Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.5 LAdmitted-Finance | -10.19% | ₹4.5 L | L1 | Admitted-Finance |
| 2 | L2₹4.5 L+₹5,399.43 (1.20%)Admitted-Finance | -9.11% | ₹4.5 L+₹5,399.43 (1.20%) | L2 | Admitted-Finance |
| 3 | L3₹4.6 L+₹8,449.10 (1.88%)Admitted-Finance | -8.50% | ₹4.6 L+₹8,449.10 (1.88%) | L3 | Admitted-Finance |
| 4 | L4₹4.6 L+₹10,198.92 (2.27%)Admitted-Finance | -8.15% | ₹4.6 L+₹10,198.92 (2.27%) | L4 | Admitted-Finance |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
3 Jul 2026, 6:00 pmClosed
Executive Engineer (Electric)
PWD CAMPUS BHARATPUR
Electrical Repair and AC work at Circuit House Dholpur.
2026_CEPWD_572023_1
NIT-07-2026-27
Open Tender
Electrical Works
Percentage
120 days
Dholpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
As per NIT
₹10,000
Yes
Bharatpur
12 Jul 2026
30 Jun 2026
6 Jul 2026
30 Jun 2026
3 Jul 2026
30 Jun 2026
1 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. | - | - | - | - |
| 2 | 25 mm | 30 | Mtr. | - | - |
| 3 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. | - | - | - | - |
| 4 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. | 50 | Mtr. | 142 | ₹7,100 |
| 5 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. | - | - | - | - |
| 6 | Modular MCB 6 A to 32 A DP | 6 | Each | - | - |
| 7 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. | 8 | Each | 460 | ₹3,680 |
| 8 | Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) | - | - | - | - |
| 9 | Cooling capacity 6800-7000 Watt, ISEER not less then 3.8 | 4 | Each | - | - |
| 10 | Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 | 2 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.32 MB
BOQ_1017821.xls
BOQ • 0.30 MB
06Month.pdf
Tender Documents • 4.40 MB
Annexure.pdf
Other Document • 1.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .