| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.4 L+₹50,688 (10.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.5 L+₹57,888 (11.7%)Rejected-Finance MOHISHILA COLONY ASANSOL 713303 | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical No documents submitted as per letter vide memo no. 443 dt. 12/03/2021 | |
| 5 | Rejected-Technical PO PAHALANPUR PS MADHABDIHI DIST BURDWAN PIN 713427 | HOOGHLY | WEST BENGAL | 713427 | - | Rejected-Technical No documents submitted as per letter vide memo no. 443 dt. 12/03/2021 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
20 Jan 2021, 2:00 pmClosed
Executive Engineer_ PWD_ Kolkata East Division
11A_ MIrza Galib Street_ Kolkata-700087
Supplying and placing of Fire Extinguishers at Alliah University Main Building G_1 Storied within the premises of 21 Haji Md Mohsin Road Kol_16 during the year 2019_20
2021_WBPWD_313583_2
WBPWD/EE/KED/NIT-24/2020-21
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
17 Aug 2021
7 Jan 2021
22 Jan 2021
7 Jan 2021
20 Jan 2021
7 Jan 2021
Amount
Supplying, fitting & fixing of CO2 ALUMINIUM 4.5 Kg. Fire Extinguisher - Vessel used in the manufacturing should be constructed using cold impact extrusion. Diameter of sheel up to 150 mm and mounted on trolley. Sheet metal thickness should not less than 4.00 mm. materials of construction should be (Al Alloy 6061).9.gross weight should be within range of 13.90 to 14.40 kg. Content mass should be within the range of 4.275 to 4.725 Kg. Service pressure and maximum service pressure of extingusher should be 70 bar an 156 bar respectively. discharge time should not less than 12 Secs. Applicable on Class B. C & electrically started fire. Fire rating should be class B. 55 B. Certification:- 1. The current and valid BIS certification IS 15683 needs to be submitted along with offer. 2. The vessel should be PESO approved. 3. The product should be EN PED approved and CE marked. 4. The bidder must have valid PESO licence to refill and store compressed gas cylinder as per gas cylinder rules 2004. 5. The carbon dioxide gas shall conferm to IS 15222 with latest amendement. 6. Discharge valve shall be conform to all the requirement given in IS 3224:2002 or latest version thereof. 7. The CO2 Cylinder shall be conform to all the requirement given in IS 7285:2004. 8. Maximum fire rating as per IS:15683 Class B: 55B needs to be provide for the extinguisher. 9. The firm should be submit the product performance test report from NABL accredited Lab as per IS: 15683. Warranty - 10(Ten) Years.
Supplying, fitting & fixing of Stored Pressure Water mist Portable Fire Extingushers Capacity 6 Liter. (Stainless Steel) for Class A, F & Electrical fire. Stored pressure EN3-7, EN3-8 and EN3-9 tested & certified along with IS marked as per IS : 15683. The body of the extingusher shall be of Stainless steel. The diameter of shell is 175 mm. Sheet metal thickness should not less than 1.5mm. Materials of construction should be (SS304(14301)). Gross weight should be within the range of 10.30 Kg to 10.90 Kg. Content mass should be 5.70 Ltrs. to 6.00Ltrs. Discharge hose should provided and length of flexible section should not be less than 460 mm. Serial no. and date of manufacturing should be embossed on the body of fire extinguisher. Extinguisher should be stored pressure type. Extinguisher must have a tamper proof safety pin to avoid unintended use. minimum discharge time should be 42 seconds. the working pressure should be at least 15 bars. Actual burst pressure should not be less than 150 bars. Bulk range throw should be minimum 2.00 meters. The extinguisher must have a pressure gauge to enable the ckecking of pressure gauge working without dismentalling or opening the cyclinder. The equipment should have a specilized rotor to mix propellant and agent to help in producing fine mist. Extinguisher must be helium leak detection. Tested & test report must be furnished at the time of delivery. As per IS 15683. Fire rating should be class A:3A. As per EN3-7, Fire rating should be class A:13A and Class F:75F. Applicable on A,F and electrically started fire. CERTIFICATION:- The current valid BIS certification IS: 15683:2006 needs to be submitted along with the offer. The firm should submit the product performance test report from NABL accredited Lab as per IS 15683. The product shoul be certified by any EN notified body as per EN 3-7, EN 3-8, EN 3-9. The firm shall submit the product certificate from an EN notified body. The product should be EN PED approved and CE marked. Electrical test certificate:- Certificate from ERDA as per IS 15683:2006 (Cl No. 8.6) & BS EN3-7 2004+Al:2007(E) (Cl.No. :9) Warranty - 6 (Six) Years.
Supplying, fitting & fixing of CAFS (Compressed Air Foam System) watermist fire extinguisher 50 litre trolley mounted low pressure design 55a, Ivb. 1000v- Trolley mounted water mist & compressed Air Foam (CAF) System - 50Ltrs-Technology. (As per DIN EN 1866 - 1:2007-10standards) Water Container Capacity - 50 liters. Water Cylinder working pressure -- 05 to 12 bars. Water cylinder construction - Non Corrosive stainless steel SS 316. Water Cylinder external paint - The cylinder should be of red colour with powder coating. The paint should confirm to IS 5:2007 shade 538. Operating working pressure - not more than 11 bars. Air bottle - certification- PESO (Petroleum and explosive safely organization) Total Weight - Empty filled - not more than 54 kg (empty). Not more than 105 kh (water bottle filled & Air bottle filled capacity - 6 liter/300 bar air. Air bottle - construction- sim less mild steel cylinder. Operating temparature - Minimum + 5 degree to maximum + 60 degree celcius. Gun- construction- 1.r Device operation - shall be suitable for both left and right hand operations. Fire extinction - suitable - class-A, Class-B. Live electrical fires - 1000 V as per EN3-7/IS-15683 (Tested for 36Kva). System test : Electrical test Certificate - with details of test methods - Certification from ERDA as per IS 15683. Fire Rating Certificate - Certification from NABL accreditated Indian Lab as per EN3-7:2004+A1:2007 fire rating certificates for Class-A- Minimum A55. Fire rating Certificate for Class B- Minimum II B. Warranty-- 36 months (Air Cylinder). Spare Parts Support - 10 Years.
LITTLE HOPE
SONA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .