Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.4 L+₹1.4 L (13.0%)Rejected-AOC H NO 111 553 64 CATTLE POUND TOWARDS AVA HILL CAMP ROAD ARUVANKADU NILGIRIS DIST TAMIL NADU 643 202 | THE NILGIRIS | TAMIL NADU | 643202 | L2 | Rejected-AOC Accepted | |
| 3 | L3₹13.2 L+₹2.2 L (19.9%)Rejected-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L3 | Rejected-AOC Accepted |
Tender Value
Refer Docs
EMD Value
₹23,800
Closing Date
3 Dec 2020, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIR/ REPLACEMENT OF DISTRIBUTION BOARD AND BLDG EARTHING INCLUDING REPAIR OF EXHAUST FAN, GEYSERS ETC CONNECTED WORKS AND REPAIRS TO SPLIT/ WINDOW TYPE AC REFRIGERATOR AND DEEP FREEZER AT WELLINGTON AREA UNDER GE WELLINGTON
2020_MES_384332_1
8602/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Wellington
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹23,800
Yes
16 Feb 2021
7 Oct 2020
5 Dec 2020
8 Oct 2020
3 Dec 2020
21 Oct 2020
Amount
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 1 way 240 volts, single door type including necessary dummy plate and make good with existing surface, and including necessary civil works complete all as specified and directed.
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 2 way 240 volts, single door type including necessary dummy plate and make good with existing surface, and including necessary civil works complete all as specified and directed.
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 4 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and make good with existing surface, and including necessary civil works complete all as specified and directed.
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and make good with existing surface, and including necessary civil works complete all as specified and directed.
Taking down unserviceable DBs with MCBs and Supply and fix MCB DB TPN 4 way 415 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and make good with existing surface, and including necessary civil works complete all as specified and directed.
Taking down unserviceable MCB and supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed. Make: L&T Cat No BB10320C or equivalent in Legrand/ ABB
Taking down unserviceable MCB and supply and fix MCB SPN 230V, 32 Amps capacity all as specified and directed. Make: L&T Cat No. BB20320C or equivalent in Legrand/ ABB
Taking down unserviceable MCB and supply and fix MCB SPN 230V, 63 Amps capacity all as specified and directed. Make: L&T Cat No. BB20630C or equivalent in Legrand/ ABB
Taking down unserviceable MCB and supply and fix MCB TPN 415V, 32 Amp capacity all as specified and directed. Make: L&T Cat No. BB40320C or equivalent in Legrand/ ABB
Taking down unserviceable MCB and supply and fix MCB TPN 415V, 63 Amp capacity all as specified and directed. Make: L&T Cat No. BB40630C or equivalent in Legrand/ ABB
Taking down unserviceable RCCB of any size and supply and fix RCCB DP rating 25 Amp sensitivity 30 mAmp capacity all as specified and directed. Make: L&T Cat No. BG202503 or equivalent in Legrand/ ABB
Taking down unserviceable RCCB and supply and fix RCCB DP rating 40 Amp sensitivity 30 mAmp capacity all as specified and directed. Make: L&T Cat No. BG204003 or equivalent in Legrand/ ABB
Taking down unserviceable RCCB and supply and fix RCCB DP rating 63 Amp sensitivity 30 mAmp capacity all as specified and directed. Make: L&T Cat No. BG206303 or equivalent in Legrand/ ABB
Taking out unserviceable DB of any size and supply, install, testing and commissioning of factory made LT Distribution board, TPN 415 Volts, 50 Hz, 250 Amps capacity outdoor cubical type LT disribution switch gear and control gear, leg mounted, totally enclosed, cubical type modular compartment , dust and vermin proof IP-54 with neoprene gasket, fabricated out of CRCA sheet of thick ness not less than 3.15 mm complete with 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for incoming, outgoing connections comprising for the following including necessary PCC foundation of minimum 0.20 Mtr height positioned and fixed with suitable nuts, bolts, washers, etc to the pedestal and connecting all incoming and outgoing cables complete all as specified and directed. (Baffle Range) (a) Aluminium Bus bar four wire system 415 volts mounted on procelain heat shrinkable insulator sleeve suitable for 400 Amps for phases and 200 Amps for neutral. b) LED type Indicating lamps for all the three phase with different colour lamp red,yellow and green.- 1 set c) Digital multi function panel meter measuring voltage, Amps and frequency with suitabe CTs and backup protection - 1 No d) Danger notice board of size 200mm x 150mm x 1.6mm thick of mild steel sheet vitreous enamelled white and letter figure and convention skull and bones of signal red colour and fixed/revited with panel- 02 Nos e) Incoming i) MCCB 4 pole , 35 KA, 250 Amps, 415 volts - 01 No f) Outgoing i) MCCB 4 pole, 25 KA, 100 Amps, 415 volts - 02 Nos ii) MCCB 4 pole, 25 KA, 63 Amps, 415 volts - 03 Nos iii) MCCB 4 pole, 16 KA, 40 Amps, 415 volts - 01 No
Taking down old unserviceable DB of any type and supply and fixing Weather Proof IP rated, CPRI Certified, Thermo Plastic Polycarbonate, Dust & Water protected, Anti corrosive, Insulated, Shock Proof, UV Resistant Distribution Board with Hinges in individual compartments along with Transparent/Non-Transparent combination all as specified and directed. Model No: DB4: Dim:896L x 628H x 206D (mm) of Make Hensal or equivalent. (10 Block Lower/Upper) General Specification: Type of enclosure : thermoplastic Polycarbonate Panel Size : 896x628x206mm Busbar Rating : 25 x 6 mm (150A) Degree of protection : IP66, Indoor type wall mounted System Voltage : 415 V, 50 Hz, 4 wire+E Cable entry : IN/OUT from bottom Finish Shade Enclosure & Accessories : RAL 7035 Mounting Structure : RAL 7016 Incomer: 63A FP 25KA MCCB Microprocessor - 1 No RYB Indicating lamps, 2A Fuse terminal blocks-3 nos Disconnecting terminal blocks-1 Outgoing: 63 Amp FP 30mA RCCB - 01 No 32A MCB DP, 10KA - 10 Nos 6Amp SP 10 KAMCB - 02 Nos 10 sqmm terminal blocks 32A - 20Nos 16 Sqmm terminalblock- 4 Nos 4 Sqmm terminalblock- 4 Nos Cable in - 35 Sqmm x 3.5 Core Cable out - 6sqmm x 2 core - 10 nos, 16 Sqmm x 4 Core - 1 No, 2.5 Sqmm x 2 Core - 2 Nos
Repair/Spray painting to outdoor/indoor LT Distribution board complete portion of any size including preparing the surface by removing the peeled old paint with scrapper, cleaning the surface and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour approved and welding/ replace of door hinges complete all as specified and directed
Takingdown unserviceable plug and socket and Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20A SP MCB all as specified and directed.
Taking down Submain wiring with aluminium conductor along with PVC Conduit and supply and fix for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
All as per Item No 18 hereinbefore but in and including casing caping all as specified and directed.
Taking down Submain wiring with aluminium conductor along with PVC Conduit and supply and fix for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
All as per Item No 20 hereinbefore but in and including casing caping all as specified and directed
Earthing complete with galvanized steel earth platee electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the platee not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical platee No 3 connected to earth testing point including necessary excavation, and earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS bars at 100 c/c , funnel ,watering pipe etc. all specified and directed including testing on completion .
All as per item No. 22 hereinbefore but Earth strip of size 25 x 4 mm all as specified and directed
All as per item No. 22 hereinbefore but Earth strip of size 32 x 6 mm all as specified and directed
Air termination, single pointed aluminium rod 12mm dia and 300 mm / 600 mm long all as specified and directed.
PCC pit (for fixing of Air termination rod on roof) with PCC 1 :3 : 6 type C1 using 20mm graded stone aggregate all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia, 25mm long hex. head screw all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including fixed in repairs all as specified and directed.
Galvanised iron strip 32 x 6mm buried in ground all as specified and directed.
Galvanised iron strip 32 x 6mm buried in ground including fixed in repairs all as specified and directed.
Cutting, chases in stone masonry wall/ concrete floor/ roof for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exceeding 10cm girth all as specified and directed.
Top plug 6 Amp all as specified and directed. Make C&S Cat Part No. CG28014NR or equivalent Anchor/ Havells
Top plug 16 Amp all as specified and directed. Make C&S Cat Part No. CG28015NR or equivalent Anchor/ Havells
Handy/ Add-on Power Extension Box 2 Nos Luminous 6A Switch with 3 Nos. 6Amp Multi Sockets all as specified and directed. Make: C&S Cat Part No CG25002WNR or equivalent Anchor/ L&T
Handy/ Add-on Power Extension Box 2 Nos Luminous 16A Switch with 4 Nos. 6/16 Amp Sockets all as specified and directed. Make: C&S Cat Part No CG25008WNR or equivalent Anchor/ L&T
Night light Adore LED lamp 0.5W Bear/ Rabbit/ Panda, holder type all as specified and directed. Make Havells Cat Part No. LHEHDDP7IN1X010 or equivalent Phillps/ CG.
Taking out old unserviceable Flame proof Flouresent tubelight fitting and supply and fix tube light fitting LED flame proof fittings 2 x 20 watt, IP 65 protection made of aluminium alloy LM6, with electronic driver connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Crompton Cat Part No: EXTN2LT8-16/20 or equivalent Philips/ Bajaj/ sudhir
Taking out old unserviceable Flouresent tube light rod, and supply and fix tube light fitting LED polycarbonate T8 tube with in built driver with metal heat sink double sided connection complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Crompton Cat Part No: LT8-8-565-2 or equivalent Philips/ Bajaj/ sudhir
Taking out old unserviceable flame proof/ weather proof Rotary type isolator, Supply and fix flame proof/ weather proof Rotary type isolator with direct entry in LM-6 suitable for 16A single pole on-off flame proof switch. Make : Sudhir/ C&S/ Crompton.
Self adhesive PVC Elctrical Insulation Tape size 0.125 mm x 18 mm x 8 Mtr all as specified and direcetd. Make : Steelgrip (Pidilite) equivalent to Anchor or other Makes.
Taking down unserviceable building security light and supply and fix for LED Security Light fitting of 25 Watt comprising of epoxy powder coated housing enclosed with glass cover in frame with protection IP 65 complete with all accessories and lamp colour white and fixing in and including GI Bracket of suitable size /dia all as specified and directed. Make . CG Cat No LSTS-25-CDL or equivalent in Havells / Phillips/ Bajaj
Taking down exhaust fan of any size and make carefully from any height after disconnecting the electric connection and refixing the same after necessary repairs / servicing , including reconnecting electrical connection and testing complete all as specified and directed. Note:- (i) Rate deemed to be inclusive of Dismantling the fan, Servicing ,cleaning , oiling , greasing and assemble the fan properly including tightening all the bolts , nuts screws clamps etc complete. (ii) Spares required for repairs of exhaust fan and rewinding of exhaust fan will be measured and paid separately.
Rewinding of Exhaust fan motor with super enamelled copper winding wire of suitable gauge after cutting and removing the burnt out existing winding, including varnishing, heating, providing fresh insulating material for 300 mm sweep all as specified and directed.
Rewinding of Exhaust fan motor with super enamelled copper winding wire of suitable gauge after cutting and removing the burnt out existing winding, including varnishing, heating, providing fresh insulating material for 375/ 380/ 450 mm sweep all as specified and directed.
Taking out unserviceable ball bearings and supply and fix new ball bearing of suitable size for any make of Exhaust fan 300/ 375/ 380/ 450 mm sweep all as specified and directed.
Taking out old unserviceable capacitor of any size Supply and fix Capacitor 2.5mF + 5% all as specified and directed. Make: Keltron / L&T or equivalent to any make ISI Marked.
Taking out unserviceable heating element and supply and fix new heating element 1.5 KW Dual clip type with rubber gasket suitable for geysers up to 25 Ltr capacity all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 1.5 KW Round type with rubber gasket suitable for geysers up to 50 Ltr capacity all as specified and directed.
Taking out unserviceable heating element and supply and fix new heating element 1.5 KW Triangle type with rubber gasket suitable for geysers up to 50 Ltr capacity all as specified and directed.
Taking out unserviceable thermostat and supply and fix new thermostat suitable for 25 Ltr capacity geyser, range 30° C to 80° C and acting at 70°C all as specified and directed.
Taking out unserviceable PVC connections and supply and fix new PVC connection up to 600 mm in length suitable to connect GI pipe 15 mm bore to hot water outlet of geyser all as specified and directed. . Make: Kohinoor / Prayag or eqivalent
Numbering the Geyser/ Water Cooler/ Solar Water Heater/ Centrifigul Pump / Split / Window AC etc, black paint with back ground yellow paint complete all as specified and as directed.
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned rotory/receprocating type compressor 1.5 Ton capacity obtained from the rechange of old compressor including cleaning the refrigeration circuit withappropriate cleaning agents, flushing throught with CO2/N2 removal of complete dirt oil and certain, etc. Pressure testing dehydration, Vacumising, charging R-22/33A gas, testing and commissioning of the 1.5 Ton capacity all as specified and as directed.
Taking out defective condenser fan blade of split type A/C 1.5 Ton capacity and supply and Fix inf new fan blade of same type balancing for smooth rotation in the casing and testing all as specified and directed.
cleaning/flushing out the refrigeration system thoroughly with CO2/N2. vaccumising and charging with refrigerant gas and compessor oil testing at workshop and commissioning the system of 1.5 ton capacity split/ Window type A/C all as specified and directed.
Supply and fix in replacement inner unit fan motor with runner of suitable capacity for split / Window type A/Cs of cap 1.5 ton all as specified and directed.
Supply and fix in replacement running capacitor 36/45 mfd, 3 pin suitable for split/ Window Acs of cap 1.5 ton all as specified and directed. Make- Efcos, Sycap, Keltron
Supply and fix indoor fan capacitor 1.5 mfd suitable for split/ Window ACs of cap 1.5 ton all as specified and directed. Make- Sriram, Reneutrol, CSR 127
Supply and fix in replacement filter suitable for split ACs of cap 1.5 ton all as specified and directed. Make- Sriram, Reneutrol, CSR 127)
Supply and fix indoor evaporator unit suitable for split ACs of cap 1.5 ton all as specified and directed. Make-Sriram, Reneutrol, CSR 127
Supply and fix in replacement drain out pipe of required size and length of indoor unit suitable for split ACs of cap 1.5 ton all as specified and directed. Make-Sriram, Reneutrol, CSR 127)
Taking out the damaged suction line pipe and supply and fixing new copper pipe of size 1/2" in brazing, pressure testing for 1.5 Ton capacity split type AC all as specified and directed.
Supply and charging of refrrigerent gas R22/33A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed. Make - Mafron / Floron
Supply and charging of refrrigerent gas R134A/R410A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed. Make - Mafron / Floron
Supply and fix in replacement PVC insulated and sheathed flexible cable 3 core stranded copper conductore of size 4.0 Sqmm in proper size saddle 1100 volts grade after taking out old unserviceable one including electrice connection complete all as specified and as directed. Make- Finolex, Polycab, Plaza
Supply, fix in replacement relay 5 pin type suitable for 1.5 Ton capacity all as specified and as directed. Make-Sriram, Arvind / Annapuma.
Supply, fix in replacement Over load protector suitable for 1.5 Ton capacity all as specified and as directed. Make-Sriram, Arvind/Annapuma.
Supply, fix in replacement thermostatic switch suitable for window/ split type AC 1.5 Ton capacity all as specified and as directed. Make-Indofoss / Danfoss
Supply, fix in replacement Air conditioner Kit suitable for window / Split type AC 1.5 ton cap having cabinet box, cooling coil, condenser unit all as specified and directed. Make Samsung, Voltas
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including deaning the refrigeration circuit with appropriate cleaning agents, flushing throught with CO2/N2 brazing the line . Pressore testing rectification of leakages,dehydration, Vacumising, charging R-134A gas. Replacement of copper pipe, copper strainer, topping up compressore oil incl transportation of the unit to the workshop testing and commissioning of 165 to 220 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, samsang.
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including deaning the refrigeration circuit with appropriate cleaning agents, flushing throught with CO2/N2 brazing the line . Pressore testing rectification of leakages,dehydration, Vacumising, charging R-134A gas. Replacement of copper pipe, copper strainer, topping up compressore oil incl transportation of the unit to the workshop testing and commissioning of 250 to 350 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, samsang.
Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agents, flushing throught with CO2/N2 brazing the line . Pressure testing rectification of leakages,dehydration, Vacumising, charging R-134A gas. Replacement of copper pipe, copper strainer, topping up compressore oil incl transportation of the unit to the workshop testing and commissioning Deep freezer of Capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, samsang.
Gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, ropping up compressor oil including transportation of the unit to the work shop testing and commisioning the refrigerators of 165 to 220 Ltr Cap all as specified and directed. Make:- LG , Whirlpool, samsang.
Gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, ropping up compressor oil including transportation of the unit to the work shop testing & commisioning the refrigerators of 250 to 350 Ltr Cap all as specified and directed. Make:- LG , Whirlpool, samsang.
Gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, ropping up compressor oil including transportation of the unit to the work shop testing & commisioning the p Freezer of capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, samsang.
Supply, fix in replacement relay suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Supply, fix in replacement overload protector suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Supply, fix in replacement thermostatic switch of auto de-frost suitable for Refrigerator /deepfrezer of any capacity as per existing modal all as specified and directed. Make :-Sriram, Indfoss, Danfoss
Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 165 to 220 Ltr Cap all as specified and directed
Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 250 to 350 Ltr Cap all as specified and directed
sree devi construction
UNIQUE INDIA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .