Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 CrAccepted-AOC | ₹16.9 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹18.5 CrRejected-Finance NA | ₹18.5 Cr | L2 | Rejected-Finance ok |
| 3 | L3₹18.8 CrRejected-Finance | ₹18.8 Cr | L3 | Rejected-Finance ok |
| 4 | L4₹19.2 CrRejected-Finance | ₹19.2 Cr | L4 | Rejected-Finance ok |
| 5 | Not Admitted-Fee/PreQual/Technical NO 152 E V R NAGAR SRIRANGAM TIRUCHIRAPPALLI 5 | TIRUCHIRAPPALLI | TAMIL NADU | 620001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹38.6 L
Closing Date
29 Dec 2025, 10:00 amClosed
Er. PRADEEP KUMAR
EXECUTIVE ENGINEER, CONSTRUCTION DIVISION, PWD B and R, PATHANKOT
UPGRADATION OF PATHANKOT SHAHPURKANDI ROAD (SECTION SUJANPUR L/R TO SHAHPURKANDI KM 13.48 (SECTION 5.83 TO 13.48 KM) and BANI LODHI KOTLI MUGLAN UPTO J and K BOUNDARY IN DISTT. PATHANKOT INCLUDING MAINTENANCE OF 5 YEARS (Under the Special Assistance
2025_CEPW_154028_1
Bid No. 46 Dated 19-11-2025 SHAHPURKANDI ROAD AND BANI LODHI ROAD(Group No. 1)
Open Tender
Civil Works - Roads
365 days
PATHANKOT
Please refer Tender documents.
7 documents required · 7 mandatory
₹50,000
₹38.6 L
DAC PATHANKOT
4 Feb 2026
28 Nov 2025
29 Dec 2025
28 Nov 2025
29 Dec 2025
28 Nov 2025
8 Dec 2025
Dismantling of flexible pavements thickness above 50mm by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of se rviceable material to be used or auctioned, up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness as per technical clause 201 of MORT&H specifications In area of Light Jungle (By Mechanical Means) Csr 24.2c
Excavation in Soil (by mechanical means) (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cumbucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades andcross sections, including all lift and combined lead up to 60 mtr. CSR 24.6(c)
Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications.
Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications
Relaying of GSB
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications
Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications
Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications
Providing and laying patch work with bituminous macadam 50mm to 75mm thick using crushed stone aggregates of specified grading premixed with bituminous binder VG-30 @ 3.4% in Continuous type hot mix plant, carriage of mixed material to site of work, laid after trimming the pot hole, removal of failed material, laying by suitable means and rolling with a smooth wheeled roller to match the adjoining surface complete as per technical clause 504 of MORT&H specifications
Scarifying the existing Bituminous road surface to a depth of 50mm and disposal of scarified material with in all lifts and lead upto 1000 meters
Providing and laying dense graded bituminous macadam 50mm to 75mm thick with batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications
Providing and laying bituminous concrete 30mm to 45mm thick with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications
Construction of Shoulder with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage of site of work, spreading, grading to required slope and compacting to meet requirement as per clause 3003 of MORT&H Specifications
Compaction Extra for laying earth/fly ash as per specifications in 20 cm. Layers and dressing but excluding cost of rolling. Extra for watering the earth/fly ash laid in 20 cm layers as per specifications for compaction. Extra for rolling to specifications.
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
Supplying and fixing of single mould twin shank reflective road studs made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens or Glass Beeds capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The supplier shall provide a 2 years warranty for satisfactory field performance as per clause 804.7.3 of MORT&H 5th revision specifications.
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
Reinforced cement concrete M-15 grade ordinary kilometer stone of standard design for village roads as per IRC 8-1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications
Reinforced cement concrete M-15 grade village board of standard design fixing in position including painting and printing etc. complete as per PWD specifications
Cautionary sign board 600x600x600mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 3mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mmmm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .
Informatory sign board 600x600mm square as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. with retro reflective high intensity Microprismatic grade sheeting fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .
Advance Direction sign board 1200x900mm rectangular per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. grade sheeting fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminum Composite material (ACM) sheeting having aluminum skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminum alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 .
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size
aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012
Overhead sign board 12000x1500mm simply supported type double sided as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 . fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with uitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 40x40x6mm angle iron supported on designed double support system of MS pipe and plates in the form of a simply supported type truss made with 350NB pipe @50kg per mtr as vertical support, 50NB pipe @ 4.50kg per mtr and 40NB pipe @ 3.61kg per mtr for truss including base plates, gusset plates, designed RCC foundation for fixing in ground complete as per clause 802 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012.
Construction of 10' High Retaining Wall
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Squared rubble masonry coursed (coursed rubble) in foundations and plinth in Cement mortar 1:6
Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
Raised cement pointing 1:2 on stone walls
Construction of 10' High Retaining Wall
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Squared rubble masonry coursed (coursed rubble) in foundations and plinth in Cement mortar 1:6
Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type
Construction of 8' High Retaining Wall
Stone filling behind retaining walls.
Construction of 10' High Retaining Wall
Construction of 1½' x 1½' Side Drain
Cement concrete 1:4:8 mixing by mechanical means using concrete mixer volumetric type
Squared rubble masonry coursed (coursed rubble) in foundations and plinth in Cement mortar 1:6
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
12.5 mm thick cement plaster 1:5
Floating coat of 1:5 thick neat cement paid in one opreation to the toping on plaster of haif thick
Construciton of Covered Drain
Squared rubble masonry coursed (coursed rubble) in foundations and plinth in Cement mortar 1:6
Earth work in excavation of foundation of structures as per drawing and technical specification 305.1, including setting out, construction of shoring and bracking, removal of stumps and other deleterious material & disposal up to 50 mtrs, dressing of sides and bottom and backfilling in trenches with approved material.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Per sqm
Per Qtl.
Construciton of Covered Drain
Construction of 3mtr. Span Slab Type Culvert
Cement concrete 1:4:8 mixing by mechanical means using concrete mixer volumetric type
Cement concrete 1:3:6 mixing by mechanical means using concrete mixer volumetric type
Earth work in excavation of foundation of structures as per drawing and technical specification 305.1, including setting out, construction of shoring and bracking, removal of stumps and other deleterious material & disposal up to 50 mtrs, dressing of sides and bottom and backfilling in trenches with approved material.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in Foudation
Per sqm
Centring and shuttering for slab culvert upto 3 mtr. Span
12.5mm thick Plastering with cement mortar 1:4
Painting of parapet walls of CD work with cement paint
First class brick on edge paving or flooring laid over and in cement sand mortar 1:5 in ordinary bonded courses or in herring bone or other special courses, to templates, over dressed foundation and to correct longitudinal and cross slopes as shall be required by the Engineer-in-charge. All joints shall be filled with mortar and struck flushed as the work proceeds.
Construciton of Covered Drain
Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Construction of 1½' x 1½' Side Drain
Interlocking Paver Blocks
Providing and laying 80 mm thick factory made cement concrete interlocking Paving blocks of M- 40 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge.
Construciton of Covered Drain
Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Construction of Cement Concrete Pavement
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site with transit mixer with lead up to 10 km., laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of un-reinforced M-35 grade concrete pavement with dowel jointed over a prepared sub base with 43 grade OPC cement of concrete, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batch mix plant as per approved mix design, transported to site in transit mixer with lead up to 10 km. laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per clause 602 of MORT&H 5th Revision
Shuttering for precast R.C.C. battens/cement concrete block in situ such as staggered RC blocks arrow and plain cement concrete block.
Squared rubble masonry coursed (coursed rubble) in foundations and plinth in Cement mortar 1:5
Add 1% Cultural Cess
MAINTENANCE OF ROAD FOR 5 YEARS (ONE YEAR DEFECT LIABILITY PERIOD + FOUR YEARS MAINTENANCE PERIOD) IN DISST. PATHANKOT
Add 1% Cess Cancer Cess Charge
For 3rd year maintenance
For 4th year maintenance
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.30 MB
BOQ_312025.xls
BOQ • 0.28 MB
TechnicalandCopaConditions.pdf
Tender Documents • 6.77 MB
ScanBOQ.pdf
Tender Documents • 9.88 MB
DNITDocumentsShahpurKandiBaniLodhi.pdf
Tender Documents • 37.93 MB
Download all tender documents and submit your bid