Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.7 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹18.4 L+₹66,292.35 (3.74%)Rejected-Finance V P O JAGANOO TEH DISTT UDHAMPUR J K 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹18.8 L+₹1.1 L (5.98%)Rejected-Finance VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹19.1 L+₹1.4 L (7.70%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹23.1 L
EMD Value
₹46,220
Closing Date
18 Jul 2020, 6:00 pmClosed
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182 121
SPL REPAIR TO ROOF, CEILING, FLOORING, PLASTER AND TILING OF FRESH ISSUE SHED BLDG NO NP-34 OF ASC (COY) UNDER GE (NORTH) UDHAMPUR
2020_MES_350795_1
CWE/U(N)-44/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹46,220
Yes
15 Sept 2020
8 Jun 2020
20 Jul 2020
8 Jun 2020
18 Jul 2020
6 Jul 2020
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 300x450mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
16-18mm thick green marble slabs of width as directed, machine cut, bedded jointed and pointed with grey cement slurry, as in floors laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over & including screed bed or bedding layer 20mm thick in cement mortar (1:3) complete all as specified and as directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
4mm thick Cement fibre board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI suspensions, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge. Make of false ceiling board & GI Grid : Everest/V board or equivalent as specified in PS
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for roof padding, including roof tiles etc complete all as specified and as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed.
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones omplete all as specified..
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
S&F powder coated door air tight of anodised frame made of size 100 mm x 45mm of section thickness -1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick plain glass as in panels shutter rail made of 80mm x45 mm of sheet thickness 1.50 mm (Top and bottom rails and side rail ) single /double leaf side hung type including necessary jointing cleats, anodised aluminium fittings such as aluminium butt hinges 100 mm long 4 nos on each shutter, aluminium anodised tower bolt 200mm long 03 No for each door, aluminium anodised bow handles 150 mm 'D type 02 nos for each shutter, mortice locks 6 lever make harrison one on each door, door shutter mounted on bottom double action floor spring hydrailically regulated made up of 1.25mm thick aluminium alloy sheet foundation box , main body with stainless steel cover, governing mild steel heavy duty and door shutter top mounted on aluminium alloy pivot. -01 No on each shutter, bottom and floor stoppers, Complete all as specified Note : All fitting shall be of ISI marked except cleats) sizes of each door shall be as per site requirement all as directed and specified.
Applying two coats of oil bound distemper over and including a coat of primer including preparation of newly plastered surfaces of wall.
Description all as Srl item No 22 above but removal of existing treatment including preparation of old plastered surfaces of wall.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and as directed by Engr-in-Charge.
Description all as Srl item No 24 above but removal of existing treatment including preparation of old plastered surfaces of wall.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light /fan/ bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 27 above but but one 3/5 pin 5 Amp socket outlet on independent board .
Description all asper item No 27 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 27 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Switch piano type 5 Amps single pole one way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch piano type 15 Amps single pole one way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 5/ 15 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
S&F LED light fittng PLUTO NEO PANEL 2x2 PLR 34 Watt LED environmental friendly, new genaration, aesthetically designed ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for armstrong/Grid ceiling all as specified and as directed by engineer in charge. Make : Havells Cat No PLUTONEO2X2PLR34WLED840S or equivalent makes of SYSKA/CG
LED bulk head luminaire, 9/10 watt surface mounting type extruded aluminium body with diffuser and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells cat Pt No LHEXCFP7PN5W010, 230V or equivalent in performance of makes as specified in particular specifications.
Supply and fixing LED Street Light fitting 40 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating LED (Make of LED shall be CREE/Necia/Osram) including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge. Make :SYSKA cat No. SSK-SLF-BO-40W or Havells Cat part No ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent in performance of makes as specified in particular specifications.
Note for srl item No 35 to 37 : (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Taking down ceiling fan/ exhaust fan/ wall fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc.,complete all as per the directions of Engg-in-Charge.
Hanging/fixing only ceiling fan/ exhaust fan/ wall fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item No-38
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge. Makes: Legrand/ HPL/Indo asian.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 42 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down old unserviceable copper /aluminium,submain wiring any type/size fron existing old surface for further repair/replacement, complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
Re-fixing only,serviceable MCB/DB of any type and capacity with MCB as obtained against item No 45 & 46 complete including minor repair to existing fitting occure while dismentling, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts including providing copper thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Supply, Laying, testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables heavy duty 1100 volts grade stranded aluminium conductor laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 2 core including taking down of old cable, complete all as specified and as directed by Engr-in-Charge. Note : Earth work and other connected work shall be measured & paid seperately.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Cutting of bituminous /PCC road including excavation to a standard depth and width as specified in SSR for laying GI pipe/XLPE cable, retruning filling including removal of surplus soil/debris to a distance not exceeding 50 metre and after returning filling, making good the distrubed ground by providing 30mm thick premix carpeting over 75mm thick WBM over 100 mm thick stone soling or 100mm thick PCC 1:1.5:3 type A-1 (using 20 mm graded crushed stone aggregates) over stone soling to match the exisitng surfaces of road complete all as specified and as directed by Engineer-in-Charge.
HANS RAJ SHARMA
KALSOTRA CONSTRUCTION CO
Alishan Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .