GEMC-511687774094356
Awarded to AMES IMPEX ELECTRICALS PVT LTD
₹5.1 Cr
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| MAIN SUPPLY-8000 kVA | "AMES-MAKE" / 8000kVA 11kV/3.6kV ONAN Transformer | 85042200 | 2 Number | 7,511,000 | 15,022,000 |
| MAIN SUPPLY-6300 kVA | "AMES-MAKE" / 6300kVA 11kV/3.6kV ONAN Transformer | 85042200 | 4 Number | 6,296,000 | 25,184,000 |
| MAIN SUPPLY-3500 kVA | "AMES-MAKE" / 3500kVA 11kV/3.6kV ONAN Transformer | 85042200 | 2 Number | 3,663,920 | 7,327,840 |
| EXTRA OIL-8000 kVA | "APAR-MAKE" / EXTRA OIL - 8000 KVA | 85049010 | 1 LOT | 70,800 | 70,800 |
| EXTRA OIL-6300 kVA | "APAR-MAKE" / EXTRA OIL - 6300 KVA | 85049010 | 1 LOT | 47,200 | 47,200 |
| EXTRA OIL-3500 kVA | "APAR-MAKE" / EXTRA OIL - 3500 KVA | 85049010 | 1 LOT | 41,300 | 41,300 |
| 1-TYPE TEST 8000 Kva | TANK PRESSURE TEST for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 2-TYPE TEST 8000 Kva | TANK VACUUM TEST for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 3-TYPE TEST 8000 Kva | MEASUREMENT OF ACOUSTIC NOISE LEVEL AS PER NEMA TR-1 (SPECIAL TEST) for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 4-TYPE TEST 8000 Kva | TEMPERATURE RISE TEST for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 5-TYPE TEST 8000 Kva | LIGHTNING IMPULSE(FULL & CHOPPED WAVE) TEST ON WINDINGS (AS PER IEC 60076-3) for 8000 kVA transformer | 00998346 | 1 Number | 472,000 | 472,000 |
| 6-TYPE TEST 8000 Kva | MEASUREMENT OF THE HARMONICS OF THE NO LOAD CURRENT for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 7-TYPE TEST 8000 Kva | ZERO SEQUENCE IMPEDANCE MEASUREMENT for 8000 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 1-TYPE TEST 6300 Kva | TANK PRESSURE TEST for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 2-TYPE TEST 6300 Kva | TANK VACUUM TEST for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 3-TYPE TEST 6300 Kva | MEASUREMENT OF ACOUSTIC NOISE LEVEL AS PER NEMA TR-1 (SPECIAL TEST) for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 4-TYPE TEST 6300 Kva | TEMPERATURE RISE TEST AT A TAP CORRESPONDING TO MAXIMUM LOSSES. ((detail as per unpriced/tech spec) for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 5-TYPE TEST 6300 Kva | LIGHTNING IMPULSE((detail as unpriced/tech spec)) for 6300 kVA transformer | 00998346 | 1 Number | 250,000 | 250,000 |
| 6-TYPE TEST 6300 Kva | MEASUREMENT OF THE HARMONICS OF THE NO LOAD CURRENT for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 7-TYPE TEST 6300 Kva | ZERO SEQUENCE IMPEDANCE MEASUREMENT for 6300 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 1-TYPE TEST 3500 Kva | TANK PRESSURE TEST for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 2-TYPE TEST 3500 Kva | TANK VACUUM TEST for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 3-TYPE TEST 3500 Kva | MEASUREMENT OF ACOUSTIC NOISE LEVEL AS PER NEMA TR-1 (SPECIAL TEST) for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 4-TYPE TEST 3500 Kva | TEMPERATURE RISE TEST AT A TAP CORRESPONDING TO MAXIMUM LOSSES (detail as per unpriced/tech spec) for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 5-TYPE TEST 3500 Kva | LIGHTNING IMPULSE (detail as per unpriced/tech spec) for 3500 kVA transformer | 00998346 | 1 Number | 250,000 | 250,000 |
| 6-TYPE TEST 3500 Kva | MEASUREMENT OF THE HARMONICS OF THE NO LOAD CURRENT for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 7-TYPE TEST 3500 Kva | ZERO SEQUENCE IMPEDANCE MEASUREMENT for 3500 kVA transformer | 00998346 | 1 Number | 1 | 1 |
| 1-MANDATORY SPARES | HV bushing with metal parts & gaskets -8000 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 2-MANDATORY SPARES | HV bushing with metal parts & gaskets -6300 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 3-MANDATORY SPARES | HV bushing with metal parts & gaskets-3500 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 4-MANDATORY SPARES | LV bushing with metal parts & gaskets-8000 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 5-MANDATORY SPARES | LV bushing with metal parts & gaskets-6300 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 6-MANDATORY SPARES | LV bushing with metal parts & gaskets-3500 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 7-MANDATORY SPARES | LV Neutral bushing with metal parts & gaskets-8000 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 8-MANDATORY SPARES | LV Neutral bushing with metal parts & gaskets-6300 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 9-MANDATORY SPARES | LV Neutral bushing with metal parts & gaskets-3500 KVA | 85049010 | 1 Number | 53,100 | 53,100 |
| 10-MANDATORY SPARES | WTI with contacts-8000 KVA | 85049010 | 1 Number | 29,500 | 29,500 |
| 11-MANDATORY SPARES | WTI with contacts-6300 KVA | 85049010 | 1 Number | 29,500 | 29,500 |
| 12-MANDATORY SPARES | WTI with contacts-3500 KVA | 85049010 | 1 Number | 29,500 | 29,500 |
| 13-MANDATORY SPARES | Tap changer contacts-8000 KVA | 85049010 | 1 SET | 59,000 | 59,000 |
| 14-MANDATORY SPARES | Tap changer contacts-6300 KVA | 85049010 | 1 SET | 59,000 | 59,000 |
| 15-MANDATORY SPARES | Tap changer contacts-3500 KVA | 85049010 | 1 SET | 59,000 | 59,000 |
| 16-MANDATORY SPARES | Magnetic oil gauge/oil level indicator with contacts for 8000kVA, 11kV/3.6kV | 85049010 | 1 Number | 17,700 | 17,700 |
| 17-MANDATORY SPARES | Magnetic oil gauge/oil level indicator with contacts for 6300kVA, 11kV/3.6kV | 85049010 | 1 Number | 17,700 | 17,700 |
| 18-MANDATORY SPARES | Magnetic oil gauge/oil level indicator with contacts for 3500kVA, 11kV/3.6kV | 85049010 | 1 Number | 17,700 | 17,700 |
| 19-MANDATORY SPARES | OTI with contacts for 8000kVA, 11kV/3.6kV | 85049010 | 1 Number | 29,500 | 29,500 |
| 20-MANDATORY SPARES | OTI with contacts for 6300kVA, 11kV/3.6kV | 85049010 | 1 Number | 29,500 | 29,500 |
| 21-MANDATORY SPARES | OTI with contacts for 3500kVA, 11kV/3.6kV | 85049010 | 1 Number | 29,500 | 29,500 |
| 22-MANDATORY SPARES | Buchholz relay complete for 8000kVA, 11kV/3.6kV | 85049010 | 1 Number | 11,800 | 11,800 |
| 23-MANDATORY SPARES | Buchholz relay complete for 6300kVA, 11kV/3.6kV | 85049010 | 1 Number | 11,800 | 11,800 |
| 24-MANDATORY SPARES | Buchholz relay complete for 3500kVA, 11kV/3.6kV | 85049010 | 1 Number | 11,800 | 11,800 |
| 25-MANDATORY SPARES | Float with contact for Buchholz relay for 8000kVA, 11kV/3.6kV | 85049010 | 1 Number | 5,900 | 5,900 |
| 26-MANDATORY SPARES | Float with contact for Buchholz relay for 6300kVA, 11kV/3.6kV | 85049010 | 1 Number | 5,900 | 5,900 |
| 27-MANDATORY SPARES | Float with contact for Buchholz relay for 3500kVA, 11kV/3.6kV | 85049010 | 1 Number | 5,900 | 5,900 |
| 28-MANDATORY SPARES | Set of gaskets (other than that with bushing) for 8000kVA, 11kV/3.6kV | 85049010 | 1 SET | 118,000 | 118,000 |
| 29-MANDATORY SPARES | Set of gaskets (other than that with bushing) for 6300kVA, 11kV/3.6kV | 85049010 | 1 SET | 118,000 | 118,000 |
| 30-MANDATORY SPARES | Set of gaskets (other than that with bushing) for 3500kVA, 11kV/3.6kV | 85049010 | 1 SET | 118,000 | 118,000 |
| 31-MANDATORY SPARES | Set of valves for 11/0.433kV, 1600KVA | 85049010 | 1 SET | 177,000 | 177,000 |
| 32-MANDATORY SPARES | Set of valves for 11/0.433kV, 2000KVA | 85049010 | 1 SET | 141,600 | 141,600 |
| 33-MANDATORY SPARES | Set of valves for 11/3.45kV, 2500KVA | 85049010 | 1 SET | 141,600 | 141,600 |
| 34-MANDATORY SPARES | Pressure relief Device for 11/0.433kV, 1600KVA | 85049010 | 1 Number | 29,500 | 29,500 |
| 35-MANDATORY SPARES | Pressure relief Device for 11/0.433kV, 2000KVA | 85049010 | 1 Number | 29,500 | 29,500 |
| 36-MANDATORY SPARES | Pressure relief Device for 11/3.45kV, 2500KVA | 85049010 | 1 Number | 29,500 | 29,500 |