Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55,466.12Accepted-AOC | ₹55,466.12 | L1 | Accepted-AOC Accepted |
| 2 | L2₹56,581+₹1,114.88 (2.01%)Rejected-AOC | ₹56,581+₹1,114.88 (2.01%) | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | S Pandimurugan H2 | mageswari H1 |
|---|---|---|---|---|---|
| 1.01 | Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil as Directed by the Departmental officers | 48 | RM | 194.09 ₹9,316.32 Lowest | 198 ₹9,504 |
| 1.02Supplyof Materials | |||||
| 1.03 | 50 mm HDPE pipe PN 12.5 | 48 | RM | 142.17 ₹6,824.16 Lowest | 145 ₹6,960 |
| 1.04 | Lowering 50mm HDPE Pipe pipes and specials to trench and
laying to proper grade and alignment and as
directed by the TWAD Officers | 48 | RM | 18.75 ₹900 Lowest | 19 ₹912 |
| 1.05 | Refilling the Excavated trenches after laying of 50 mm HDPE Pipe Complete as per standard Specification | 48 | RM | 26.9 ₹1,291.2 Lowest | 27 ₹1,296 |
| 1.06 | supply and delivery of nylon rope | 150 | sqm | 39.99 ₹5,998.5 Lowest | 41 ₹6,150 |
| 1.07 | supply and delivery 2" Hose collar | 2 | cum | 1,299.74 ₹2,599.48 Lowest | 1,326 ₹2,652 |
| 1.08 | 110mm flange socket | 2 | cum | 1,679.66 ₹3,359.32 Lowest | 1,714 ₹3,428 |
| 1.09 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 3HP | 1 | cum | 12,819.54 ₹12,819.54 Lowest | 13,079 ₹13,079 |
| 1.10 | PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER | 60 | Rm | 205.96 ₹12,357.6 Lowest | 210 ₹12,600 |
Tender Value
₹70,000
Closing Date
28 Jan 2026, 3:00 pmClosed
Sivakasi Corporation Commissioner
Sivakasi Corporation Office Rathinam Nagar Sivakasi
Providing HDPE pipe line at Zone 1 and 2thaal odai in Sivakasi City Municipal Corporation
2026_MAWS_646238_18
3001/2025/E1
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
Works
30 days
sivakasi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Yes
29 Apr 2026
24 Jan 2026
28 Jan 2026
24 Jan 2026
28 Jan 2026
24 Jan 2026
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil as Directed by the Departmental officers
Supplyof Materials
50 mm HDPE pipe PN 12.5
Lowering 50mm HDPE Pipe pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers
Refilling the Excavated trenches after laying of 50 mm HDPE Pipe Complete as per standard Specification
supply and delivery of nylon rope
supply and delivery 2" Hose collar
110mm flange socket
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 3HP
PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_775391.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.62 MB
BOQ_775391.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .