Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
27 Jan 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (RSP)
ELECTRICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical License: - Tenderer should have valid 'A' Class Electrical Contractor License issued by electrical inspector of any State Government/Union Territory of India. If 'A' Class Electrical Contractor License has expired, tenderer should submit receipt of renewal of 'A' Class Electrical Contractor License issued by electrical inspector of License issuing authority as mentioned above. At the time of contract agreement, contractor must submit valid 'A' Class Electrical Contractor License issued by electrical inspector of License issuing authority as mentioned above else contract will be terminated without any information to successful tenderer. In case of non-submission of valid 'A' Class Electrical Contractor License / receipt of renewal of electrical contractor license along-with offer, their offer will not be considered VALID.
Similar Nature of work- "The firm should have experience of maintenance (including AMC & CMC)/repair/rehabilitation/manufacture of minimum 500KVA DA Sets. The firm should have repaired/rehabilitated/manufactured at least 50 DA sets of minimum 500KVA capacity OR should have successfully executed maintenance work (including AMC & CMC) of DA sets of minimum 500KVA capacity for minimum 1200 units (calculated as- DA sets x Months) during last five years and should have manpower with competency for working on voltages above 750V."
15 conditions
All the bidders/tenders should ensure that they are GST complaint and their quoted tax structure/rates are as per GST Law. (Please upload certificate of GSTIN registration)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rights Of The Railway To Deal With Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender and no tenderer(s) shall demand any explanation for the cause of rejection of his/their tender nor the Railway to assign reasons for declining to consider or reject any particular tender or tenders.
If the tenderer(s) deliberately gives / give wrong information in his / their tender or creates / create circumstances for the acceptance of his / their tender, the Railway reserves the right to reject such tender at any stage.
Replacement of isolation switch for starting battery in 2200 Power cars @ Rs.136476.44/-, (WB item No. 818/2025-26), Allotted Qty. 130 No. Power Cars
EL-MWS-GKP-2025-26-20~NER
EL-MWS-GKP-2025-26-20
Open
Works - General
24 Months
Gorakhpur, Uttar Pradesh
₹0
₹2.1 L
27 Jan 2026
3 Jan 2026
13 Jan 2026
19 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Above/ 11201733.60 Below/P | ||
| — | 2080.00 | — | — | ||
| Supply, fixing, testing & commissioning of Copper crimping socket for 120 sqmm E- Beam cable for RCF specification No. EDTS-200, Rev-Nil, Corr-2 or Latest, (16 Nos per Cars.) | — | — | — | 2,35,620.86 | |
| — | 5200.00 | — | — | ||
| Supply, fixing, testing & commissioning of polyamide flexible conduit pipe NW29 (OD 34.4 +/-0.2) black in colour with RDSO specification No-RDSO/PE/SPEC/AC/0138-2009 (rev. 1) (40 mtr. Per power car) (Material to be inspected by RITES) | — | — | — | 6,14,942.35 | |
| — | 3900.00 | — | — | ||
| Supply, fixing, testing & commissioning of polyamide flexible conduit pipe NW12 (OD- 15.8 +/- 0.2) black in colour with RDSO specification No-RDSO/PE/SPEC/AC/0138-2009 (rev. 1) (30 mtr. Per power car) | — | — | — | 94,679.85 | |
| — | 5200.00 | — | — | ||
| Supply, fixing, testing & commissioning of copper cable 120 sqmm. Single core strained annealed tin coated E-Beam irradiated cross link polyolefin insulated cable suitable for 1.8/3 KV grade as per RDSO's spec No- ELRS/SPEC/ELC/0019 Rev 4 of Feb 2018 (40 mtr. per power car) (Material to be inspected by RITES) | — | — | — | 53,59,571.79 | |
| — | 520.00 | — | — | ||
| Supply, fixing, testing & commissioning of DIN Type HRC Fuse Link Rated Current 315 Amp. 415V AC 50 Hz and breaking capacity 100 KA conforming to IEC 60269-2, IS 13703 part 2 (04 Nos, per power car.) | — | — | — | 3,51,153.36 | |
| — | 260.00 | — | — | ||
| Supply, fixing, testing & commissioning of Sheet Steel Enclosure suitable for DIN Type HRC Fuse Link, rated current -315 A, conforming to IEC 60947-3, IS/IEC 60947-3 (02 Nos per power car.) (Material to be inspected by RITES) | — | — | — | 41,34,546.52 | |
| — | 3900.00 | — | — | ||
| Supply, fixing, testing & commissioning of E-Beam irradiated thin walled flexible elastomeric cross linked cable size 2.5 sq.mm 750 V Grade conforming to RDSO Spec No. ELRS/SPEC/ELC/0019 (Rev.4) (30 Mtrs per power car.) | — | — | — | 92,233.83 | |
| — | 1040.00 | — | — | ||
| Supply, fixing, testing & commissioning of Copper crimping socket for 2.5 sq.mm cable as per specification no. EDTS 201 Rev.-A AM -23, Corr-2 (08 Nos per power car.) | — | — | — | 3,431.96 | |
| — | 130.00 | — | — | ||
| Labour Charge for modification of manual isolating switch for starting battery in the DA set in power cars as per requirement complete in all respect as per direction of Engineer in- charge at site. | — | — | — | 3,15,553.08 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .