| 1 | L1₹25.8 LAccepted-AOC K STAR HOTEL GROUND FLOOR SHOP NO 13 PUJIT PLAZA SOCIETY PLOT NO 67 SECTOR 11 CBD BELAPUR NAVI MUMBAI THANE 400614 | NAVI MUMBAI | THANE | MAHARASHTRA | 400614 | ₹25.8 L | L1 | Accepted-AOC AOC |
| 2 | L2₹25.9 LRejected-AOC B 001 SAMARTH DARSHAN C H S LTD NANDIVALI ROAD DOMBIVLI E DIST THANE 421201 | DOMBIVLI | THANE | MAHARASHTRA | 421201 | ₹25.9 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹26.6 LRejected-AOC E 2 ISHWAR NAGAR CHS OPP DENA BANK NEAR POST OFFICE LBS ROAD BHANDUP WEST MUMBAI 400078 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹26.6 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹28.8 LRejected-AOC 7TH 405 JAYDEEP EMPHASIS OFF LBS ROAD WAGLE MULUND CHECK NAKA THANE MAHARASHTRA 400604 | THANE | THANE | MAHARASHTRA | 400604 | ₹28.8 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹29.0 LRejected-AOC JALARAM MARKET SHOP NO 6 JAWAHAR ROAD AMRAVATI | AMRAVATI | AMRAVATI | MAHARASHTRA | ₹29.0 L | L5 | Rejected-AOC Rejected |
Tender Value
₹38.7 L
EMD Value
₹38,700
Closing Date
19 Nov 2025, 5:00 pmClosed
SE E and M Comm Mumbai
MIDC HQ office Udyog sarathi Andheri Mumbai 93
M and R to Shahad Water Works and UDDS Dombivali AMC of Street lights along with repairs to Electrification work at WTP Shahad and rewiring of effluent pump house at UDDS Dombivali
2025_MIDC_1240707_1
MIDC/E and M/AMB/37168/54/2025-26
Open Tender
Electrical and Maintenance Works
365 days
Shahad
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,030
₹38,700
30 Jan 2026
5 Nov 2025
21 Nov 2025
5 Nov 2025
19 Nov 2025
13 Nov 2025
5 Nov 2025 - 10 Nov 2025
Amount
Sub Est No.1 M&R to UDDS Dombivali… Rewiring of effluent pump house at UDDS Dombivali.
Item No.01 Dismantling (WG-DM) 1.1 Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW
Item No.02 Dismantling 2.1 Dismantling the existing ceilingfan/exhaustfan/ cabinfan/bracket fan completewith accessories, G.I. downrod,frameetc.andmakingthe site clear.
Item No.04 Point Wiring (WG-PW) 4.1 Pointwiringfor light/bell/exhaust fan nPVCtrunking(casing- capping)with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingandrequiredaccessoriesas per specification no. WG-PW/SW
4.2 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW
4.3 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW
4.4 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW
Item No.05 LT - MCBDBs (SW-MCBDB) 5.1 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB.
5.2 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways/36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB
Item No.06 LT - MCBs/ MCB Change Over Switch (SW-MCB) 6.1 Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
6.2 Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Item No.07 LT - MCCBs (SW-MCCB) 7.1 Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
Item No.08 Bunch of Wires (WG-MA/BW) 8.1 Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Item No. 09 PVC Flexible/Rigid Conduits/Casing-n-Capping/Under Floor Trunking/Raceways and Box System (WG-MA/CON) 9.1 Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON.
Item No.10 Fans (FG-FN) 10.1 Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF.
10.2 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
Item no.11 Modular switches and Accessories 11.1 Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete.
Item no.12 Accessories for Fans (FG-FAS) 12.1 Supplying & erecting 20 SWG G.I sheet metal cawl rectangular /round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FG-FAS/MSC.
Item no.13 Indoor LED Fittings (FG-IDF/LED) 13.1 Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED.
Item no.14 Highbay LED Fittings (FG-ODF/LED) 14.1 Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/LED.
Item no.15 Outdoor Fittings (FG-ODF) 15.1 Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL.
Item No.16 Street Light Boxes & Cable Indicators (CB-SB/CB-CIP) 16.1 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Item No.18 Accessories for Outdoor Fittings (FG-BKT) 18.1 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC.
Item no.19 Plate, Pipe type Earthing (EA-EP) 19.1Supplying, installing and testing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.I. cover complete with all accessories of G.I. materials & recording the results as per specification no. EA-EP
Item No.20 Accessories 20.1 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP.
item no.21 Credit for Dismantled Material 21.1 PVC armoured/unarmoured cables and wires (Aluminium)
21.2 PVC pipes/materials
21.3 Ceiling/cabin/bracket/pedestal/table fan.
Sub Estimate No.02 M&R to Shahad Water Works...Repairs to Electrification work at WTP Shahad. Item No.01 Dismantling (WG-DM) 1.1 Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW
Item No.02 Dismantling 2.1 Dismantling the existing cables of all types & size up to 10 sq mm.
Item No.03 Dismantling 3.1 Dismantling the existing ceilingfan/exhaustfan/ cabinfan/bracket fan completewith accessories, G.I. downrod,frameetc.andmakingthe site clear.
Item No.04 Point Wiring (WG-PW) 4.1 Pointwiringfor light/bell/exhaust fan nPVCtrunking(casing- capping)with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingandrequiredaccessoriesas per specification no. WG-PW/SW
4.2 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW
4.3 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW
4.4 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW
Item No.05 LT - MCBDBs (SW-MCBDB) 5.1 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB.
Item No.06 LT - MCBs/ MCB Change Over Switch (SW-MCB) 6.1 Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
6.2 Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Item No.07 LT - MCCBs (SW-MCCB) 7.1 Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
Item No.09 Bunch of Wires (WG-MA/BW) 9.1 Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Item No. 10PVC Flexible/Rigid Conduits/Casing-n-Capping/Under Floor Trunking/Raceways and Box System (WG-MA/CON) 10.1 Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON.
Item No.11 Fans (FG-FN) 11.1 Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF.
11.2 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
Item no.11.3 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Item no.11.4 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Item no.12 Accessories for Fans (FG-FAS) 12.1 Supplying & erecting 20 SWG G.I sheet metal cawl rectangular /round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FG-FAS/MSC.
Item no.13 Indoor LED Fittings (FG-IDF/LED) 13.1 Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED.
Item no.14 Decorative Outdoor Fittings (FG-ODF)14.1 Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL.
Item no.15 Highbay LED Fittings (FG-ODF/LED) 15.1 Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/LED.
Item no.16 Outdoor Fittings (FG-ODF) 16.1 Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL.
Item No.17 Accessories for Outdoor Fittings (FG-BKT) 17.1 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC.
Item no.18 Modular switches and Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete.
Item no.19 Plate, Pipe type Earthing (EA-EP) 19.1Supplying, installing and testing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.I. cover complete with all accessories of G.I. materials & recording the results as per specification no. EA-EP
Item No.20 Accessories 20.1 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP.
Item No.21 Street Light Boxes & Cable Indicators (CB-SB/CB-CIP) 21.1 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
Sub Est No.03 M&R to Shahad W/S/S & UDDS Dombivali...Annual maintenance of street lights in Shahad WTP premises & effluent pumping station premises at UDDS Dombivali Item no.01 Operation & Maintenance of streetlight poles & High mast with LED fittings, including licensed Electrician / wireman and helpers for day to day checking , identifying and rectifying the faults and also including replacing of burnt accessories of street light fitting, cable, wires, pipes, as directed by the Engineer-in-charge including replacing of damaged Timer,/ Contactor, /MCB,/ RCCB, /Isolator /and any other accessories inside the feeder pillar and operation of all circuits in feeders provided in the area, checking the same in night hours, carrying out periodical maintenance of feeder pillar such as checking of internal connection, cable joints, earthings, fuse replacement, adjusting the timer as & when required ,cleaning of grass and bushes 1.00 mtr area around the feeder pillar, Closing of the terminal boxes etc. informing the weekly report including no. of lights working & nonworking to the Engineer-in-charge. The item includes all the street light material required for its maintenance . The agency should have or may hire the mobile ladder for maintenance.
v tech electrical works (BID ID -7022039)
GURUDATT ELECTRICALS (BID ID -7032103)
SUVAS ELECTRICALS (BID ID -7034944)
SUN ENERGY CONSULTANCY SERVICES (BID ID -7035739)
SHIV VISHWA ELECTRICALS LLP (BID ID -7035565)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.44 MB
TenderDocument.pdf
Tender Documents • 0.42 MB
ItemSpecification.pdf
Other Document • 0.08 MB
BOQ_2140343.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid