Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.4 L+₹2.3 L (9.10%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
11 Dec 2024, 6:00 pmClosed
CWE
HQ CWE NO 2 DELHI CANTT-10
REPAIR/MAINT FIRE FIGHTING INSTALLATION, DISTRIBUTION LINES, FIRE HYDRANT SYSTEM PIPE/MOTOR/PUMP AND OTHER CONNECTED WORKS AT DPL COMPLEX MAYUR VIHAR, ARC COMPLEX, MAHIPALPUR AND GHITORNI AREA UNDER GE SOUTH WEST NEW DELHI
2024_MES_684670_1
CWE/SW/TOKEN-16/2024-25
Limited
Electrical and Maintenance Works
Item Rate
270 days
RESTRICTED AREA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH WEST NEW DELHI
₹57,000
27 Jan 2025
20 Nov 2024
13 Dec 2024
20 Nov 2024
11 Dec 2024
5 Dec 2024
Amount
Supply, laying, fixing and testing of heavy duty MS Pipe conforming to IS: 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. including welding, cutting, and grinding works, laid in trenches, or fixing in wall, ceiling and floor complete and making good the disturbed surface similar to existingexcavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape and painting with two or more coats of synthetic enamel paint of post office red coloras per IS- 10221, complete all as specified and as directed of following sizes as required. :
All as per item srl No. 1.00 here-in-before but 150 mm dia
All as per item srl No. 1.00 here-in-before but 100 mm dia
All as per item srl No. 1.00 here-in-before but 80 mm dia
Supplying, fixing and testing of double flanged butterfly valve of PN 1.6 rating, CI , gear/hand lever operated, with soft seated wafer, bronze/gunmetal seat and ss 304 shaft duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes complete all as specified and directed of following sizes as required. :
All as per item srl No. 2.00 here-in-before but 200 mm dia
All as per item srl No. 2.00 here-in-before but 150 mm dia
All as per item srl No. 2.00 here-in-before but 100 mm dia
All as per item srl No. 2.00 here-in-before but 80 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with matching flange, nuts, bolts, washers, gaskets and conforming to IS: 780 of following sizes complete all as specified and directed of following sizes as required. :
All as per item srl No. 3.00 here-in-before but 200 mm dia
All as per item srl No. 3.00 here-in-before but 150 mm dia
All as per item srl No. 3.00 here-in-before but 100 mm dia
All as per item srl No. 3.00 here-in-before but 80 mm dia
Supplying, fixing and testing in replacement of unserviceable gun metal branch pipe, short type, instantaneous pattern to suit hose delivery coupling of size 63 mm bore complete with gun metal solid jet nozzle of 20mm nominal size confirmin to IS:903 complete all as specified and directed.
Supplying, fixing and testing in replacement of unserviceable fire hydrant fanged landing valve, oblique type, single outlet with hose copling adaptor of size 63 mm bore made of gun metal with female mouth and cast iron wheel and instantaneous spring lock, blank cap with chain confirmin to IS:5290 complete all as specified and as directed.
All as per item srl No. 5.00 here-in-before but double headed outlet type
Supplying, fixing and testing in replacement of unserviceable synthetic fibre circular woven seamless reinforcement jacketed coupling with type- II (reinforced rubber lined type), flexible fire hose made of 100% synthetic yarn, circular shaped of size 63 mm bore x 15 mtr long, complete with gun metal coupling of 63mm, with multi serrated tail and double instantaneous sprin lock arrangment comprising of heavy duty pair of gun metal male and female parts, hydralically crimped to hose with rubber cap washer and copper binding wire confirming to IS: 903 and ISI marked complete all as specified and as directed.
Supplying, fixing and testing in replacement of unserviceable swinging hose reel comprising of ply rubber hose of size 20mm(3/4"), 15m long tested with 25kg/cm²/350 psi bursting pressure with wall mounted mild steel pressel reel with 180º angle swinging with non-jamming contolling handle which shall stay at the ON/OFF position as set, wall bracket with 'U' shaped reel carrier made of CI of post office red colour finish in and including gun metal noel and shut off ball valve, heavy duty confirming to IS: 884 and ISI marked complete all as specified and as directed.
Supplying and fixing in replacement of unserviceable internal hydrant rubber washer 4mm thick of size 12mm inner diameter and 72mm outer diameter complete all as specified and as directed.
Supplying and install in replacement yard fire hydrant box, outdoor type of internal size not less than 97 X 105 cm and 60 cm width, made out of 14 SWG thick CRCA mild steel sheet, factory made, totally enclosed with front side hinged openable cover with locking arrangement and pad lock duly painted with two coat of red post office colour synthetic enamel paint on outside surface and white colour paint on inside surface over a coat of red oxide primer comprising 4 mm thick glass window of size not less than 76 X 76 cm on front side openable cover inscribed with word 'FIRE' (5 inch size) with post office red synthetic enamel paint. The box to be installed on brick pillar foundation with suitable size of MS foundation bolt grouting in and including dismantling corroded/worn out yard fire hydrant box from brick pillar foundation complete all as specified and as directed.
Supply & fixing in replacement of broken glass window size not less than 76 cm x 76 cm x 4 mm thick in yard fire hydrant box inscribed with word 'FIRE' with red post office colour synthetic enamel paint as per existing pattern complete all as specified and as directed.
M&L for fittings for flanged pipes such as Bends, Tapers, Tee Pieces (Single & double branch) any type and angle/radious and straight connecting pieces but all ends flanged complete all as specified and as directed.
M&L for dismantling and taking down corroded/worn out base frames/pit covers, any type of water supply/fire fighting installations and supply and fix new base frames/pit covers. MS angle iron frame /MS plates/MS flat or round bars including welding work,duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for painting up to 200 mm bore New MS/GI pipe with one coat of red oxide primer and two coats of red post office synthetic enamel paints on all external steel surface after throughly cleaning/scraping of old paints, rust and scale etc.before applying the primer complete all as specified and as directed.
M&L for painting of MS fire hydrant box Indoor/outdoor type of internal size not less than 97x105x60cm after throughly cleaning/scraping of old paints, preparation of surfaces with emery paper as per existing colour code duly painted with two coat of red post office colour synthetic enamel paint on front of outside surface and white colour paint on inside surface over a coat of red oxide primer comprising 4 mm thick glass window inscribed with word 'FIRE' (5 inch size) with red synthetic enamel paint and numbering of box complete all as specified and directed.
M&L for cleaning of fire pipe line duct/trench size not less than 1.50 m width and 50 cm dipth after removing of MS Cover by removing/taking up dirty water alongwith sludge and disposal the same to a safe distance including scrubbing of the internal surfaces and refixing of MS Cover complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep in any type of PCC/Hard/Dense Soil
Returning filling including leveling,watering and well ramming soil in layers not exceeding 25 cm thick all as directed by Engineer-in- Charge.
Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level.
M&L for making insertion under road without cutting of road for laying of MS/GI pipe line up to 150 mm bore by using mechanically operated machine complete all as specified and directed. Note : (i) Works are to be carried out as and where required. (ii) All T&P item/Scap folding as required at site will be arranged by the contractor at no extra cost.
M&L for replacement of U/S Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating concealed type
M&L for taking out/ collected empty Fire Extinguisers of any type and capacity from various locations send to authorized distributor for refilling and re-fixing the same in proper position and location as per the requirement of the location and type of fire extinguisher in and including transfortation complete all as specified and as directed.
Refilling of fire extinguishers with ABC dry chemical powder and pressurization of fire extinguisher with fresh/sufficient quantity/quality, ABC Dry chemical powder as per IS: 14609:1999 and shall contain 90% Mono Ammonium Phosphate and pressurized with Nitrogen Gas in and including painting the cylinder, labeling/marking with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities, a dry chemical Hydraulic Pressure testing should be as per IS-2190-2010 and test certificate shall be submitted and shall be valid for further three years complete all as directed of following capacity cylinders: Note: Any fire extinguiser cylinder will be failing in hydrolic test will be return in AGE E/M Cab Sectt yard and nething extra will be paid for its to the contractor.
10 Kg ABC Powder type Fire Extinguisers
5 Kg ABC Powder type Fire Extinguisers
4 Kg ABC Powder type Fire Extinguisers
Refilling of fire extinguishers with Carbon dioxide (CO2) and pressurization of fire extinguisher with fresh/sufficient quantity/quality, Carbon dioxide shall be as per IS: 15222:2002 with minimum gas purity shall be 99.5 % in and including painting the cylinder, labeling/marking with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities, Carbon dioxide fire extinguishers shall be tested as per IS: 5844-1970 and test pressure shall be 250 kg/ cm2 (as per the IS 2190:2010 ) and test certificate shall be submitted and shall be valid for further five years complete all as directed of following capacity cylinders: Note: Any fire extinguiser cylinder will be failing in hydrolic test will be return in RRC Ghitorni yard and nothing extra will be paid for its to the contractor.
9 Kg Carbon dioxide (CO2) type Fire Extinguisers
6.8 Kg Carbon dioxide (CO2) type Fire Extinguisers
3.2 Kg Carbon dioxide (CO2) type Fire Extinguisers
d) 2 Kg Carbon dioxide (CO2) type Fire Extinguisers
Supplying and fixing and in replacement of Carbon-di-Oxide (CO2) type portable fire extinguishers wall mounted type, ISI marked controllable discharge mechanism conforming to IS: 2878 of following capacity in replacement of unfit extinguishers complete with EPDM Rubber hose pipe, discharge valve wheel type, horn, locking arrangement complete all as specified and directed. Make :- Cease Fire, Minimax
6.8 Kg Carbon dioxide (CO2) type Fire Extinguisers
6 Kg Carbon dioxide (CO2) type Fire Extinguisers
5 Kg Carbon dioxide (CO2) type Fire Extinguisers
4.5 Kg Carbon dioxide (CO2) type Fire Extinguisers
4 Kg Carbon dioxide (CO2) type Fire Extinguisers
3.2 Kg Carbon dioxide (CO2) type Fire Extinguisers
2 Kg Carbon dioxide (CO2) type Fire Extinguisers
Supplying and fixing in replacement of ABC (MAP 90%) Powder type portable fire extinguishers (Stored pressure) ISI marked conforming to IS: 15683: 2006 capacity 4 kg complete with squeeze grip release valve, Magnetic pressure gauge, crack proof EPDM rubber hose pipe and safety clip complete all as specified and directed.
Supply & fixing in replacement of U/S discharge valve wheel type with working pressure 158 Kg/cm² confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 3.2 Kg
Supply & fixing in replacement of U/S discharge valve wheel type with working pressure 158 Kg/cm² confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg and 2 Kg
Supply & fixing in replacement of U/S discharge hose made out of wire braided rubber of ID 10mm and 1 mtr long, confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg and 2 Kg
Supply & fixing in replacement of U/S discharge horn made out of figer glass/pholyethylene, non- conductor of electricity with suitable handle, confirming to IS: 3224 suitable for CO2 type fire extinguishers of capacity 4.5 Kg and 2 Kg
Supply & fixing in replacement of U/S taflon/nylon washer with OD-19mm, ID- 9mm and thichness 3mm
Supply & fixing in replacement of U/S squeeze grip type valve, heavy duty with MS control handle and ss lock/pull pin with chain confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 10 Kg, 5 Kg and 4 Kg
Supply & fixing in replacement of U/S discharge wire braided rubber hose with brass shut off nozzle, length of the flexiblehose not less than 400mm, confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 10 Kg, 5 Kg and 4 Kg
Supply & fixing in replacement of U/S analog type spring brass fire extinguisher pressure gauge, 1" dial suitable for measuring 0 to 50 bar duly calibrate by standard method confirming to IS: 15683 (2006) suitable for ABC type fire extinguishers of capacity 10 Kg, 5 Kg and 4 Kg
M&L for tacking down wall mounted mannual brass fire bell and dismantling carefully all connected parts, chrome polished, gressing after proper cleaning of all matel parts and replaced old warnout pull rope with 1" dia hand- braided red rope, re-assemble and hannging on wall bracket in and including painting of wall bracked with two coats of synthetic enamel paint of approved colour and marking on 'FIRE' complete all as specified and as directed.
M & L in replacement of fire fighting stand post made out of 40 mm GI pipe of size 1.5mtr x 1.0mtr and 1.0 mtr high above the ground level incl cutting, welding and painting in frame and plinth protection of 0.6x0.6x0.3 mtr with hanging hooks 4 for hanging of sand buckets/4 fire extinguiser incl painting with red/post office red colour Complete as directed.
M & L for fire bucket made out of 20 SWG GI sheet 10.0 Ltr capacity incl painting with red colour enamel paint. Complete
M & L in replacement of fire beater with bamboo 10’ long (02 Nos) incl painting with red coloured complete all as specified.
M & L in replacement of fire Hook 10’ long (02 Nos) incl painting with red coloured all as specified.
Cleaning of underground/semi underground sump by taking out all sludge, silt from bottom and cleaning all inside walls with wire brush and brooming the walls and top ceiling/roof including washing the walls with fresh water mixed with bleaching powder and draining out complete sludge, silt etc from bottom of the sump and applying one coat of lime wash for the UG sump of capacity upto 25,000 gallons complete all as directed
M&L for servicing of diesel engine generator (Make-Kirloskar) direct coupling with horizontal mounted multi stage centrifugal pump (fire fighting pump capacity 75 HP Diesel engine type - RB66TO) as per prescribed in repair servicing and maintenance by OEM/authorised dealer cleaning and servicing of fuel supply assembly coolent assembly, AVR unit, control panel incl replacement of minor spare parts viz air filter, oil filter, fuel filter, battery terminals complete including servicing of CI impeller horizantal split casing pump with replacement of old bearing set gland packing lubricating all moveable parts all as specified and directed by Engr-in-Charge. (Note: The contractor will attend breakdown imideately incase of generator gets off road or any other fault occured.
M&L painting of pump, motor complete set including base plate, of capacity 75 HP motor with two coat of synthetic enamel paint after preparing surface all as directed by Engineer-in-Charge.
Disconnecting of electric connection and taking out pump motor from 60 HP 3 phase 415 volt pumpset, transportating the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable gause/size with super enamelled copper wire, replacing insulation paper of class F and fire poor sleeves, varnishing complete, oiling, greasing, replacing old rear/front bearing with new and reassembling complete motor including testing at site all as directed.
All as per item No-42.00 here-in-before but for motor pump set up to 7.5 HP.
All as per item No 42.00 here-in-before but for motor pump set up to 15 HP motor pump set.
Disconnecting of electric connection and taking out pump motor from 75 HP 3 phase 415 volt pumpset, transportating the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable gause/size with super enamelled copper wire, replacing insulation paper of class F and fire poor sleeves, varnishing complete, oiling, greasing, replacing old rear/front bearing with new and reassembling complete motor including testing at site all as directed.
All as per item No 43.00 here-in-before but for motor pump set up to 5.5 HP motor pump set
S&F in replacement of fully automatic star delta starter in sheet-steel enclouser type MN with single phase protection suitable for motor rating 5.5 KW 3 phase 415 volt 50 Hz relay range 12-15 Amps Make-L&T or equivelent.
Supply only front bearing for 60 HP motor for bearing suitable/existing sample all as directed by Engineer-in-Charge
Supply only front bearing for 75 HP motor for bearing suitable/existing sample all as directed by Engineer-in-Charge
Supply only rear end bearing for 75 HP motor for bearing suitable/existing sample all as directed by Engineer-in-Charge (Make-SKF or equivelent).
S&F in repair tyre coupling suitable for 75 HP motor set with existing alignment all as specified directed.
S&F in repair 3 pole power contactor 2 NO+2NC ML 6 three phase AC 440 volts 50 Hz, of 110 Amps AC-1, 110 Amps AC-3 (Make-L&T Cat part No SS90921 or equivalent rating on other make)
S&F in repair 3 pole power contactor MNX 80 AC-1 rating 80A and AC 3 rating 100A three phase AC 440 volts 50 HZ (Make-L&T cat part No-CS97077 or equivalent rating on other make)
S&F in repair 3 pole power contactor MNX 35 AC-1 rating 32A and AC3 rating 45 A three phase AC 440 volts 50Hz (Make-L&T Cat part No-CS94111DOOO or equivalent rating on other make)
S&F in repair 3 pole power contactor MNX 25 AC-1 rating 25A and AC3 rating 45A three phase AC 440 volts 50Hz (Make-L&T Cat Part No-CS14110 or equivalent rating on other make)
S&F in repair ST timer 100 range 3-30 Sec coil voltage 160-500 Volts AC (Make-L&T Cat Part No-ST803280000 or equivalent rating on other make)
S&F in repair thermal overhead relay MN-5 with start and off/reset of Amps range Relay 66-110A 415V AC class Make-L&T Cat Part No-SS94137 or Equivalent in C&S
S&F in replacement of MCCB 250 Amp breaking capacity 36 KA, 4 pole 415 volts 50 Hz, Make-Legrand/L&T or equivalent
S&F in replacement of MCCB 100 Amp breaking capacity 16 KA, 3 pole and neutral, 415 volts 50 Hz, Make-Legrand/L&T or equivalent
S&F in repair rubber gland packing suitable for sluice valve 200/150mm dia
S&F in repair rubber gland packing suitable for sluice valve 100/80mm dia
Repair of NRV of size 200/150mm flanged type by opening and cleaning inner plate spendle replacement of 6mm thick rubber gasket, MS nuts, bolts and washers after repairing refixing the same in existing position all as specified and as directed.
M&L for repair of leakage fire fighting distribution pipe line 80mm bore to 200mm bore by cutting of existing line finding leakage and repair with suitable jointing material complete including necessary excavation, returning filling, removing etc in any type of soil all as directed by Engineer-in-Charge. Note: T&P and fittings if any required shall be inclusive in quoted rate.
M&L for repair/servicing of LT indoor panel board of any size/type, cleaning with compressed air, checking all internal components viz wiring, controls replacement of old lugs, nut bolts, thimble for proper connection to main earth lead, glands to be provided /replaced as required at cable entires, fixing of front & back side broken door hinges after repair and servicing spray painting with powder coated paint with weather protection supper enamelled paint of existing colour in outer/inner side of panel aftercleaning and preparing surface complete all as directed (Note : Any other Unsv spares if any required for replacement , same will be measured from relevent item of schedule)
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No 3" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed.
Supply, fixing and testing in replacement of non return valve flange type of PN 1.6 rating, ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 complete all as specified and directed of following sizes:-
All as per item srl No. 62.00 here-in-before but 150 mm dia
All as per item srl No. 62.00 here-in-before but 100 mm dia
All as per item srl No. 62.00 here-in-before but 80 mm dia
Making insertion under road without cutting of road for laying of MS/GI pipe line upto 150mm bore by using mechanically operated machine.
Repair of sluice valve in position double flanged case iron for repair, replacement of unserviceable components such as of bonnet, gland packing, seat, disk gasket nut bolts and spindal with nut after repair, resurfacing refixing the valve in position and testing all specified and as directed of following sized:-
All as per item srl No. 64.00 here-in-before but 200 mm dia
All as per item srl No. 64.00 here-in-before but 150 mm dia
All as per item srl No. 64.00 here-in-before but 100 mm dia
All as per item srl No. 64.00 here-in-before but 80 mm dia
M&L for servicing of diesel engine generator (Make-Kirloskar) direct coupling with horizontal mounted multi stage centrifugal pump (fire fighting pump capacity 75 HP Model- DSM 100/36) as per prescribed in repair servicing and maintanance by OEM / Authorised dealer cleaning and servicing of fuel supply assembly coolent assembly, AVR unit, control panel, incl replacement of minor spare parts viz air filter, oil filter, fuel filter, battery terminals complete including servicing of CI impeller horizontal split casing pump with replacement of old bearing set gland packing lubricating all moveable parts all as specified and as directed. NOTE: The contractor will attend breakdown immediately in case of generator gets off road or any other fault occured.
Supply & fixing in replacement of broken glass window size not less than 180cm x 200cm x 4 mm thick in yard fire hydrant box inscribed with word 'FIRE' with red post office colour synthetic enamel paint as per existing pattern complete all as specified and as directed.
M&L repair/servicing of air vessel (size 300mm dia 2m height) by disconnecting water pipe connection, opening air valve cleaning of inner/outer surface for proper functioning after repairing and servicing testing and painting with synthetic enamel paint of post office red coloured over two coat of red oxide primer on outside complete all as specified and as directed.
M&L for painting of MS fire hydrant box Indoor/outdoor type of internal size not less than 97x105x60cm after throughly cleaning/scraping of old paints, preparation of surfaces with emery paper as per existing colour code duly painted with two coat of red post office colour synthetic enamel paint in surface over a coat of red oxide primer complete all as specified and as directed.
Painting of any type of valves of (sluice valve / NRV) sizes 80mm to 200mm on existing position with cleaning/scrapping of old paints, preparation of surfaces as per existing colour code duly painted with two coat of red post office colour synthetic enamel paint in surface over a coat of red oxide primer complete all as specified and as directed.
S&F in replacement of fire alarm sounders / sirens electronic type horizontal two stage continous norma operation for atleast 50 minutes with sound level 65 Db to 120 Db measured at 1.5m with sound output variation of +5 Db 500m range complete all as specified and as directed.
S&F in replacement of dial type pressure gauge 4" dial 0-14 Kgs rating including necessary fittings complete all as specified and as directed.
M&L for cleaning of fire pipe line duct/trench size not less than 1.50 m width and 50 cm dipth after removing of MS Cover by removing/taking up dirty water alongwith sludge including cleaning of valve chamber/pit of any size by scrubbing of the internal surfaces and refixing of MS cover complete all as specified and as directed. NOTE: Earth work if required at site the same will be measured under relevant item of Sch 'A'.
M&L repair and servicing of 75 HP pump set by dismantling at site or transport to workshop as required by opening the pump / replacement unservicable both side bearing and bushes, shaft seal assembly and wornout nuts and bolts gaskets, machining of shafts, over hauling and greasing of pump and re-assembling complete with testing motor at site complete all as specified and as directed.
M&L for taking out electrical driven motor suitable for 75 HP pump set after disconnecting all electrical and water connection and deassembling form base and uncoupling motor shaft copling and taking and transport to workshop & opening carefully and servicing complete with replacing of bushes/bearings, motor crank set, shaft seal assembly, rubber gasket, nut-bolt & washers painting internally with synthetic enamel paint and re-fixing it in original position and making out all electrical and water connection after necessary preparation including testing and commissioning complete all as specified and as directed.
M&L refilling fire trace tube auto operating portable extinguisher of 1 Kg capacity with nitrogen gas (NOVEC-1230 HFC 227 ea) and pressuriztion of fire extinguisher with fresh/sufficient/quality nitrogen gas purity shall be 99.5% including labeling/marking with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities, fire extinguishers shall be tested as per IS:5844-1970 and test pressure shall be 250 Kg/Cm2 (as per IS: 2190:2010) and test certificate shall be submitted and shall be valid for furher three years complete all as specified and as directed.
All as per item srl No. 64.00 here-in-before but portable extinguisher of 2 Kg capacity.
Surjit and Sons (BID ID -3186276)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .