as specified and directed by Engr-in-Charge. Density of Material shall be between 40 to 60 Kg/m3. Note :- Material shall have flammability class V-0 as per UL 94 and shall be FM Approved.
Supply only Rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs steel water tubing galvanised iron 25 mm dia medium grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs steel water tubing galvanised iron 40mm dia light grade with all fittings ISI marked including taking down old unserviceable GI pipe all as specified and directed by Engr-in-Charge. (item used for earthing only)
Supply and Fix in replacement of Non return single plate check valve designed for return flow prevention in pipeline installation of size 80 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of Non return single plate check valve designed for return flow prevention in pipeline installation of size 63 mm dia, cast iron body for water delivery line complete all as specified and directed by Engr-in-Charge.
Material and Labour for replacement of unserviceable pot strainer 80/100mm including replacement of unserviceable rusted nut bolts, washers, & gasket complete all as specified and directed by Engr-in-Charge.
Material and Labour for spray painting to Central AC Plant complete comprising of compressors, motors, condensor, cooling tower and cooling tower pumps, pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code including and marking arrow, SM/ MES Nos, colour for upto 60 TR ACs plant as directed by the Engr-in- charge.
Material and Labour for spray painting to Central AC Plant complete comprising of compressors, motors, condensor, cooling tower and cooling tower pumps, pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code including and marking arrow, SM/ MES Nos, colour for upto 120 TR ACs plant as directed by the Engr-in- charge.
Supply and Fix of Drift eliminator of cooling tower having capacity of 20TR to 85TR as per existing at site complete all as specified and directed.
Supply and Fix of Drift eliminator of cooling tower having capacity of 85TR and above as per existing at site complete all as specified and directed.
MAKE UP TANK : Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 5000 litres capacity mounted on suitable stage PCC 1:2:4 complete all as specified and as directed by Engr-in-charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included quoted rate.
MAKE UP TANK : Supply and fix for PVC two mounting layered, closed lid cylindrical shapes ISI marked water tank of 10000 litres capacity mounted on suitable stage PCC 1:2:4 complete all as specified and as directed by Engr-in-charge. Note :- In case some parts required extensive repair and replacement , the same shall be done by contractor. Rates deemed to be included quoted rate.
PART - II : (a) Manning & Operation Out sourcing of services for Manning and operation of central AC plants by one skilled ref mech operator in each shift of 08 hrs i.e Two (02) in a day for shifts i.e. 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, including Sunday & Holiday. The documentation of plant to be done by Ref Mech including maintaining Log Book. Routine maintenance including upkeep and cleanliness of other equipment like pump/motors, Cooling tower, AHU and surrounding area will be done by Ref Mech. The following AC plant equipments, accessories and control panel will be maintained as specified and as directed by Engr-in-charge. (a) Chilled water type central AC plant make Voltas of capacity 24 TR (01 working + 01 stand by) installed at MLSC MRF P-15 for maintaining Temp 23°C + 2°C and humidity 65 + 5% (b) Chilled water type central AC plant make Blue star of capacity 52 TR (02 working + 01 stand by) installed at Akbar 1 A for maintaining Temp 23°C + 2°C and humidity 60 + 5%
General notes for Item No 221 (a) Rate quoted by tenderer for the above items shall be deemed to be included for the expenditure of keeping general cleanliness of the area of the installations complete including cutting of grass shrubs & vegetations around the installations. (b) Protective clothing as per IS and safety instructions & tools required as applicable shall be provided by the contractor and shall be continuously in use of the operator on duty. No extra payment will be made to contractor for the same. (c) Printed log sheet shall be provided and maintained by the contractor properly as per the format approved by Eng-in-Charge duly signed by all concerned and no extra cost shall be admissible for this account. Log book shall be deposited with concerned JE every months and no payment will be made in absence of the same. (d) ITI qualified in Air Conditioning & Refrigeration or having minimum 5 years experience in operation and maintenance of Air Conditioning & Refrigeration plant shall be deployed by the contractor. Contractor shall arrange his man power in such a way that each employee should not be assigned more than one shift of 8 hours in a single day and weekly one day off is given to each employee for which separate manpower arrangement to be done by the contractor without any extra cost to the dept. (e) Any breakdown of AC Plant shall be reported immediately to JE E/M / Engr-in- Charge. (f) Life insurance of employed person shall be carried out by the contractor at his own cost from any insurance company approved by IRDA.
(g) Contractor will provide the uniform as recommended by Engr -in-Charge. The safety of equipment necessary T & P shall be maintained at all the installations. The contractor shall be fully responsible for safety of staff employed. Department will not be held responsible for any eventuality occurred to staff employed. The contractor will be responsible / liable to pay all type of compensation etc to employed staff in accordance with prevailing labour laws in country/ staff. (h) The tradesmen shall be well conversant with preventive measures (First Aid) in case of electrical accidents and fire fighting systems. (j) Carrying out operation of equipments, as a part of day to day operation and in accordance with relevant PM checklists and as per schedules that will be prepared upon activation of contract. The salient features in these checklists are as follows :- (i) Starting and stopping of the equipment as per requirement of the user. (ii) Checking the water level in the cooling tower (applicable for water cooled units) (iii) Recording the equipment operational parameter including pump pressure and motor amps in the log sheet. (iv) Checking the central AC or Refrigeration system and equipment such as compressors, motors, pumps, cooling towers and their electrical controls on the respective equipment. (v) Checking the refrigeration system for any leaks. (vi) Checking the electrical and refrigeration control system for operation and adjustments of set values as necessary. (k) Penalty of absence of any Ref Mech shall be Rs 2500/- per shift per day. (l) Tmp measurer shall be provided by contractor in respective installation in proper working condition. Rates quoted deemed to include the same.
Notes:- The quoted rate for above plants described at item No 221 here-in-before shall be deemed to be included the following:- (i) The operator shall be ITI holder with sufficient experience (not less than 05 years). The operator should be capable to rectify both mechanical as well as electrical defects for smooth functioning of AC plants. It is responsibility of contractor to provide a reliever to the operator. So that the operator is available all time. (ii) Man power list with aadhar linked bank account number, qualification certificate will be submitted prior to commencement of work for necessary sanction from GE. (iii) The contractor/ service providing agency shall be wholly and exclusively responsible for payment of wages of persons engaged by it in compliance with all the statutory obligations under all related legislations as applicable to it from time to time including Minimum Wages Act, ESI Act, EPF Act and the Department MES shall not incur any liability for any expenditure whatsoever on the persons employed by the contractor/ agency on account of any obligation. The contractor/ service providing agency will be required to provide particulars of group Insurance of employees engaged by him to the GE before processing of RAR payment. (iv) The contractor/ service providing agency will be required to provide two set of uniform to all operators with name and firm tag. (v) To carry out routine periodical checkups as directed by GE & Engr-in-Charge. (vi) Maintaining all the accessories such as electric panel, Interlocking wiring cables, pumps etc and all assemblies such as chillers etc and sub assemblies such as AHU, tower etc functional in any situation round the clock for the period including holidays etc. (vii) Maintaining the surrounding area of central AC plant building, cooling tower, etc neat & clean at all time. No wild vegetation to be seen with in the surrounding of building upto 5 metres all around (viii) Tools and plants such as spanners, wrench, screw driver, pliers, puller (Mechanically hydraulic) and alike items required for operation, sufficient running of the parts shall be arranged & are kept permanently with the staff (contractor's staff). However any major items which are required, as part of the installation shall arranged by the department.
pk Enterprises (BID ID -3393704)
somnath engineering corporation (BID ID -3392220)
DARSHAN CONSTRUCTION Co. (BID ID -3392577)
RADHA ENTERPRISE (BID ID -3394519)
cooltech engineering services (BID ID -3396337)
sapana enterprises (BID ID -3395907)
Shree Ayyappa Engineering (BID ID -3396312)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .