Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAdmitted-Finance | ₹42.5 L | L1 | Admitted-Finance |
| 2 | L2₹45.4 LAdmitted-Finance | ₹45.4 L | L2 | Admitted-Finance |
| 3 | L3₹62.9 LAdmitted-Finance | ₹62.9 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Kgn Construction And Distribution L1 | AMIT ENGINEERING CORPORATION L2 | NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER L3 |
|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | ||||||
| 1.01 | 10 MVA -33/11kV Power Transformer | 2 | Nos. | - | - | - |
| 2.00 | Cost of Power Transformer Plinth with Rail Piece 90 LBS -4 mtr long 2 nos as per specification (All The material shall be provided by the contractor) | 2 | Nos. | - | - | - |
| 3.00 | MS Round Bar 32 mm | 5,000 | Kg | - | - | - |
| 4.00 | Earthing of substation complete by round bar 32 mm dia complete as per specification and connection of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM) | 1 | job | - | - | - |
| 5.00 | 33KV Line Isolator | 1 | Nos. | - | - | - |
| 6.00 | 33KV Bus Isolator | 4 | Nos. | - | - | - |
| 7.00 | 33 KV VCB (motorised) with structure | 3 | Nos. | - | - | - |
| 8.00 | 33 kV 1 Ph CT 200/100/1 Amp. | 6 | Nos. | - | - | - |
| 9.00 | 33 kV 1 Ph CT 400/200/1 Amp. | 3 | Nos. | - | - | - |
Tender Value
₹2.5 Cr
EMD Value
₹2.5 L
Closing Date
9 Oct 2019, 5:00 pmClosed
SE EUCC V LESA LUCKNOW
Lesa Bhawan residency Lucknow
Construction of 33/11 kV 2x10 MVA Sub station 1 at SGPGI Campus
2019_MVVNL_386222_1
14/EUCC V/2019-20
Open Tender
Electrical Works
180 days
SGPGI Campus
As Per Tender Document
2 documents required · 2 mandatory
₹5,900
A/c. No. 00500200000456 IFSC CODE BARBOHAZARA BOB
₹2.5 L
15 Jan 2020
28 Sept 2019
10 Oct 2019
28 Sept 2019
9 Oct 2019
28 Sept 2019
Amount
Laying and Jointing PVC Pipe. Heading
10 MVA -33/11kV Power Transformer
Cost of Power Transformer Plinth with Rail Piece 90 LBS -4 mtr long 2 nos as per specification (All The material shall be provided by the contractor)
MS Round Bar 32 mm
Earthing of substation complete by round bar 32 mm dia complete as per specification and connection of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
33KV Line Isolator
33KV Bus Isolator
33 KV VCB (motorised) with structure
33 kV 1 Ph CT 200/100/1 Amp.
33 kV 1 Ph CT 400/200/1 Amp.
33 KV PT 33KV/110 V
33KV Lightning Arrestor 400 Amp
33kV Control panel for double T/F with differential relay
33kV Control panel for single feeder without differential relay
Structure for 33 KV Line/Bus Isolator as per specification(including Plinth & foundation) as per specification
Structure for 33KV Lightning Arrester (3 nos.) with Plinth & foundation
33 KV VCB plinth & foundation (2x2x1mtr.) as per specification
Structure 33 kV Single Phase CT (3 Nos.) with Plinth & foundation
33 KV bus bar gantry complete with structure
Cable Stand structure with foundation
ACSR Panther Conductor
Jumpering of complete line and transformer bay with ACSR Panther conductor by the help of PG clamp and connectors (all Material shall arranged by contractor except ACSR panther conductor)
Structure for Transformer Neutral Stand With Foundation
11 KV VCB Switchgears with Incoming CTR 600/300/5A, 350MVA SCADA Compatible
11 KV VCB Switchgear outgoing 200/100/5A,350MVA, SCADA compatible .
11 KV Bus Coupler 350 MVA SCADA Compatible
24 Volt battery and battery charger with cabinet complete
RCC Cable trench 850x800x150 mm with cover as per drawing
Control cable trench 300x300 mm with cover
Heat Shrinkable jointing kit suitable for 11KV XLPE 3x300 Sq.mm. cable size (Outdoor termination kit)
Heat Shirnkable jointing kit suitable for 11KV XLPE 3x300 Sq.mm. cable size (Indoor termination kit)
11KV/0.433 KV, 3 Phase, 63 KVA Transformer (BEE standard, 3 star rating self protected type), Al. wound
Pipe Boring type earthing minimum 40 mtr deep from ground level up to water level with B class GI Ppe 2" dia.connection of equipment with earhting included in the Job as per specification/Norms
11 KV 3 Core Al. XLPE Cable 3x300mm sq.
Control cable 6x2.5 mm sq.
Control cable 4x2.5 mm sq.
Control cable 2x2.5 mm sq.
11 KV 3x70mm2 XLPE cable
11 KV 3x70mm2 J/k outdoor
11 KV 3x70mm2 J/k indoor
LT cable 3.5x70mm2
Laying of 11 KV 3x300 sq mm XLPE cable in cable trench
Laying of 11 KV 3x70 sq mm XLPE cable in cable trench
Filling of switchyard area by gravels of 20-40 mm size with 120 mm thickness
(Station T/F) Plinth with RCC Top 1.5x1.5x1.2 Mtr.
Laying of interlocking tiless in switchyard and other required place
Switchyard Fencing with toewall including switchyard gate (as per Specification) with tenesh type wiremess 10SWG
Outdoor switch yard & approach road Lighting
Painting of Structures in S/S (All The material shall be provided by the contractor )
T & P of Sub-Station & Switchgears including chair table and primary tools etc (As per Specification)
4.5 Kg. CO2 fire extinguisher, portable type
5 kg. Dry chemical powder fire extinguisher, portable type
Fire buckets (4 nos.) with stand filled with dry sand
Rubber matting 20 sq. mm. thick size (1 X 2 mtr.)
S/S name board (SMC) with stand & single line digarm of s/s
Protection Board complete
Construction of Fire wall,RCC framed with fire bricks in between transformers (4.5x0.345x4.00 ) Mtr
LT Distribution panel for S/S with on 100 Amp MCCB and 2 nos outgoing MCB 32Amp, 4nos 16 amp MCB's as per specification
Hoisting of 11KV 3x300 sq mm XLPE cable in panel/cable stand or on outdoor structure/equipment with required clamp nut & bolt and dressing of cable as per norms.
Hoisting of 11KV 3x70 sq mm XLPE cable in panel/cable stand or on outdoor structure/equipment with required clamp, nut&/bolt and dressing of cable as per norms.
Earthing of substation complete as per specification (Indoor earthing)
Laying of LT cable 3.5x70 sq mm in constructed trench
Connection of LT 3.5x70 sq mm LT XLPE cable with suitabe size of Outdoor/indoor with 63 KVA Transformer and LT distribution Panel
STP 11 M long
Top channel 100x50mm
MS angle 65x65x6mm
M S Earthing Rod 20x2500 mm
11KV pin insulator
11KV Pin with Nut
Barbed wire
Danger Board with clamp for 11 KV
Number Plates with nuts & Bolts
Stone pad 300x300x75 mm
D.O. fuse Set
Concreating of pole
MS Nut & Bolt
Clamp with Nut & Bolt
TPMO Set
11 KV Lightening Arrestor
Earth wire clamp with Nut & Bolts
11 KV Work
11 KV 3 Core Al. XLPE Insulated Cable 3x185 mm sq.
11 KV 3x185 sq mm Indoor Jointing Kits
Laying of 11 KV XLPE cable 3x185 sq mm D/C by digging of trench 900 mm, deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling of cable also include in this work (All The material shall be provided by the contractor except 11 KV XLPE cable)
Hoisting of 11KV cable in panel/cable stand/Double Pole or on outdoor structure/equipment with required clamp, nut & bolt and dressing of cable as per norms.
Laying of Single 11 KV 3x185 sq mm XLPE cable in constructed trench
Laying of Single 11 KV 3x185 sq mm XLPE cable in MS pipe 125mm dia (All The material shall be provided by the contractor except 11 KV XLPE cable)
Laying of Single 11 KV 3x185 sq mm XLPE cable in HDPE pipe 125/150mm dia (All The material shall be provided by the contractor except 11 KV XLPE cable)
33 KV Work
33KV 3x300 mm2 XLPE cable
Heat Shrinkable jointing kit for 33 KV 3x300 Sq. mm. XLPE outdoor
Heat Shrinkable Cable jointing kit straight through for 33 KV 3x300 Sq. mm. XLPE Cable
Laying of 33 KV 3x300 sq mm XLPE Double cable by digging of trench 1100 mm, deep, 750 mm wide its boxing with brick,sand,stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. The ferruling/ tagging of cable also include in this work (The contractor shall provide all the required material except 33 KV XLPE cable)
Laying of 33 KV 3x300 sq mm XLPE single cable by in HDPE Pipe 160 mm dia digging of cable trench 600 mm wide and 1100 mm deep as ISS The ferruling/ tagging of cable also include in this work (The contractor shall provide all the required material except 33 KV XLPE cable)
Laying of 33 KV 3x300 sq mm XLPE single cable by in Hume Pipe 200 mm dia digging of cable trench 600 mm wide and 1100 mm deep as ISS The ferruling/ tagging of cable also include in this work (The contractor shall provide all the required material except 33 KV XLPE cable)
Laying of 33 KV 3x300 sq mm XLPE Single cable in constructed trench The ferruling of cable also include in this work (The contractor shall provide all the required material except 33 KV XLPE cable)
Hoisting of 33 KV XLPE cable on cable stand/existing structure with prooper dresssing of cablle as per Norms
Dismentaling of 2 no. 132/11 KV, 20 MVA T/F and carriage from SGPGI Campus to store
AMIT ENGINEERING CORPORATION
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
doc.pdf
Tender Documents • 0.40 MB
BOQ_558299.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid