| 1 | L1₹42.8 LAccepted-AOC 84 ARYA NAGAR SARDHANA ROAD KANKER KHERA MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Accepted due to being L1 | |
| 2 | L2₹43.3 L+₹54,404.15 (1.27%)Rejected-Finance 00 BHADAR TIKARMAFI BAZAR SULTANPUR UTTAR PRADESH 227413 | AMETHI | UTTAR PRADESH | 227413 | L2 | Rejected-Finance Rejected due to being L1 | |
| 3 | L3₹43.7 L+₹89,076.30 (2.08%)Rejected-Finance 10 RAJAN KUNJ ROORKEE ROAD MEERUT UP PIN 250110 | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-Finance Rejected due to being L1 | |
| 4 | L4₹45.4 L+₹2.6 L (6.16%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L4 | Rejected-Finance Rejected due to being L1 |
| Sl No | Description | Qty | Unit | AR Enterprises L1 | SHAKTI CONSTRUCTION CO L3 | M/s Dev Enterprises L2 | shahji contractors L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. | 120 | Sqm | 30 ₹3,600 | 100 ₹12,000 | 25 ₹3,000 Lowest | 35 ₹4,200 |
| 2.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed. | 15.55 | Cum | 300 ₹4,665 | 100 ₹1,555 Lowest | 180 ₹2,799 | 250 ₹3,887.5 |
| 3.00 | Returning filling in,including spreading,levelling,watering and well ramming in layers not exceeding 25cm in soil complete all as specified and directed. | 6.22 | Cum | 50 ₹311 | 100 ₹622 | 50 ₹311 | 35 ₹217.7 Lowest |
| 4.00 | Removing excavated soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 9.33 | Cum | 50 ₹466.5 | 100 ₹933 | 50 ₹466.5 | 35 ₹326.55 Lowest |
| 5.00 | M & L for broken bricks Hardcore of guage not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. | 10.46 | Cum | 1,000 ₹10,460 Lowest | 1,500 ₹15,690 | 1,200 ₹12,552 | 2,000 ₹20,920 |
| 6.00 | M&L for PCC 1:4:8 type D-2 (40 mm gradded) as in foundation filling and mass concrete complete all as specified and directed. | 6.97 | Cum | 5,500 ₹38,335 | 5,500 ₹38,335 | 3,500 ₹24,395 Lowest | 4,000 ₹27,880 |
| 7.00 | M&L Brickwork with fly ash bricks old size straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed. | 72.08 | Cum | 6,800 ₹4,90,144 | 7,500 ₹5,40,600 | 4,500 ₹3,24,360 Lowest | 4,750 ₹3,42,380 |
| 8.00 | M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. | 267.1 | Sqm | 280 ₹74,788 | 250 ₹66,775 Lowest | 265 ₹70,781.5 | 280 ₹74,788 |
| 9.00 | M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed. | 87.49 | Sqm | 300 ₹26,247 | 250 ₹21,872.5 | 210 ₹18,372.9 Lowest | 220 ₹19,247.8 |
| 10.00 | M&L for rendering 15 mm thick on brick surfaces or surface other than fair face of brick work or on one side of lathing in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. | 267.1 | Sqm | 270 ₹72,117 | 250 ₹66,775 | 200 ₹53,420 | 180 ₹48,078 Lowest |
Tender Value
₹44.0 L
EMD Value
₹88,060
Closing Date
20 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
PROVN OF COVERED ROOM FOR ESTABLISHING A T-72 DRIVING SIMULATOR WITH DIMENSIONS OF 30 FEET LENTH X 25 FEET WIDTH 18 X FEET HEIGHT AND DOOR/SHUTTER SHOULD BE MINIMUM OF 16 FEET HEIGHT X 20 FEET WIDE AT MT AREA OF 9 RAPID ENGR REGT AND SPL REPAIR TO RO
2025_MES_733147_1
GE/MRT/S/8276/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹88,060
Yes
Garrison Engineer (South) Meerut Cantt
22 Dec 2025
29 Sept 2025
27 Oct 2025
29 Sept 2025
20 Oct 2025
13 Oct 2025
6 Oct 2025
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in,including spreading,levelling,watering and well ramming in layers not exceeding 25cm in soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for broken bricks Hardcore of guage not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (40 mm gradded) as in foundation filling and mass concrete complete all as specified and directed.
M&L Brickwork with fly ash bricks old size straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed.
M&L for rendering 15 mm thick on brick surfaces or surface other than fair face of brick work or on one side of lathing in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L PCC (1:4:8) type D-2, 75 mm thick (using 40 mm graded stone agg) as sub base complete all as specified and directed.
M&L 20mm thick Granite (of any type) tiles machine cut, in floor/bedded laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over screed bed 15 mm thick CM 1:3 complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe- 415, Fe 500 or Fe-550 as in steel reinforcement for concrete complete all as specified and directed.
All as per item No 13.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders Complete all as specified and directed.
M&L for RCC M-25 (Design mix) using 20mm grade aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste formwork to sides of concrete foundation, footings, bases of column, rafts, plinth beams and similar work vertical or to batter rough finished surface flat of concrete, With water tight complete all as specified and directed.
Use and waste Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat Complete all as specified and directed.
Use and waste Formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Circular on plan Complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exceeding 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat Complete all as specified and directed.
M&L for formwork to Edges of concrete flats, treads, breaks in floors.concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC band in walls, sloping and similar work for fair finished surfaces. Rough finished surfaces of concrete flat Complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors including stack clamps of 50mm x 3 mm flat iron with bolts & nuts.Complete all as specified and directed.
M&L PVC SWR floor trap, with grating including joining to waste pipe fixed in cement concrete type B-1 (1:2:4) 100 mm dia Complete all as specified and directed.
S&F PVC (SWR) bend 110mm dia radius complete all as specified and directed.
M&L for padding in PCC 1:2:4 type B0 (using 12.5mm graded stone agg) laid to a minimum consolidated thickness 50mm to provide a finished slope 1:30 complete all as specified and directed.
M&L for rendering over roof slab in cement mortar 1:4, 20 mm thick mixed with water proofing compound, complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for applying two coats of oil emulsion (OBD) over a coat of primer on walls including preparation on newly plastered surface. complete all as specified and directed.
Material & labour for preparation of new plastered surfaces of walls etc and applying two coats of cement base paint over a coat of primer complete all as specified & directed.
Applying three coats of white wash on new Ceiling surface including preparation of surface. complete all as specified and directed.
M&L Providing cement concrete 75mm thick type C2 (1:3:6) (40mm grade aggregate) as in Plinth protection finishing cement concrete surface even and smooth without using extra cement. complete all as specified and directed.
M&L for powder coated aluminium door shutters without sash bars, aluminium sections weighing 0.55 Kg/m(min) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading,screws suitable anodised fittings such as, hinges, handles, including anodised aluminium frame with one or more rebates including S&F 5 to 6 mm thick black glass all and aluminium grill fixed to frame complete all as specified and directed.
M&L for powder coated aluminium partition, aluminium sections weighing 0.55 Kg/m(min) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading,screws including anodised aluminium frame with one or more rebates complete all as specified and directed.
S&F 5 to 6 mm thick black glasscomplete all as specified and directed.
Supply and fix false ceiling with 4mm thick E board make white prelaminated, set embossed reinforced designer ceiling board of oceanic texture fixed over and including GI grid frame work of size not more than 600x600 mm having 25mm wide t-section runner made of 0.33mm GI sheet and angle made 0.45mm thick GI sheet suspended with and including 4mm dia GI wire and leveling clips complete all as specified and directed. Note: All exposed surface of grid shall be powdered coated white.
M&L 60 mm thick, interlocking paver block PCC type M-35 with grey cement & pigment, of shape approved by GE, in paths over & including 25 mm thick sand cushioning bed complete all as specified and directed.
M&L 75mm thick, PCC 1:4:8 type D2, (using 40 mm graded stone aggregate) as in as in sub base of flooring complete all as specified and directed.
S&F for 5 mm thick PVC Wall Lining of hollow section consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 0.60 mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing PVC Panel with Single Side Prelam PVC sheet used instead of plain colour sheet thickness of PVC wall PVC Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (20mm gardded aggregate) as in surface channel, drains complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L Cement conc 1:2:4 type B-1 (20mm graded) as in coping, to top of brick /concrete work incl necessary form work complete all as specified and directed.
Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed.
Cutting out cracks to V section to 25 mm depth in existing roofs or terracing, cleaning out, wetting,and painted with shalitex primer and filled with sealing compound , APP membrane complete all as specified and directed
M& L for PCC padding 1:2:4 type B1(using 20 mm graded stone aggregate) average thickness 25mm,finished fair and even without using extra cement on roof surfaces complete all as specified and directed.
M&L Rendering 15 mm thick screed bed on roof surface including flashings and junction of parapets etc, finished even and smooth in cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry complete all as specified and directed.
Material & labour for cleaning of concrete or plastered surfaces of roof and applying priming coat using with bituminous primer @ 0.30kg per Sqm followed evenly by a tack coat @ 1.20 kg per Sqm using 85/25 grade industrial hot blown bitumen , over it laid with 3mm thick APP modified polymeric water proofing membrane minimum weight 3.6 Kg per Sqm reinforced with non-woven polyester fabric (weight not less than 160 Gm per Sqm) unrolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer’s instruction and applying over it a tack coat using 85/25 grade industrial hot blown bitumen bitumen @ 1.20 kg per Sqm and finally finished the top of polymeric water proofing membrane with a coat of bituminous aluminum paint @ 0.20 kg per Sqm as per manufacturer’s instructions, complete all as specified & directed. (including existing water tank on roof disconnected and refixd after cleanig in same position.
Supply only integral water proofing compound complete all as specified and directed.
Taking down cement plaster on RCC chajja,roof slabs and projection on top of chajja etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L Rendering 15 mm thick (average thickness) rendering on RCC chajja, ceiling and projection on top of chajja roof surface including flashings and junction of parapets etc., to be finished even and smooth (without using extra cement) even and fair on in CM (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry complete all as specified and directed.
M&L Preparation of new decorated wall surfaces plastered and applying Two coats of weather proof exterior acrylic emulsion paint over a coat of primer of complete all as specified and directed.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 PVC insulated, unsheathed copper conductor cable in and including PVC surface conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3.0 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One Tube light/bulb/fancy/bell/street light point controlled by one, one way switch 05 / 06 Amps.
All as per item No 55.00 here - in - before but One ceiling fan/ exhaust fan point controlled by one, one way switch 05 / 06 Amps.
All as per item No 55.00 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch.
All as per item No 55.00 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board.
Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply & fixing socket outlet 3 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.
Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed
Supply & fixing of socket outlet 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified and directed.
Supply and fix decorative LED Batten 20 Watt polycarbonate housing integtrated type complete with all accessories and fixing material complete all as specified and directed.
Supply and fixed LED security light fitting 35 watt suitable for 230 volt single phase complete with all accessories complete all as specified and directed.
Supply & fixing of ceiling rose, 3 phase / PVC / polycarbonate isolated body complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm,36 watt, 220 V AC recessed type with highefficiency PMMA diffusersoftglare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt or fixing of 1 No MCCB 4 Pole160Amps 36 KA, 415 volts and 12 Nos MCB's inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed.
M&L Sheet metal enclosure for DB's with IP 43 protection 100 amp rated insulated bus bar, shrouded neutral bar, earth bar, blanking plate, cable ties & circuit identification labels 240 volt SPN 12 way including taking down old unsv DB's complete all as specified and directed.
M&L Sheet metal enclosure for DB's with IP 43 protection 100 amp rated insulated bus bar, shrouded neutral bar, earth bar, blanking plate, cable ties & circuit identification labels 240 volt SPN 4 way including taking down old unsv DB's complete all as specified and directed.
Supply and fix Isolator TPN 415 volt 100 Amps 10 KA, 50 Hz complete all as specified and directed.
Supply and fixing MCB SP, AC, 240 volts of 06 to 40 Amps, B curve, 10 kA, complete all as specified and directed.
Supply & fixing MCB SPN, AC, 240 volts of 63 Amps, B curve, 10 kA, complete all as specified and directed.
Material and labour for sub main wiring with 10 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size10.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all MS conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note:- One meter of conduit along with 2x10 sq mm wire and one 10.0 sq mm earth shall be measured as one unit length.
Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all MS conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note:- One meter of conduit along with 2x6 sq mm wire and one 6.0 sq mm earth shall be measured as one unit length.
Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 4.0 core armoured, PVC sheathed with aluminium conductor heavy duty laid in tranchies, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed
Supply / laying and fixing 40mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft / loose soil and gating out in soft / loose soil complete all as specified and directed.
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed.
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft / loose soil complete all as specified and directed.
Removing surplus excavated materials not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, step type electronic fan regulator 60 watt and ccessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor ( BLDC) complete all as specified and directed.
Supply & fixing industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 32 Amps MCB, single pole, AC, 240 volts complete all as specified and directed.
S&F hi wall split units indoor and outdoor complete with cordless remote control unit and with Cooling and Heating function buit air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 Ton complete all as specified and directed.
S&F automatic voltage stabilizer capacity 4 KVA work efficiently for input voltage variation betwwen 150 to 285 volts, digital display,complete all as specified and directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I . complete all as specified and directed.
M/s Dev Enterprises (BID ID -3463877)
SHAKTI CONSTRUCTION CO (BID ID -3460821)
shahji contractors (BID ID -3464591)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.64 MB
TenderdocumentsBR-EM.pdf
Tender Documents • 2.07 MB
BOQ_820999.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .