| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.0 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹8.7 L+₹65,305 (8.12%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Competent Authority found bid tech not suitable. |
Tender Value
Refer Docs
EMD Value
₹21,000
Closing Date
3 Feb 2022, 2:00 pmClosed
Er. Rajeev Kumar Dixit SE OandMC-IV DTPS Kasimpur
Office of the SE OandMC-IV DTPS Kasimpur Aligarh Mobile No 9415900113
Electrical Maintenance Works in 220KV and 132KV Switchyards and Cleaning of various outdoor and Indoor Electrical Equipments of B and C TPS
2022_RVUNL_670470_1
ET-50/OandMC-IV/DTPS/EMD I CTPS/2021-22
Open Tender
Repair and Maintenance Works
Fixed-rate
365 days
Office of the SE OandMC-IV DTPS Kasimpur
As per Tender Documents
4 documents required · 4 mandatory
₹1,239
SAO CFAandBO HTPS Kasimpur Aligarh
₹21,000
9 Jun 2022
3 Jan 2022
5 Feb 2022
3 Jan 2022
3 Feb 2022
3 Jan 2022
3 Jan 2022 - 3 Feb 2022
Amount
Dismantling of damaged CT, PT & LA including Insulators and Erection & Commissioning of other new tested equipment as per following scope of work.
Replacement of damaged post insulators/post insulator with isolator arm as per following scope of work.
Maintenance of Isolators (All three phases) R.Y.B.as per following scope of work
Maintenance of Bus Bar as per following scope of work
Maintenance of Bus Bar as per following scope of work
Preventive Maintenance of SF-6 Circuit Breakers as per following scope of work.
Replacement of Gaskets & Valves of Transformers:
Replacement of Valves Gasket
Replacement of Gasket of each pole of HT Bushings
Replacement of damaged radiator of LT transformer.
Replacement/Tightening of damaged clamps (T-Clamps PG-Clamps End Clamps etc.) of CT CB Isolators etc
Providing manpower for service support for performing different tests such as Tan Delta Test, Primary Injection Test, Circuit Breaker Timing, Contact Resistance etc. of CTs, PTs, CBs, CVTs, isolators etc. as per following scope of work
Tightening of flexible jumpers & nut-bolts, earth strips etc of one bushing of Unit # 07 Generator bushing/GT LV side maintenance
Replacement of damaged flexible jumpers of one bushing of Unit # 07 Generator bushing/GT LV side maintenance
DG set maintenance of ‘B’ & ‘C’ TPH (Providing manpower for service support for replacement of damaged rim gear, self, balancing of DG set etc.
C Thermal Power Station
Cleaning of 19 Nos LT Transformers
Cleaning of Transformer Yard of R1 R 2 etc
Cleaning of Generator panels of UCR of Unit No 7 including other panels
Cleaning of Generating Transformer of Unit No 7
Cleaning of 11KV duct of all three phases from Generator to GT of Unit No 7
Cleaning of Station Transformer R 1 and R2
Cleaning of PTs CTs of 132 /220KV Outdoor
Cleaning of battery room of stage V and VI etc
Cleaning of SEE panels
Cleaning of Circuit Breakers of 220KV/132KV Feeders
B Thermal Power Station
Cleaning of 15 Nos. of LT Transformers
Cleaning of various panels in MCR
Cleaning of Circuit Breakers of 220KV/132KV Feeders
Cleaning of PTs and CTs of 220KV/132KV Feeders
Cleaning of Battery Room of Stage III and IV including other areas
Cleaning of ICT 1T and 2T
Cleaning of 9T and10T station transformer
Cleaning of PLCC carrier panels
VISION ENGINEERING COMPANY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .