Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹2.6 CrAccepted-AOC | ₹2.6 Cr | 1st | Accepted-AOC ok |
| 2 | 2nd₹2.7 Cr+₹5.8 L (2.22%)Rejected-Finance JIND JIND HARYANA | JIND | HARYANA | 126101 | ₹2.7 Cr+₹5.8 L (2.22%) | 2nd | Rejected-Finance 2nd Lowest |
| 3 | 3rd₹2.7 Cr+₹10.6 L (4.06%)Rejected-Finance H NO 74 E STREET NO 11 JAWAHAR NAGAR HISAR HARYANA INDIA PIN NO 125001 | HISAR | HARYANA | 125001 | ₹2.7 Cr+₹10.6 L (4.06%) | 3rd | Rejected-Finance 3rd Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
5 Aug 2021, 5:00 pmClosed
Executive Engineer
Provl Divn Narwana
PERIODICAL RENEWAL BY WAY 30MM THICK BITUMINOUS CONCRETE AND 5 YEARS PAID MAINTENANCE COST ON NH-352 (BARODA) - KHAPRAN-BHONGRA-BUDAIN-UCHANA KHURD ROAD IN JIND DISTT (TR-07) UNDER PMGSY-II
2021_HRY_180103_1
PR
Open Tender
Civil Works - Roads
Item-rate/Agreement basic
120 days
Narwana
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹4.6 L
Yes
21 Sept 2021
17 Jul 2021
6 Aug 2021
17 Jul 2021
5 Aug 2021
17 Jul 2021
17 Jul 2021 - 17 Jul 2021
Amount
Providing and applying tack coat with penetration grade bitumen VG - 10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom as per technical clause 503 of MORT&H specifications (Based on HSR 17.26.2)
Providing and laying 30 mm bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder VG - 30 @ 5.4% per cent and processed waste plastic @ 7% of bitumen content of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of per MORTH specifications. (Based on HSR17.31.4) Note: If bitumen required is this account more than 5.4% as per job mix formula no extra payment will be made, extra bitumen required will be considered as incidental to work.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. (HSR 34.26) Note:- Before start of work the contractor shall give brand , batch no. , manufacturing date of the material to be used and get approved the same from Engineer-In-Charge before use.
Construction of Embankment (for berms) with approved material obtained from borrow pits, including compensation of earth, with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2, as per technical clause 305 of MORT&H specifications (Based on HSR 17.6)
Supplying and fixing of single mould twin shank reflective road studs made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values @ ASTM E 809 & ASTM D 4280. The detailed specifications and the product shall conform to ASTM D4280 and ASTM E 809. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 like abrasion resistance and fixed to the road surface using the epoxy adhesive. Two cylinderical polymer shanks of not less than 20 mm diameter and not less than 30 mm length shall be moulded in the RPM body. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl Methacrylate conforming to ASTM D788. The supplier shall provide a 2 years warranty for satisfactory field performance as per clause 804.7.3 of MORT&H 5th revision specifications. (HSR 34.34)
Advance Direction sign board (P.I. board) 900x900 square as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 (HSR 34.12.1) Using retro reflective Sheeting Class C as per IRC 67 2012
Routine Maintenance: Routine Maintenance Cost after completion of Construction for Ist Year.
Routine Maintenance Cost after completion of Construction for IInd Year.
Routine Maintenance Cost after completion of Construction for IIIrd Year.
Routine Maintenance Cost after completion of Construction for IVth Year.
Routine Maintenance Cost after completion of Construction for Vth Year.
CHAHAL CONSTRUCITON COMPANY
kartarsinghcontractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .