| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.9 LAccepted-AOC PLOT NO 46 SUGANDHA VIHAR NEAR NEW ERA PROGRASSIVE SCHOOL RAMPUR DIST KORBA 495677 | KORBA | CHHATTISGARH | 495677 | ₹9.9 L | L-1 | Accepted-AOC Accepted as L-1 |
| 2 | L-2₹12.3 LRejected-Finance AT BENIDIH PO GARSARA PS PALAJORI DIST DEOGHAR JHARKHAND | ₹12.3 L | L-2 | Rejected-Finance Rejected as L-2 |
| 3 | Rejected-Technical BEHIND GAYATRI MANDIR WARD NO 12 BIRSINGHPUR PALI MADHYA PRADESH 484551 | BIRSINGHPUR PALI | UMARIA | MADHYA PRADESH | 484551 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | Pioneer Enterprises L1 | ROY CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00Testing and Calibration of different Electrical equipments related to HT Installation at 33KV sub-station, colony lighting transformers and IWSS of Regional Workshop and Testing and Calibration of different Electrical equipment related to HT installation installed at Surface sub-station (OCB, VCB, Transformers, Protective Relays, CT etc.) of Amlai OCM of Sohagpur Area, SECL | |||||
| 1.01 | Part-A Testing and Calibration of different Electrical equipments related to HT Installation at 33KV sub-station, colony lighting transformers and IWSS of Sohagpur Area, SECL
Testing and Calibration of protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc. | 13 | Nos | 1,500 ₹19,500 | 2,000 ₹26,000 |
| 1.02 | Testing and Calibration of 33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines | 40 | Nos | 5,000 ₹2 L | 6,000 ₹2.4 L |
| 1.03 | Testing of VCB, OCB, ACB (interlocking arrangement indication system/ operating mechanism etc. as per norms) | 22 | Nos | 6,000 ₹1.3 L | 6,000 ₹1.3 L |
| 2.01 | Part-B Testing and Calibration of different Electrical equipment related to HT installation installed at Surface sub-station (OCB, VCB, Transformers, Protective Relays, CT etc.) of Amlai OCM of Sohagpur Area, SECL
Testing and Calibration of protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc. | 71 | Nos | 1,500 ₹1.1 L | 1,800 ₹1.3 L |
| 2.02 | Testing and Calibration of33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines) | 12 | Nos | 5,000 ₹60,000 | 7,000 ₹84,000 |
| 2.03 | Testing of Oil Circuit Breakers (interlocking arrangement indication system/ operating mechanism etc. as per norms) | 17 | Nos | 6,000 ₹1.0 L | 6,000 ₹1.0 L |
| 2.04 | IR/High Voltage Test of Cables, Testing & Calibration of all other protective/ measuring equipment (Meggers, Lux meter, High voltage detectors, multimeters etc.) in mine & surface. Note: Work also includes preparation of Single Line Diagram, Mine Plan, Test Reports etc. | 1 | Set | 30,000 ₹30,000 | 4,000 ₹4,000 |
| 2.05 | Periodical primary injection test of 33 KV Current Transformer with control circuit for protection and metering to ensure the healthy condition of 33KV/3.3/6.6 KV substation under Amlai OCM. Note;- Above job include hiring charges of testing equipments and tools required for testing variac (0-280V) 28 Amp., Ammeter(0.5-10 A) specific measuring instruments,tongue testers, Avometer, Megger, power cable lead 2000 Amps.marking clothes, CRC, Emry paper etc along with transportation charge of testing equipments and other tools etc. as required. | 12 | Set | 5,000 ₹60,000 | 6,000 ₹72,000 |
| 2.06 | Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Interfacial tension at 27 degree celsius | 3 | Nos | 2,485 ₹7,455 | 10,000 ₹30,000 |
Tender Value
₹14.9 L
EMD Value
₹18,600
Closing Date
20 Nov 2025, 5:00 pmClosed
Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9424141331
Testing and Calibration of different Electrical equipments related to HT Installation at 33KV sub station colony lighting transformers and IWSS of Regional Workshop and Testing and Calibration of different Electrical equipment related to HT installa
2025_SECL_346684_1
SECL/SGP/EnM/eT/25-26/356 Date 03.11.2025
Open Tender
Electrical and Maintenance Works
65 days
Regional Workshop and Amlai OCM
As per NIT and Tender documents
5 documents required · 5 mandatory
₹18,600
29 Apr 2026
5 Nov 2025
22 Nov 2025
5 Nov 2025
20 Nov 2025
6 Nov 2025
5 Nov 2025 - 13 Nov 2025
Amount
Testing and Calibration of different Electrical equipments related to HT Installation at 33KV sub-station, colony lighting transformers and IWSS of Regional Workshop and Testing and Calibration of different Electrical equipment related to HT installation installed at Surface sub-station (OCB, VCB, Transformers, Protective Relays, CT etc.) of Amlai OCM of Sohagpur Area, SECL
Part-A Testing and Calibration of different Electrical equipments related to HT Installation at 33KV sub-station, colony lighting transformers and IWSS of Sohagpur Area, SECL Testing and Calibration of protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc.
Testing and Calibration of 33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines
Testing of VCB, OCB, ACB (interlocking arrangement indication system/ operating mechanism etc. as per norms)
Part-B Testing and Calibration of different Electrical equipment related to HT installation installed at Surface sub-station (OCB, VCB, Transformers, Protective Relays, CT etc.) of Amlai OCM of Sohagpur Area, SECL Testing and Calibration of protective Relays (IDMT/overload Relay, ELR, No Volt Relay/Master Trip Relay, WTI, OTI, Buchholz Relay etc.
Testing and Calibration of33KV/3.3KV/550V/440V Transformers (Ratio Test, Magnetic Balance Test, Vector Group Test, IR/PI Test, all field test of transformer as per applicable guidelines)
Testing of Oil Circuit Breakers (interlocking arrangement indication system/ operating mechanism etc. as per norms)
IR/High Voltage Test of Cables, Testing & Calibration of all other protective/ measuring equipment (Meggers, Lux meter, High voltage detectors, multimeters etc.) in mine & surface. Note: Work also includes preparation of Single Line Diagram, Mine Plan, Test Reports etc.
Periodical primary injection test of 33 KV Current Transformer with control circuit for protection and metering to ensure the healthy condition of 33KV/3.3/6.6 KV substation under Amlai OCM. Note;- Above job include hiring charges of testing equipments and tools required for testing variac (0-280V) 28 Amp., Ammeter(0.5-10 A) specific measuring instruments,tongue testers, Avometer, Megger, power cable lead 2000 Amps.marking clothes, CRC, Emry paper etc along with transportation charge of testing equipments and other tools etc. as required.
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Interfacial tension at 27 degree celsius
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Flash point
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Neutralization value (Total acidity)
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Dielectric strength (BDV)
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Die electric dissipation factor (Tan Delta)
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Specific Resistance (Resistivity)
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Water content
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Sediment and sludge
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Dissolved gas analysis
Testing of transformer oil of 03 nos. power transformer 33kv/3.3/6.6, 2 MVA /4 MVA /7 MVA installed at Amlai substation - Furan compound analysis
Total impact of GST for the purpose of CTC
ROY CONSTRUCTIONS (BID ID -1197818)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.13 MB
Tendernotice_2.pdf
PDF • 1.89 MB
Tendernotice_3.pdf
PDF • 0.57 MB
BOQ_359379.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid