| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.8 LAdmitted-Finance | -11.00% | ₹12.8 L | L1 | Admitted-Finance |
| 2 | L2₹14.0 LAdmitted-Finance | -3.25% | ₹14.0 L | L2 | Admitted-Finance |
| 3 | L3₹14.1 LAdmitted-Finance | -2.51% | ₹14.1 L | L3 | Admitted-Finance |
| 4 | L4₹14.1 LAdmitted-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | -2.50% | ₹14.1 L | L4 | Admitted-Finance |
Tender Value
₹14.4 L
EMD Value
₹28,860
Closing Date
11 May 2026, 11:00 amClosed
SE CIVIL RVPNL JAIPUR
CHAMBEL POWER HOUSE HAWA SADAK JAIPUR SODALA
Providing and fixing of Air conditioners at 220 KV GSS Heerapura, Jaipur
2026_RRVPN_556113_1
RVPNL/SE/CIVIL/JPR/NIT02/2026
Open Tender
Civil Works
60 days
HEERAPURA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
ACCOUNTS OFFICER TAND C RRVPNL JAIPUR CITY
₹28,860
Yes
27 May 2026
4 May 2026
12 May 2026
4 May 2026
11 May 2026
4 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) Cooling capacity 5000-5300 Watt, ISEER not less then 4.6 | - | Each | 58,797.04 | - | BI01010001010000000000000515BI0100001113 |
| 2 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.20 amp, (2P + E), 3 Module | - | each | 3,505.78 | - | BI01010001010000000000000515BI0100001114 |
| 3 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.20 mm | - | mtr | 154.58 | - | BI01010001010000000000000515BI0100001115 |
| 4 | Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .4 kVA | - | Each | 3,370.08 | - | BI01010001010000000000000515BI0100001116 |
| 5 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | Each | 639.56 | - | BI01010001010000000000000515BI0100001117 |
| 6 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %-
99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | kg | 2,599.54 | - | BI01010001010000000000000515BI0100001118 |
| 7 | E-4.7.2 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.2.5 Sq.mm 3 core flat / Round. (E-4.7.2) | - | mtr | 156.94 | - | BI01010001010000000000000515BI0100001119 |
| 8 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 6 A to 32 A rating (E-6.1.1.2) | - | Each | 199.42 | - | BI01010001010000000000000515BI0100001120 |
| 9 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running
inch length | - | per inch | 79.06 | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
Tendernotice_2.pdf
PDF • 0.95 MB
Tendernotice_3.pdf
PDF • 0.67 MB
Tendernotice_4.pdf
PDF • 3.22 MB
Tendernotice_5.pdf
PDF • 0.72 MB
BOQ_990357.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid